A novel roof tile thermoelectric generator(RT-TEG)was used to harvest electrical energy from a solar heat source.The RT-TEG was fabricated and simulated by flat and curved thermoelectric modules consisting of p-n junc...A novel roof tile thermoelectric generator(RT-TEG)was used to harvest electrical energy from a solar heat source.The RT-TEG was fabricated and simulated by flat and curved thermoelectric modules consisting of p-n junctions of p-Sb_(2)Te_(3) and n-Bi_(2)Te_(3),with an Al_(2)O_(3) substrate at the top and bottom for heat absorption and heat rejection.The RT-TEG was installed in a roof tile to act as a generator.The electrical voltage and power values of the curved thermoelectric modules were higher than those of the flat thermoelectric module by 0.44 V and 80 mW,at a temperature difference(ΔT)of 100 K.In field tests,the RT-TEG produced a maximum electrical voltage of 33.70 mV and an electrical power of 46.24μW atΔT~7 K under a load resistance of 1Ωunder good sunshine at 13.00 hours.The energy conversion efficiency of RT-TEG was found to be 2.24×10^(−4).展开更多
Based on the engineering background of double-unit face mining under complicated geological conditions and the lagging fully-mechanized face surpassing the fore mechanized face of double-unit face in Zhou Yuanshan coa...Based on the engineering background of double-unit face mining under complicated geological conditions and the lagging fully-mechanized face surpassing the fore mechanized face of double-unit face in Zhou Yuanshan coal mine, strata-pressure behavior in the process was analyzed based on FLAC3D and on-site measurement. The results show that the stress concentration factor of superposition abutment pressure and the alternate distance of double-unit face are meeting gauss function, the relationship between the depth of stress concentration point and alternate distance also meets gaussian function. When the alternate distance is larger than 24 m, the superimposition of pilot support pressure in the double-unit face is weak. When the alternate distance is more than 12-15 m, the changes of the roof subsidence coefficient and the depth of stress con- centration point are stabilized; when the alternate distance is 3-6 m, the fore working face end is in the greatest impact area of superposition abutment pressure, this area should be avoided in determining the reasonable alternate distance.展开更多
基金supported by the Thailand Research Fund(TRF)Research Career Development Grant:(RSA6180070).
文摘A novel roof tile thermoelectric generator(RT-TEG)was used to harvest electrical energy from a solar heat source.The RT-TEG was fabricated and simulated by flat and curved thermoelectric modules consisting of p-n junctions of p-Sb_(2)Te_(3) and n-Bi_(2)Te_(3),with an Al_(2)O_(3) substrate at the top and bottom for heat absorption and heat rejection.The RT-TEG was installed in a roof tile to act as a generator.The electrical voltage and power values of the curved thermoelectric modules were higher than those of the flat thermoelectric module by 0.44 V and 80 mW,at a temperature difference(ΔT)of 100 K.In field tests,the RT-TEG produced a maximum electrical voltage of 33.70 mV and an electrical power of 46.24μW atΔT~7 K under a load resistance of 1Ωunder good sunshine at 13.00 hours.The energy conversion efficiency of RT-TEG was found to be 2.24×10^(−4).
基金Supported by the National Natural Science Foundation of China (50974059)
文摘Based on the engineering background of double-unit face mining under complicated geological conditions and the lagging fully-mechanized face surpassing the fore mechanized face of double-unit face in Zhou Yuanshan coal mine, strata-pressure behavior in the process was analyzed based on FLAC3D and on-site measurement. The results show that the stress concentration factor of superposition abutment pressure and the alternate distance of double-unit face are meeting gauss function, the relationship between the depth of stress concentration point and alternate distance also meets gaussian function. When the alternate distance is larger than 24 m, the superimposition of pilot support pressure in the double-unit face is weak. When the alternate distance is more than 12-15 m, the changes of the roof subsidence coefficient and the depth of stress con- centration point are stabilized; when the alternate distance is 3-6 m, the fore working face end is in the greatest impact area of superposition abutment pressure, this area should be avoided in determining the reasonable alternate distance.