Heat and mass transfer analysis of an incompressible, laminar boundary layer over solar flat plate collector evapora- tion systems for tannery effluent (soak liquor) is investigated. The governing equations are solved...Heat and mass transfer analysis of an incompressible, laminar boundary layer over solar flat plate collector evapora- tion systems for tannery effluent (soak liquor) is investigated. The governing equations are solved for various liquid to air velocity ratios. Profiles of velocity, temperature and concentration as well as their gradients are presented. The heat transfer and mass transfer coefficients thus obtained are used to evaluate mass of water evaporated for an inclined fibre-reinforced plastic (FRP) solar flat plate collector (FPC) with and without cover. Comparison of these results with the experimental performance shows encouraging trend of good agreement between them.展开更多
To research solar energy's efficiency and environmental benefits,the thermal efficiency,exergy,and entropy of solar collectors were calculated.The experiment involved two glass-topped collectors,fluid transfer tub...To research solar energy's efficiency and environmental benefits,the thermal efficiency,exergy,and entropy of solar collectors were calculated.The experiment involved two glass-topped collectors,fluid transfer tubes,and aluminum heat-absorbing plates.Glass wool insulation minimized heat loss.A 0.5% TiO_(2)/Water nanofluid was created using a mechanical and ultrasonic stirrer.Results showed that solar radiation increased thermal efficiency until midday,reaching 48.48% for water and 51.23% for the nanofluid.With increasing mass flow rates from 0.0045 kg/s to 0.02 kg/s,thermal efficiency improved from 16.26% to 47.37% for water and from 20.65% to 48.76% for the nanofluid.Filtered water provided 380 W and 395 W of energy in March and April,while the nanofluid increased it to 395 W and 415 W during these months.Mass flow generated energy,and the Reynolds number raised entropy.The noon exergy efficiency for nanofluids was 50%-55%,compared to 30% for water.At noon,the broken exergy measured 877.53 W for the nanofluid and 880.12 W for water.In Kirkuk,Iraq,the 0.5% TiO_(2)/Water nanofluid outperformed water in solar collectors.展开更多
Nanofluids are a potential alternative to significantly improving the performance of heat transfer applications. In this work, a numerical analysis to examine the eff ect of dispersing copper(Cu), copper oxide(CuO), a...Nanofluids are a potential alternative to significantly improving the performance of heat transfer applications. In this work, a numerical analysis to examine the eff ect of dispersing copper(Cu), copper oxide(CuO), and aluminum(Al2O3) nanoparticles in pure water on the performance of a flat plate solar collector(FPSC) and a numerical model was proposed. The influence of the nanofluid type on the thermal efficiency was critically investigated and discussed. The eff ect of the mass flow rate on the performance was also analyzed and discussed. Based on correlations of the thermophysical properties of nanofluids, a sensitivity analysis was used to analyze the impact of the nanoparticles on the base fluid. The results indicate that the performance of the FPSC with Cu/water nanofluid was better than that of FPSCs using CuO/water or Al2O3/water nanofluids. When the mass flow rate of the nanofluids was 8.0 L/min, the efficiency of the FPSC was much greater than those at the flow rates of 5.0 L/min and 2.0 L/min. Mean enhancements in thermal efficiency of 4.44%, 4.27%, and 4.21% were observed when 2.0 L/min was applied using Cu/water, Cu O/water, and Al2O3/water nanofluids, respectively. Improvements in thermal efficiency of 2.76%, 2.53%, and 2.47% occurred when 8.0 L/min was applied.展开更多
This paper shows the modeling of a solar collective heating system in order to predict the system performances. Two systems are proposed: 1) the first, Solar Direct Hot Water, which is composed of flat plate collector...This paper shows the modeling of a solar collective heating system in order to predict the system performances. Two systems are proposed: 1) the first, Solar Direct Hot Water, which is composed of flat plate collectors and thermal storage tank, 2) the second, a Solar Indirect Hot Water in which we added an external heat exchanger of constant effectiveness to the first system. The mass flow rate by a collector is fixed to 0.04 Kg·s–1 and the total number of collectors is adjusted to 60. For the first system, the maximum average water temperature within the tank in a typical day in summer and annual performances are calculated by varying the number of collectors connected in series. For the second, this paper shows the detailed analysis of water temperature within the storage and annual performances by varying the mass flow rate on the cold side of the heat exchanger and the number of collectors in series on the hot side. It is shown that the stratification within the storage is strongly influenced by mass flow rate and the connections between collectors. It is also demonstrated that the number of collectors that can be connected in series is limited. The optimization of the mass flow rate on cold side of the heat exchanger is seen to be an important factor for the energy saving.展开更多
