DNA analysis is the core of biotechnology applied in petroleum resources and engineering. Traditionally accurate determination of DNA purity and concentration by spectrometer is the first and critical step for downstr...DNA analysis is the core of biotechnology applied in petroleum resources and engineering. Traditionally accurate determination of DNA purity and concentration by spectrometer is the first and critical step for downstream molecular biology research. In this study, three different spectrophotometry methods, BPM, NDTT and NPMTTZ were compared for their performance in determining DNA concentration and purity in 32 oil samples, and molecule methods like quantitative real-time PCR (qPCR) and high-throughput sequence were also performed to help assess the accuracy of the three methods in determining DNA concentration and purity. For ordinary heavy oil (OHO), extra heavy oil (EHO) and super heavy oil (SHO), the characteristics of high viscosity (η), density (ρ) and resin plus asphaltene content will affect the DNA extraction and UV determination. The DNA concentration was decreased as density increased: OHO (11.46 ± 18.34 ng/μL), EHO (6.68 ± 9.67 ng/μL) and SHO (6.20 ± 7.83 ng/μL), and the DNA purity was on the reverse: OHO (1.31 ± 0.27), EHO (1.54 ± 0.20), and SHO (1.83 ± 0.32). The results suggest that spectrophotometry such as BPM and NPMTTZ are qualitatively favorite methods as the quick non-consumable methods in determining DNA concentration and purity of medium oil and heavy oil.展开更多
[Objectives] To establish a determination method for the content of total lignanoids in Tangjiangshenkang granules. [Methods] Two-wavelength ultraviolet spectrophotometry (TWBS) was used to scan arctiin control soluti...[Objectives] To establish a determination method for the content of total lignanoids in Tangjiangshenkang granules. [Methods] Two-wavelength ultraviolet spectrophotometry (TWBS) was used to scan arctiin control solution, chlorogenic acid control solution and Tangjiangshenkang granule test solution in the range of 200-400 nm. In the ultraviolet scanning diagram of arctiin reference solution, the maximum absorption wavelength of 280 nm was determined as the determination wavelength λ 1, the detection wavelength in the ultraviolet scanning diagram of chlorogenic acid reference solution ( λ 1=280 nm) was determined, and 350 nm was the reference wavelength λ 2;the content of total lignosides in Tangjiangshenkang granules was determined with arctiin as the reference substance. [Results] The precision, accuracy, and durability of this method were fine. The concentration of arctiin was linearly correlated with the absorbance difference in the range of 0.007 95-0.071 55 mg/mL ( r =0. 999 9). The average recovery of arctiin was 100.8%, and the RSD value was 1.04% ( n =6). Calculated as arctiin, three batches of Tangjiangshenkang granules contain no less than 20% of total lignosides. [Conclusions] The method has the advantages of simple operation, good accuracy, precision and reliable stability. It can be used as the content determination and quality control method of total lignosides in Tangjiangshenkang granules.展开更多
A method for the determination of trace mercury in water samples by hydride generation atomic absorption spectrophotometry after cloud point extraction was proposed in the present work. The effects of pH, concentratio...A method for the determination of trace mercury in water samples by hydride generation atomic absorption spectrophotometry after cloud point extraction was proposed in the present work. The effects of pH, concentration of surfactant, and equilibration time on cloud point extraction were discussed. The enhancement factor of 20 and the detection limit of 0.039 μg/L were obtained for mercury with relative standard deviation of 4.8% (n = 11).展开更多
Copper-based azide(Cu(N_(3))2 or CuN_(3),CA)chips synthesized by in-situ azide reaction and utilized in miniaturized explosive systems has become a hot research topic in recent years.However,the advantages of in-situ ...Copper-based azide(Cu(N_(3))2 or CuN_(3),CA)chips synthesized by in-situ azide reaction and utilized in miniaturized explosive systems has become a hot research topic in recent years.However,the advantages of in-situ synthesis method,including small size and low dosage,bring about difficulties in quantitative analysis and differences in ignition capabilities of CA chips.The aim of present work is to develop a simplified quantitative analysis method for accurate and safe analysis of components in CA chips to evaluate and investigate the corresponding ignition ability.In this work,Cu(N_(3))2 and CuN_(3)components in CA chips were separated through dissolution and distillation by utilizing the difference in solubility and corresponding content was obtained by measuring N_(3)-concentration through spectrophotometry.The spectrophotometry method was optimized by studying influencing factors and the recovery rate of different separation methods was studied,ensuring the accuracy and reproducibility of test results.The optimized method is linear in range from 1.0-25.0 mg/L,with a correlation coefficient R^(2)=0.9998,which meets the requirements of CA chips with a milligram-level content test.Compared with the existing ICP method,component analysis results of CA chips obtained by spectrophotometry are closer to real component content in samples and have satisfactory accuracy.Moreover,as its application in miniaturized explosive systems,the ignition ability of CA chips with different component contents for direct ink writing CL-20 and the corresponding mechanism was studied.This study provided a basis and idea for the design and performance evaluation of CA chips in miniaturized explosive systems.展开更多
基金supported by grants from the PetroChina-CUP Major Strategic Cooperation Projects(ZLZX2020010805,ZLZX2020020405)National Natural Science Foundation of China(41373086)+3 种基金National Science and Technology Major Project(No.2016ZX05050011,2016ZX05040002)Beijing Nova Program and Leading Talent Culturing Cooperative Projects(No.Z161100004916033)Beijing Higher Education Young Elite Teacher Project(No.YETP0670)Outstanding Young Excellent Teachers Foundation of China University of Petroleum(Beijing)(KYJJ2012-01-10).
