Shaanxi province has three land forms which are Shaanxi’s northern plateau, Guanzhong plain and Qinba mountain land in the south of Shaanxi province. So the climate type is also divided into three types and the solar...Shaanxi province has three land forms which are Shaanxi’s northern plateau, Guanzhong plain and Qinba mountain land in the south of Shaanxi province. So the climate type is also divided into three types and the solar energy resources distribution has a big gap between different regions. PV modules, as the core component of off-grid home photovoltaic power system, their output power are mainly influenced by sun radiation, array tile angle, temperature and so on. Based on the reasons above, in order to apply off-grid home photovoltaic power system in Shaanxi region, this paper designs different systems with different configuration, and makes the performance prediction. The results show that the capacity of PV modules reaches to the largest in Shaanxi northern region, reach minimum in Shaanxi southern region and the output power in the winter is less than in the summer and reach minimum in the spring and autumn. In light of the characteristics above, this research select different type and configuration in different areas systematically, and the performance analysis shows that the configuration can meet the basic life demand of power to the people whose power is not available.展开更多
Because working performance of off-grid home photovoltaic power system is influenced by factors of solar radiation, ambient temperature and installation angle, this research established power supply model, analyzed wo...Because working performance of off-grid home photovoltaic power system is influenced by factors of solar radiation, ambient temperature and installation angle, this research established power supply model, analyzed working performance and optimized system configuration, by referencing weather conditions of Yulin and Yan’an and those factors. Results showed that under given solar radiation and ambient temperature, difference of installation angle can cause 30% to 40% difference of performance. In order to meet power demand, installation angles of Yulin and Yan'an were selected as 40 degree and 30 degree, and annual output power were 1.44 kWh/Wp and 1.32 kWh/Wp. Based on those results, the configuration of Yulin and Yan'an was 150 Wp and 170 Wp, and annual output power was 172.70 kWh and 179.66 kWh. Systems optimized above can meet the mid-scale demand in Shaanxi northern region and build theoretical foundation of application.展开更多
For domestic consumers in the rural areas of northern Kenya, as in other developing countries, the typical source of electrical supply is diesel generators. However, diesel generators are associated with both CO2 emis...For domestic consumers in the rural areas of northern Kenya, as in other developing countries, the typical source of electrical supply is diesel generators. However, diesel generators are associated with both CO2 emissions, which adversely affect the environment and increase diesel fuel prices, which inflate the prices of consumer goods. The Kenya government has taken steps towards addressing this issue by proposing The Hybrid Mini-Grid Project, which involves the installation of 3 MW of wind and solar energy systems in facilities with existing diesel generators. However, this project has not yet been implemented. As a contribution to this effort, this study proposes, simulates and analyzes five different configurations of hybrid energy systems incorporating wind energy, solar energy and battery storage to replace the stand-alone diesel power systems servicing six remote villages in northern Kenya. If implemented, the systems proposed here would reduce Kenya’s dependency on diesel fuel, leading to reductions in its carbon footprint. This analysis confirms the feasibility of these hybrid systems with many configurations being profitable. A Multi-Attribute Trade-Off Analysis is employed to determine the best hybrid system configuration option that would reduce diesel fuel consumption and jointly minimize CO2 emissions and net present cost. This analysis determined that a wind-diesel-battery configuration consisting of two 500 kW turbines, 1200 kW diesel capacity and 95,040 Ah battery capacity is the best option to replace a 3200 kW stand-alone diesel system providing electricity to a village with a peak demand of 839 kW. It has the potential to reduce diesel fuel consumption and CO2 emissions by up to 98.8%.展开更多
Air pollution from shipping is becoming a critical issue,particularly in dense hub port cities.One proposed solution to minimize ship-based emissions at ports is the implementation of an Onshore Power Supply(OPS)syste...Air pollution from shipping is becoming a critical issue,particularly in dense hub port cities.One proposed solution to minimize ship-based emissions at ports is the implementation of an Onshore Power Supply(OPS)system.OPS allows ships to shut off their auxiliary engines and instead connect to the port grid.While there have been numerous studies conducted on ports in Europe and the United States,little research has been done on Egyptian ports.Therefore,this paper aims to investigate the feasibility of implementing OPS at Port Said West Port in Egypt,aligning with Egypt Vision 2030’s goals for addressing climate change.The research primarily focuses on analyzing data collected from calling ships to generate socio-economic and cost-effectiveness analyses of OPS.To further enhance the environmental benefits of OPS,the paper proposes the use of solar energy as the OPS electricity source.The findings of the study revealed that by relying on the national grid,emissions can be reduced by 28%.Moreover,it is predicted that this reduction could reach 100%if electricity generation is solely based on solar energy.Additionally,the economic analysis demonstrates promising profitability,with a payback period of approximately two years.展开更多
In order to testify and examine the ability and correctness of an expert system for diagnosing the faults in the electrical power system of a certain kind of satellite, the authors have developed a simulated testbed a...In order to testify and examine the ability and correctness of an expert system for diagnosing the faults in the electrical power system of a certain kind of satellite, the authors have developed a simulated testbed according to the operational principle of the electrical power system. This paper takes the solar battery array as an instance to introduce the designing principle of its hardware circuits, and presents the methods to design the interface and the software program of the single-chip microprocessor system. The software scheme of the upper computer is introduced at the end of this paper. It has been proved that this simulated system could effectively achieve the complete functions coupled with the simple design by using of various mature techniques in the fields of electronic circuits, single-chip microprocessor and numerical emulation.展开更多
文摘Shaanxi province has three land forms which are Shaanxi’s northern plateau, Guanzhong plain and Qinba mountain land in the south of Shaanxi province. So the climate type is also divided into three types and the solar energy resources distribution has a big gap between different regions. PV modules, as the core component of off-grid home photovoltaic power system, their output power are mainly influenced by sun radiation, array tile angle, temperature and so on. Based on the reasons above, in order to apply off-grid home photovoltaic power system in Shaanxi region, this paper designs different systems with different configuration, and makes the performance prediction. The results show that the capacity of PV modules reaches to the largest in Shaanxi northern region, reach minimum in Shaanxi southern region and the output power in the winter is less than in the summer and reach minimum in the spring and autumn. In light of the characteristics above, this research select different type and configuration in different areas systematically, and the performance analysis shows that the configuration can meet the basic life demand of power to the people whose power is not available.
