Injecting phase calibration (PCAL) signals to the feed horn of the observation system and analyzing the output response signals of the spectrometer, we measured the working performance of a 4096-channel digital auto...Injecting phase calibration (PCAL) signals to the feed horn of the observation system and analyzing the output response signals of the spectrometer, we measured the working performance of a 4096-channel digital autocalibration spectrometer. The results demonstrate that the spectrometer has a fine working performance: (1) the channels are distributed uniformly in the spectrometer; (2) line drift produces little effect on the observation results; (3) spectral resolution shows little changes with observation time. The distribution of the frequency resolution in an 80 MHz bandwidth was measured. A trial observation on the two molecular spectral lines of H2CO and H110α taken with this spectrometer is described.展开更多
The cryogenic ground support equipment (CGSE) is an important part of Alpha Magnetic Spectrometer-02 (AMS-02) experiment which is a particle physics experiment. CGSE is used to cool down the superconducting magnet of ...The cryogenic ground support equipment (CGSE) is an important part of Alpha Magnetic Spectrometer-02 (AMS-02) experiment which is a particle physics experiment. CGSE is used to cool down the superconducting magnet of AMS-02 to its operating temperature of 1.8K and to fill the magnet helium tank with superfluid helium. This paper introduces the control system of CGSE and presents the performance of the system.展开更多
基金Supported by the National Natural Science Foundation of China.
文摘Injecting phase calibration (PCAL) signals to the feed horn of the observation system and analyzing the output response signals of the spectrometer, we measured the working performance of a 4096-channel digital autocalibration spectrometer. The results demonstrate that the spectrometer has a fine working performance: (1) the channels are distributed uniformly in the spectrometer; (2) line drift produces little effect on the observation results; (3) spectral resolution shows little changes with observation time. The distribution of the frequency resolution in an 80 MHz bandwidth was measured. A trial observation on the two molecular spectral lines of H2CO and H110α taken with this spectrometer is described.
基金the National Basic Research Program(973) of China (No. 2004CB720703)
文摘The cryogenic ground support equipment (CGSE) is an important part of Alpha Magnetic Spectrometer-02 (AMS-02) experiment which is a particle physics experiment. CGSE is used to cool down the superconducting magnet of AMS-02 to its operating temperature of 1.8K and to fill the magnet helium tank with superfluid helium. This paper introduces the control system of CGSE and presents the performance of the system.