Based on an engineering background of a deep tunneling in weak rocks, the numerical modeling is used to compare different support schemes of tunnel at great depth in this paper. Focused on the general behaviors of wea...Based on an engineering background of a deep tunneling in weak rocks, the numerical modeling is used to compare different support schemes of tunnel at great depth in this paper. Focused on the general behaviors of weak rocks at great depth, a tunneling scheme with rock bolting and steel fibre reinforced sprayed concrete is proposed. This scheme is practiced successfully at a deep tunnel in weak rocks in Coal Mine No 10 of Hebi Coal Mining Administration.展开更多
The blast resistance of structures used in buildings needs to be investigated due to the increased threat of a terrorist attack. The damage done by Composition B or Powergel to steel fibre reinforced reactive powder c...The blast resistance of structures used in buildings needs to be investigated due to the increased threat of a terrorist attack. The damage done by Composition B or Powergel to steel fibre reinforced reactive powder concrete (SFRPC) panels and ordinary reinforced concrete (RC) panels of equivalent static flexural strength is compared. A 0.5 kg charge was detonated at a distance of 0.1 m from the 1.3 m×1.0 m×0. 1 m (thick) panels, which were simply supported and spaning 1.3m. Dynamic displacement measurements, high-speed video recording and visual examination of the panels for spall and breach were undertaken. The SFRPC panels withstood the bare charge blast better than the reinforced ordinary concrete panels. Neither type of panel was breached using a 0.5 kg charge. The RC panel exhibited more spalling when Composition B was used. Under successive Composition B loading conditions, the RC panel was breached. In comparison the SFRPC panel was not breached. Exposure to fragmenting charge loading conditions confirmed these performance differences between the SFRPC panel and the reinforced ordinary concrete panel.展开更多
The effect of steel fibre used in concrete was systematically analyzed by model testing of 30 2-pile thick caps of steel-fibre reinforced concrete, in which the model scale was 1:5. The experiment system composed of ...The effect of steel fibre used in concrete was systematically analyzed by model testing of 30 2-pile thick caps of steel-fibre reinforced concrete, in which the model scale was 1:5. The experiment system composed of a loading device, strain measurement system and a data-acquisition system was used, also an electromechanic centigrade scale, a lens and a Y J-25 static resistance strainometer were used.The experimental results show that the volumetric rate of steel fibre and draw ratio have an important influence on its load-bearing capacity. The incorporation of steel fibre can effectively improve the extension and reduce the thickness of the caps.展开更多
This paper reports investigation conducted to study the fatigue performance of steel fibre reinforced concrete (SFRC) containing fibres of mixed aspect ratio. An extensive experimental program was conducted in which 9...This paper reports investigation conducted to study the fatigue performance of steel fibre reinforced concrete (SFRC) containing fibres of mixed aspect ratio. An extensive experimental program was conducted in which 90 flexural fatigue tests were carried out at different stress levels on size 500 mm×100 mm×100 mm SFRC specimens respectively containing 1.0%, 1.5% and 2.0% volume fraction of fibres. About 36 static flexural tests were also conducted to determine the static flexural strength prior to fatigue testing. Each volume fraction of fibres incorporated corrugated mixed steel fibres of size 0.6 mm×2.0 mm×25 mm and 0.6 mm×2.0 mm×50 mm in ratio 50:50 by weight. The results are presented both as S-N relationships, with the maximum fatigue stress expressed as a percentage of the strength under static loading, and as relationships between actually applied fatigue stress and number of loading cycles to failure. Two-million-cycle fatigue strengths of SFRC containing different volume fractions of mixed fibres were obtained and compared with plain concrete.展开更多
The influences of adding steel fibres of different lengths up to 3 volume percentages, on the rheological behaviour of an alumina-magnesia-extruded graphite pellet containing castables have been studied using a rheome...The influences of adding steel fibres of different lengths up to 3 volume percentages, on the rheological behaviour of an alumina-magnesia-extruded graphite pellet containing castables have been studied using a rheometer. Free-flow measurements have shown that the flow is severely affected by increasing the length of steel fibres. The calculated values of rheological constants indicate that 19 mm and 25 mm fibre up to 2 volume percentage is permitted while one volume percentage of 50 mm fibres severely degrades the rheology of the castable.展开更多
