期刊文献+
共找到11,088篇文章
< 1 2 250 >
每页显示 20 50 100
Determination of urinary 8-hydroxy-2′-deoxyguanosine by capillary electrophoresis with molecularly imprinted monolith in-tube solid phase microextraction 被引量:6
1
作者 Zhang, Shao Wen Zou, Cun Jie +4 位作者 Luo, Nan Weng, Qian Feng Cai, Ling Shuang Wu, Cai Ying Xing, Jun 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第1期85-88,共4页
Urinary 8-hydroxy-2 -deoxyguanosine(8-OHdG) is an excellent marker of oxidative DNA damage.In this study,employing guanosine as dummy template a novel molecularly imprinted(MIP) monolithic capillary column had been sy... Urinary 8-hydroxy-2 -deoxyguanosine(8-OHdG) is an excellent marker of oxidative DNA damage.In this study,employing guanosine as dummy template a novel molecularly imprinted(MIP) monolithic capillary column had been synthesized,and that was used as medium of in-tube solid phase microextraction(SPME).Coupled with capillary electrophoresis-electrochemical detection(CE-ECD),the system of extraction and detection of 8-OHdG in urinary sample had been developed.Because of its greater phase ratio combined with conv... 展开更多
关键词 Molecularly imprinted monolith In-tube solid phase microextraction 8-Hydroxy-2 -deoxyguanosine(8-OHdG) Electrophoresis Urine
下载PDF
Analysis of α, β, γ-hexachlorocyclohexanes in water by novel activated carbon fiber-solid phase microextraction coupled with gas chromatography—mass spectrometry 被引量:4
2
作者 SUNTong-hua FANGNeng-hu +2 位作者 ZHUNan-wen WANGYa-lin JIAJin-ping 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2004年第6期945-949,共5页
A fast and simple method for determination of α, β, γ-hexachlorocyclohexanes (HCHs) in water using activated carbon fiber-solid phase microextraction(ACF-SPME) were studied. Results showed the performance of adsorp... A fast and simple method for determination of α, β, γ-hexachlorocyclohexanes (HCHs) in water using activated carbon fiber-solid phase microextraction(ACF-SPME) were studied. Results showed the performance of adsorption and desorption of three HCHs on ACF were excellent. A wide linear range from 10 to 100 μg/L and detection limits of the ng/L level were obtained using ACF-SPME with GC-MS in selected ion monitoring(SIM) acquisition mode. The proposed method was also successfully applied for determination of three HCHs in tap water. Compared to commercial fibers, ACF showed some advantages such as better resistance to solvents, higher thermal stability, longer lifetime and lower cost. The data demonstrated that GC-MS with ACF-SPME is well suitable for the analysis of HCHs in water. 展开更多
关键词 solid phase microextraction activated carbon fiber residue analysis α β γ-hexachlorocyclohexanes GC-MS
下载PDF
Comparison of Headspace Solid-Phase Microextraction with Simultaneous Steam Distillation Extraction for the Analysis of the Volatile Constituents in Chinese Apricot 被引量:20
3
作者 CHEN Mei-xia CHEN Xue-sen +4 位作者 WANG Xin-guo CI Zhi-juan LIU Xiao-li HE Tian-ming ZHANG Li-jie 《Agricultural Sciences in China》 CAS CSCD 2006年第11期879-884,共6页
Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction ... Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction (SSDE) and then analyzed using capillary gas chromatography and gas chromatography-mass spectrometry. A total of 70 components were identified by HSSPME, including 20 esters, 19 hydrocarbons, 5 alcohols, 5 ketones, 4 acids, 4 lactones, 3 aldehydes, and 10 miscellaneous components, with the esters being the dominant constituent. On the basis of the odor unit values, it is believed that the following compounds probably contributed to the fresh apricot odor: hexyl acetate, β-ionone, butyl acetate, (E)-2-hexenal, linalool, limonene, γ-decalactone, and hexanal. A total of 49 components were