Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tr...Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tra- ditional LLE method. High performance thin layer chromatography (HPTLC) has several advantages over TLC. The present work studied the higher efficiency of a new SPE-HPTLC method over that of a routine LLE-TLC method, in extraction and detection of urinary morphine. Fifty-eight urine samples, primarily identified as mor- phine-positive samples by a strip test, 'were re-screened by LLE-TLC and SPE-HPTLC. The results of LLE-TLC and SPE-HPTLC were then compared with each other. The results showed that the SPE-HPTLC detected 74% of total samples as morphine-positive samples whereas the LLE-TLC detected 48% of the same samples. We further discussed the effect of codeine abuse on TLC analysis of urinary morphine. Regarding the importance of morphine detection in urine, the present combined SPE-HPTLC method is suggested as a replacement method for detection of urinary morphine by many reference laboratories.展开更多
The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples...The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.展开更多
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first...To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).展开更多
A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithe...A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithelantha micromeris. Purification of GA4 was carried out by solid phase extraction (SPE), in Epithelantha micromeris. In the chromatography method was obtaining a retention time of 2.1 min, using Hypersil GOLD C-18 column (100 × 4.6 mm dim and size particle 5 μ), mobile phase 50/50 acetonitrile/water and a flow 1.0 ml/min. Detection was carried out by a UV detector set at 205 nm, and a quantization limit of 0.4 mg/L. The obtained correlation coefficient was 0.995.展开更多
An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matog...An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products.展开更多
A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet de...A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.展开更多
[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norf...[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norfloxacin, ciprofloxacin, Iomefloxacin and enrofloxacin) were pre- pared. The detection limit in water and recovery were determined. The water samples collected from different areas, river and tap water were trea- ted using solid-phese extraction method and analyzed by high performance liquid chromatography. Then the concentration of quinolones antibiotics was determined by fluorescence method. [ Result] The detection limit of quinolone antibiotics in water was 0.083 -0.248 μg/L, and their recovery was 63.7% -134.1%. The four quinolone antibiotics at different levels were detected in various water samples, and the total concentration of quin- olone antibiotics was 0.045 -3.969 μg/L. The total concentration of quinolone antibiotics was higher in the water samples collected from rivers in Shenzhen area than in the sewage samples. The four quinolone antibiotics could be detected in all tap water samples. [ CoaduLsion ] The solid phase extraction-high performance liquid chromatography-fluorescence method is feasible and effective to detect quinolones in water. In addition, this method needs low cost and can meet requirements of daily monitorina and analysis.展开更多
2,4,6-trichlorophenol molecularly imprinted suspension polymer has been prepared and applied to the molecularly imprinted micro-solid-phase extraction procedure for selective preconcentration of phenolic compounds fro...2,4,6-trichlorophenol molecularly imprinted suspension polymer has been prepared and applied to the molecularly imprinted micro-solid-phase extraction procedure for selective preconcentration of phenolic compounds from environmental water samples. The influence of functional monomer, cross-linker, polymerization condition, porogen, and the ratio of template molecule and functional monomer to cross-linker on the size of the obtained particles were investigated. It was found that methyacrylic acid as functional monomer, divinylbenzene as cross-linker, the molar ratio of template molecule and functional monomer to cross-linker was 1:4:20, the amount of AIBN was 100 mg, ultraviolet radiation at 365 nm were the optimal conditions, and at these conditions, the polymers had the best adsorption efficiency and had the monodispersity of 2 - 3 μm microsphere particles. The characteristics of the MIMSPE method were valid by high performance liquid chromatography. This MIMSPE-HPLC method has been successfully applied to the direct preconcentration and determination of phenolic compounds (phenol, 4-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol) in environmental water samples.展开更多
