Irregular phase-space orbits of the electrons are harmful to the electron-beam transport quality and hence deteriorate the performance of a free-electron laser (FEL). In previous literature, it was demonstrated that...Irregular phase-space orbits of the electrons are harmful to the electron-beam transport quality and hence deteriorate the performance of a free-electron laser (FEL). In previous literature, it was demonstrated that the irregularity of the electron phase-space orbits could be caused in several ways, such as varying the wiggler amplitude and inducing sidebands. Based on a Hamiltonian model with a set of self-consistent differential equations, it is shown in this paper that the electron- beam normalized plasma frequency functions not only couple the electron motion with the FEL wave, which results in the evolution of the FEL wave field and a possible power saturation at a large beam current, but also cause the irregularity of the electron phase-space orbits when the normalized plasma frequency has a sufficiently large value, even if the initial energy of the electron is equal to the synchronous energy or the FEL wave does not reach power saturation.展开更多
In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can re- lieve glaucomatous optic neuropathy. Increased intracranial pressure can also r...In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can re- lieve glaucomatous optic neuropathy. Increased intracranial pressure can also reduce optic nerve damage in glaucoma patients, and a safe, effective and noninvasive way to achieve this is by increasing the intra-abdominal pressure. The purpose of this study was to observe the changes in orbital subarachnoid space width and intraocular pressure at elevated intra-abdominal pressure. An inflatable abdominal belt was tied to each of 15 healthy volunteers, aged 22-30 years (12 females and 3 males), at the navel level, without applying pressure to the abdomen, before they laid in the magnetic resonance imaging machine. The baseline orbital subarachnoid space width around the optic nerve was measured by magnetic resonance imaging at 1, 3, 9, and 15 mm behind the globe. The abdominal belt was inflated to increase the pressure to 40 mmHg (1 mmHg = 0.133 kPa), then the orbital subarachnoid space width was measured every 10 minutes for 2 hours. After removal of the pressure, the measurement was repeated 10 and 20 minutes later. In a separate trial, the intraocular pressure was measured for all the subjects at the same time points, before, during and after elevated intra-abdominal pressure. Results showed that the baseline mean orbital subarachnoid space width was 0.88 + 0.1 mm (range: 0.77-1.05 mm), 0.77 + 0.11 mm (range: 0.60-0.94 mm), 0.70 + 0.08 mm (range: 0.62-0.80 ram), and 0.68 _+ 0.08 mm (range: 0.57-0.77 mm) at 1, 3, 9, and 15 mm behind the globe, respectively. During the elevated intra-abdominal pressure, the orbital subarachnoid space width increased from the baseline and dilation of the optic nerve sheath was significant at 1, 3 and 9 mm behind the globe. After decompression of the abdominal pressure, the orbital subarachnoid space width normalized and returned to the baseline value. There was no significant difference in the intraocular pressure before, during and after the intra-abdominal pressure elevation. These results verified that the increased intra-abdominal pressure widens the orbital subarachnoid space in this acute trial, but does not alter the intraocular pressure, indicating that intraocular pressure is not affected by rapid increased in- tra-abdominal pressure. This study was registered in the Chinese Clinical Trial Registry (registration number: ChiCTR-ONRC-14004947).展开更多
This paper gives a brief introduction of YingHuo-1(YH-1),a Chinese Martian Space Environment Exploration Orbiter.YH-1 is a micro-satellite developed by Chinese Aerospace Industry,and will be launched together with Rus...This paper gives a brief introduction of YingHuo-1(YH-1),a Chinese Martian Space Environment Exploration Orbiter.YH-1 is a micro-satellite developed by Chinese Aerospace Industry,and will be launched together with Russian spacecraft,Phobos-Grunt,to orbit Mars in September,2009.Four payloads are selected for the mission,plasma package,including of electron analyzer,ion energy and mass analyzer;sat-sat occultation receiver;flux-gate magnetometer;and optical monitor.YH-1 mission focus on the investigation of the characteristics and its evolution of the Martian space Environment,and identifying major plasma processes,which provide channels for Martian volatiles escaping.展开更多