The fibre pullout test was conducted to investigate the influence of the water stability on the bond behaviour between the Magnesium phosphate cement(MPC)matrix and the steel fibre.The composition of the MPC-matrix an...The fibre pullout test was conducted to investigate the influence of the water stability on the bond behaviour between the Magnesium phosphate cement(MPC)matrix and the steel fibre.The composition of the MPC-matrix and the immersion age of the specimens are experimentally investigated.The average bond strength and the pullout energy are investigated by analysing the experimental results.In addition,the microscopic characteristics of the interface transition zone are investigated using scanning electron microscopy(SEM).The experimental results showed that the bond performance between the MPC-matrix and the steel fibre decreased significantly with the increase of the duration of immersion in water.The average bond strength between the steel fibre and the MPC-matrix reduced by more than 50%when the specimens were immersed in the water for 28 days.The effect of the water on the interface between the steel fibre and the MPC-matrix was found to be more significant compared to the composition of the MPC-matrix.In addition,the MgO-KH2PO4 mole ratio of the MPC significantly influenced the water stability of the interface zone between the steel fibre and MPC-matrix.展开更多
The mixing of non-woven steel fibres in melt overflow process for use in automotive muffler systems was simulated. The aim was to identify optimum parameters for achieving a good fibre mix. Numerical models of mixing ...The mixing of non-woven steel fibres in melt overflow process for use in automotive muffler systems was simulated. The aim was to identify optimum parameters for achieving a good fibre mix. Numerical models of mixing chambers of melt overflow process were developed. Multiphysics analyses involving heat transfer, fluid flow and particle tracking were carried out using COMSOL code. The influence of air jet configurations on the fibre distribution was studied. The fibres settled on the moving bed within the mixing chamber were examined for their uniformity. The effect of additional air jets to the existing chamber in a range of regions was explored. An optimum configuration was identified by analyzing the compactness of the particle clusters deposited in the simulation and validated using pixel data acquired from real time imaging. The results showed that by employing dual air jets at the front end of the chamber, the density of the fibre material has improved. We conclude that through multi-physics modelling, it was possible to identify the optimum air-jet configurations leading to fibre uniformity and its distribution. This work also paves the way for incorporating a vision system to evaluate fibre density in real time.展开更多
Electrical impedance measurements were performed on fine-grained concrete with low volume content of conductive steel and carbon fibres, either as a mono or as a hybrid system. The influences were investigated of the...Electrical impedance measurements were performed on fine-grained concrete with low volume content of conductive steel and carbon fibres, either as a mono or as a hybrid system. The influences were investigated of the applied frequencies, of fibre combinations and of the age of the composites on the impedance. The results show that when the applied frequency is increased from 0.98 Hz to 1000 Hz, the impedance of the fibre composites significantly decreases. At the same time, impedance difference between plain concrete and fibre-reinforced concrete is enhanced. Dramatic drop of impedance takes place over the low frequency range, i.e. 0.98 to approximately 31 Hz. Impedance also depends on the volume content of hybrid fibres. The cementitious composite with the highest content of hybrid fibres (1.0% steel fibres and 0.2% carbon fibres by volume) has the lowest impedance at all measuring frequencies. 0.6% fibres by volume seem to be a turning point, from which the variation of impedance slows down with the fibre content increases. On the other hand, the impedance increment of the fibre-reinforced composites slows down with the age after 28 days, comparing to plain concrete. (Author abstract) 8 Refs.展开更多
The results of an analytical investigation of the flexural behaviour of Steel Fibre Reinforced Concrete (SFRC) beams are presented. The complete response of the SFRC beams under displacement controlled static loading ...The results of an analytical investigation of the flexural behaviour of Steel Fibre Reinforced Concrete (SFRC) beams are presented. The complete response of the SFRC beams under displacement controlled static loading was obtained using nonlinear Finite Element (FE) techniques implemented with the help of ATENA 2D software. Issues relating to the behaviour of SFRC which have a direct bearing on the FE modelling are discussed with relevance to the software employed for the nonlinear analysis. Constitutive models amenable to numerical analysis for steel fibrous concrete are presented. The structural response throughout the loading regime was captured in terms of the load-deflection behaviour, which in addition to the post-peak response characterized the failure mode of the test beams. The crack patterns at crack initiation and at the end of the tests were also recorded. Experimental results from the specimens of two other investigators were used as control values for this investigation. The response of the specimens of this investigation was evaluated in terms of initial tangent stiffness, peak loads and toughness. Good match was obtained between the results from this investigation and corresponding experimentally obtained values, wherever available. The influence of the fibre content is reflected in the observed trends in peak loads, deflection at peak loads and toughness, which are in broad agreement with known behavioral patterns of SFRC.展开更多