A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxyte...A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and their 4-epimers (4-epiTCs) in agricultural soil fertilized with swine manure. Soil samples were extracted and cleaned-up with 10 mL EDTA-McIlvaine buffer solution (pH 4.0), then cleaned-up and pre-concentrated using the Oasis MAX cartridge and then eluted with 1 mL solution by mixing formic acid, methanol and water at a ratio of 2:15:83 (v/v/v). The purified samples were separated by an ACQUITY UPLC BEH C18 column using acetonitrile and water containing 0.1% formic acid mobile phase and detected by a single quadrupole MS. The limits of detection for the soil extraction method (LODsoil) ranged from 0.6-2.5 lag kg-~ with recoveries from 23.3-159.2%. Finally, the method was applied to an agricultural field in an area with intensive pig-fattening farming. Tetracyclines were detected in soil from 2.8 to 42.4 μg kg-1 soil. These results demonstrate that soil from swine farms can become severely contaminated with tetracycline antibiotics and their metabolites.展开更多
Surface molecularly imprinted polymers (SMIPs) for selective adsorption of ampicillin sodium were synthesized using surface molecular imprinting technique with silica gel as a support. The physical and morphological...Surface molecularly imprinted polymers (SMIPs) for selective adsorption of ampicillin sodium were synthesized using surface molecular imprinting technique with silica gel as a support. The physical and morphological characteristics of the polymers were investigated by scanning electron microscope (SEM), Fourier transform infrared spectroscopy (FT-IR), thermogravimetric analysis (TGA), elemental analysis and nitrogen adsorption-desorption test. The obtained results showed that the SMIPs displayed great adsorption capacity (13.5 lag/mg), high recognition ability (the imprinted factor is 3.2) and good binding kinetics for ampicillin sodium. Finally, as solid phase extraction adsorbents, the SMIPs coupled with HPLC method were validated and applied for the enrichment, purification and determination of anapicillin sodium in real milk and blood samples. The averages of spiked accuracy ranged from 92.1% to 107.6%. The relative standard deviations of intra- and inter-day precisions were less than 4.6%. This study provides a new and promising method for enriching, extracting and determining ampicillin sodium in complex biological samples.展开更多
A reliable,selective and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of lamotrigine in human plasma using lamotrigine13C3,d3 as an internal standa...A reliable,selective and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of lamotrigine in human plasma using lamotrigine13C3,d3 as an internal standard.Analyte and internal standard were extracted from human plasma by solid-phase extraction and detected in positive ion mode by tandem mass spectrometry with electrospray ionization(ESI) interface.Chromatographic separation was performed on a Chromolith s SpeedROD;RP-18e column(50-4.6 mm i.d.) using acetonitrile:570.1 mM ammonium formate solution(90:10,v/v) as the mobile phase at a flow rate of 0.500 mL/min.The calibration curves were linear over the range of 5.02-1226.47 ng/mL with the lower limit of quantitation validated at 5.02 ng/mL.The analytes were found stable in human plasma through three freeze(-20℃)-thaw(ice-cold water bath) cycles and under storage on bench-top in ice-cold water bath for at least 6.8 h,and also in the mobile phase at 10℃ for at least 57h.The method has shown good reproducibility,as the intra-and inter-day precisions were within 3.0%,while the accuracies were within 76.0% of nominal values.The validated LC-MS/MS method was applied for the evaluation of pharmacokinetic and bioequivalence parameters of lamotrigine after an oral administration of 50mg lamotrigine tablet to thirty-two healthy adult male volunteers.展开更多
The comparison of solid phase extraction(SPE) for the preconcentration and isolation of polyphenols in tobacco samples was carried out by ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC/...The comparison of solid phase extraction(SPE) for the preconcentration and isolation of polyphenols in tobacco samples was carried out by ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) and multivariate analysis.Several adsorbing materials of SPE(C18,NH2,SAX and OASIS) were investigated.It was found that the C18 and OASIS cartridges can not only speed up the purification process,but also simplify the SPE operation.A UPLC/MS/MS was used for the determination of polyphenols in tobacco samples after purification.All analytes were separated and determined in 2min.The limit of detection was 0.05 ng/mL.Cluster analysis(CA) and principal component analysis(PCA) were used for the analysis of 4 varieties(flue-cured tobacco,oriental tobacco,sun-cured tobacco and burley) in order to interpret the effect of planting and machining process on the concentration of polyphenols.The different types of tobacco samples could be easily clustered by CA.PCA on the chemical composition of tobacco resulted in two principal components(PCs) that take 84.2% of the total variance.The PCA and CA indicate that the polyphenols can be used for distinguishing tobacco types.展开更多