文摘DNA analysis is the core of biotechnology applied in petroleum resources and engineering. Traditionally accurate determination of DNA purity and concentration by spectrometer is the first and critical step for downstream molecular biology research. In this study, three different spectrophotometry methods, BPM, NDTT and NPMTTZ were compared for their performance in determining DNA concentration and purity in 32 oil samples, and molecule methods like quantitative real-time PCR (qPCR) and high-throughput sequence were also performed to help assess the accuracy of the three methods in determining DNA concentration and purity. For ordinary heavy oil (OHO), extra heavy oil (EHO) and super heavy oil (SHO), the characteristics of high viscosity (η), density (ρ) and resin plus asphaltene content will affect the DNA extraction and UV determination. The DNA concentration was decreased as density increased: OHO (11.46 ± 18.34 ng/μL), EHO (6.68 ± 9.67 ng/μL) and SHO (6.20 ± 7.83 ng/μL), and the DNA purity was on the reverse: OHO (1.31 ± 0.27), EHO (1.54 ± 0.20), and SHO (1.83 ± 0.32). The results suggest that spectrophotometry such as BPM and NPMTTZ are qualitatively favorite methods as the quick non-consumable methods in determining DNA concentration and purity of medium oil and heavy oil.
基金Supported by Major Science and Technology Project"Major New Drug Innovation".
文摘[Objectives] To establish a determination method for the content of total lignanoids in Tangjiangshenkang granules. [Methods] Two-wavelength ultraviolet spectrophotometry (TWBS) was used to scan arctiin control solution, chlorogenic acid control solution and Tangjiangshenkang granule test solution in the range of 200-400 nm. In the ultraviolet scanning diagram of arctiin reference solution, the maximum absorption wavelength of 280 nm was determined as the determination wavelength λ 1, the detection wavelength in the ultraviolet scanning diagram of chlorogenic acid reference solution ( λ 1=280 nm) was determined, and 350 nm was the reference wavelength λ 2;the content of total lignosides in Tangjiangshenkang granules was determined with arctiin as the reference substance. [Results] The precision, accuracy, and durability of this method were fine. The concentration of arctiin was linearly correlated with the absorbance difference in the range of 0.007 95-0.071 55 mg/mL ( r =0. 999 9). The average recovery of arctiin was 100.8%, and the RSD value was 1.04% ( n =6). Calculated as arctiin, three batches of Tangjiangshenkang granules contain no less than 20% of total lignosides. [Conclusions] The method has the advantages of simple operation, good accuracy, precision and reliable stability. It can be used as the content determination and quality control method of total lignosides in Tangjiangshenkang granules.
文摘A method for the determination of trace mercury in water samples by hydride generation atomic absorption spectrophotometry after cloud point extraction was proposed in the present work. The effects of pH, concentration of surfactant, and equilibration time on cloud point extraction were discussed. The enhancement factor of 20 and the detection limit of 0.039 μg/L were obtained for mercury with relative standard deviation of 4.8% (n = 11).
基金the financial support provided by the National Natural Science Foundation of China(Grant No.11872013).
文摘Copper-based azide(Cu(N_(3))2 or CuN_(3),CA)chips synthesized by in-situ azide reaction and utilized in miniaturized explosive systems has become a hot research topic in recent years.However,the advantages of in-situ synthesis method,including small size and low dosage,bring about difficulties in quantitative analysis and differences in ignition capabilities of CA chips.The aim of present work is to develop a simplified quantitative analysis method for accurate and safe analysis of components in CA chips to evaluate and investigate the corresponding ignition ability.In this work,Cu(N_(3))2 and CuN_(3)components in CA chips were separated through dissolution and distillation by utilizing the difference in solubility and corresponding content was obtained by measuring N_(3)-concentration through spectrophotometry.The spectrophotometry method was optimized by studying influencing factors and the recovery rate of different separation methods was studied,ensuring the accuracy and reproducibility of test results.The optimized method is linear in range from 1.0-25.0 mg/L,with a correlation coefficient R^(2)=0.9998,which meets the requirements of CA chips with a milligram-level content test.Compared with the existing ICP method,component analysis results of CA chips obtained by spectrophotometry are closer to real component content in samples and have satisfactory accuracy.Moreover,as its application in miniaturized explosive systems,the ignition ability of CA chips with different component contents for direct ink writing CL-20 and the corresponding mechanism was studied.This study provided a basis and idea for the design and performance evaluation of CA chips in miniaturized explosive systems.