also detected by SSDE, including 13 hydrocarbons, 9 alcohols, 7 aldehydes, 9 esters, 4 ketones, 4 lactones, 2 acids, and 1 miscellaneous component, of which the monoterpene alcohols were the dominant constituents. It could be judged from the odor unit values that the following compounds were the major contributors to boiled apricot aroma: β-ionone, linalool, hexyl acetate, γ-dodecalactone, γ- decalactone, (E)-2-hexenal, hexanal, γ-octalactone, phenylacetaldehyde, butyl acetate, limonene, α-terpineol, and δ-decalactone. The results show that HS-SPME is a simple, rapid, and solvent-free method, which is an alternative to the classical SSDE. 展开更多
关键词 AROMA volatile constituents APRICOT solid-phase microextraction simultaneous distillation-extraction
下载PDF
Solid phase microextraction chemical biopsy tool for monitoring of doxorubicin residue during in vivo lung chemo-perfusion 被引量:6
4
作者 Barbara Bojko Nikita Looby +11 位作者 Mariola Olkowicz Anna Roszkowska Bogumiła Kupcewicz Pedro Reck dos Santos Khaled Ramadan Shaf Keshavjee Thomas K.Waddell German Goomez-Rios Marcos Tascon Krzysztof Gorynski Marcelo Cypel Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2021年第1期37-47,共11页
Development of a novel in vivo lung perfusion(IVLP)procedure allows localized delivery of high-dose doxorubicin(DOX)for targeting residual micrometastatic disease in the lungs.However,DOX delivery via IVLP requires ca... Development of a novel in vivo lung perfusion(IVLP)procedure allows localized delivery of high-dose doxorubicin(DOX)for targeting residual micrometastatic disease in the lungs.However,DOX delivery via IVLP requires careful monitoring of drug level to ensure tissue concentrations of this agent remain in the therapeutic window.A small dimension nitinol wire coated with a sorbent of biocompatible morphology(Bio-SPME)has been clinically evaluated for in vivo lung tissue extraction and determination of DOX and its key metabolites.The in vivo Bio-SPME-IVLP experiments were performed on pig model over various(150 and 225 mg/m^(2))drug doses,and during human clinical trial.Two patients with metastatic osteosarcoma were treated with a single 5 and 7 μg/mL(respectively)dose of DOX during a 3-h IVLP.In both pig and human cases,DOX tissue levels presented similar trends during IVLP.Human lung tissue concentrations of drug ranged between 15 and 293 μg/g over the course of the IVLP procedure.In addition to DOX levels,Bio-SPME followed by liquid chromatography-mass spectrometry analysis generated 64 metabolic features during endogenous metabolite screening,providing information about lung status during drug administration.Real-time monitoring of DOX levels in the lungs can be performed effectively throughout the IVLP procedure by in vivo Bio-SPME chemical biopsy approach.Bio-SPME also extracted various endogenous molecules,thus providing a real-time snapshot of the physiology of the cells,which might assist in the tailoring of personalized treatment strategy. 展开更多
关键词 In vivo solid phase microextraction Metabolite profiling Spatial resolution Therapeutic drug monitoring Tissue analysis
下载PDF
Determination of Aromatic Components of Rosa davurica Pall. by Headspace Solid Phase Microextraction Combined with GC-MS 被引量:5
5
作者 Yuan NIU Qiong XU +4 位作者 Jian ZHUANG Yude WANG Lilan DAI Dengfei LI Yalan ZHAO 《Medicinal Plant》 CAS 2018年第5期20-22,26,共4页
