Concentrating solar thermal power system can provide low carbon,renewable energy resources in countries or regions with strong solar irradiation.For this kind of power plant which is likely to be located in the arid a...Concentrating solar thermal power system can provide low carbon,renewable energy resources in countries or regions with strong solar irradiation.For this kind of power plant which is likely to be located in the arid area,natural draft dry cooling tower is a promising choice.To develop the experimental studies on small cooling tower,a 20 m high natural draft dry cooling tower with fully instrumented measurement system was established by the Queensland Geothermal Energy Centre of Excellence.The performance of this cooling tower was measured with the constant heat input of 600 kW and 840 kW and with ambient temperature ranging from 20 ℃ to 32 ℃.The cooling tower numerical model was refined and validated with the experimental data.The model of 1 MW concentrating solar thermal supercritical CO2 power cycle was developed and integrated with the cooling tower model.The influences of changing ambient temperature and the performance of the cooling tower on efficiency of the power system were simulated.The differences of the mechanism of the ambient temperature effect on Rankine cycle and supercritical CO2 Brayton cycle were analysed and discussed.展开更多
The receiver is an important element in solar energy plants.The principal receiver’s tubes in power plants are devised to work under extremely severe conditions,including excessive heat fluxes.Half of the tube’s cir...The receiver is an important element in solar energy plants.The principal receiver’s tubes in power plants are devised to work under extremely severe conditions,including excessive heat fluxes.Half of the tube’s circumference is heated whilst the other half is insulated.This study aims to improve the heat transfer process and reinforce the tubes’structure by designing a new receiver;by including longitudinal fins of triangular,circular and square shapes.The research is conducted experimentally using Reynolds numbers ranging from 28,000 to 78,000.Triangular fins have demonstrated the best improvement for heat transfer.For Reynolds number value near 43,000 Nusselt number(Nu)is higher by 3.5%and 7.5%,sequentially,compared to circular and square tube fins,but varies up to 6.5%near Re=61000.The lowest friction factor is seen in a triangular fin receiver;where it deviates from circular fins by 4.6%,and square fin tubes by 3.2%.Adding fins makes the temperature decrease gradually,and in the case of no fins,the temperature gradient between the hot tube and water drops sharply in the planed tube by 7%.展开更多
The entransy theory, which can be used to optimize the heat transfer network of a solar power tower system (SPTS) and im- prove its energy efficiency, was introduced in this paper. Firstly, the irreversibility of th...The entransy theory, which can be used to optimize the heat transfer network of a solar power tower system (SPTS) and im- prove its energy efficiency, was introduced in this paper. Firstly, the irreversibility of the heat transfer processes in a SPTS was analyzed and the total entransy dissipation equation of a SPTS was derived. Then, two types of optimization problems (reduc- ing the total circulating flow rate or the total heat-exchanging area) of a SPTS were solved with conditional extremum model based on the formulas of total entransy dissipation. Finally, the entransy dissipation-based optimization principle was applied to a simple SPTS without re-heater and a complex SPTS with a re-heater. The results showed that under the chosen calculation conditions the minimum total thermal conductance was 19306.03 W K-~ for a SPTS without re-heater when the total heat ca- pacity rate of heat transfer fluid (HTF) was 3200 W K-1. The minimum total thermal conductance was about 7.9% lower than the value predicted based on the typical outlet temperature of a receiver. This meant that the total heat exchange area or initial investment could be effectively reduced under the prescribed total HTF circulating flow rate. We also studied the variation trends of the two optimized results including minimum total HTF heat capacity rate and minimum total thermal conductance. The minimum total HTF heat capacity rate decreased with the given total thermal conductance, the minimum total thermal conductance decreased first and then increased with the given total HTF heat capacity rate. We also found that for a SPTS with a re-heater, the mixing temperature and the mixing position of HTF had significant effects on the two types of optimization problems.展开更多
Solar multiple (SM) and thermal storage capacity are two key design parameters for revealing the performance of direct steam generation (DSG) solar power tower plant. In the case of settled land area, SM and therm...Solar multiple (SM) and thermal storage capacity are two key design parameters for revealing the performance of direct steam generation (DSG) solar power tower plant. In the case of settled land area, SM and thermal storage capacity can be optimized to obtain the minimum levelized cost of electricity (LCOE) by adjusting the power generation output. Taking the dual-receiver DSG solar power tower plant with a given size of solar field equivalent electricity of 100 MWe in Sevilla as a reference case, the minimum LCOE is 21.77 /kWhe with an SM of 1.7 and a thermal storage capacity of 3 h. Besides Sevilla, two other sites are also introduced to discuss the influence of annual DNI. When compared with the case of Sevilla, the minimum LCOE and optimal SM of the San Jose site change just slightly, while the minimum LCOE of the Bishop site decreases by 32.8% and the optimal SM is reduced to 1.3. The influence of the size of solar field equivalent electricity is studied as well. The minimum LCOE decreases with the size of solar field, while the optimal SM and thermal storage capacity still remain unchanged. In addition, the sensitivity of different investment in sub-system is investigated. In terms ofoptimal SM and thermal storage capacity, they can decrease with the cost of thermal storage system but increase with the cost of power generation unit.展开更多
文摘Concentrating solar thermal power system can provide low carbon,renewable energy resources in countries or regions with strong solar irradiation.For this kind of power plant which is likely to be located in the arid area,natural draft dry cooling tower is a promising choice.To develop the experimental studies on small cooling tower,a 20 m high natural draft dry cooling tower with fully instrumented measurement system was established by the Queensland Geothermal Energy Centre of Excellence.The performance of this cooling tower was measured with the constant heat input of 600 kW and 840 kW and with ambient temperature ranging from 20 ℃ to 32 ℃.The cooling tower numerical model was refined and validated with the experimental data.The model of 1 MW concentrating solar thermal supercritical CO2 power cycle was developed and integrated with the cooling tower model.The influences of changing ambient temperature and the performance of the cooling tower on efficiency of the power system were simulated.The differences of the mechanism of the ambient temperature effect on Rankine cycle and supercritical CO2 Brayton cycle were analysed and discussed.
