期刊文献+
共找到3,139篇文章
< 1 2 157 >
每页显示 20 50 100
Solid phase microextraction(SPME) sampling under turbulent conditions and for the simultaneous collecting of tracer gases 被引量:1
1
作者 Underwood Susanne W. Jong Edmund C. +3 位作者 Luxbacher Kray D. Sarver Emily A. Ripepi Nino S. Mc Nair Harold M. 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2015年第4期559-563,共5页
Solid phase microextraction(SPME) is a solvent-free method of sample collection. SPME is an appealing method for sample collection because it is designed for the sampling of trace level analytes with short sampling ti... Solid phase microextraction(SPME) is a solvent-free method of sample collection. SPME is an appealing method for sample collection because it is designed for the sampling of trace level analytes with short sampling times in a variety of environments. Additionally, SPME can be used to directly deliver a sample to a gas chromatograph(GC) for analysis by means of thermal desorption. In this paper, the performance of SPME under dynamic conditions was investigated. Additionally, the competence of SPME sampling for the simultaneous analysis of multiple trace analytes was also evaluated. This work is discussed in the context of underground mine ventilation surveys but is applicable to any industry in which ventilation circuits must be evaluated. The results of this paper showed that the performance of the 100 lm PDMS SPME fiber was both precise and rapid under dynamic conditions. This SPME fiber was also able to simultaneously collect sulfur hexafluoride(SF6) and perfluoromethylcyclohexane(PMCH) with adequate sensitivity. 展开更多
关键词 固相微萃取技术 spme 采样时间 示踪气体 收集 湍流 矿井通风 萃取纤维
下载PDF
Preparation of A New Fiber by Sol-gel Technology in Solid-phase Microextraction (SPME)
2
作者 LiMingWEI QingYuOU JuBaiLI 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第9期1127-1130,共4页
The sol-gel technology is applied for the preparation of solid-phase microextraction (SPME) fiber. The fiber demonstrates high thermal stability, efficient extraction rate and the selectivity for non-polar or low-pol... The sol-gel technology is applied for the preparation of solid-phase microextraction (SPME) fiber. The fiber demonstrates high thermal stability, efficient extraction rate and the selectivity for non-polar or low-polar analytes. Efficient SPME-GC-FID analyses of benzene- toluene-ethylbenzene-xylenes (BTEXs) and low-polar halocarbon were achieved by the sol-gel coated DSDA-DDBT-TiO2 fiber. Some parameters of the SPME fiber for the determination of halocarbon in aqueous sample were investigated. 展开更多
关键词 solid-phase microextraction sol-gel technology SELECTIVITY polyimide (DSDA-DDBT).
下载PDF
Determination of urinary 8-hydroxy-2′-deoxyguanosine by capillary electrophoresis with molecularly imprinted monolith in-tube solid phase microextraction 被引量:6
3
作者 Zhang, Shao Wen Zou, Cun Jie +4 位作者 Luo, Nan Weng, Qian Feng Cai, Ling Shuang Wu, Cai Ying Xing, Jun 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第1期85-88,共4页
Urinary 8-hydroxy-2 -deoxyguanosine(8-OHdG) is an excellent marker of oxidative DNA damage.In this study,employing guanosine as dummy template a novel molecularly imprinted(MIP) monolithic capillary column had been sy... Urinary 8-hydroxy-2 -deoxyguanosine(8-OHdG) is an excellent marker of oxidative DNA damage.In this study,employing guanosine as dummy template a novel molecularly imprinted(MIP) monolithic capillary column had been synthesized,and that was used as medium of in-tube solid phase microextraction(SPME).Coupled with capillary electrophoresis-electrochemical detection(CE-ECD),the system of extraction and detection of 8-OHdG in urinary sample had been developed.Because of its greater phase ratio combined with conv... 展开更多
关键词 Molecularly imprinted monolith In-tube solid phase microextraction 8-Hydroxy-2 -deoxyguanosine(8-OHdG) ELECTROPHORESIS Urine
下载PDF
Analysis of α, β, γ-hexachlorocyclohexanes in water by novel activated carbon fiber-solid phase microextraction coupled with gas chromatography—mass spectrometry 被引量:4
4
作者 SUNTong-hua FANGNeng-hu +2 位作者 ZHUNan-wen WANGYa-lin JIAJin-ping 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2004年第6期945-949,共5页