[Objectives] To determine the aromatic components of Rosa davurica Pall. [Methods] 42 kinds of aromatic components were identified from the flowers of R. davurica by headspace solid phase microextraction( HS-SPME) com... [Objectives] To determine the aromatic components of Rosa davurica Pall. [Methods] 42 kinds of aromatic components were identified from the flowers of R. davurica by headspace solid phase microextraction( HS-SPME) combined with gas chromatography-mass spectrometry( GC-MS). The main compounds were alcohols( 54. 88%) and aldehydes( 19. 55%). [Results] The top five components with the highest relative content were phenylethyl alcohol( 12. 69%),geraniol( 9. 85%),citronellol( 8. 80%),nerol( 7. 84%) and 2-n-pentylfuran( 7. 45%). [Conclusions] Headspace solid phase microextraction( HS-SPME) combined with gas chromatography-mass spectrometry( GC-MS) can provide basis for further development and utilization of R. davurica. 展开更多
关键词 Rosa davurica Pall. HEADSPACE solid phase microextraction (HS-SPME) Gas chromatography-mass spectrometry (GC-MS) AROMATIC COMPONENTS
下载PDF
A novel fiber coating for solid phase microextraction and its application for the extraction of n-alkane from aqueous sample 被引量:1
6
作者 HUANG Min-jia JIANG Gui-bin ZHAO Zong-shan 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2005年第6期930-932,共3页
Base on the previous work in laboratory, a novel polyaniline doped with polydimethylsiloxane coating was developed on a stainless steel wire for solid phase microextraction(SPME) by electroplating method. This elect... Base on the previous work in laboratory, a novel polyaniline doped with polydimethylsiloxane coating was developed on a stainless steel wire for solid phase microextraction(SPME) by electroplating method. This electroplating method not only has advantages of ease preparation and simple equipments required, but also increases the lifetime of the SPME fiber. The composite fiber(polyaniline/ polydimethylsiloxane(PANI/PDMS)) was evaluated by analyzing n-tridecane, n-tetradecane and n-pentadecane in aqueous sample. The new fiber coating showed comprehensive abilities to extract alkanes compounds. The relative standard deviations were found to be 6.8%-10.33%. 展开更多
关键词 solid phase microextraction stainless steel wires electroplating fiber preparation polyaniline/polydimethylsiloxane ALKANES
下载PDF
Solid phase microextraction(SPME) sampling under turbulent conditions and for the simultaneous collecting of tracer gases 被引量:1
7
作者 Underwood Susanne W. Jong Edmund C. +3 位作者 Luxbacher Kray D. Sarver Emily A. Ripepi Nino S. Mc Nair Harold M. 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2015年第4期559-563,共5页
Solid phase microextraction (SPME) is a solvent-flee method of sample collection. SPME is an appealing method for sample collection because it is designed for the sampling of trace level analytes with short sampling... Solid phase microextraction (SPME) is a solvent-flee method of sample collection. SPME is an appealing method for sample collection because it is designed for the sampling of trace level analytes with short sampling times in a variety of environments. Additionally, SPME can be used to directly deliver a sample to a gas chromatograph (GC) for analysis by means of thermal desorption. In this paper, the performance of SPME under dynamic conditions was investigated. Additionally, the competence of SPME sampling for the simultaneous analysis of multiple trace analytes was also evaluated. This work is discussed in the context of underground mine ventilation surveys but is applicable to any industry in which ventilation circuits must be evaluated. The results of this paper showed that the performance of the 100 ~m PDMS SPME fiber was both precise and rapid under dynamic conditions. This SPME fiber was also able to simultaneously collect sulfur hexafluoride (SF6) and perfluoromethylcyclohexane (PMCH) with adequate sensitivity. 展开更多
关键词 solid phase microextraction Sulfur hexafluoride Perfluoromethylcyclohexane Tracer gas Mine ventilation Air sampling
下载PDF