This paper describes a series of experimental investigations on seventeen specimens of steel reinforced concrete special shaped(SRCSS) columns under low cyclic reversed loading using parallel crosshead equipment. Nine...This paper describes a series of experimental investigations on seventeen specimens of steel reinforced concrete special shaped(SRCSS) columns under low cyclic reversed loading using parallel crosshead equipment. Nine T-shaped SRC columns, four L-shaped SRC columns and four +-shaped SRC columns were tested to examine the effects of shape steel confi guration, loading angle, axial compressive ratio and shear-span ratio on the behavior(strength, stiffness, energy dissipation, ductility, etc.) of SRCSS column specimens. The failure modes and hysteretic performance of all the specimens were obtained in the tests. Test results demonstrate that the shear-span ratio is the main parameter affecting the failure modes of SRCSS columns. The specimens with small shear-span ratio are prone to shear failure, and the primary failure planes in SRCSS columns are parallel to the loading direction. As a result, there is a symmetry between positive and negative loading directions in the hysteretic curves of the SRCSS columns. The majority of displacement ductility coeffi cients for all the specimens are over 3.0, so that the SRCSS columns demonstrate a better deformation capacity. In addition, the equivalent viscous damping coeffi cients of all the specimens are greater than 0.2, indicating that the seismic behavior of SRCSS columns is adequate. Finally, the superposition theory was used to calculate the limits of axial compressive ratio for the specimens, and it is found that the test axial compressive ratio is close to or smaller than the calculated axial compressive ratio limit.展开更多
A study on the punching shear behavior of 8 slabs with recycled aggregate concrete(RAC)was carried out.The two main factors considered were the recycled coarse aggregate(RCA)replacement percentage and the steel fibre ...A study on the punching shear behavior of 8 slabs with recycled aggregate concrete(RAC)was carried out.The two main factors considered were the recycled coarse aggregate(RCA)replacement percentage and the steel fibre volumetric ratio.The failure pattern,load-displacement curves,energy consumption,and the punching shear capacity of the slabs were intensively investigated.It was concluded that the punching shear capacity,ductility and energy consumption decreased with the increase of RCA replacement percentage.Research findings indicated that the incorporation of steel fibres could not only improve the energy dissipation capacity and the punching shear capacity of the slab,but also effectively improve the integrity of the slab tension surface and thereby changing the trend from typical punching failure pattern to bending-punching failure pattern.On the basis of the test,the punching shear capacity formula of RAC slabs with and without steel fibres was proposed and discussed.展开更多
文摘Based on an engineering background of a deep tunneling in weak rocks, the numerical modeling is used to compare different support schemes of tunnel at great depth in this paper. Focused on the general behaviors of weak rocks at great depth, a tunneling scheme with rock bolting and steel fibre reinforced sprayed concrete is proposed. This scheme is practiced successfully at a deep tunnel in weak rocks in Coal Mine No 10 of Hebi Coal Mining Administration.
文摘The blast resistance of structures used in buildings needs to be investigated due to the increased threat of a terrorist attack. The damage done by Composition B or Powergel to steel fibre reinforced reactive powder concrete (SFRPC) panels and ordinary reinforced concrete (RC) panels of equivalent static flexural strength is compared. A 0.5 kg charge was detonated at a distance of 0.1 m from the 1.3 m×1.0 m×0. 1 m (thick) panels, which were simply supported and spaning 1.3m. Dynamic displacement measurements, high-speed video recording and visual examination of the panels for spall and breach were undertaken. The SFRPC panels withstood the bare charge blast better than the reinforced ordinary concrete panels. Neither type of panel was breached using a 0.5 kg charge. The RC panel exhibited more spalling when Composition B was used. Under successive Composition B loading conditions, the RC panel was breached. In comparison the SFRPC panel was not breached. Exposure to fragmenting charge loading conditions confirmed these performance differences between the SFRPC panel and the reinforced ordinary concrete panel.