A fast and simple method for determination of α, β, γ-hexachlorocyclohexanes (HCHs) in water using activated carbon fiber-solid phase microextraction(ACF-SPME) were studied. Results showed the performance of adsorp... A fast and simple method for determination of α, β, γ-hexachlorocyclohexanes (HCHs) in water using activated carbon fiber-solid phase microextraction(ACF-SPME) were studied. Results showed the performance of adsorption and desorption of three HCHs on ACF were excellent. A wide linear range from 10 to 100 μg/L and detection limits of the ng/L level were obtained using ACF-SPME with GC-MS in selected ion monitoring(SIM) acquisition mode. The proposed method was also successfully applied for determination of three HCHs in tap water. Compared to commercial fibers, ACF showed some advantages such as better resistance to solvents, higher thermal stability, longer lifetime and lower cost. The data demonstrated that GC-MS with ACF-SPME is well suitable for the analysis of HCHs in water. 展开更多
关键词 solid phase microextraction activated carbon fiber residue analysis α β γ-hexachlorocyclohexanes GC-MS
下载PDF
Determination of Aromatic Components of Rosa davurica Pall. by Headspace Solid Phase Microextraction Combined with GC-MS 被引量:5
5
作者 Yuan NIU Qiong XU +4 位作者 Jian ZHUANG Yude WANG Lilan DAI Dengfei LI Yalan ZHAO 《Medicinal Plant》 CAS 2018年第5期20-22,26,共4页
[Objectives] To determine the aromatic components of Rosa davurica Pall. [Methods] 42 kinds of aromatic components were identified from the flowers of R. davurica by headspace solid phase microextraction( HS-SPME) com... [Objectives] To determine the aromatic components of Rosa davurica Pall. [Methods] 42 kinds of aromatic components were identified from the flowers of R. davurica by headspace solid phase microextraction( HS-SPME) combined with gas chromatography-mass spectrometry( GC-MS). The main compounds were alcohols( 54. 88%) and aldehydes( 19. 55%). [Results] The top five components with the highest relative content were phenylethyl alcohol( 12. 69%),geraniol( 9. 85%),citronellol( 8. 80%),nerol( 7. 84%) and 2-n-pentylfuran( 7. 45%). [Conclusions] Headspace solid phase microextraction( HS-SPME) combined with gas chromatography-mass spectrometry( GC-MS) can provide basis for further development and utilization of R. davurica. 展开更多
关键词 Rosa davurica Pall. HEADSPACE solid phase microextraction (HS-spme) Gas chromatography-mass spectrometry (GC-MS) AROMATIC COMPONENTS
下载PDF
Solid phase microextraction chemical biopsy tool for monitoring of doxorubicin residue during in vivo lung chemo-perfusion 被引量:4
6
作者 Barbara Bojko Nikita Looby +11 位作者 Mariola Olkowicz Anna Roszkowska Bogumiła Kupcewicz Pedro Reck dos Santos Khaled Ramadan Shaf Keshavjee Thomas K.Waddell German Goomez-Rios Marcos Tascon Krzysztof Gorynski Marcelo Cypel Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2021年第1期37-47,共11页
Development of a novel in vivo lung perfusion(IVLP)procedure allows localized delivery of high-dose doxorubicin(DOX)for targeting residual micrometastatic disease in the lungs.However,DOX delivery via IVLP requires ca... Development of a novel in vivo lung perfusion(IVLP)procedure allows localized delivery of high-dose doxorubicin(DOX)for targeting residual micrometastatic disease in the lungs.However,DOX delivery via IVLP requires careful monitoring of drug level to ensure tissue concentrations of this agent remain in the therapeutic window.A small dimension nitinol wire coated with a sorbent of biocompatible morphology(Bio-SPME)has been clinically evaluated for in vivo lung tissue extraction and determination of DOX and its key metabolites.The in vivo Bio-SPME-IVLP experiments were performed on pig model over various(150 and 225 mg/m^(2))drug doses,and during human clinical trial.Two patients with metastatic osteosarcoma were treated with a single 5 and 7 μg/mL(respectively)dose of DOX during a 3-h IVLP.In both pig and human cases,DOX tissue levels presented similar trends during IVLP.Human lung tissue concentrations of drug ranged between 15 and 293 μg/g over the course of the IVLP procedure.In addition to DOX levels,Bio-SPME followed by liquid chromatography-mass spectrometry analysis generated 64 metabolic features during endogenous metabolite screening,providing information about lung status during drug administration.Real-time monitoring of DOX levels in the lungs can be performed effectively throughout the IVLP procedure by in vivo Bio-SPME chemical biopsy approach.Bio-SPME also extracted various endogenous molecules,thus providing a real-time snapshot of the physiology of the cells,which might assist in the tailoring of personalized treatment strategy. 展开更多