Preparation of polypyrrole/nanosilica composite for solid-phase microextraction of bisphenol and phthalates migrated from containers to eye drops and injection solutions 被引量:2
8
作者 Mehdi Ansari Dogaheh Mansoureh Behzadi 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2019年第3期185-192,共8页
This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized inf... This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized influencing parameters on the extraction efficiency and morphology of the nanocomposite such as deposition potential, concentration of pyrrole and polyphosphate, deposition time and the nanosilica amount. Under the optimized conditions, characterization of the nanocomposite was inves-tigated by scanning electron microscopy and Fourier transform infra-red spectroscopy. Also, the factors related to the solid-phase microextraction method including desorption temperature and time, extrac-tion temperature and time, ionic strength and pH were studied in detail. Subsequently, the proposed method was validated by gas chromatography-mass spectrometry by thermal desorption and acceptable figures of merit were obtained. The linearity of the calibration curves was between 0.01 and 50 ng/mL with acceptable correlation coefficients (0.9956-0.9987) and limits of detection were in the range 0.002-0.01 ng/mL. Relative standard deviations in terms of intra-day and inter-day by five replicate analyses from aqueous solutions containing 0.1 ng/mL of target analytes were in the range 3.3%-5.4% and 5%-7.1%, respectively. Fiber-to-fiber reproducibilities were measured for three different fibers prepared in the same conditions and the results were between 7.3% and 9.8%. Also, extraction recoveries at two different concentrations were ≥96%. Finally, the suitability of the proposed method was demonstrated through its application to the analysis of some eye drops and injection solutions. 展开更多
关键词 solid-phase microextraction Gas chromatography-mass spectrometry Polyphosphate-doped POLYPYRROLE NANOSILICA PHTHALATES BisphenolA
下载PDF
Integration of GC-MS Based Non-Targeted Metabolic Profiling with Headspace Solid Phase Microextraction Enhances the Understanding of Volatile Differentiation in Tobacco Leaves from North Carolina, India and Brazil 被引量:3
9
作者 Dong-Ming Ma Saiprasad V. S. Gandra +1 位作者 Navin Sharma De-Yu Xie 《American Journal of Plant Sciences》 2012年第12期1759-1769,共11页
In this report, gas chromatography-mass spectrometry (GC-MS) based non-targeted metabolomics is used to develop appropriate headspace solid phase microextractions (HS-SPME) to enhance the understanding of volatile com... In this report, gas chromatography-mass spectrometry (GC-MS) based non-targeted metabolomics is used to develop appropriate headspace solid phase microextractions (HS-SPME) to enhance the understanding of volatile complexity of flue-cured tobacco leaves. Non-targeted metabolic profiling of GC-MS shows that the extraction condition of HS-SPME at 100?C for 30 min provides a better metabolite profile than other extraction conditions tested. GC-MS and principal component analyses (PCA) show that among five types of fibers tested, 100 μm polydimethylsiloxane (PMDS), 65 μm polydimethylsiloxane/divinylbenzene (PMDS/DVB) and 75 μm carboxen/polydimethylsiloxane (CAR/ PMS) provide a better reproducible metabolite profile. Based on an appropriate PDMS extraction condition optimized, we use GC-MS analysis and PCA to compare metabolite profiles in flue-cured leaves of tobacco plants grown in North Carolina, India and Brazil, respectively. The resulting data of PCA show that the global metabolic profiles in North Carolina samples are separated from those in Brazil and India samples, two groups of which are characterized by a partially overlapped