期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
A Simulation Study on the Specific Loss Power in Magnetic Hyperthermia in the Presence of a Static Magnetic Field
1
作者 Kenya Murase 《Open Journal of Applied Sciences》 2016年第12期839-851,共13页
Our purpose in this study was to present a method for estimating the specific loss power (SLP) in magnetic hyperthermia in the presence of an external static magnetic field (SMF) and to investigate the SLP values esti... Our purpose in this study was to present a method for estimating the specific loss power (SLP) in magnetic hyperthermia in the presence of an external static magnetic field (SMF) and to investigate the SLP values estimated by this method under various diameters (D) of magnetic nanoparticles (MNPs) and amplitudes (H<sub>0</sub>) and frequencies (f) of an alternating magnetic field (AMF). In our method, the SLP was calculated by solving the magnetization relaxation equation of Shliomis numerically, in which the magnetic field strength at time t (H(t)) was assumed to be given by , with H<sub>s</sub> being the strength of the SMF. We also investigated the SLP values in the case when the SMF with a field-free point (FFP) generated by two solenoid coils was used. The SLP value in the quasi steady state (SLP<sub>qss</sub>) decreased with increasing H<sub>s</sub>. The plot of the SLP<sub>qss</sub> values against the position from the FFP became narrow as the gradient strength of the SMF (G<sub>s</sub>) increased. Conversely, it became broad as G<sub>s</sub> decreased. These results suggest that the temperature rise and the area of local heating in magnetic hyperthermia can be controlled by varying the H<sub>s</sub> and G<sub>s</sub> values, respectively. In conclusion, our method will be useful for estimating the SLP in the presence of both the AMF and SMF and for designing an effective local heating system for magnetic hyperthermia in order to reduce the risk of overheating surrounding healthy tissues. 展开更多
关键词 Magnetic Hyperthermia Magnetic Nanoparticle specific loss Power Alternating Magnetic Field Static Magnetic Field Magnetization Relaxation Field-Free Point
下载PDF
Methods for Estimating Specific Loss Power in Magnetic Hyperthermia Revisited
2
作者 Kenya Murase 《Open Journal of Applied Sciences》 2016年第12期815-825,共12页
Our purpose in this study was to present three methods for estimating specific loss power (SLP) in magnetic hyperthermia with use of an alternating magnetic field (AMF) and magnetic nanoparticles (MNPs) and to compare... Our purpose in this study was to present three methods for estimating specific loss power (SLP) in magnetic hyperthermia with use of an alternating magnetic field (AMF) and magnetic nanoparticles (MNPs) and to compare the SLP values estimated by the three methods using simulation studies under various diameters of MNPs (D), amplitudes (H<sub>0</sub>) and frequencies of AMF (f). In the first method, the SLP was calculated by solving the magnetization relaxation equation of Shliomis numerically (SLP<sub>1</sub>). In the second method, the SLP was obtained by solving Shliomis’ relaxation equation using the complex susceptibility (SLP<sub>2</sub>). The third method was based on Rosensweig’s model (SLP<sub>3</sub>). The SLP<sub>3</sub> value changed largely depending on the magnetic field strength (H) in the Langevin parameter (§) and it became maximum (SLP<sub>3</sub><sup>max</sup>) and minimum (SLP<sub>3</sub><sup>min</sup>) when H was 0 and ±H<sub>0</sub>, respectively. The relative difference between SLP<sub>1</sub> and SLP<sub>2</sub> was the largest and increased with increasing D and H<sub>0</sub>, whereas that between SLP<sub>1</sub> and was the smallest and was almost constant regardless of D and H<sub>0</sub>, suggesting that H in ξ should be taken as H<sub>0</sub> in estimating the SLP using Rosensweig’s model. In conclusion, this study will be useful for optimizing the parameters of AMF in magnetic hyperthermia and for the optimal design of MNPs for magnetic hyperthermia. 展开更多
关键词 Magnetic Hyperthermia Magnetic Nanoparticle specific loss Power Alternating Magnetic Field Magnetization Relaxation
下载PDF
Progress in ileal endogenous amino acid flow research in poultry 被引量:6
3
作者 V.Ravindran 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2021年第2期415-425,共11页
The progress in our understanding of the endogenous protein concept over the past century is reviewed.Nondietary proteins found in the digesta at the terminal ileum of poultry,known as endogenous protein loss,are comp... The progress in our understanding of the endogenous protein concept over the past century is reviewed.Nondietary proteins found in the digesta at the terminal ileum of poultry,known as endogenous protein loss,are comprised of digestive secretions,mucus and sloughed gut epithelial cells.The measurement of this loss is of fundamental importance because it is an indicator of gut metabolism and is essential to adjust apparent estimates of ileal amino acid digestibility.The ileal endogenous amino acid losses comprise of two components,namely basal and specific losses.The basal losses are fixed and associated with feed dry matter intake,whereas the specific losses are variable and induced by the presence of dietary components such as fibre and anti-nutrients.Currently there is no methodology available to directly measure the specific endogenous losses and these losses are calculated by determining the basal and total(basal plus specific)losses and,then subtracting the basal losses from total losses.The seminal features,specific applications and shortcomings of available methodologies are briefly outlined as well as the practical challenges faced in using the published endogenous amino acid loss values for true digestibility corrections.The relevance of taurine as a component of endogenous protein flow in poultry is identified for the first time. 展开更多