关键词 In vivo solid phase microextraction Metabolite profiling Spatial resolution Therapeutic drug monitoring Tissue analysis
下载PDF
Comparison of Headspace Solid-Phase Microextraction with Simultaneous Steam Distillation Extraction for the Analysis of the Volatile Constituents in Chinese Apricot 被引量:20
7
作者 CHEN Mei-xia CHEN Xue-sen +4 位作者 WANG Xin-guo CI Zhi-juan LIU Xiao-li HE Tian-ming ZHANG Li-jie 《Agricultural Sciences in China》 CAS CSCD 2006年第11期879-884,共6页
Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction ... Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction (SSDE) and then analyzed using capillary gas chromatography and gas chromatography-mass spectrometry. A total of 70 components were identified by HSSPME, including 20 esters, 19 hydrocarbons, 5 alcohols, 5 ketones, 4 acids, 4 lactones, 3 aldehydes, and 10 miscellaneous components, with the esters being the dominant constituent. On the basis of the odor unit values, it is believed that the following compounds probably contributed to the fresh apricot odor: hexyl acetate, β-ionone, butyl acetate, (E)-2-hexenal, linalool, limonene, γ-decalactone, and hexanal. A total of 49 components were also detected by SSDE, including 13 hydrocarbons, 9 alcohols, 7 aldehydes, 9 esters, 4 ketones, 4 lactones, 2 acids, and 1 miscellaneous component, of which the monoterpene alcohols were the dominant constituents. It could be judged from the odor unit values that the following compounds were the major contributors to boiled apricot aroma: β-ionone, linalool, hexyl acetate, γ-dodecalactone, γ- decalactone, (E)-2-hexenal, hexanal, γ-octalactone, phenylacetaldehyde, butyl acetate, limonene, α-terpineol, and δ-decalactone. The results show that HS-SPME is a simple, rapid, and solvent-free method, which is an alternative to the classical SSDE. 展开更多
关键词 AROMA volatile constituents APRICOT solid-phase microextraction simultaneous distillation-extraction
下载PDF
A novel fiber coating for solid phase microextraction and its application for the extraction of n-alkane from aqueous sample 被引量:1
8
作者 HUANG Min-jia JIANG Gui-bin ZHAO Zong-shan 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2005年第6期930-932,共3页
Base on the previous work in laboratory, a novel polyaniline doped with polydimethylsiloxane coating was developed on a stainless steel wire for solid phase microextraction(SPME) by electroplating method. This elect... Base on the previous work in laboratory, a novel polyaniline doped with polydimethylsiloxane coating was developed on a stainless steel wire for solid phase microextraction(SPME) by electroplating method. This electroplating method not only has advantages of ease preparation and simple equipments required, but also increases the lifetime of the SPME fiber. The composite fiber(polyaniline/ polydimethylsiloxane(PANI/PDMS)) was evaluated by analyzing n-tridecane, n-tetradecane and n-pentadecane in aqueous sample. The new fiber coating showed comprehensive abilities to extract alkanes compounds. The relative standard deviations were found to be 6.8%-10.33%. 展开更多
关键词 solid phase microextraction stainless steel wires electroplating fiber preparation polyaniline/polydimethylsiloxane ALKANES
下载PDF
Preparation of polypyrrole/nanosilica composite for solid-phase microextraction of bisphenol and phthalates migrated from containers to eye drops and injection solutions 被引量:2
9
作者 Mehdi Ansari Dogaheh Mansoureh Behzadi 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2019年第3期185-192,共8页