Solar water collectors that uses for domestic and industrial applications within temperature up to, are classified under two main types: Flat Plate collector (FP), and Evacuated Tube collector (ET). Thermal performanc...Solar water collectors that uses for domestic and industrial applications within temperature up to, are classified under two main types: Flat Plate collector (FP), and Evacuated Tube collector (ET). Thermal performance test results showed that each type have different thermal features. Comparison between (FP & ET) collectors showed that they could take advantages of different thermal features of two types when they work in the same climatic conditions and overlap of these thermal features when they work in different operational conditions. They can take advantage of these features through (compound) solar collector. Compound solar water Collector (CO) composed of a part of flat plate collector shape (FP), and a part of evacuated tube collector shape (ET). Booth have equal reference area, and connected together to be as one Solar collector (CO). Water entered first flat part (FP), then evacuated tube part (ET) then to tank or end-use. In this paper, present design and manufacturing as well the thermal performance test of (compound) solar collector, according to Standard Specification of tests, was EN12975:2001. Mechanical test for (CO) collector conducted successfully according to durability, reliability, and safety requirements. In addition, thermal performance was tested in steady state at the climatic conditions of Damascus city, and concluded the thermal performance of (FP & ET) that constitute (CO) collector. The results showed enhancement of thermal performance.展开更多
A hybrid solar collector was designed to investigate the effects of combining two different solar collector techniques on the overall collector’s effectiveness. While most solar collectors focus only on one solar col...A hybrid solar collector was designed to investigate the effects of combining two different solar collector techniques on the overall collector’s effectiveness. While most solar collectors focus only on one solar collection method, the small hybrid system uses a flat plate collector in conjunction with five evacuated tubes to absorb the most energy possible from both direct and diffuse solar radiation. Data was collected over four months while the system operated at different flow rates and with various levels of available insolation from the sun to evaluate the performance of the solar collector. To understand the relative contribution of the flat plate collector and the evacuated tubes, temperature differences across each part of the system were measured. The results indicate the average first law efficiency of the hybrid system is 43.3%, significantly higher than the performance of the flat plate alone. An exergy analysis was performed for this system to assess the performance of the flat plate system by itself. Results of the second law analysis were comparable to the exergetic efficiencies of other experimental collectors, around 4%. Though the efficiencies were in the expected range, they reveal that further improvements to the system are possible.展开更多
文摘Heat and mass transfer analysis of an incompressible, laminar boundary layer over solar flat plate collector evapora- tion systems for tannery effluent (soak liquor) is investigated. The governing equations are solved for various liquid to air velocity ratios. Profiles of velocity, temperature and concentration as well as their gradients are presented. The heat transfer and mass transfer coefficients thus obtained are used to evaluate mass of water evaporated for an inclined fibre-reinforced plastic (FRP) solar flat plate collector (FPC) with and without cover. Comparison of these results with the experimental performance shows encouraging trend of good agreement between them.
文摘To research solar energy's efficiency and environmental benefits,the thermal efficiency,exergy,and entropy of solar collectors were calculated.The experiment involved two glass-topped collectors,fluid transfer tubes,and aluminum heat-absorbing plates.Glass wool insulation minimized heat loss.A 0.5% TiO_(2)/Water nanofluid was created using a mechanical and ultrasonic stirrer.Results showed that solar radiation increased thermal efficiency until midday,reaching 48.48% for water and 51.23% for the nanofluid.With increasing mass flow rates from 0.0045 kg/s to 0.02 kg/s,thermal efficiency improved from 16.26% to 47.37% for water and from 20.65% to 48.76% for the nanofluid.Filtered water provided 380 W and 395 W of energy in March and April,while the nanofluid increased it to 395 W and 415 W during these months.Mass flow generated energy,and the Reynolds number raised entropy.The noon exergy efficiency for nanofluids was 50%-55%,compared to 30% for water.At noon,the broken exergy measured 877.53 W for the nanofluid and 880.12 W for water.In Kirkuk,Iraq,the 0.5% TiO_(2)/Water nanofluid outperformed water in solar collectors.
