Real-time monitoring of nitrogen status in rice and wheat plant is of significant importance for nitrogen diagnosis, fertilization recommendation, and productivity prediction. With 11 field experiments involving diffe...Real-time monitoring of nitrogen status in rice and wheat plant is of significant importance for nitrogen diagnosis, fertilization recommendation, and productivity prediction. With 11 field experiments involving different cultivars, nitrogen rates, and water regimes, time-course measurements were taken of canopy hyperspeetral reflectance between 350-2 500 nm and leaf nitrogen accumulation (LNA) in rice and wheat. A new spectral analysis method through the consideration of characteristics of canopy components and plant growth status varied with phenological growth stages was designed to explore the common central bands in rice and wheat. Comprehensive analyses were made on the quantitative relationships of LNA to soil adjusted vegetation index (SAVI) and ratio vegetation index (RVI) composed of any two bands between 350-2 500 nm in rice and wheat. The results showed that the ranges of indicative spectral reflectance were largely located in 770-913 and 729-742 nm in both rice and wheat. The optimum spectral vegetation index for estimating LNA was SAVI (R822, R738) during the early-mid period (from jointing to booting), and it was RVI (Rs22, R73s) during the mid-late period (from heading to filling) with the common central bands of 822 and 738 nm in rice and wheat. Comparison of the present spectral vegetation indices with previously reported vegetation indices gave a satisfactory performance in estimating LNA. It is concluded that the spectral bands of 822 and 738 nm can be used as common reflectance indicators for monitoring leaf nitrogen accumulation in rice and wheat.展开更多
We analyzed the infrared 0R)-near infrared (NIR) 2D correlation spectra of drugs perturbed by temperature. By identification of functional groups by IR spectrum and by the correlation analysis of IR-NIR spectrum, w...We analyzed the infrared 0R)-near infrared (NIR) 2D correlation spectra of drugs perturbed by temperature. By identification of functional groups by IR spectrum and by the correlation analysis of IR-NIR spectrum, we identified the characteristic spectral bands that were closely related to the structure of a drug substance of interest. These characteristic spectral bands were relatively less interfered by other ingredients for analysis by the NIR correlation coefficient method. With these characteristic spectral bands, the accuracy of screening illegally added Sildenafil citrate, Tadalafil and Metforrnin hydrochloride in Chinese patent drugs and healthcare products reached about 90%, which met the requirements of rapid screening.展开更多
A new miniature spectrometer with two entrance slits is proposed to expand the spectral band. The proposed spectrometer is designed such that the two entrance slits share the same concave grating and detector array. T...A new miniature spectrometer with two entrance slits is proposed to expand the spectral band. The proposed spectrometer is designed such that the two entrance slits share the same concave grating and detector array. The two slits are located at different positions such that the spectral range of the same light source incident on the detector array varies greatly between the two slits. Only one of the two slits is illuminated at a given time; as such, the two spectral ranges are sequentially measured. Theoretical calculation and experimentation are conducted to verify the proposed design.展开更多
Hyper-spectral imaging spectrometer has high spatial and spectral resolution. Its radiometric calibration needs the knowledge of the sources used with high spectral resolution. In order to satisfy the requirement of s...Hyper-spectral imaging spectrometer has high spatial and spectral resolution. Its radiometric calibration needs the knowledge of the sources used with high spectral resolution. In order to satisfy the requirement of source, an on-orbit radiometric calibration method is designed in this paper. This chain is based on the spectral inversion accuracy of the calibration light source. We compile the genetic algorithm progress which is used to optimize the channel design of the transfer radiometer and consider the degradation of the halogen lamp, thus realizing the high accuracy inversion of spectral curve in the whole working time. The experimental results show the average root mean squared error is 0.396%, the maximum root mean squared error is 0.448%, and the relative errors at all wavelengths are within 1% in the spectral range from 500 nm to 900 nm during 100 h operating time. The design lays a foundation for the high accuracy calibration of imaging spectrometer.展开更多
This paper addresses the problem of single-channel speech enhancement in the adverse environment. The critical-band rate scale based on improved multi-band spectral subtraction is investigated in this study for enhanc...This paper addresses the problem of single-channel speech enhancement in the adverse environment. The critical-band rate scale based on improved multi-band spectral subtraction is investigated in this study for enhancement of single-channel speech. In this work, the whole speech spectrum is divided into different non-uniformly spaced frequency bands in accordance with the critical-band rate scale of the psycho-acoustic model and the spectral over-subtraction is carried-out separately in each band. In addition, for the estimation of the noise from each band, the adaptive noise estimation approach is used and does not require explicit speech silence detection. The noise is estimated and updated by adaptively smoothing the noisy signal power in each band. The smoothing parameter is controlled by a-posteriori signal-to-noise ratio (SNR). For the performance analysis of the proposed algorithm, the objective measures, such as, SNR, segmental SNR, and perceptual evaluations of the speech quality are conducted for the variety of noises at different levels of SNRs. The speech spectrogram and objective evaluations of the proposed algorithm are compared with other standard speech enhancement algorithms and proved that the musical structure of the remnant noise and background noise is better suppressed by the proposed algorithm.展开更多