文摘The receiver is an important element in solar energy plants.The principal receiver’s tubes in power plants are devised to work under extremely severe conditions,including excessive heat fluxes.Half of the tube’s circumference is heated whilst the other half is insulated.This study aims to improve the heat transfer process and reinforce the tubes’structure by designing a new receiver;by including longitudinal fins of triangular,circular and square shapes.The research is conducted experimentally using Reynolds numbers ranging from 28,000 to 78,000.Triangular fins have demonstrated the best improvement for heat transfer.For Reynolds number value near 43,000 Nusselt number(Nu)is higher by 3.5%and 7.5%,sequentially,compared to circular and square tube fins,but varies up to 6.5%near Re=61000.The lowest friction factor is seen in a triangular fin receiver;where it deviates from circular fins by 4.6%,and square fin tubes by 3.2%.Adding fins makes the temperature decrease gradually,and in the case of no fins,the temperature gradient between the hot tube and water drops sharply in the planed tube by 7%.
基金supported by the National Natural Science Foundation of China(Grant No.U1261112)the Research Project of Chinese Ministry of Education(Grant Nos.113055A,20120201130006)
文摘The entransy theory, which can be used to optimize the heat transfer network of a solar power tower system (SPTS) and im- prove its energy efficiency, was introduced in this paper. Firstly, the irreversibility of the heat transfer processes in a SPTS was analyzed and the total entransy dissipation equation of a SPTS was derived. Then, two types of optimization problems (reduc- ing the total circulating flow rate or the total heat-exchanging area) of a SPTS were solved with conditional extremum model based on the formulas of total entransy dissipation. Finally, the entransy dissipation-based optimization principle was applied to a simple SPTS without re-heater and a complex SPTS with a re-heater. The results showed that under the chosen calculation conditions the minimum total thermal conductance was 19306.03 W K-~ for a SPTS without re-heater when the total heat ca- pacity rate of heat transfer fluid (HTF) was 3200 W K-1. The minimum total thermal conductance was about 7.9% lower than the value predicted based on the typical outlet temperature of a receiver. This meant that the total heat exchange area or initial investment could be effectively reduced under the prescribed total HTF circulating flow rate. We also studied the variation trends of the two optimized results including minimum total HTF heat capacity rate and minimum total thermal conductance. The minimum total HTF heat capacity rate decreased with the given total thermal conductance, the minimum total thermal conductance decreased first and then increased with the given total HTF heat capacity rate. We also found that for a SPTS with a re-heater, the mixing temperature and the mixing position of HTF had significant effects on the two types of optimization problems.
基金This research was supported by the National Natural Science Foundation of China (Grant No. 51676069), the 111 Project (1312034), and the Fundamental Research Funds for the Central Universities (Grant No. 2016XS30).
文摘Solar multiple (SM) and thermal storage capacity are two key design parameters for revealing the performance of direct steam generation (DSG) solar power tower plant. In the case of settled land area, SM and thermal storage capacity can be optimized to obtain the minimum levelized cost of electricity (LCOE) by adjusting the power generation output. Taking the dual-receiver DSG solar power tower plant with a given size of solar field equivalent electricity of 100 MWe in Sevilla as a reference case, the minimum LCOE is 21.77 /kWhe with an SM of 1.7 and a thermal storage capacity of 3 h. Besides Sevilla, two other sites are also introduced to discuss the influence of annual DNI. When compared with the case of Sevilla, the minimum LCOE and optimal SM of the San Jose site change just slightly, while the minimum LCOE of the Bishop site decreases by 32.8% and the optimal SM is reduced to 1.3. The influence of the size of solar field equivalent electricity is studied as well. The minimum LCOE decreases with the size of solar field, while the optimal SM and thermal storage capacity still remain unchanged. In addition, the sensitivity of different investment in sub-system is investigated. In terms ofoptimal SM and thermal storage capacity, they can decrease with the cost of thermal storage system but increase with the cost of power generation unit.