基金the Research Project of Specification of Structural Design and Construction of Steel-fibre Reinforced Concrete (CECS38:92)
文摘The effect of steel fibre used in concrete was systematically analyzed by model testing of 30 2-pile thick caps of steel-fibre reinforced concrete, in which the model scale was 1:5. The experiment system composed of a loading device, strain measurement system and a data-acquisition system was used, also an electromechanic centigrade scale, a lens and a Y J-25 static resistance strainometer were used.The experimental results show that the volumetric rate of steel fibre and draw ratio have an important influence on its load-bearing capacity. The incorporation of steel fibre can effectively improve the extension and reduce the thickness of the caps.
基金Project supported by the Indian Council for Cultural Relations,India
文摘This paper reports investigation conducted to study the fatigue performance of steel fibre reinforced concrete (SFRC) containing fibres of mixed aspect ratio. An extensive experimental program was conducted in which 90 flexural fatigue tests were carried out at different stress levels on size 500 mm×100 mm×100 mm SFRC specimens respectively containing 1.0%, 1.5% and 2.0% volume fraction of fibres. About 36 static flexural tests were also conducted to determine the static flexural strength prior to fatigue testing. Each volume fraction of fibres incorporated corrugated mixed steel fibres of size 0.6 mm×2.0 mm×25 mm and 0.6 mm×2.0 mm×50 mm in ratio 50:50 by weight. The results are presented both as S-N relationships, with the maximum fatigue stress expressed as a percentage of the strength under static loading, and as relationships between actually applied fatigue stress and number of loading cycles to failure. Two-million-cycle fatigue strengths of SFRC containing different volume fractions of mixed fibres were obtained and compared with plain concrete.
文摘The influences of adding steel fibres of different lengths up to 3 volume percentages, on the rheological behaviour of an alumina-magnesia-extruded graphite pellet containing castables have been studied using a rheometer. Free-flow measurements have shown that the flow is severely affected by increasing the length of steel fibres. The calculated values of rheological constants indicate that 19 mm and 25 mm fibre up to 2 volume percentage is permitted while one volume percentage of 50 mm fibres severely degrades the rheology of the castable.
基金Financial support from National Key R&D Program of China(2016YFE0125600)National Natural Science Foundation of China(Grant No.51308504)+1 种基金Program for Changjiang Scholars and Innovative Research Team in University of Ministry of Education of China(IRT_16R67),Scientific&Technological Project of Henan Province(152102310068)Training Program of Young-backbone teachers in Universities of Henan Province of China are gratefully acknowledged.
文摘The fibre pullout test was conducted to investigate the influence of the water stability on the bond behaviour between the Magnesium phosphate cement(MPC)matrix and the steel fibre.The composition of the MPC-matrix and the immersion age of the specimens are experimentally investigated.The average bond strength and the pullout energy are investigated by analysing the experimental results.In addition,the microscopic characteristics of the interface transition zone are investigated using scanning electron microscopy(SEM).The experimental results showed that the bond performance between the MPC-matrix and the steel fibre decreased significantly with the increase of the duration of immersion in water.The average bond strength between the steel fibre and the MPC-matrix reduced by more than 50%when the specimens were immersed in the water for 28 days.The effect of the water on the interface between the steel fibre and the MPC-matrix was found to be more significant compared to the composition of the MPC-matrix.In addition,the MgO-KH2PO4 mole ratio of the MPC significantly influenced the water stability of the interface zone between the steel fibre and MPC-matrix.
文摘The mixing of non-woven steel fibres in melt overflow process for use in automotive muffler systems was simulated. The aim was to identify optimum parameters for achieving a good fibre mix. Numerical models of mixing chambers of melt overflow process were developed. Multiphysics analyses involving heat transfer, fluid flow and particle tracking were carried out using COMSOL code. The influence of air jet configurations on the fibre distribution was studied. The fibres settled on the moving bed within the mixing chamber were examined for their uniformity. The effect of additional air jets to the existing chamber in a range of regions was explored. An optimum configuration was identified by analyzing the compactness of the particle clusters deposited in the simulation and validated using pixel data acquired from real time imaging. The results showed that by employing dual air jets at the front end of the chamber, the density of the fibre material has improved. We conclude that through multi-physics modelling, it was possible to identify the optimum air-jet configurations leading to fibre uniformity and its distribution. This work also paves the way for incorporating a vision system to evaluate fibre density in real time.