This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized inf... This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized influencing parameters on the extraction efficiency and morphology of the nanocomposite such as deposition potential, concentration of pyrrole and polyphosphate, deposition time and the nanosilica amount. Under the optimized conditions, characterization of the nanocomposite was inves-tigated by scanning electron microscopy and Fourier transform infra-red spectroscopy. Also, the factors related to the solid-phase microextraction method including desorption temperature and time, extrac-tion temperature and time, ionic strength and pH were studied in detail. Subsequently, the proposed method was validated by gas chromatography-mass spectrometry by thermal desorption and acceptable figures of merit were obtained. The linearity of the calibration curves was between 0.01 and 50 ng/mL with acceptable correlation coefficients (0.9956-0.9987) and limits of detection were in the range 0.002-0.01 ng/mL. Relative standard deviations in terms of intra-day and inter-day by five replicate analyses from aqueous solutions containing 0.1 ng/mL of target analytes were in the range 3.3%-5.4% and 5%-7.1%, respectively. Fiber-to-fiber reproducibilities were measured for three different fibers prepared in the same conditions and the results were between 7.3% and 9.8%. Also, extraction recoveries at two different concentrations were ≥96%. Finally, the suitability of the proposed method was demonstrated through its application to the analysis of some eye drops and injection solutions. 展开更多
关键词 solid-phase microextraction Gas chromatography-mass spectrometry Polyphosphate-doped POLYPYRROLE NANOSILICA PHTHALATES BisphenolA
下载PDF
Integration of GC-MS Based Non-Targeted Metabolic Profiling with Headspace Solid Phase Microextraction Enhances the Understanding of Volatile Differentiation in Tobacco Leaves from North Carolina, India and Brazil 被引量:3
10
作者 Dong-Ming Ma Saiprasad V. S. Gandra +1 位作者 Navin Sharma De-Yu Xie 《American Journal of Plant Sciences》 2012年第12期1759-1769,共11页
In this report, gas chromatography-mass spectrometry (GC-MS) based non-targeted metabolomics is used to develop appropriate headspace solid phase microextractions (HS-SPME) to enhance the understanding of volatile com... In this report, gas chromatography-mass spectrometry (GC-MS) based non-targeted metabolomics is used to develop appropriate headspace solid phase microextractions (HS-SPME) to enhance the understanding of volatile complexity of flue-cured tobacco leaves. Non-targeted metabolic profiling of GC-MS shows that the extraction condition of HS-SPME at 100?C for 30 min provides a better metabolite profile than other extraction conditions tested. GC-MS and principal component analyses (PCA) show that among five types of fibers tested, 100 μm polydimethylsiloxane (PMDS), 65 μm polydimethylsiloxane/divinylbenzene (PMDS/DVB) and 75 μm carboxen/polydimethylsiloxane (CAR/ PMS) provide a better reproducible metabolite profile. Based on an appropriate PDMS extraction condition optimized, we use GC-MS analysis and PCA to compare metabolite profiles in flue-cured leaves of tobacco plants grown in North Carolina, India and Brazil, respectively. The resulting data of PCA show that the global metabolic profiles in North Carolina samples are separated from those in Brazil and India samples, two groups of which are characterized by a partially overlapped pattern. Several peaks that were differentially accumulated in samples were annotated to known metabolites by deconvolution analysis, such as norsolanadione, solavetivone and rishtin. Norsolanadione is detected only in Brazil samples. Solavetivone is detected in samples of India and Brazil but not in those of North Carolina. Rishtin is detected in samples of North Carolina and India but not in Brazil samples. These data indicate that not only can a non-targeted metabolic profiling approach enhance the understanding of volatile complexity, but also can identify marker volatile metabolites in tobacco leaves produced in different growth regions. 展开更多
关键词 TOBACCO HEADSPACE solid-phase microextraction Gas Chromatography Mass Spectrum VOLATILE Compounds
下载PDF
Flash Evaporation and Headspace Solid-phase Microextraction for the Analysis of the Essential Oils in Traditional Chinese Medicine,Houttuynia Cordata Thunb 被引量:1
11
作者 MinMinLIANG MeiLingQI RuoNongFU 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第5期659-662,共4页
关键词 Headspace solid-phase microextraction flash evaporation essential oils GC-MS.
下载PDF
Application of Phenyl Bonded Mesoporous Silica as A Novel Coating Layer of Solid-phase Microextraction for Determination of Benzo[a]pyrene in Water Samples
12
作者 XinZhenDU YaRongWANG QianMA XueFengMAO JinGuoHOU 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第6期801-804,共4页
关键词 Mesoporous silica solid-phase microextraction HPLC benzo[a]pyrene.