pattern. Several peaks that were differentially accumulated in samples were annotated to known metabolites by deconvolution analysis, such as norsolanadione, solavetivone and rishtin. Norsolanadione is detected only in Brazil samples. Solavetivone is detected in samples of India and Brazil but not in those of North Carolina. Rishtin is detected in samples of North Carolina and India but not in Brazil samples. These data indicate that not only can a non-targeted metabolic profiling approach enhance the understanding of volatile complexity, but also can identify marker volatile metabolites in tobacco leaves produced in different growth regions. 展开更多
关键词 TOBACCO HEADSPACE solid-phase microextraction Gas Chromatography Mass Spectrum VOLATILE Compounds
下载PDF
Determination of Eleutheroside B and E in Acanthopanax Preparations by High-P erformance Liquid Chromatography with Solid-Phase Extraction 被引量:6
10
作者 胡芳弟 封士兰 +2 位作者 赵健雄 陈立仁 徐静汶 《Journal of Chinese Pharmaceutical Sciences》 CAS 2005年第1期51-55,共5页
Aim An HPLC method for analyzing eleutheroside B (ELU B) and eleutheroside E(ELU E) , two of the main active substances of Acanthopanax preparations were studied. Methods Thesamples were analyzed on a kromasil ODS col... Aim An HPLC method for analyzing eleutheroside B (ELU B) and eleutheroside E(ELU E) , two of the main active substances of Acanthopanax preparations were studied. Methods Thesamples were analyzed on a kromasil ODS column with water-acetonitrile as a gradient mobile phase.The flow rate was 0.8 mL·min^(-1) and detecting wavelengths were 206 nm for ELU B, 220 nm for ELUE, solid phase extraction (SPE) and internal standard-salicin were selected. Results The recoveriesof Acanthopanax tablets and injection were 90.4% - 96.8% and 96.4% - 99.8% for ELU B, 87.7% -93.3%and 95.7% - 98.5% for ELU E, respectively. The linear ranges were 4.45 - 22.25 μg· mL^(-1) (r =0.999 8) and 5.11 - 25.55 μg·mL^(-1) ( r = 0.999 7) respectively. Conclusion This method can savethe time for cleaning the chromatographic system and improve sensitivity for Acanthopanaxpreparations , thus providing a way to evaluate the quality of Acanthopanax preparations. 展开更多
关键词 eleutherosides acanthopanax preparations HPLC solid phase extraction
下载PDF
Flash Evaporation and Headspace Solid-phase Microextraction for the Analysis of the Essential Oils in Traditional Chinese Medicine,Houttuynia Cordata Thunb 被引量:1
11
作者 MinMinLIANG MeiLingQI RuoNongFU 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第5期659-662,共4页
We have investigated the use of flash evaporation, headspace solid-phase microextraction (HS-SPME) and steam distillation (SD) as sample concentration and preparation techniques for the analysis of volatile constituen... We have investigated the use of flash evaporation, headspace solid-phase microextraction (HS-SPME) and steam distillation (SD) as sample concentration and preparation techniques for the analysis of volatile constituents present in Houttuynia cordata Thunb. The samples were analyzed by gas chromatography (GC) and identified by mass spectrometry (MS). Comparison studies were performed. It was found that the results obtained between Headspace solid-phase microextraction HS-SPME and SD techniques were in good agreement. Seventy-nine compounds in Houttuynia cordata Thunb were identified by MS. In flash evaporation, thirty-nine compounds were identified. Discrimination in the response for many constituents studied was not observed, which can be clearly observed in SD and HS-SPME techniques. As a conclusion, HS-SPME is a powerful tool for determining the volatile constitutes present in the Houttuynia cordata. 展开更多
关键词 Headspace solid-phase microextraction flash evaporation essential oils GC-MS.
