Direct current(DC)bus voltage stability is essential for the stable and reliable operation of a DC system.If an oscillation source can be quickly and accurately localized,the oscillation can be adequately eliminated.W...Direct current(DC)bus voltage stability is essential for the stable and reliable operation of a DC system.If an oscillation source can be quickly and accurately localized,the oscillation can be adequately eliminated.We propose a method based on the power spectral density for identifying the voltage oscillation source.Specifically,a DC distribution network model combined with the component connection method is developed,and the network is separated into multiple power modules.Compared with a conventional method,the proposed method does not require determining the model parameters of the entire power grid,which is typically challenging.Furthermore,combined with a novel judgment index,the oscillation source can be identified more intuitively and clearly to enhance the applicability to real power grids.The performance of the proposed method has been evaluated using the MATLAB/Simulink software and PLECS RT Box experimental platform.The simulation and experimental results verify that the proposed method can accurately identify oscillation sources in a DC distribution network.展开更多
Using highly pure graphite rod and B4C/graphite composite rod as electrods, some macroscopic amounts of boron-doped fullerenes, such as C60-nBn and C70-nBn (n=1,2,3) are syn-thesized by DC arc burning method and extra...Using highly pure graphite rod and B4C/graphite composite rod as electrods, some macroscopic amounts of boron-doped fullerenes, such as C60-nBn and C70-nBn (n=1,2,3) are syn-thesized by DC arc burning method and extracted by o-xylene from the soots under nitrogen for the first time. The boron-doped fullerenes are characterized by FDMS.展开更多
基金supported in part by the National Natural Science Foundation of China(No.51807112)。
文摘Direct current(DC)bus voltage stability is essential for the stable and reliable operation of a DC system.If an oscillation source can be quickly and accurately localized,the oscillation can be adequately eliminated.We propose a method based on the power spectral density for identifying the voltage oscillation source.Specifically,a DC distribution network model combined with the component connection method is developed,and the network is separated into multiple power modules.Compared with a conventional method,the proposed method does not require determining the model parameters of the entire power grid,which is typically challenging.Furthermore,combined with a novel judgment index,the oscillation source can be identified more intuitively and clearly to enhance the applicability to real power grids.The performance of the proposed method has been evaluated using the MATLAB/Simulink software and PLECS RT Box experimental platform.The simulation and experimental results verify that the proposed method can accurately identify oscillation sources in a DC distribution network.
文摘Using highly pure graphite rod and B4C/graphite composite rod as electrods, some macroscopic amounts of boron-doped fullerenes, such as C60-nBn and C70-nBn (n=1,2,3) are syn-thesized by DC arc burning method and extracted by o-xylene from the soots under nitrogen for the first time. The boron-doped fullerenes are characterized by FDMS.