下载PDF
Sol-Gel-Coated Calix[4]arene Fiber for Solid-Phase Microextraction
13
作者 LiXiu-juan XiaoRui-min +1 位作者 LiHai-bing ZengZhao-rui 《Wuhan University Journal of Natural Sciences》 CAS 2003年第04A期1153-1155,共3页
5, 11, 17, 23-tetra-tert-butyl-25, 27-diethoxy-26, 28-dihydroxycalix \ arene /hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction with sol-gel technology. The pr... 5, 11, 17, 23-tetra-tert-butyl-25, 27-diethoxy-26, 28-dihydroxycalix \ arene /hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction with sol-gel technology. The properties of the new coating were investigated by analysis of benzene derivatives, polycyclic aromatic hydrocarbons and aromatic amines. The fiber is characterized by good sensitivity and selectivity to these aromatics. The fiber has stable performance at a high temperature of 380℃ and after a long solvent immersing, thus its lifetime is very long. It shows good fiber-to-fiber and batch-to-batch reproducibility. Furthermore, broad linear ranges and low detection limits are also its characteristics. 展开更多
关键词 solid-phase microextraction SOL-GEL CALIXARENE aromatic compounds
下载PDF
Solid-phase Microextraction with Benzoxy-calix[6]arene Fiber Coupled to Gas Chromatography for the Analysis of Polycyclic Aromatic Hydrocarbons in Water
14
作者 YE Chang-wen ZHANG Xue-na HUANG Jiang-yan LI Xiu-juan PAN Si-yi 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第2期198-202,共5页
Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seve... Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seven polycyclic aromatic hydrocarbons(PAHs) in water. The novel SPME fiber exhibited higher extraction efficiency to PAHs compared with poly(dimethylsiloxane) and other calixarene-containing fibers. Extraction/retention mechanism based on the interactions between calixarenes and PAHs was discussed. Owing to the good selectivity and high extraction capability of this calixarene fiber, low detection limits were obtained in a range of 0.34―6.50 ng/L and the relative standard deviation values were ≤12.3% for all of the analytes. The linear ranges of the proposed method were five orders of magnitude for the tested compounds, with linear correlation coefficients(r) greater than 0.998. The method was applied to the determination of polycyclic aromatic hydrocarbons in nine water sources in Wuhan City, China. Standard addition method was selected for the quantification and the recovery values were in a satisfactory range. Total PAHs concentrations in the nine surface water samples were found to vary between undetectable and 8.840 μg/L with two- and three-ring PAHs predominating. 展开更多