下载PDF
Determination of volatile organic compounds in river water by solid phase extraction and gas chromatography 被引量:4
12
作者 M.A.Mottaleb M.Z.Abedin M.S.Islam 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2004年第3期497-501,共5页
A simple, rapid, and reproducible method is described employing solid phase extraction(SPE) using dichloromethane followed by gas chromatography(GC) with flame ionization detection(FID) for determination of volatile ... A simple, rapid, and reproducible method is described employing solid phase extraction(SPE) using dichloromethane followed by gas chromatography(GC) with flame ionization detection(FID) for determination of volatile organic compound(VOC) from the Buriganga River water of Bangladesh. The method was applied to detect the benzene, toluene, ethylbenzene, xylene and cumene(BTEXC) in the sample collected from the surface or 15 cm depth of water. Two hundred ml of n hexane pretreated and filtered water samples were applied directly to a C 18 SPE column. BTEXC were extracted with dichloromethane and average concentrations were obtained as 0 104 to 0 372 μg/ml. The highest concentration of benzene was found as 0 372 μg/ml with a relative standard deviation(RSD) of 6 2%, and cumene was not detected. Factors influencing SPE e.g., adsorbent types, sample load volume, eluting solvent, headspace and temperatures, were investigated. A cartridge containing a C 18 adsorbent and using dichloromethane gave better performance for extraction of BTEXC from water. Average recoveries exceeding 90% could be achieved for cumene at 4℃ with a 2 7% RSD. 展开更多
关键词 solid phase extraction river water environmental analysis VOC recoveries
下载PDF
Determination of Melamine in Fresh Milk by Electrochemistry with Solid Phase Microextraction at Bismuthyl Chloride Modified Graphite Epoxy Composite Electrode
13
作者 Yongchun Zhu Yanjia Zhang +3 位作者 Jingyi Li Yanli Han Guobin Dong Hongbo Zhang 《American Journal of Analytical Chemistry》 2011年第5期612-618,共7页
Melamine as an important chemical raw material and a harmful additive in foods has attracted many people’s attention. In the present paper, The graphite-epoxy composited solid phase electrode was modified with bismut... Melamine as an important chemical raw material and a harmful additive in foods has attracted many people’s attention. In the present paper, The graphite-epoxy composited solid phase electrode was modified with bismuth layer by cyclic voltammetric deposition of bismuth from Bi(NO3)3 aqueous solution including 0.10 M HNO3, and hydrolyzed into micro bismuthyl chloride on-sites. Melamine in fresh milk was extracted with solid phase micro-extraction on the bismuthyl chloride modified graphite-epoxy composited solid electrode. The adsorption of melamine on bismuthyl chloride particle surfaces follows a Freundlich adsorption model, and results in the decrease of the reduction peak current of bismuth in bismuthyl chloride, and determined by differential pulse voltammetry from fresh milk in a larger concentration range of 10–4 ? 10–12 M with detection limit of 2.5 ? 10–12 M and relative standard deviation of 2.7%. The method is sensitive, convenient and was applied in the detection of melamine in fresh milk with relative deviation of 4.2% in content of 0.45 mg/kg melamine in the fresh milk. 展开更多
关键词 MELAMINE Bismuthyl CHLORIDE Modified ELECTRODE Adsorption Differential PULSE VOLTAMMETRY solid phase Micro extraction
下载PDF
Application of Phenyl Bonded Mesoporous Silica as A Novel Coating Layer of Solid-phase Microextraction for Determination of Benzo[a]pyrene in Water Samples
14
作者 XinZhenDU YaRongWANG QianMA XueFengMAO JinGuoHOU 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第6期801-804,共4页
Phenyl bonded mesoporous silica (C6H5-MCM-41) was applied as the fiber coating of solid-phase microextraction (SPME). The performance of the fiber coating was discussed coupling to HPLC. Applicability of mesoporous fi... Phenyl bonded mesoporous silica (C6H5-MCM-41) was applied as the fiber coating of solid-phase microextraction (SPME). The performance of the fiber coating was discussed coupling to HPLC. Applicability of mesoporous fiber coating was examined for the determination of benzo[a]pyrene (B[a]P) in water samples. The limit of detection (LOD) is 0.28μg·L-1. Good recovery and relative standard deviation (RSD) were obtained. 展开更多
关键词 Mesoporous silica solid-phase microextraction HPLC benzo[a]pyrene.