Eighteen sex hormones in antler velvet were determined by high performance liquid chromatography tandem mass spectrometry.The solid phase extraction was applied to eliminating the matrix effect.The experimental condit...Eighteen sex hormones in antler velvet were determined by high performance liquid chromatography tandem mass spectrometry.The solid phase extraction was applied to eliminating the matrix effect.The experimental conditions were examined and optimized.Under the optimal conditions,the proposed method provides the good linearities and determination limits(0.2―1.0 μg/kg) of the analytes investigated.The recoveries ranging from 72.3% to 149.5% were obtained for the target analytes at two concentration levels.This method was applied to the determination of eighteen sex hormones in different kinds of antler velvet samples and the obtained results are satisfactory.The results indicate that the proposed method is suitable for the determination of sex hormones in antler velvet samples.展开更多
Matrix solid-phase dispersion(MSPD) was developed for the extraction of four alkaloids, including aconitine, mesaconitine, hypaconitine and deoxyaconitine, from the roots ofAconitum kusnezoffii Reichb. The determina...Matrix solid-phase dispersion(MSPD) was developed for the extraction of four alkaloids, including aconitine, mesaconitine, hypaconitine and deoxyaconitine, from the roots ofAconitum kusnezoffii Reichb. The determination of the analyte was carried out by high performance liquid chromatography with UV detection. The alkaline alumina was used as sorbent. The mixture of acetonitrile and water was used as elution solvent. Several extraction parameters, such as type of sorbent, the ratio of sample to solid support material, type of the elution solvent and the volume of the elution solvent were tested. Mean recoveries ranged from 93.16% to 102.73%, with relative standard deviations from 0.27% to 4.17%. With the extraction efficiency and time expenditure taken into account, MSPD extraction should be a comparatively good method.展开更多
An analytical method based on solid phase extraction was developed and validated for analysis of adefovir in human plasma. Adefovir-d4 was used as an internal standard and Synergi MAX RP80A (150rnmx4.6mm. 41am) colu...An analytical method based on solid phase extraction was developed and validated for analysis of adefovir in human plasma. Adefovir-d4 was used as an internal standard and Synergi MAX RP80A (150rnmx4.6mm. 41am) column provided the desired chromatographic separation of compounds followed by detection with mass spectrometry. The method used simple isocratic chromato- graphic condition and mass spectrometric detection in the positive ionization mode. The calibration cuives were linear over the range of 0.50-42.47 ng/mL with the lower limit of quantitation validated at 0.50 ng/mL. Matrix effect was assessed by post-column infusion experiment to monitor phospholipids and post- extraction addition experiment was performed. The degree of matrix effect for adefovir was determined as 7.5% and ion-enhancement in five different lots of human plasma was 7.1% and had no impact on study samples analysis with 4.5 rain run time. The intra- and inter-day precision values were within 7.7% and 7.8%, respectively, for adefovir at the lower limit of quantification level. Validated bioanalytical method was successfully applied to clinical sample analysis.展开更多
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established....A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.展开更多
文摘Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tra- ditional LLE method. High performance thin layer chromatography (HPTLC) has several advantages over TLC. The present work studied the higher efficiency of a new SPE-HPTLC method over that of a routine LLE-TLC method, in extraction and detection of urinary morphine. Fifty-eight urine samples, primarily identified as mor- phine-positive samples by a strip test, 'were re-screened by LLE-TLC and SPE-HPTLC. The results of LLE-TLC and SPE-HPTLC were then compared with each other. The results showed that the SPE-HPTLC detected 74% of total samples as morphine-positive samples whereas the LLE-TLC detected 48% of the same samples. We further discussed the effect of codeine abuse on TLC analysis of urinary morphine. Regarding the importance of morphine detection in urine, the present combined SPE-HPTLC method is suggested as a replacement method for detection of urinary morphine by many reference laboratories.
基金This work was supported by“National Key Research and Development Program of China”(Project No.2018YFC1603400)Science and Technology Program of Hebei Province(Project No.19225503D).
文摘The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.
文摘To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).
文摘A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithelantha micromeris. Purification of GA4 was carried out by solid phase extraction (SPE), in Epithelantha micromeris. In the chromatography method was obtaining a retention time of 2.1 min, using Hypersil GOLD C-18 column (100 × 4.6 mm dim and size particle 5 μ), mobile phase 50/50 acetonitrile/water and a flow 1.0 ml/min. Detection was carried out by a UV detector set at 205 nm, and a quantization limit of 0.4 mg/L. The obtained correlation coefficient was 0.995.
基金Supported by the Science and Technology Plan of Liaoning Province, China(No.2006226002)the Project of the Doctor Fund of Hebei University of Science and Technology, China(No.005121)
文摘An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products.
基金This research was supported by Special Research Fund for Young Doctors of Qiqihar Medical University(QMSI2020B-03,hosted by Wenjing Li).
文摘A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.