关键词 Polycyclic aromatic hydrocarbon solid-phase microextraction CALIXARENE Gas chromatography WATER
下载PDF
Determination of Trihalomethanes in Water Samples Using Headspace Solid-Phase Microextraction Gas Chromatography
15
作者 Nitaya Saesim Wanna Kanchanamayoon 《Journal of Chemistry and Chemical Engineering》 2010年第6期1-7,共7页
关键词 顶空固相微萃取 水样测定 三卤甲烷 气相色谱法 氯化过程 搅拌速度 提取时间 解吸时间
下载PDF
Solid-phase microextraction for flavor analysis in Harari Khat (Catha edulis) stimulant
16
作者 AL-FLAHIAbdulsalam 邹建凯 殷学锋 《Journal of Zhejiang University Science》 EI CSCD 2004年第4期428-431,共4页
This research examined the typical flavor compounds in the commonest type of Khat called Harari Khat grown in the region of Ethiopia.Twenty-eight compounds, which includes 1,2-Propanedione,1-Phenyl,Hexanol,Hexanal com... This research examined the typical flavor compounds in the commonest type of Khat called Harari Khat grown in the region of Ethiopia.Twenty-eight compounds, which includes 1,2-Propanedione,1-Phenyl,Hexanol,Hexanal compounds,Limonene, Benzaldehyde with other flavors, were extracted by polydimethylsiloxane at room temperature for 30min from Khat samples,and identified by solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS).This method needs no organic solvents and required minimal sample. 展开更多
关键词 固相微萃取 阿拉伯茶 哈拉尔族人 口味分析
下载PDF
基于HS-GC-IMS和HS-SPME-GC-MS的蛋白酶对豆粕挥发性风味的影响分析
17
作者 齐宝坤 刘雨雯 +3 位作者 姚玉雪 吴思雨 孙树坤 陈昊 《农业机械学报》 EI CAS CSCD 北大核心 2024年第4期352-367,410,共17页
为研究不同蛋白酶酶解对豆粕挥发性风味成分的影响,选用4种蛋白酶(碱性蛋白酶、中性蛋白酶、木瓜蛋白酶、风味蛋白酶)对豆粕进行酶解,采用顶空-气相色谱-离子迁移谱(Headspace-gas chromatography-ion mobility spectroscopy,HS-GC-IMS... 为研究不同蛋白酶酶解对豆粕挥发性风味成分的影响,选用4种蛋白酶(碱性蛋白酶、中性蛋白酶、木瓜蛋白酶、风味蛋白酶)对豆粕进行酶解,采用顶空-气相色谱-离子迁移谱(Headspace-gas chromatography-ion mobility spectroscopy,HS-GC-IMS)和顶空固相微萃取-气相色谱-质谱(Headspace solid phase microextraction-gas chromatography-mass spectrometry,HS-SPME-GC-MS)联用技术分析不同豆粕酶解物(Soybean meal hydrolysates,SMH)的挥发性风味成分,并结合主成分分析(Principal component analysis,PCA)、热图聚类和正交偏最小二乘判别法(Orthogonal partial least squares-discriminant analysis,OPLS-DA)对不同SMH进行分析。结果表明:碱性蛋白酶、中性蛋白酶、木瓜蛋白酶和风味蛋白酶酶解豆粕的挥发性风味成分存在较大差异。HS-GC-IMS鉴定出84种挥发性成分,筛选得到33种差异风味物质,发现酶解后酮类物质显著降低而醛类、醇类和酯类物质含量明显增加。PCA结果表明不同SMH之间的风味存在显著差异。最终通过OPLS-DA筛选出贡献较大的挥发性化合物,同时构建出可靠的用以鉴别SMH的模型。HS-SPME-GC-MS检测出103种差异风味物质,可用于区分不同SMH,被检出的挥发性组分中醛类、醇类和酮类等化合物为SMH风味的形成做出主要贡献,明晰了部分风味化合物形成的原因。PCA和聚类热图结果表明不同蛋白酶酶解对豆粕的挥发性风味物质的种类和含量有显著影响,其中,风味蛋白酶和木瓜蛋白酶对豆粕的风味改善最为显著。 展开更多
关键词 豆粕 酶解 顶空-气相色谱-离子迁移谱 顶空固相微萃取-气相色谱-质谱
下载PDF
基于HS-SPME-GC-MS与电子鼻分析芹菜贮藏期间挥发性物质的变化 被引量:1
18