下载PDF
Solid-phase Microextraction with Benzoxy-calix[6]arene Fiber Coupled to Gas Chromatography for the Analysis of Polycyclic Aromatic Hydrocarbons in Water
15
作者 YE Chang-wen ZHANG Xue-na HUANG Jiang-yan LI Xiu-juan PAN Si-yi 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第2期198-202,共5页
Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seve... Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seven polycyclic aromatic hydrocarbons(PAHs) in water. The novel SPME fiber exhibited higher extraction efficiency to PAHs compared with poly(dimethylsiloxane) and other calixarene-containing fibers. Extraction/retention mechanism based on the interactions between calixarenes and PAHs was discussed. Owing to the good selectivity and high extraction capability of this calixarene fiber, low detection limits were obtained in a range of 0.34―6.50 ng/L and the relative standard deviation values were ≤12.3% for all of the analytes. The linear ranges of the proposed method were five orders of magnitude for the tested compounds, with linear correlation coefficients(r) greater than 0.998. The method was applied to the determination of polycyclic aromatic hydrocarbons in nine water sources in Wuhan City, China. Standard addition method was selected for the quantification and the recovery values were in a satisfactory range. Total PAHs concentrations in the nine surface water samples were found to vary between undetectable and 8.840 μg/L with two- and three-ring PAHs predominating. 展开更多
关键词 Polycyclic aromatic hydrocarbon solid-phase microextraction CALIXARENE Gas chromatography WATER
下载PDF
Sol-Gel-Coated Calix[4]arene Fiber for Solid-Phase Microextraction
16
作者 LiXiu-juan XiaoRui-min +1 位作者 LiHai-bing ZengZhao-rui 《Wuhan University Journal of Natural Sciences》 CAS 2003年第04A期1153-1155,共3页
5, 11, 17, 23-tetra-tert-butyl-25, 27-diethoxy-26, 28-dihydroxycalix \ arene /hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction with sol-gel technology. The pr... 5, 11, 17, 23-tetra-tert-butyl-25, 27-diethoxy-26, 28-dihydroxycalix \ arene /hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction with sol-gel technology. The properties of the new coating were investigated by analysis of benzene derivatives, polycyclic aromatic hydrocarbons and aromatic amines. The fiber is characterized by good sensitivity and selectivity to these aromatics. The fiber has stable performance at a high temperature of 380℃ and after a long solvent immersing, thus its lifetime is very long. It shows good fiber-to-fiber and batch-to-batch reproducibility. Furthermore, broad linear ranges and low detection limits are also its characteristics. 展开更多
关键词 solid-phase microextraction SOL-GEL CALIXARENE aromatic compounds
下载PDF
Preparation of A New Fiber by Sol-gel Technology in Solid-phase Microextraction (SPME)
17
作者 LiMingWEI QingYuOU JuBaiLI 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第9期1127-1130,共4页
The sol-gel technology is applied for the preparation of solid-phase microextraction (SPME) fiber. The fiber demonstrates high thermal stability, efficient extraction rate and the selectivity for non-polar or low-pol... The sol-gel technology is applied for the preparation of solid-phase microextraction (SPME) fiber. The fiber demonstrates high thermal stability, efficient extraction rate and the selectivity for non-polar or low-polar analytes. Efficient SPME-GC-FID analyses of benzene- toluene-ethylbenzene-xylenes (BTEXs) and low-polar halocarbon were achieved by the sol-gel coated DSDA-DDBT-TiO2 fiber. Some parameters of the SPME fiber for the determination of halocarbon in aqueous sample were investigated. 展开更多
关键词 solid-phase microextraction sol-gel technology SELECTIVITY polyimide (DSDA-DDBT).
