期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
A Highly Compact Third-Order Silicon Elliptical Micro-Ring Add-Drop Filter with a Large Free Spectral Range 被引量:1
1
作者 关欢 李智勇 +2 位作者 沈海华 王睿 俞育德 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第3期61-63,共3页
We demonstrate a highly compact third-order elliptical micro-ring add-drop filter based on a silicon-on-insulator wafer. The elliptical micro-ring resonator has a major radius of 6μm (minor radius of 4.112μm) and ... We demonstrate a highly compact third-order elliptical micro-ring add-drop filter based on a silicon-on-insulator wafer. The elliptical micro-ring resonator has a major radius of 6μm (minor radius of 4.112μm) and a large free spectral range of 18 nm. Experimental results show a box-like channel dropping response, which has a 3 dB bandwidth of -2.7nm, high out-of-band signal rejection of around 40dB and a very low drop loss (〈0.5dB). Simulation agrees well with the experiments. The footprint of the whole chip is only 0.0003mm2. 展开更多
关键词 FSR A Highly Compact Third-Order Silicon Elliptical Micro-Ring Add-Drop Filter with a Large Free spectral range
下载PDF
Impact of cavity symmetry on mode suppression and increase of free spectral range in solid-state dye microlaser
2
作者 Sergei Popov Sebastien Ricciardi +1 位作者 Ari T.Friberg Sergey Sergeyev 《Chinese Optics Letters》 SCIE EI CAS CSCD 2007年第11期651-653,共3页
We describe modeling the solid-state dye laser with the microcavity size comparable to light wavelength. Certain symmetry in the allocation of gain material leads to depletion of odd longitudinal modes that, in turn, ... We describe modeling the solid-state dye laser with the microcavity size comparable to light wavelength. Certain symmetry in the allocation of gain material leads to depletion of odd longitudinal modes that, in turn, increases the tunability range of the microlaser. We provide simple physical explanation for the modeling results. 展开更多
关键词 MODE Impact of cavity symmetry on mode suppression and increase of free spectral range in solid-state dye microlaser free
原文传递
Dynamic Free-Spectral-Range Measurement for Fiber Resonator Based on Digital-Heterodyne Optical Phase-Locked Loop
3
作者 Hongchen Jiao Tao Wang +2 位作者 Heli Gao Lishuang Feng Honghao Ma 《Optics and Photonics Journal》 2021年第8期332-340,共9页
<div style="text-align:justify;"> We propose a novel scheme, based on digital-heterodyne optical phase-locked loop with whole-fiber circuit, to dynamically measure the free-spectral-range of a fiber re... <div style="text-align:justify;"> We propose a novel scheme, based on digital-heterodyne optical phase-locked loop with whole-fiber circuit, to dynamically measure the free-spectral-range of a fiber resonator. The optical phase-locked loop is established with a differential frequency-modulation module consists of a pair of acousto-optic modulators. The resonance-tracking loop is derived with the Pound-Drever-Hall technique for locking the heterodyne frequency of the OPLL on the frequency difference between adjacent resonance modes. A stable locking accuracy of about 7 × 10<sup>?9</sup> and a dynamic locking accuracy of about 5 × 10<sup>?8</sup> are achieved with the FSR of 8.155 MHz, indicating a bias stability of the resonator fiber optic gyro of about 0.1?/h with 10 Hz bandwidth. In addition, the thermal drift coefficient of the FSR is measured as 0.1 Hz/?C. This shows remarkable potential for realizing advanced optical measurement systems, such as the resonant fiber optic gyro, and so on. </div> 展开更多
关键词 Free spectral range Fiber Resonator Dynamic Measurement Digital-Heterodyne Optical Phase-Locked Loop Resonant Fiber Optic Gyro
下载PDF
Variable selection in near infrared spectroscopy for quantitative models of homologous analogs of cephalosporins
4
作者 Yan-Chun Feng Zhen Ni Chang-Qin Hu 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2014年第4期91-100,共10页
Two universal spectral ranges(4550-4100 cm^(-1) and 6190-5510 cm^(-1))for construction of quantitative models of homologous analogs of cephalosporins were proposed by evaluating theperformance of five spectral ranges ... Two universal spectral ranges(4550-4100 cm^(-1) and 6190-5510 cm^(-1))for construction of quantitative models of homologous analogs of cephalosporins were proposed by evaluating theperformance of five spectral ranges and their combinations,using three data sets of cephalos-porins for injection,ie.,cefuroxime sodium,cetriaxone sodium and cefoperazone sodium.Subsequently,the proposed ranges were validated by using eight calibration sets of otherhomologous analogs of cephalosporins for injection,namely cefmenoxime hydrochloride,ceftezole sodium,cefmetazole,cefoxitin sodium,cefotaxime sodium,cefradine,cephazolin sodium and ceftizoxime sodium.All the constructed quantitative models for the eight kinds of cephalosporinsusing these universal ranges could fulill the requirements for quick quantification.After that,competitive adaptive reweighted sampling(CARS)algorithm and infrared(IR)-near infrared(NIR)two-dimensional(2D)correlation spectral analysis were used to determine the scientific basis of these two spectral ranges as the universal regions for the construction of quantitativemodels of cephalosporins.The CAR.S algorithm demonstrated that the ranges of 4550-4100 cm^(-1) and 6190-5510 cm^(-1) included some key wavenumbers which could be attributed to content changes of cephalosporins.The IR-NIR 2D spectral analysis showed that certain wavenumbersin these two regions have strong correlations to the structures of those cephalosporins that wereeasy to degrade. 展开更多
关键词 Near infrared spectroscopy CEPHALOSPORINS QUANTITATION spectral range selection
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部