AIM: To investigate the diffusion changes in both the optic nerve and optic tract in orbital space-occupying lesion patients with decreased visual acuity, and its clinical significance using probabilistic diffusion tr...AIM: To investigate the diffusion changes in both the optic nerve and optic tract in orbital space-occupying lesion patients with decreased visual acuity, and its clinical significance using probabilistic diffusion tractography(PDT). METHODS: Twenty patients with orbital space-occupying lesions and 25 age-and gender-matched healthy persons were included. All patients and controls underwent routine orbital magnetic resonance imaging and diffusion tensor imaging(DTI), using a 3.0 T magnetic resonance scanner(Trio Tim Siemens). After the image data were preprocessed, each DTI parameters of the optic nerve and optic tract was obtained by PDT, including fractional anisotropy(FA), mean diffusivity(MD), axial diffusivity(AD) and radial diffusivity(RD). The asymmetry index(AI) of each parameter was calculated. Compared the parameters of the affected side optic nerve and ipsilateral optic tract with the contralateral side by paired sample t-test;compared AI of parameters of optic nerve and optic tract between the patient group and the control group by independent sample t-test. Patients were divided into threesubgroups according to the low vision grade standard of WHO, compared the FA and AI of FA between the three subgroups by single factor variance analysis. RESULTS: The affected side optic nerve presented significantly decreased FA, increased MD, AD, and RD values compared to the unaffected side(P<0.05). The AI of FA, MD, AD, and RD of optic nerve in the patients was significantly higher than that of the controls(P<0.05). The comparison results of the optic tract showed that there was no significant difference between the patient group and control group in terms of the bilateral optic tracts in patients(P>0.05). The AIs of the FA value of the optic nerve in the eyesight <0.1 subgroup was significantly higher than that in the other groups(P<0.05). CONCLUSION: FA, MD, AD, and RD of the affected side optic nerve of the orbital space-occupying lesions have significantly changed, the FA value is the most sensitive. The PDT could be a useful tool to provide valid quantitative markers of optic nerve injuries and evaluate the severity of orbital diseases, which other examinations cannot be acquired.展开更多
Objective:To analyze the clinical features,histopathologic classification and frequencies of various types of recurrent orbital space-occupying lesions.Methods:A retrospective study was carried out in 253 consecutiv...Objective:To analyze the clinical features,histopathologic classification and frequencies of various types of recurrent orbital space-occupying lesions.Methods:A retrospective study was carried out in 253 consecutive patients with recurrent orbital spaceoccupying lesions treated by surgical excision in the Institute of Orbital Diseases,the General Hospital of the Armed Police Force from January 2009 to December 2010.Results:The patients included 123 males and 130 females aged 2 to 78 years(mean,36.2 years),and the last recurrence interval after operation ranged from 1 month to 40 years(median,4.75 years).Of all the cases,159(62.8%),65(25.7%),20(7.9%),8(3.2%) and 1(0.4%) had previously experienced once,twice,three,four and six times of surgeries,respectively.Among them,29(11.5%) cases had recurred 3 times or over,and 37(14.6%) cases got recurrence in 10 or more years postoperatively.Most of the patients with local recurrence presented with various clinical manifestations,while 31(12.3%) cases were symptom-free.Two hundred and thirty-one(91.3%) cases underwent surgical removal of the recurrent orbital lesions,and another 