基金supported by the National High-Tech R&D Program of China(2011AA100703)the National Natural Science Foundation of China(30900868)+2 种基金the Natural Science Foundation of Jiangsu Province, China(BK2010453)the Academic Program Development of Jiangsu Higher Education Institutions, China(PAPD)the Science and Technology Support Plan of Jiangsu Province, China(BE2011351)
文摘Real-time monitoring of nitrogen status in rice and wheat plant is of significant importance for nitrogen diagnosis, fertilization recommendation, and productivity prediction. With 11 field experiments involving different cultivars, nitrogen rates, and water regimes, time-course measurements were taken of canopy hyperspeetral reflectance between 350-2 500 nm and leaf nitrogen accumulation (LNA) in rice and wheat. A new spectral analysis method through the consideration of characteristics of canopy components and plant growth status varied with phenological growth stages was designed to explore the common central bands in rice and wheat. Comprehensive analyses were made on the quantitative relationships of LNA to soil adjusted vegetation index (SAVI) and ratio vegetation index (RVI) composed of any two bands between 350-2 500 nm in rice and wheat. The results showed that the ranges of indicative spectral reflectance were largely located in 770-913 and 729-742 nm in both rice and wheat. The optimum spectral vegetation index for estimating LNA was SAVI (R822, R738) during the early-mid period (from jointing to booting), and it was RVI (Rs22, R73s) during the mid-late period (from heading to filling) with the common central bands of 822 and 738 nm in rice and wheat. Comparison of the present spectral vegetation indices with previously reported vegetation indices gave a satisfactory performance in estimating LNA. It is concluded that the spectral bands of 822 and 738 nm can be used as common reflectance indicators for monitoring leaf nitrogen accumulation in rice and wheat.
基金National Key Technology R & D Program-On-site Rapid Identification of Drug Research Project (Grant No. 2008BAI55B06)
文摘We analyzed the infrared 0R)-near infrared (NIR) 2D correlation spectra of drugs perturbed by temperature. By identification of functional groups by IR spectrum and by the correlation analysis of IR-NIR spectrum, we identified the characteristic spectral bands that were closely related to the structure of a drug substance of interest. These characteristic spectral bands were relatively less interfered by other ingredients for analysis by the NIR correlation coefficient method. With these characteristic spectral bands, the accuracy of screening illegally added Sildenafil citrate, Tadalafil and Metforrnin hydrochloride in Chinese patent drugs and healthcare products reached about 90%, which met the requirements of rapid screening.
基金supported by the National Natural Science Foundation of China(No.61205167)the China Postdoctoral Science Foundation Funded Project(No.2015M571033)
文摘A new miniature spectrometer with two entrance slits is proposed to expand the spectral band. The proposed spectrometer is designed such that the two entrance slits share the same concave grating and detector array. The two slits are located at different positions such that the spectral range of the same light source incident on the detector array varies greatly between the two slits. Only one of the two slits is illuminated at a given time; as such, the two spectral ranges are sequentially measured. Theoretical calculation and experimentation are conducted to verify the proposed design.
基金supported by the National Natural Science Foundation of China(No.41474161)the National High Technology Research and Development Program of China(No.2015AA123703)
文摘Hyper-spectral imaging spectrometer has high spatial and spectral resolution. Its radiometric calibration needs the knowledge of the sources used with high spectral resolution. In order to satisfy the requirement of source, an on-orbit radiometric calibration method is designed in this paper. This chain is based on the spectral inversion accuracy of the calibration light source. We compile the genetic algorithm progress which is used to optimize the channel design of the transfer radiometer and consider the degradation of the halogen lamp, thus realizing the high accuracy inversion of spectral curve in the whole working time. The experimental results show the average root mean squared error is 0.396%, the maximum root mean squared error is 0.448%, and the relative errors at all wavelengths are within 1% in the spectral range from 500 nm to 900 nm during 100 h operating time. The design lays a foundation for the high accuracy calibration of imaging spectrometer.
文摘This paper addresses the problem of single-channel speech enhancement in the adverse environment. The critical-band rate scale based on improved multi-band spectral subtraction is investigated in this study for enhancement of single-channel speech. In this work, the whole speech spectrum is divided into different non-uniformly spaced frequency bands in accordance with the critical-band rate scale of the psycho-acoustic model and the spectral over-subtraction is carried-out separately in each band. In addition, for the estimation of the noise from each band, the adaptive noise estimation approach is used and does not require explicit speech silence detection. The noise is estimated and updated by adaptively smoothing the noisy signal power in each band. The smoothing parameter is controlled by a-posteriori signal-to-noise ratio (SNR). For the performance analysis of the proposed algorithm, the objective measures, such as, SNR, segmental SNR, and perceptual evaluations of the speech quality are conducted for the variety of noises at different levels of SNRs. The speech spectrogram and objective evaluations of the proposed algorithm are compared with other standard speech enhancement algorithms and proved that the musical structure of the remnant noise and background noise is better suppressed by the proposed algorithm.