期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Investigations of Thallium(Ⅰ) Underpotential Deposition on the Silver Rotating Disk Electrode and Its Analytical Application
1
作者 WANG Chun ming ZHU Li 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2001年第1期102-107,共6页
The cyclic voltammetry(CV) and the square wave technique were used for the investigations of thallium(Ⅰ) underpotential deposition(UPD) on the silver electrode. A solution of 10 \{mmol/L\} HClO 4+10 mmol/L NaCl was s... The cyclic voltammetry(CV) and the square wave technique were used for the investigations of thallium(Ⅰ) underpotential deposition(UPD) on the silver electrode. A solution of 10 \{mmol/L\} HClO 4+10 mmol/L NaCl was selected as the supporting electrolyte. The calibration plots for Tl(Ⅰ) concentration in the range of 2×10 -9 -1×10 -7 mol/L were obtained. The detection limit was 5×10 -10 mol/L. For the solutions of 4 0×10 -9 mol/L thallium added before the urine sample pretreatment procedure, the average recovery was 105 6% with a relative standard deviation(RSD) of 15 5%. 展开更多
关键词 Thallium(Ⅰ) Underpotential deposition Silver rotating disk electrode Cyclic voltammetry square wave anodic stripping voltammetry
下载PDF
PSO-SVM applied to SWASV studies for accurate detection of Cd(II)based on disposable electrode 被引量:1
2
作者 Zhao Guo Wang Hui +1 位作者 Yin Yuan Liu Gang 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2017年第5期251-261,共11页
Square wave anodic stripping voltammetry(SWASV)is an effective method for the detection of Cd(II),but the presence of Pb(II)usually has some potential and negative interference on the SWASV detection of Cd(II).In this... Square wave anodic stripping voltammetry(SWASV)is an effective method for the detection of Cd(II),but the presence of Pb(II)usually has some potential and negative interference on the SWASV detection of Cd(II).In this paper,a novel method was proposed to predict the concentration of Cd(II)in the presence of Pb(II)based on the combination of chemically modified electrode(CME),machine learning algorithms(MLA)and SWASV.A Bi film/ionic liquid/screen-printed electrode(Bi/IL/SPE)was prepared and used for the sensitive detection of trace Cd(II).The parameters affecting the stripping currents were investigated and optimized.The morphologies and electrochemical properties of the modified electrode were characterized by scanning electron microscopy(SEM)and SWASV.The measured SWASV spectrograms obtained at different concentrations were used to build the mathematical models for the prediction of Cd(II),which taking the combined effect of Cd(II)and Pb(II)into consideration on the SWASV detection of Cd(II),and to establish a nonlinear relationship between the stripping currents of Pb(II)and Cd(II)and the concentration of Cd(II).The proposed mathematical models rely on an improved particle swarm optimization-support vector machine(PSO-SVM)to assess the concentration of Cd(II)in the presence of Pb(II)in a wide range of concentrations.The experimental results suggest that this method is suitable to fulfill the goal of Cd(II)detection in the presence of Pb(II)(correlation coefficient,mean absolute error and root mean square error were 0.998,1.63 and 1.68,respectively).Finally,the proposed method was applied to predict the trace Cd(II)in soil samples with satisfactory results. 展开更多
关键词 square wave anodic stripping voltammetry(SWASV) particle swarm support vector machine screen-printed electrode heavy metals Cd detection soil pollution
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部