作者 芦佳琪 吴玉珍 +3 位作者 张瑞 韩晶晶 熊爱生 郁志芳 《食品工业科技》 CAS 北大核心 2024年第5期212-222,共11页
采用顶空固相微萃取技术结合气相色谱-质谱联用(headspace solid phase microextraction-gas chromatography-mass spectrometry,HS-SPME-GC-MS)和电子鼻技术分析了20.0℃贮藏期间芹菜叶片挥发性物质的组成和含量的变化。结果显示,采用H... 采用顶空固相微萃取技术结合气相色谱-质谱联用(headspace solid phase microextraction-gas chromatography-mass spectrometry,HS-SPME-GC-MS)和电子鼻技术分析了20.0℃贮藏期间芹菜叶片挥发性物质的组成和含量的变化。结果显示,采用HS-SPME-GC-MS技术从芹菜中共检测到108种挥发性物质,单萜类(43.2%~52.92%)和苯酞类(19.93%~28.97%)为主要组分,其中D-柠檬烯含量丰富(6600.64~48566.12μg/kg)。新鲜芹菜总挥发性物质含量为165682.48μg/kg,贮藏9 d后含量下降了40.92%,单萜类和苯酞类物质分别下降了9.72%和上升了8.98%。OAV分析结果表明芹菜叶片中共有31种OAV>1的特征挥发性物质,0~7 d特征挥发性物质有31种且组成相同,第9 d特征挥发性物质减少至29种,贮藏期间总OAV值呈下降趋势。聚类分析结果表明,0~3 d芹菜叶片以薄荷香和青草香为主,第7 d具有甜香、木香和樟脑香,第9 d后以辛辣和药草气味为主。基于电子鼻检测结果的主成分分析可以清晰区分不同贮藏时间芹菜叶片的香气,基于Pearson相关性分析,引起电子鼻响应值变化的物质主要是芹菜中萜类、醇类、芳香型挥发性物质(r≥0.80,P<0.05)。本研究的结果阐明了贮藏期间芹菜叶片挥发性物质组成和含量的变化规律,为贮藏期间芹菜新鲜度的判断提供了理论基础。 展开更多
关键词 芹菜 贮藏 HS-spme-GC-MS 电子鼻 挥发性物质 OAV
下载PDF
HS-SPME-GC-MS鉴定不同采收程度霞晖水蜜桃的风味物质变化 被引量:1
19
作者 王塔娜 陈小龙 +5 位作者 张佳辉 王冬兰 王亚 宋立晓 马凤鸣 余向阳 《浙江农业科学》 2024年第2期427-435,共9页
风味物质常用来评价桃果实的品质,香气成分不仅能反映果实的风味特征和品质,还能体现果实的成熟度。利用顶空固相微萃取(HS-SPME)结合气相色谱-质谱联用仪(GC-MS)鉴定了霞晖水蜜桃果实可挥发性风味物质,并针对水蜜桃S形成熟曲线,成熟后... 风味物质常用来评价桃果实的品质,香气成分不仅能反映果实的风味特征和品质,还能体现果实的成熟度。利用顶空固相微萃取(HS-SPME)结合气相色谱-质谱联用仪(GC-MS)鉴定了霞晖水蜜桃果实可挥发性风味物质,并针对水蜜桃S形成熟曲线,成熟后期快速软化的特点,选择后期外观差异较小且按照售卖经验分类为可采摘与不可采摘两类水蜜桃进行差异分析,寻找其特征差异物质。本研究共分离得到45种风味物质,主要包括苯甲醛、壬醛、十一醛、芳樟醇、2-乙基己醇、正癸醇、1-十一醇、γ-癸内酯、γ-十二内酯、辛酸乙酯和壬酸等。不可采收的霞晖水蜜桃果实和可采收的霞晖水蜜桃果实中差异特征风味物质分别是苯甲醛(35.84%)降低和γ-癸内酯(17.81%)升高。总体来看,醛类和内酯类化合物对霞晖水蜜桃果实香气的贡献值得关注。上述研究以期为水蜜桃精准采摘、智慧化采摘提供科学依据。 展开更多
关键词 霞晖水蜜桃 采收程度 风味物质 顶空固相微萃取 气相色谱质谱分析
下载PDF
基于电子鼻、HS-SPME-GC-MS和HS-GC-IMS评价不同制油工艺对大豆油品质及风味的影响 被引量:2
20
作者 吴思雨 谢萱 +2 位作者 刘雨雯 孙树坤 陈昊 《食品科学》 EI CAS CSCD 北大核心 2024年第4期183-196,共14页
为探究不同制油工艺(冷榨法、浸出法、冷榨-浸出法)对三级大豆油品质及风味的影响,测定了大豆油的理化性质及脂肪酸组成,分别采用电子鼻、顶空-固相微萃取-气相色谱-质谱(headspace-solid phase microextraction-gaschromatography-mass... 为探究不同制油工艺(冷榨法、浸出法、冷榨-浸出法)对三级大豆油品质及风味的影响,测定了大豆油的理化性质及脂肪酸组成,分别采用电子鼻、顶空-固相微萃取-气相色谱-质谱(headspace-solid phase microextraction-gaschromatography-massspectrometry,HS-SPME-GC-MS)法和顶空-气相色谱-离子迁移谱(headspace-gas chromatography-ion mobility spectroscopy,HS-GC-IMS)法鉴定3种豆油中挥发性化合物,并借助聚类热图、主成分分析(principal component analysis,PCA)和正交偏最小二乘判别分析(orthogonal partial least squares-discriminant analysis,OPLS-DA)对3种豆油的挥发性化合物数据进行差异分析。结果表明,冷榨型豆油的水分含量最低,浸出型豆油过氧化值显著偏高且油脂色泽最深;浓香型豆油中亚油酸含量最多,营养价值更高;被检出的挥发性组分中,醇类、醛类以及吡嗪类化合物为豆油风味的形成做出主要贡献,明晰了部分风味化合物形成的原因。最终通过OPLS-DA筛选出45种贡献较大的挥发性化合物,同时构建可靠的用以鉴别浓香型豆油的模型。此外,发现豆油的品质与风味之间存在一定的相关性。 展开更多
关键词 大豆油 理化性质 挥发性化合物 顶空-固相微萃取-气相色谱-质谱法 顶空-气相色谱-离子迁移谱法 正交偏最小二乘判别分析
下载PDF
上一页 1 2 157 下一页 到第
使用帮助 返回顶部