By using speetrally stable targets, the empirical line (EL) method was tested to correct the multispectral IKONOS imagery acquired over Putuo Mountain, Zhejiang, China. A series of calibration targets, which were sp...By using speetrally stable targets, the empirical line (EL) method was tested to correct the multispectral IKONOS imagery acquired over Putuo Mountain, Zhejiang, China. A series of calibration targets, which were spectrally stable over time, were selected to establish the linear predicted equation. Subsequently, a series of spectrally stable validation targets were selected to assess the accuracy of the equations. And, validation targets, which were speetrally unstable over time, were used to test the feasibility of using the EL method to calibrate the archival remotely sensed data. Ground reflectance measurements for each target were made using an ASD FieldSpec spectroradiometer. A Trimble GeoXTTM GPS unit with sub-meter accuracy was used to estimate the target position accurately. Linear regression equations for four tKONOS bands were derived. The coefficients of determination for the blue, green, and red bands were all greater than 0.9800 and it was 0.9697 for the near infrared band. It was concluded that reasonable results could be obtained by using speetrally stable targets.展开更多
基金Project supported by the National Natural Science Foundation of China (No.40171065)the National High Technology Research and Development Program of China (Nos.2002AA130010-2-7 and 2003AA131020-04-06).
文摘By using speetrally stable targets, the empirical line (EL) method was tested to correct the multispectral IKONOS imagery acquired over Putuo Mountain, Zhejiang, China. A series of calibration targets, which were spectrally stable over time, were selected to establish the linear predicted equation. Subsequently, a series of spectrally stable validation targets were selected to assess the accuracy of the equations. And, validation targets, which were speetrally unstable over time, were used to test the feasibility of using the EL method to calibrate the archival remotely sensed data. Ground reflectance measurements for each target were made using an ASD FieldSpec spectroradiometer. A Trimble GeoXTTM GPS unit with sub-meter accuracy was used to estimate the target position accurately. Linear regression equations for four tKONOS bands were derived. The coefficients of determination for the blue, green, and red bands were all greater than 0.9800 and it was 0.9697 for the near infrared band. It was concluded that reasonable results could be obtained by using speetrally stable targets.