In this article,we present a theoretical study on the sub-bandgap refractive indexes and optical properties of Sidopedβ-Ga_(2)O_(3) thin films based on newly developed models.The measured sub-bandgap refractive index...In this article,we present a theoretical study on the sub-bandgap refractive indexes and optical properties of Sidopedβ-Ga_(2)O_(3) thin films based on newly developed models.The measured sub-bandgap refractive indexes ofβ-Ga_(2)O_(3) thin film are explained well with the new model,leading to the determination of an explicit analytical dispersion of refractive indexes for photon energy below an effective optical bandgap energy of 4.952 eV for theβ-Ga_(2)O_(3) thin film.Then,the oscillatory structures in long wavelength regions in experimental transmission spectra of Si-dopedβ-Ga_(2)O_(3) thin films with different Si doping concentrations are quantitively interpreted utilizing the determined sub-bandgap refractive index dispersion.Meanwhile,effective optical bandgap values of Si-dopedβ-Ga_(2)O_(3) thin films are further determined and are found to decrease with increasing the Si doping concentration as expectedly.In addition,the sub-bandgap absorption coefficients of Si-dopedβ-Ga_(2)O_(3) thin film are calculated under the frame of the Franz–Keldysh mechanism due to the electric field effect of ionized Si impurities.The theoretical absorption coefficients agree with the available experimental data.These key parameters obtained in the present study may enrich the present understanding of the sub-bandgap refractive indexes and optical properties of impurity-dopedβ-Ga_(2)O_(3) thin films.展开更多
The growth of wind energy penetration level in distribution system raises the concern about its impact on the operation of the power system, especially voltage stability and power loss. Among the major concerns, this ...The growth of wind energy penetration level in distribution system raises the concern about its impact on the operation of the power system, especially voltage stability and power loss. Among the major concerns, this paper studied the impact of connecting wind Turbine (WT) in radial distribution system with different penetration levels and different power factor (lead and lag) on power system voltage stability and power loss reduction. Load flow calculation was carried out using forward-backward sweep method. The analysis proceeds on 9- and 33-bus radial distribution systems. Results show that voltage stability enhancement and power loss reduction should be considered as WT installation objective.展开更多
Two common problems for a typical Power distribution system are voltage collapse & instability. Challenge is to identify the vulnerable nodes and apply the effective corrective actions. This paper presents a proba...Two common problems for a typical Power distribution system are voltage collapse & instability. Challenge is to identify the vulnerable nodes and apply the effective corrective actions. This paper presents a probabilistic fuzzy approach to assess the node status and proposes feeder reconfiguration as a method to address the same. Feeder reconfiguration is altering the topological structures of distribution feeders by changing the open/closed states of the sectionalizing and ties switches. The solution is converge using a probabilistic fuzzy modeled solution, which defines the nodal vulnerability index (VI) as a function of node voltage and node voltage stability index and predicts nodes critical to voltage collapse. The information is further used to plan best combination of feeders from each loop in distribution system to be switched out such that the resulting configuration gives the optimal performance i.e. best voltage profile and minimal kW losses. The proposed method is tested on established radial distribution system and results are presented.展开更多
基金This study was financially supported by the National Natural Science Foundation of China(No.12074324)the Shenzhen Municipal Science and Technology Innovation Council(No.JCJY20180508163404043).
文摘In this article,we present a theoretical study on the sub-bandgap refractive indexes and optical properties of Sidopedβ-Ga_(2)O_(3) thin films based on newly developed models.The measured sub-bandgap refractive indexes ofβ-Ga_(2)O_(3) thin film are explained well with the new model,leading to the determination of an explicit analytical dispersion of refractive indexes for photon energy below an effective optical bandgap energy of 4.952 eV for theβ-Ga_(2)O_(3) thin film.Then,the oscillatory structures in long wavelength regions in experimental transmission spectra of Si-dopedβ-Ga_(2)O_(3) thin films with different Si doping concentrations are quantitively interpreted utilizing the determined sub-bandgap refractive index dispersion.Meanwhile,effective optical bandgap values of Si-dopedβ-Ga_(2)O_(3) thin films are further determined and are found to decrease with increasing the Si doping concentration as expectedly.In addition,the sub-bandgap absorption coefficients of Si-dopedβ-Ga_(2)O_(3) thin film are calculated under the frame of the Franz–Keldysh mechanism due to the electric field effect of ionized Si impurities.The theoretical absorption coefficients agree with the available experimental data.These key parameters obtained in the present study may enrich the present understanding of the sub-bandgap refractive indexes and optical properties of impurity-dopedβ-Ga_(2)O_(3) thin films.
文摘The growth of wind energy penetration level in distribution system raises the concern about its impact on the operation of the power system, especially voltage stability and power loss. Among the major concerns, this paper studied the impact of connecting wind Turbine (WT) in radial distribution system with different penetration levels and different power factor (lead and lag) on power system voltage stability and power loss reduction. Load flow calculation was carried out using forward-backward sweep method. The analysis proceeds on 9- and 33-bus radial distribution systems. Results show that voltage stability enhancement and power loss reduction should be considered as WT installation objective.
文摘Two common problems for a typical Power distribution system are voltage collapse & instability. Challenge is to identify the vulnerable nodes and apply the effective corrective actions. This paper presents a probabilistic fuzzy approach to assess the node status and proposes feeder reconfiguration as a method to address the same. Feeder reconfiguration is altering the topological structures of distribution feeders by changing the open/closed states of the sectionalizing and ties switches. The solution is converge using a probabilistic fuzzy modeled solution, which defines the nodal vulnerability index (VI) as a function of node voltage and node voltage stability index and predicts nodes critical to voltage collapse. The information is further used to plan best combination of feeders from each loop in distribution system to be switched out such that the resulting configuration gives the optimal performance i.e. best voltage profile and minimal kW losses. The proposed method is tested on established radial distribution system and results are presented.