文摘Electrical impedance measurements were performed on fine-grained concrete with low volume content of conductive steel and carbon fibres, either as a mono or as a hybrid system. The influences were investigated of the applied frequencies, of fibre combinations and of the age of the composites on the impedance. The results show that when the applied frequency is increased from 0.98 Hz to 1000 Hz, the impedance of the fibre composites significantly decreases. At the same time, impedance difference between plain concrete and fibre-reinforced concrete is enhanced. Dramatic drop of impedance takes place over the low frequency range, i.e. 0.98 to approximately 31 Hz. Impedance also depends on the volume content of hybrid fibres. The cementitious composite with the highest content of hybrid fibres (1.0% steel fibres and 0.2% carbon fibres by volume) has the lowest impedance at all measuring frequencies. 0.6% fibres by volume seem to be a turning point, from which the variation of impedance slows down with the fibre content increases. On the other hand, the impedance increment of the fibre-reinforced composites slows down with the age after 28 days, comparing to plain concrete. (Author abstract) 8 Refs.
文摘The results of an analytical investigation of the flexural behaviour of Steel Fibre Reinforced Concrete (SFRC) beams are presented. The complete response of the SFRC beams under displacement controlled static loading was obtained using nonlinear Finite Element (FE) techniques implemented with the help of ATENA 2D software. Issues relating to the behaviour of SFRC which have a direct bearing on the FE modelling are discussed with relevance to the software employed for the nonlinear analysis. Constitutive models amenable to numerical analysis for steel fibrous concrete are presented. The structural response throughout the loading regime was captured in terms of the load-deflection behaviour, which in addition to the post-peak response characterized the failure mode of the test beams. The crack patterns at crack initiation and at the end of the tests were also recorded. Experimental results from the specimens of two other investigators were used as control values for this investigation. The response of the specimens of this investigation was evaluated in terms of initial tangent stiffness, peak loads and toughness. Good match was obtained between the results from this investigation and corresponding experimentally obtained values, wherever available. The influence of the fibre content is reflected in the observed trends in peak loads, deflection at peak loads and toughness, which are in broad agreement with known behavioral patterns of SFRC.
基金National Science Foundation of China under Grant Nos.50908057 and 51268004Open Project of Guangxi Key Laboratory of Disaster Prevention and Structural Safety under Grant No.2012ZDX10Innovation Project of Guangxi Graduate Education under Grant No.YCBZ2012005
文摘This paper describes a series of experimental investigations on seventeen specimens of steel reinforced concrete special shaped(SRCSS) columns under low cyclic reversed loading using parallel crosshead equipment. Nine T-shaped SRC columns, four L-shaped SRC columns and four +-shaped SRC columns were tested to examine the effects of shape steel confi guration, loading angle, axial compressive ratio and shear-span ratio on the behavior(strength, stiffness, energy dissipation, ductility, etc.) of SRCSS column specimens. The failure modes and hysteretic performance of all the specimens were obtained in the tests. Test results demonstrate that the shear-span ratio is the main parameter affecting the failure modes of SRCSS columns. The specimens with small shear-span ratio are prone to shear failure, and the primary failure planes in SRCSS columns are parallel to the loading direction. As a result, there is a symmetry between positive and negative loading directions in the hysteretic curves of the SRCSS columns. The majority of displacement ductility coeffi cients for all the specimens are over 3.0, so that the SRCSS columns demonstrate a better deformation capacity. In addition, the equivalent viscous damping coeffi cients of all the specimens are greater than 0.2, indicating that the seismic behavior of SRCSS columns is adequate. Finally, the superposition theory was used to calculate the limits of axial compressive ratio for the specimens, and it is found that the test axial compressive ratio is close to or smaller than the calculated axial compressive ratio limit.
基金the National Natural Science Foundation of China(NSFC)(Grant No.51438007 and 51661145023).
文摘A study on the punching shear behavior of 8 slabs with recycled aggregate concrete(RAC)was carried out.The two main factors considered were the recycled coarse aggregate(RCA)replacement percentage and the steel fibre volumetric ratio.The failure pattern,load-displacement curves,energy consumption,and the punching shear capacity of the slabs were intensively investigated.It was concluded that the punching shear capacity,ductility and energy consumption decreased with the increase of RCA replacement percentage.Research findings indicated that the incorporation of steel fibres could not only improve the energy dissipation capacity and the punching shear capacity of the slab,but also effectively improve the integrity of the slab tension surface and thereby changing the trend from typical punching failure pattern to bending-punching failure pattern.On the basis of the test,the punching shear capacity formula of RAC slabs with and without steel fibres was proposed and discussed.