22(8.7%) cases had to receive the exenteration of orbit.Categories of these recurrent orbital lesions after operation were as follows:lacrimal gland tumors,65(25.7%) cases;vasogenic diseases,54(21.3%) cases;neurogenic tumors,42(16.6%) cases;secondary tumors,24(9.5%) cases;orbital inflammation,21(8.3%) cases;myogenic tumors,14(5.5%) cases;fibrous and adipose tumors,12(4.7%) cases;lympho-hematopoietic tumors,7(2.8%) cases;bone or cartilage tumors,7(2.8%) cases;orbital cysts,6(2.4%) cases;and indefinitely differentiated tumor,1(0.4%) case.The 10 top histopathologic diagnoses were lacrimal gland pleomorphic adenoma,hemangiolymphangioma,lacrimal gland adenoid cystic carcinoma,meningioma,inflammatory pseudotumor,neurofibroma,sebaceous gland carcinoma,vascular malformation,rhabdomyosarcoma and hemangioma.Conclusions:The variety of recurrent orbital lesions after operation includes mainly of tumors except for vascular malformation and orbital inflammatory lesions.The lacrimal gland epithelial tumor is most prone to relapse after resection,and early and longer-term postoperative follow-up is needed.展开更多
The light's orbital angular momentum (OAM) is a consequence of the spiral flow of the electromagnetic energy. In this paper, an analysis of light beams with OAM used for free space optics (FSO) is conducted. The ...The light's orbital angular momentum (OAM) is a consequence of the spiral flow of the electromagnetic energy. In this paper, an analysis of light beams with OAM used for free space optics (FSO) is conducted. The basic description and conception of light's OAM are reviewed. Both encoding information into OAM states of single light beam and encoding information into spatial structure of the mixed optical vortex with OAM are discussed, and feasibility to improve the FSO's performance of security and obstruction of line of sight is examined.展开更多
针对小行星探测器高精度自主视觉定位问题,提出了一种融合轨道动力学的深空探测器自主视觉定位方法,能修正视觉视觉定位与地图构建算法(simultaneous localization and mapping,SLAM)的定位误差。该方法通过融合轨道动力学的轨道改进技...针对小行星探测器高精度自主视觉定位问题,提出了一种融合轨道动力学的深空探测器自主视觉定位方法,能修正视觉视觉定位与地图构建算法(simultaneous localization and mapping,SLAM)的定位误差。该方法通过融合轨道动力学的轨道改进技术,能够在缺乏表面先验信息、无人工手动标记的场景下,实现探测器的高精度视觉导航,并建立小行星表面稠密三维模型。首先,基于视觉同时定位和建图方法(VSLAM)提取小行星表面特征,通过因子图优化算法估计探测器位姿,设计回环检测提高定位精度;其次,重构行星表面三维模型,实现基于多面体法的行星不规则引力场建模;最后,提出了一种基于轨道动力学的伪相对运动轨道优化算法,将其作为物理约束修正视觉定位累积误差,分析反演视觉初始定轨误差在轨道动力学中的传播过程,实现修正视觉定位累积误差,改善初始定位结果。仿真实验结果表明,融合轨道动力学可以有效提升小行星探测视觉定位的精度,从而实现高精度导航,为深空探测技术的未来发展提供参考借鉴。展开更多
针对在地面站天线对空间站观测任务中,通常基于卫星工具包(satellite tool kit,STK)软件规划出天线对空间站的方位角和俯仰角,实现天线对空间站的自动跟踪.为了保证天线跟踪的准确性和可靠性,需要定期计算出准确的空间站轨道和天线的方...针对在地面站天线对空间站观测任务中,通常基于卫星工具包(satellite tool kit,STK)软件规划出天线对空间站的方位角和俯仰角,实现天线对空间站的自动跟踪.为了保证天线跟踪的准确性和可靠性,需要定期计算出准确的空间站轨道和天线的方位俯仰角,并更新规划任务.因此科学分析与评估空间站两行轨道根数(two line elements,TLE)长期预报精度,对地面站实现空间站的精准跟踪具有重要意义.本文以中国空间站(China Space Station,CSS)梦天实验舱为例,基于TLE数据,利用STK软件提供的简化常规摄动规模型(simplified general perturbations4,SGP4)模型计算空间站轨道以及空间站相对于西安地面站的方位角和俯仰角,并分析不同策略下的精度效果.试验结果表明:在第二天更新空间站的TLE,可以获得较好的轨道结果,从而更好地保障天线的跟踪精度.展开更多
基金Project supported by the Science Foundation of Department of Education of Sichuan Province,China (Grant No.12233454)the Youth Foundation of Department of Education of Sichuan Province,China (Grant No.10ZB080)the Xihua University Foundation,China (Grant No.Z0913306)
文摘Irregular phase-space orbits of the electrons are harmful to the electron-beam transport quality and hence deteriorate the performance of a free-electron laser (FEL). In previous literature, it was demonstrated that the irregularity of the electron phase-space orbits could be caused in several ways, such as varying the wiggler amplitude and inducing sidebands. Based on a Hamiltonian model with a set of self-consistent differential equations, it is shown in this paper that the electron- beam normalized plasma frequency functions not only couple the electron motion with the FEL wave, which results in the evolution of the FEL wave field and a possible power saturation at a large beam current, but also cause the irregularity of the electron phase-space orbits when the normalized plasma frequency has a sufficiently large value, even if the initial energy of the electron is equal to the synchronous energy or the FEL wave does not reach power saturation.