关键词 Basal loss Digestible amino acids Endogenous amino acid losses POULTRY specific loss
下载PDF
Early Stage CAD-Compliant Energy Performance Assessment Method
4
作者 Jarek Kumitski Targo Kalamees Teet Tark 《Journal of Energy and Power Engineering》 2013年第9期1662-1668,共7页
A simple calculator for early stage energy performance assessment in residential buildings was developed and partially validated in this study. The calculator is based on the correlation of heat loss and energy need f... A simple calculator for early stage energy performance assessment in residential buildings was developed and partially validated in this study. The calculator is based on the correlation of heat loss and energy need for heating and has fixed internal heat gains as intended for compliance assessment. With the calculator, the effect of any parameter implemented can be immediately seen on delivered and primary energy. Because of simple equations, it is suitable for implementation into CAD (computer aided design) design tools including basic BIM (building information modeling) data. Results showed that the accuracy of the correlation for the cases with practical relevance was not worse than 14% of the energy need of space heating. This applies for passive house insulation level; for less insulated building envelopes, the deviations were smaller. This 14% equals to only 3 kWh/(m2.a), i.e., the percentage difference in the total delivered and primary energy was much lower because of other components in the energy balance. The deviations determined were implemented in the calculator as safety margin. Results prove that simple energy performance assessment based on specific heat loss coefficient is well justified for early stage energy analyses as well as for compliance assessment implemented in Estonian regulation. 展开更多
关键词 Energy performance specific heat loss energy calculator early stage energy assessment compliance assessment.
下载PDF
Identification of deuterons at BESIII
5
作者 王维 郑波 +1 位作者 秦佳佳 王至勇 《Chinese Physics C》 SCIE CAS CSCD 2024年第1期1-6,共6页
The identification of deuterons with momenta in the range of 0.52−0.72 GeV/c is studied with specific ionization energy loss information using a data sample collected by the BESIII detector at center-of-mass energies ... The identification of deuterons with momenta in the range of 0.52−0.72 GeV/c is studied with specific ionization energy loss information using a data sample collected by the BESIII detector at center-of-mass energies between 4.009 and 4.946 GeV.Clean deuteron samples are selected using time of flight information.For all data samples,the deuteron identification efficiencies are higher than 95%,with a maximum difference of%between data and Monte Carlo simulation.This verifies the effectiveness of the deuteron identification method based on specific ionization energy loss and provides valuable information for future studies on processes involving deuterons in the final state at BESIII. 展开更多
关键词 specific ionization energy loss BESIII identification of deuterons particle identification efficiency
原文传递
Investigation on flow and heat transfer characteristics in rectangular channel with drop-shaped pin fins 被引量:4
6
作者 Fengming Wang Jingzhou Zhang Suofang Wang 《Propulsion and Power Research》 SCIE 2012年第1期64-70,共7页
The flow and heat transfer characteristics inside a rectangular channel embedded with pin fins were numerically and experimentally investigated.Several differently shaped pin fins(i.e.,circular,elliptical,and drop-sha... The flow and heat transfer characteristics inside a rectangular channel embedded with pin fins were numerically and experimentally investigated.Several differently shaped pin fins(i.e.,circular,elliptical,and drop-shaped)with the same cross-sectional areas were compared in a staggered arrangement.The Reynolds number based on the obstructed section hydraulic diameter(defined as the ratio of the total wetted surface area to the open duct volume available for flow)was varied from 4800 to 8200.The more streamlined drop-shaped pin fins were better at delaying or suppressing separation of the flow passing through them,which decreased the aerodynamic penalty compared to circular pin fins.The heat transfer enhancement of the drop-shaped pin fins was less than that of the circular pin fins.In terms of specific performance parameters,drop-shaped pin fins are a promising alternative configuration to circular pin fins. 展开更多
关键词 Enhanced heat transfer Pin fins Drop-shaped pin fins Pressure loss specific friction loss
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部