基金funded by the grants from the China Natural Science Foundation ( 30671208 and 40773062)Key Project of Guangdong Natural Science Foundation ( 07117909)Science and Technology Planning Project of Guangdong Province( 2005B20801002 and 2006B20601003)
文摘[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norfloxacin, ciprofloxacin, Iomefloxacin and enrofloxacin) were pre- pared. The detection limit in water and recovery were determined. The water samples collected from different areas, river and tap water were trea- ted using solid-phese extraction method and analyzed by high performance liquid chromatography. Then the concentration of quinolones antibiotics was determined by fluorescence method. [ Result] The detection limit of quinolone antibiotics in water was 0.083 -0.248 μg/L, and their recovery was 63.7% -134.1%. The four quinolone antibiotics at different levels were detected in various water samples, and the total concentration of quin- olone antibiotics was 0.045 -3.969 μg/L. The total concentration of quinolone antibiotics was higher in the water samples collected from rivers in Shenzhen area than in the sewage samples. The four quinolone antibiotics could be detected in all tap water samples. [ CoaduLsion ] The solid phase extraction-high performance liquid chromatography-fluorescence method is feasible and effective to detect quinolones in water. In addition, this method needs low cost and can meet requirements of daily monitorina and analysis.
文摘2,4,6-trichlorophenol molecularly imprinted suspension polymer has been prepared and applied to the molecularly imprinted micro-solid-phase extraction procedure for selective preconcentration of phenolic compounds from environmental water samples. The influence of functional monomer, cross-linker, polymerization condition, porogen, and the ratio of template molecule and functional monomer to cross-linker on the size of the obtained particles were investigated. It was found that methyacrylic acid as functional monomer, divinylbenzene as cross-linker, the molar ratio of template molecule and functional monomer to cross-linker was 1:4:20, the amount of AIBN was 100 mg, ultraviolet radiation at 365 nm were the optimal conditions, and at these conditions, the polymers had the best adsorption efficiency and had the monodispersity of 2 - 3 μm microsphere particles. The characteristics of the MIMSPE method were valid by high performance liquid chromatography. This MIMSPE-HPLC method has been successfully applied to the direct preconcentration and determination of phenolic compounds (phenol, 4-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol) in environmental water samples.
文摘A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and their 4-epimers (4-epiTCs) in agricultural soil fertilized with swine manure. Soil samples were extracted and cleaned-up with 10 mL EDTA-McIlvaine buffer solution (pH 4.0), then cleaned-up and pre-concentrated using the Oasis MAX cartridge and then eluted with 1 mL solution by mixing formic acid, methanol and water at a ratio of 2:15:83 (v/v/v). The purified samples were separated by an ACQUITY UPLC BEH C18 column using acetonitrile and water containing 0.1% formic acid mobile phase and detected by a single quadrupole MS. The limits of detection for the soil extraction method (LODsoil) ranged from 0.6-2.5 lag kg-~ with recoveries from 23.3-159.2%. Finally, the method was applied to an agricultural field in an area with intensive pig-fattening farming. Tetracyclines were detected in soil from 2.8 to 42.4 μg kg-1 soil. These results demonstrate that soil from swine farms can become severely contaminated with tetracycline antibiotics and their metabolites.
基金financially supported by the National Natural Science Foundation of China (Nos. 81573391 and 81173024)the National Key Projects of China (No. 812277802)
文摘Surface molecularly imprinted polymers (SMIPs) for selective adsorption of ampicillin sodium were synthesized using surface molecular imprinting technique with silica gel as a support. The physical and morphological characteristics of the polymers were investigated by scanning electron microscope (SEM), Fourier transform infrared spectroscopy (FT-IR), thermogravimetric analysis (TGA), elemental analysis and nitrogen adsorption-desorption test. The obtained results showed that the SMIPs displayed great adsorption capacity (13.5 lag/mg), high recognition ability (the imprinted factor is 3.2) and good binding kinetics for ampicillin sodium. Finally, as solid phase extraction adsorbents, the SMIPs coupled with HPLC method were validated and applied for the enrichment, purification and determination of anapicillin sodium in real milk and blood samples. The averages of spiked accuracy ranged from 92.1% to 107.6%. The relative standard deviations of intra- and inter-day precisions were less than 4.6%. This study provides a new and promising method for enriching, extracting and determining ampicillin sodium in complex biological samples.