文摘Nanofluids are a potential alternative to significantly improving the performance of heat transfer applications. In this work, a numerical analysis to examine the eff ect of dispersing copper(Cu), copper oxide(CuO), and aluminum(Al2O3) nanoparticles in pure water on the performance of a flat plate solar collector(FPSC) and a numerical model was proposed. The influence of the nanofluid type on the thermal efficiency was critically investigated and discussed. The eff ect of the mass flow rate on the performance was also analyzed and discussed. Based on correlations of the thermophysical properties of nanofluids, a sensitivity analysis was used to analyze the impact of the nanoparticles on the base fluid. The results indicate that the performance of the FPSC with Cu/water nanofluid was better than that of FPSCs using CuO/water or Al2O3/water nanofluids. When the mass flow rate of the nanofluids was 8.0 L/min, the efficiency of the FPSC was much greater than those at the flow rates of 5.0 L/min and 2.0 L/min. Mean enhancements in thermal efficiency of 4.44%, 4.27%, and 4.21% were observed when 2.0 L/min was applied using Cu/water, Cu O/water, and Al2O3/water nanofluids, respectively. Improvements in thermal efficiency of 2.76%, 2.53%, and 2.47% occurred when 8.0 L/min was applied.
文摘This paper shows the modeling of a solar collective heating system in order to predict the system performances. Two systems are proposed: 1) the first, Solar Direct Hot Water, which is composed of flat plate collectors and thermal storage tank, 2) the second, a Solar Indirect Hot Water in which we added an external heat exchanger of constant effectiveness to the first system. The mass flow rate by a collector is fixed to 0.04 Kg·s–1 and the total number of collectors is adjusted to 60. For the first system, the maximum average water temperature within the tank in a typical day in summer and annual performances are calculated by varying the number of collectors connected in series. For the second, this paper shows the detailed analysis of water temperature within the storage and annual performances by varying the mass flow rate on the cold side of the heat exchanger and the number of collectors in series on the hot side. It is shown that the stratification within the storage is strongly influenced by mass flow rate and the connections between collectors. It is also demonstrated that the number of collectors that can be connected in series is limited. The optimization of the mass flow rate on cold side of the heat exchanger is seen to be an important factor for the energy saving.
文摘Solar water collectors that uses for domestic and industrial applications within temperature up to, are classified under two main types: Flat Plate collector (FP), and Evacuated Tube collector (ET). Thermal performance test results showed that each type have different thermal features. Comparison between (FP & ET) collectors showed that they could take advantages of different thermal features of two types when they work in the same climatic conditions and overlap of these thermal features when they work in different operational conditions. They can take advantage of these features through (compound) solar collector. Compound solar water Collector (CO) composed of a part of flat plate collector shape (FP), and a part of evacuated tube collector shape (ET). Booth have equal reference area, and connected together to be as one Solar collector (CO). Water entered first flat part (FP), then evacuated tube part (ET) then to tank or end-use. In this paper, present design and manufacturing as well the thermal performance test of (compound) solar collector, according to Standard Specification of tests, was EN12975:2001. Mechanical test for (CO) collector conducted successfully according to durability, reliability, and safety requirements. In addition, thermal performance was tested in steady state at the climatic conditions of Damascus city, and concluded the thermal performance of (FP & ET) that constitute (CO) collector. The results showed enhancement of thermal performance.
文摘A hybrid solar collector was designed to investigate the effects of combining two different solar collector techniques on the overall collector’s effectiveness. While most solar collectors focus only on one solar collection method, the small hybrid system uses a flat plate collector in conjunction with five evacuated tubes to absorb the most energy possible from both direct and diffuse solar radiation. Data was collected over four months while the system operated at different flow rates and with various levels of available insolation from the sun to evaluate the performance of the solar collector. To understand the relative contribution of the flat plate collector and the evacuated tubes, temperature differences across each part of the system were measured. The results indicate the average first law efficiency of the hybrid system is 43.3%, significantly higher than the performance of the flat plate alone. An exergy analysis was performed for this system to assess the performance of the flat plate system by itself. Results of the second law analysis were comparable to the exergetic efficiencies of other experimental collectors, around 4%. Though the efficiencies were in the expected range, they reveal that further improvements to the system are possible.