期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Hepatic MR imaging using IDEAL-IQ sequence:Will Gd-EOB-DTPA interfere with reproductivity of fat fraction quantification?
1
作者 Yuan Tian Peng-Fei Liu +2 位作者 Jia-Yu Li Ya-Nan Li Peng Sun 《World Journal of Clinical Cases》 SCIE 2023年第25期5887-5896,共10页
BACKGROUND Iterative decomposition of water and fat with echo asymmetry and least squares estimation quantification sequence(IDEAL-IQ)is based on chemical shift-based water and fat separation technique to get proton d... BACKGROUND Iterative decomposition of water and fat with echo asymmetry and least squares estimation quantification sequence(IDEAL-IQ)is based on chemical shift-based water and fat separation technique to get proton density fat fraction.Multiple studies have shown that using IDEAL-IQ to test the stability and repeatability of liver fat is acceptable and has high accuracy.AIM To explore whether Gadoxetate Disodium(Gd-EOB-DTPA)interferes with the measurement of the hepatic fat content quantified with the IDEAL-IQ and to evaluate the robustness of this technique.METHODS IDEAL-IQ was used to quantify the liver fat content at 3.0T in 65 patients injected with Gd-EOB-DTPA contrast.After injection,IDEAL-IQ was estimated four times,and the fat fraction(FF)and R2* were measured at the following time points:Precontrast,between the portal phase(70 s)and the late phase(180 s),the delayed phase(5 min)and the hepatobiliary phase(20 min).One-way repeated-measures analysis was conducted to evaluate the difference in the FFs between the four time points.Bland-Altman plots were adopted to assess the FF changes before and after injection of the contrast agent.P<0.05 was considered statistically significant.RESULTS The assessment of the FF at the four time points in the liver,spleen and spine showed no significant differences,and the measurements of hepatic FF yielded good consistency between T1 and T2[95%confidence interval:-0.6768%,0.6658%],T1 and T3(-0.3900%,0.3178%),and T1 and T4(-0.3750%,0.2825%).R2* of the liver,spleen and spine increased significantly after injection(P<0.0001).CONCLUSION Using the IDEAL-IQ sequence to measure the FF,we can obtain results that will not be affected by Gd-EOB-DTPA.The high reproducibility of the IDEAL-IQ sequence makes it available in the scanning interval to save time during multiphase examinations. 展开更多
关键词 Gadoxetate Disodium Iterative decomposition of water and fat with echo asymmetry and least squares estimation quantification sequence Fat fraction Enhanced-Magnetic resonance imaging R2*
下载PDF
More on Convering Squares with Squares
2
作者 徐常青 丁仁 《Journal of Mathematical Research and Exposition》 CSCD 北大核心 2004年第1期70-72,共3页
This paper improves some lower bounds of a function f(x) introduced in the problem of covering squares with squares.
关键词 COVERING squareS sequence of closed squares.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部