文摘In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can re- lieve glaucomatous optic neuropathy. Increased intracranial pressure can also reduce optic nerve damage in glaucoma patients, and a safe, effective and noninvasive way to achieve this is by increasing the intra-abdominal pressure. The purpose of this study was to observe the changes in orbital subarachnoid space width and intraocular pressure at elevated intra-abdominal pressure. An inflatable abdominal belt was tied to each of 15 healthy volunteers, aged 22-30 years (12 females and 3 males), at the navel level, without applying pressure to the abdomen, before they laid in the magnetic resonance imaging machine. The baseline orbital subarachnoid space width around the optic nerve was measured by magnetic resonance imaging at 1, 3, 9, and 15 mm behind the globe. The abdominal belt was inflated to increase the pressure to 40 mmHg (1 mmHg = 0.133 kPa), then the orbital subarachnoid space width was measured every 10 minutes for 2 hours. After removal of the pressure, the measurement was repeated 10 and 20 minutes later. In a separate trial, the intraocular pressure was measured for all the subjects at the same time points, before, during and after elevated intra-abdominal pressure. Results showed that the baseline mean orbital subarachnoid space width was 0.88 + 0.1 mm (range: 0.77-1.05 mm), 0.77 + 0.11 mm (range: 0.60-0.94 mm), 0.70 + 0.08 mm (range: 0.62-0.80 ram), and 0.68 _+ 0.08 mm (range: 0.57-0.77 mm) at 1, 3, 9, and 15 mm behind the globe, respectively. During the elevated intra-abdominal pressure, the orbital subarachnoid space width increased from the baseline and dilation of the optic nerve sheath was significant at 1, 3 and 9 mm behind the globe. After decompression of the abdominal pressure, the orbital subarachnoid space width normalized and returned to the baseline value. There was no significant difference in the intraocular pressure before, during and after the intra-abdominal pressure elevation. These results verified that the increased intra-abdominal pressure widens the orbital subarachnoid space in this acute trial, but does not alter the intraocular pressure, indicating that intraocular pressure is not affected by rapid increased in- tra-abdominal pressure. This study was registered in the Chinese Clinical Trial Registry (registration number: ChiCTR-ONRC-14004947).
文摘This paper gives a brief introduction of YingHuo-1(YH-1),a Chinese Martian Space Environment Exploration Orbiter.YH-1 is a micro-satellite developed by Chinese Aerospace Industry,and will be launched together with Russian spacecraft,Phobos-Grunt,to orbit Mars in September,2009.Four payloads are selected for the mission,plasma package,including of electron analyzer,ion energy and mass analyzer;sat-sat occultation receiver;flux-gate magnetometer;and optical monitor.YH-1 mission focus on the investigation of the characteristics and its evolution of the Martian space Environment,and identifying major plasma processes,which provide channels for Martian volatiles escaping.
基金Supported by the National Natural Science Foundation of China (No.81471649)Beijing Municipal Science and Technology Commission (No. Z171100000117001)
文摘AIM: To investigate the diffusion changes in both the optic nerve and optic tract in orbital space-occupying lesion patients with decreased visual acuity, and its clinical significance using probabilistic diffusion tractography(PDT). METHODS: Twenty patients with orbital space-occupying lesions and 25 age-and gender-matched healthy persons were included. All patients and controls underwent routine orbital magnetic resonance imaging and diffusion tensor imaging(DTI), using a 3.0 T magnetic resonance scanner(Trio Tim Siemens). After the image data were preprocessed, each DTI parameters of the optic nerve and optic tract was obtained by PDT, including fractional anisotropy(FA), mean diffusivity(MD), axial diffusivity(AD) and radial diffusivity(RD). The asymmetry index(AI) of each parameter was calculated. Compared the parameters of the affected side optic nerve and ipsilateral optic tract with the contralateral side by paired sample t-test;compared AI of parameters of optic nerve and optic tract between the patient group and the control group by independent sample t-test. Patients were divided into threesubgroups according to the low vision grade standard of WHO, compared the FA and AI of FA between the three subgroups by single factor variance analysis. RESULTS: The affected side optic nerve presented significantly decreased FA, increased MD, AD, and RD values compared to the unaffected side(P<0.05). The AI of FA, MD, AD, and RD of optic nerve in the patients was significantly higher than that of the controls(P<0.05). The comparison results of the optic tract showed that there was no significant difference between the patient group and control group in terms of the bilateral optic tracts in patients(P>0.05). The AIs of the FA value of the optic nerve in the eyesight <0.1 subgroup was significantly higher than that in the other groups(P<0.05). CONCLUSION: FA, MD, AD, and RD of the affected side optic nerve of the orbital space-occupying lesions have significantly changed, the FA value is the most sensitive. The PDT could be a useful tool to provide valid quantitative markers of optic nerve injuries and evaluate the severity of orbital diseases, which other examinations cannot be acquired.