下载PDF
Synthesis and Solid Phase Extraction Performance Study of NNAL-specific Molecularly Imprinted Polymers Using Dummy Templates 被引量:2
18
作者 张志丹 郑赛晶 +3 位作者 杨俊 王维妙 刘百战 朱晓兰 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2013年第3期361-368,I0004,共9页
Dummy molecularly imprinted polymers (DMIPs) for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) were produced using three structural analogues as dummy template molecules. The chosen analogues were 4-(a... Dummy molecularly imprinted polymers (DMIPs) for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) were produced using three structural analogues as dummy template molecules. The chosen analogues were 4-(acetymethylamino)-1-(3-pyridyl)-butanol, 4- (methylamino)-1-(3-pyridyl)-1-butanol, and 1-(3-pyridyl)-1,4,-butanediol. The molecular recognition characteristics of the produced polymers were evaluated by X-ray photoelec- tron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FT-IR). Interactions between NNAL and methacrylic acid should be cooperative hydrogen bonds while the ni- trogen atom of the pyridine ring and the oxygen atom of the nitroso group in NNAL are two of the hydrogen-bond acceptors. It was further demonstrated that DMIP synthesized by 4-(acetymethylamino)-1-(3-pyridyl)-butanol had the best binding performance by XPS and FT-IR. Then dummy molecularly imprinted solid phase extraction (DMISPE) was developed for the determination of the analyte using the hit polymer as the sorbing material. Under optimal conditions, the recovery of NNAL dissolved in standard solution reached 93%. And the investigated polymer exhibited much higher binding of NNAL when nicotine was acted as the competitive molecule. Also the proposed method was applied to the measurement of NNAL spiked in blank urine samples with recoveries ranging from 87.2% to 101.2%. 展开更多
关键词 Molecularly imprinted polymer Dummy template 4-(Methylnitrosamino)-1-(3-pyridyl)-1-butanol solid phase extraction
下载PDF
Determination of resveratrol in red wine by solid phase extraction-flow injection chemiluminescence method 被引量:7
19
作者 Juan Juan Ren Hai Yan Liu +2 位作者 Yu Hong Hao Pin Gang He Yu Zhi Fang 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第8期985-988,共4页
A sensitive flow injection chemiluminescence method has been developed for the detection of resveratrol in red wine based on the fact that resveratrol can greatly enhance chemiluminescence reaction between KMnO4 and H... A sensitive flow injection chemiluminescence method has been developed for the detection of resveratrol in red wine based on the fact that resveratrol can greatly enhance chemiluminescence reaction between KMnO4 and HCHO in sulfuric acid medium. Analytes were pre-concentrated on solid sorbents (C18 solid-phase extraction cartridges). Under the optimum conditions, the proposed method allows the measurement of resveratrol over the range of 1.32 × 10^-8 to 1.32 × 10^-5 mol/L with a detection limit of 3.30 ×10^-9 mol/L, and the relative standard deviation for 1.32 ×10^-5 mol/L resveratrol (n = 11) is 3.8%. This method has been successfully applied for the determination of the resveratrol in red wine. Furthermore, the possible reaction mechanism was also discussed. 展开更多
关键词 RESVERATROL solid phase extraction How-injection chemiluminescence Potassium permanganate FORMALDEHYDE
下载PDF
Influences of solid particles on the formation of the third phase crud during solvent extraction 被引量:6
20
作者 ZHENG Qi RUAN Renman WEN Jiankang SONG Yongsheng DONG Qinghai WU Minglin YAO Guocheng 《Rare Metals》 SCIE EI CAS CSCD 2007年第1期89-96,共8页
The influences of solid particles in leach solution on the formation of the third phase crud during solvent extraction of copper were studied. Analyzed from the point of view of pH value and surface tension, the study... The influences of solid particles in leach solution on the formation of the third phase crud during solvent extraction of copper were studied. Analyzed from the point of view of pH value and surface tension, the study results showed that the solid particle is one of the most important contributors for the formation of the third phase crud. During solvent extraction, if the pH value was greater than 2.30, the number of solid particles in the mother solution increased, in which case the possibility of forming the third phase crud could also increase, and the interface tension value might grow in pace with the quantity of the third phase crud. 展开更多
关键词 solvent extraction solid particle the third phase crud surface tension
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部