文摘Because working performance of off-grid home photovoltaic power system is influenced by factors of solar radiation, ambient temperature and installation angle, this research established power supply model, analyzed working performance and optimized system configuration, by referencing weather conditions of Yulin and Yan’an and those factors. Results showed that under given solar radiation and ambient temperature, difference of installation angle can cause 30% to 40% difference of performance. In order to meet power demand, installation angles of Yulin and Yan'an were selected as 40 degree and 30 degree, and annual output power were 1.44 kWh/Wp and 1.32 kWh/Wp. Based on those results, the configuration of Yulin and Yan'an was 150 Wp and 170 Wp, and annual output power was 172.70 kWh and 179.66 kWh. Systems optimized above can meet the mid-scale demand in Shaanxi northern region and build theoretical foundation of application.
文摘For domestic consumers in the rural areas of northern Kenya, as in other developing countries, the typical source of electrical supply is diesel generators. However, diesel generators are associated with both CO2 emissions, which adversely affect the environment and increase diesel fuel prices, which inflate the prices of consumer goods. The Kenya government has taken steps towards addressing this issue by proposing The Hybrid Mini-Grid Project, which involves the installation of 3 MW of wind and solar energy systems in facilities with existing diesel generators. However, this project has not yet been implemented. As a contribution to this effort, this study proposes, simulates and analyzes five different configurations of hybrid energy systems incorporating wind energy, solar energy and battery storage to replace the stand-alone diesel power systems servicing six remote villages in northern Kenya. If implemented, the systems proposed here would reduce Kenya’s dependency on diesel fuel, leading to reductions in its carbon footprint. This analysis confirms the feasibility of these hybrid systems with many configurations being profitable. A Multi-Attribute Trade-Off Analysis is employed to determine the best hybrid system configuration option that would reduce diesel fuel consumption and jointly minimize CO2 emissions and net present cost. This analysis determined that a wind-diesel-battery configuration consisting of two 500 kW turbines, 1200 kW diesel capacity and 95,040 Ah battery capacity is the best option to replace a 3200 kW stand-alone diesel system providing electricity to a village with a peak demand of 839 kW. It has the potential to reduce diesel fuel consumption and CO2 emissions by up to 98.8%.
文摘Air pollution from shipping is becoming a critical issue,particularly in dense hub port cities.One proposed solution to minimize ship-based emissions at ports is the implementation of an Onshore Power Supply(OPS)system.OPS allows ships to shut off their auxiliary engines and instead connect to the port grid.While there have been numerous studies conducted on ports in Europe and the United States,little research has been done on Egyptian ports.Therefore,this paper aims to investigate the feasibility of implementing OPS at Port Said West Port in Egypt,aligning with Egypt Vision 2030’s goals for addressing climate change.The research primarily focuses on analyzing data collected from calling ships to generate socio-economic and cost-effectiveness analyses of OPS.To further enhance the environmental benefits of OPS,the paper proposes the use of solar energy as the OPS electricity source.The findings of the study revealed that by relying on the national grid,emissions can be reduced by 28%.Moreover,it is predicted that this reduction could reach 100%if electricity generation is solely based on solar energy.Additionally,the economic analysis demonstrates promising profitability,with a payback period of approximately two years.
文摘In order to testify and examine the ability and correctness of an expert system for diagnosing the faults in the electrical power system of a certain kind of satellite, the authors have developed a simulated testbed according to the operational principle of the electrical power system. This paper takes the solar battery array as an instance to introduce the designing principle of its hardware circuits, and presents the methods to design the interface and the software program of the single-chip microprocessor system. The software scheme of the upper computer is introduced at the end of this paper. It has been proved that this simulated system could effectively achieve the complete functions coupled with the simple design by using of various mature techniques in the fields of electronic circuits, single-chip microprocessor and numerical emulation.