文摘Objective:To analyze the clinical features,histopathologic classification and frequencies of various types of recurrent orbital space-occupying lesions.Methods:A retrospective study was carried out in 253 consecutive patients with recurrent orbital spaceoccupying lesions treated by surgical excision in the Institute of Orbital Diseases,the General Hospital of the Armed Police Force from January 2009 to December 2010.Results:The patients included 123 males and 130 females aged 2 to 78 years(mean,36.2 years),and the last recurrence interval after operation ranged from 1 month to 40 years(median,4.75 years).Of all the cases,159(62.8%),65(25.7%),20(7.9%),8(3.2%) and 1(0.4%) had previously experienced once,twice,three,four and six times of surgeries,respectively.Among them,29(11.5%) cases had recurred 3 times or over,and 37(14.6%) cases got recurrence in 10 or more years postoperatively.Most of the patients with local recurrence presented with various clinical manifestations,while 31(12.3%) cases were symptom-free.Two hundred and thirty-one(91.3%) cases underwent surgical removal of the recurrent orbital lesions,and another 22(8.7%) cases had to receive the exenteration of orbit.Categories of these recurrent orbital lesions after operation were as follows:lacrimal gland tumors,65(25.7%) cases;vasogenic diseases,54(21.3%) cases;neurogenic tumors,42(16.6%) cases;secondary tumors,24(9.5%) cases;orbital inflammation,21(8.3%) cases;myogenic tumors,14(5.5%) cases;fibrous and adipose tumors,12(4.7%) cases;lympho-hematopoietic tumors,7(2.8%) cases;bone or cartilage tumors,7(2.8%) cases;orbital cysts,6(2.4%) cases;and indefinitely differentiated tumor,1(0.4%) case.The 10 top histopathologic diagnoses were lacrimal gland pleomorphic adenoma,hemangiolymphangioma,lacrimal gland adenoid cystic carcinoma,meningioma,inflammatory pseudotumor,neurofibroma,sebaceous gland carcinoma,vascular malformation,rhabdomyosarcoma and hemangioma.Conclusions:The variety of recurrent orbital lesions after operation includes mainly of tumors except for vascular malformation and orbital inflammatory lesions.The lacrimal gland epithelial tumor is most prone to relapse after resection,and early and longer-term postoperative follow-up is needed.
文摘The light's orbital angular momentum (OAM) is a consequence of the spiral flow of the electromagnetic energy. In this paper, an analysis of light beams with OAM used for free space optics (FSO) is conducted. The basic description and conception of light's OAM are reviewed. Both encoding information into OAM states of single light beam and encoding information into spatial structure of the mixed optical vortex with OAM are discussed, and feasibility to improve the FSO's performance of security and obstruction of line of sight is examined.
文摘针对小行星探测器高精度自主视觉定位问题,提出了一种融合轨道动力学的深空探测器自主视觉定位方法,能修正视觉视觉定位与地图构建算法(simultaneous localization and mapping,SLAM)的定位误差。该方法通过融合轨道动力学的轨道改进技术,能够在缺乏表面先验信息、无人工手动标记的场景下,实现探测器的高精度视觉导航,并建立小行星表面稠密三维模型。首先,基于视觉同时定位和建图方法(VSLAM)提取小行星表面特征,通过因子图优化算法估计探测器位姿,设计回环检测提高定位精度;其次,重构行星表面三维模型,实现基于多面体法的行星不规则引力场建模;最后,提出了一种基于轨道动力学的伪相对运动轨道优化算法,将其作为物理约束修正视觉定位累积误差,分析反演视觉初始定轨误差在轨道动力学中的传播过程,实现修正视觉定位累积误差,改善初始定位结果。仿真实验结果表明,融合轨道动力学可以有效提升小行星探测视觉定位的精度,从而实现高精度导航,为深空探测技术的未来发展提供参考借鉴。
文摘针对在地面站天线对空间站观测任务中,通常基于卫星工具包(satellite tool kit,STK)软件规划出天线对空间站的方位角和俯仰角,实现天线对空间站的自动跟踪.为了保证天线跟踪的准确性和可靠性,需要定期计算出准确的空间站轨道和天线的方位俯仰角,并更新规划任务.因此科学分析与评估空间站两行轨道根数(two line elements,TLE)长期预报精度,对地面站实现空间站的精准跟踪具有重要意义.本文以中国空间站(China Space Station,CSS)梦天实验舱为例,基于TLE数据,利用STK软件提供的简化常规摄动规模型(simplified general perturbations4,SGP4)模型计算空间站轨道以及空间站相对于西安地面站的方位角和俯仰角,并分析不同策略下的精度效果.试验结果表明:在第二天更新空间站的TLE,可以获得较好的轨道结果,从而更好地保障天线的跟踪精度.