文摘A reliable,selective and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of lamotrigine in human plasma using lamotrigine13C3,d3 as an internal standard.Analyte and internal standard were extracted from human plasma by solid-phase extraction and detected in positive ion mode by tandem mass spectrometry with electrospray ionization(ESI) interface.Chromatographic separation was performed on a Chromolith s SpeedROD;RP-18e column(50-4.6 mm i.d.) using acetonitrile:570.1 mM ammonium formate solution(90:10,v/v) as the mobile phase at a flow rate of 0.500 mL/min.The calibration curves were linear over the range of 5.02-1226.47 ng/mL with the lower limit of quantitation validated at 5.02 ng/mL.The analytes were found stable in human plasma through three freeze(-20℃)-thaw(ice-cold water bath) cycles and under storage on bench-top in ice-cold water bath for at least 6.8 h,and also in the mobile phase at 10℃ for at least 57h.The method has shown good reproducibility,as the intra-and inter-day precisions were within 3.0%,while the accuracies were within 76.0% of nominal values.The validated LC-MS/MS method was applied for the evaluation of pharmacokinetic and bioequivalence parameters of lamotrigine after an oral administration of 50mg lamotrigine tablet to thirty-two healthy adult male volunteers.
基金Supported by the Foundation of State Tabacco Monopoly Bureau(China) in Research Project(No.110200902008)
文摘The comparison of solid phase extraction(SPE) for the preconcentration and isolation of polyphenols in tobacco samples was carried out by ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) and multivariate analysis.Several adsorbing materials of SPE(C18,NH2,SAX and OASIS) were investigated.It was found that the C18 and OASIS cartridges can not only speed up the purification process,but also simplify the SPE operation.A UPLC/MS/MS was used for the determination of polyphenols in tobacco samples after purification.All analytes were separated and determined in 2min.The limit of detection was 0.05 ng/mL.Cluster analysis(CA) and principal component analysis(PCA) were used for the analysis of 4 varieties(flue-cured tobacco,oriental tobacco,sun-cured tobacco and burley) in order to interpret the effect of planting and machining process on the concentration of polyphenols.The different types of tobacco samples could be easily clustered by CA.PCA on the chemical composition of tobacco resulted in two principal components(PCs) that take 84.2% of the total variance.The PCA and CA indicate that the polyphenols can be used for distinguishing tobacco types.
基金Supported by the Projects of the General Administration of Quality Supervision,Inspection and Quarantine of China(No.2007IK157)
文摘Eighteen sex hormones in antler velvet were determined by high performance liquid chromatography tandem mass spectrometry.The solid phase extraction was applied to eliminating the matrix effect.The experimental conditions were examined and optimized.Under the optimal conditions,the proposed method provides the good linearities and determination limits(0.2―1.0 μg/kg) of the analytes investigated.The recoveries ranging from 72.3% to 149.5% were obtained for the target analytes at two concentration levels.This method was applied to the determination of eighteen sex hormones in different kinds of antler velvet samples and the obtained results are satisfactory.The results indicate that the proposed method is suitable for the determination of sex hormones in antler velvet samples.
基金Supported by the Projects in the National Science & Technology Pillar Program During the Eleventh Five-Year Plan Period of China(No 2006BAI14B01)
文摘Matrix solid-phase dispersion(MSPD) was developed for the extraction of four alkaloids, including aconitine, mesaconitine, hypaconitine and deoxyaconitine, from the roots ofAconitum kusnezoffii Reichb. The determination of the analyte was carried out by high performance liquid chromatography with UV detection. The alkaline alumina was used as sorbent. The mixture of acetonitrile and water was used as elution solvent. Several extraction parameters, such as type of sorbent, the ratio of sample to solid support material, type of the elution solvent and the volume of the elution solvent were tested. Mean recoveries ranged from 93.16% to 102.73%, with relative standard deviations from 0.27% to 4.17%. With the extraction efficiency and time expenditure taken into account, MSPD extraction should be a comparatively good method.
基金support and facilities received from Ranbaxy Research Laboratories Gurgaon,India
文摘An analytical method based on solid phase extraction was developed and validated for analysis of adefovir in human plasma. Adefovir-d4 was used as an internal standard and Synergi MAX RP80A (150rnmx4.6mm. 41am) column provided the desired chromatographic separation of compounds followed by detection with mass spectrometry. The method used simple isocratic chromato- graphic condition and mass spectrometric detection in the positive ionization mode. The calibration cuives were linear over the range of 0.50-42.47 ng/mL with the lower limit of quantitation validated at 0.50 ng/mL. Matrix effect was assessed by post-column infusion experiment to monitor phospholipids and post- extraction addition experiment was performed. The degree of matrix effect for adefovir was determined as 7.5% and ion-enhancement in five different lots of human plasma was 7.1% and had no impact on study samples analysis with 4.5 rain run time. The intra- and inter-day precision values were within 7.7% and 7.8%, respectively, for adefovir at the lower limit of quantification level. Validated bioanalytical method was successfully applied to clinical sample analysis.
文摘A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.