Durability zonation standard (DZS) is proposed to provide useful parameters for durable concrete structure design. It deals not only with the influence of environment on structures, but also with types, functions an...Durability zonation standard (DZS) is proposed to provide useful parameters for durable concrete structure design. It deals not only with the influence of environment on structures, but also with types, functions and importance of structures based on the theory of life cycle cost(LCC). First, the basic concept of DZS for concrete structure design is defined. Then the basic principles for DZS are established. The factors for zonation according to natural environmental conditions and structural importance are identified. The usefulness of DZS by citing a real application for concrete highway bridges in Zhejiang Province is demonstrated. Finally, durability regulations are provided accordingly to zonation.展开更多
This article describes an analysis of the energy and economic impacts of possible energy efficiency standards for room air conditioners on both U.S. consumers and the nation as a whole. We used two metrics to determin...This article describes an analysis of the energy and economic impacts of possible energy efficiency standards for room air conditioners on both U.S. consumers and the nation as a whole. We used two metrics to determine the effect of standards on a representative sample of U.S. consumers: life-cycle cost change and payback period. For the national impact analysis, we evaluated national energy savings attributable to each potential standard, the monetary value of the energy savings to consumers of room air conditioners, the increased total installed costs because of standards, and the net present value of the difference between the value of energy savings and increased total installed costs. Our analysis indicates that standards for room air conditioners at efficiency level 3, which is 17% more efficient than today’s typical unit in the case of room air conditioners less than 6000 Btu/h with louvers and 12% more efficient in the case of room air conditioners 8000 - 13,999 Btu/h with louvers, would save close to one quad of energy over 30 years and have a net present value of consumer benefit of between ?$0.14 billion and $1.82 billion, depending on the discount rate. In addition, such standards would reduce carbon dioxide emissions and NOx emissions.展开更多
Carbon emissions from buildings account for approximately half of China’s total social carbon emissions.Focusing only on the carbon emissions of building operation tends to neglect the carbon emissions of other relat...Carbon emissions from buildings account for approximately half of China’s total social carbon emissions.Focusing only on the carbon emissions of building operation tends to neglect the carbon emissions of other related parts of the building sector,thus slowing down the progress of carbon peaking in the building sector.By applying life-cycle analysis to calculate carbon emissions throughout the building’s life cycle,the performance of carbon emissions at each stage of building materials,construction,operation and end-of-life demolition can be identified,so that carbon reduction strategies in building design can be selected..This paper constructed a method for calculating the carbon emissions of green buildings in whole-building life cycle,and conducted a summary analysis of the carbon emissions of 33 projects that were awarded green building certification.The study found that the Chinese Assessment Standard for Green Buildings has a significant effect on reducing the carbon emissions of buildings in whole-building life cycle.Compared with the current average operational carbon emissions of buildings in China,the carbon intensity of green public buildings is 41.43%lower under this standard and the carbon intensity of green residential buildings is 13.99%lower.A carbon correlation analysis of the provisions of the current Chinese Assessment Standard for Green Buildings was conducted,comparing the changes in the carbon intensity of buildings before and after the revision of the standards.The study concluded that the new version of the standards has a greater impact on public buildings than residential buildings,the requirement of carbon emission reduction in the production stage of building materials is strengthened in terms of carbon emission during the whole-building life cycle.This study addresses the current problem of unclear carbon emission reduction effect of green buildings.展开更多
IEEE 1012 [1] describes the SDLC phase activities for software independent verification and validation (IV & V) for nuclear power plant in truly general and conceptual manner, which requires the upward and/or down...IEEE 1012 [1] describes the SDLC phase activities for software independent verification and validation (IV & V) for nuclear power plant in truly general and conceptual manner, which requires the upward and/or downward tailoring on its interpretation for practical IV & V. It contains crucial and encompassing check points and guidelines to analyze the design integrity, without addressing the formalized and the specific criteria for IV & V activities confirming the technical integrity. It is necessary to list up the inspection viewpoint via interpretation of the standard that is practical review points checking design consistency. For fruitful IV & V of Control Element Driving Mechanism Control System (CEDMCS) software for Yonggwang Nuclear Power Plant unit 3 & 4, the specific viewpoints and approach are necessary based on the guidelines of IEEE 1012 to enhance the system quality by considering the level of implementation of the theoretical and the practical IV & V. Additionally IV & V guideline of IEEE 1012 does not specifically provide the concrete measure considering the system characteristics of CEDMCS. This paper provides the seven (7) characteristic criteria for CEDMCS IV & V, and by applying these viewpoints, the design analysis such as function, performance, interface and exception, backward and forward requirement traceability analysis has been conducted. The requirement, design, implementation, and test phase were only considered for IV & V in this project. This article also provides the translation of code to map theoretical verification and validation into practical verification and validation. This paper emphasizes the necessity of the intensive design inspection and walkthrough for requirement phase to resolve the design faults because the IV & V of early phase of SDLC obviously contributes to find out most of critical design inconsistency. Especially for test phase IV & V, it is strongly recommended to prepare the test plan document which is going to be the basis for the test coverage selection and test strategy. This test plan document should be based on the critical characteristics of function and performance of CEDMCS. Also to guarantee the independency of V & V organization participating in this project, and to acquire the full package of design details for IV & V, the systematic approach and efforts with an aspect of management is highlighted among the participants.展开更多
基金The Key Project of National Natural Science Foun-dation of China (No50538070)
文摘Durability zonation standard (DZS) is proposed to provide useful parameters for durable concrete structure design. It deals not only with the influence of environment on structures, but also with types, functions and importance of structures based on the theory of life cycle cost(LCC). First, the basic concept of DZS for concrete structure design is defined. Then the basic principles for DZS are established. The factors for zonation according to natural environmental conditions and structural importance are identified. The usefulness of DZS by citing a real application for concrete highway bridges in Zhejiang Province is demonstrated. Finally, durability regulations are provided accordingly to zonation.
文摘This article describes an analysis of the energy and economic impacts of possible energy efficiency standards for room air conditioners on both U.S. consumers and the nation as a whole. We used two metrics to determine the effect of standards on a representative sample of U.S. consumers: life-cycle cost change and payback period. For the national impact analysis, we evaluated national energy savings attributable to each potential standard, the monetary value of the energy savings to consumers of room air conditioners, the increased total installed costs because of standards, and the net present value of the difference between the value of energy savings and increased total installed costs. Our analysis indicates that standards for room air conditioners at efficiency level 3, which is 17% more efficient than today’s typical unit in the case of room air conditioners less than 6000 Btu/h with louvers and 12% more efficient in the case of room air conditioners 8000 - 13,999 Btu/h with louvers, would save close to one quad of energy over 30 years and have a net present value of consumer benefit of between ?$0.14 billion and $1.82 billion, depending on the discount rate. In addition, such standards would reduce carbon dioxide emissions and NOx emissions.
基金funded by National Key Research and Development Plan of China(Grant No.2020YFE0200300).
文摘Carbon emissions from buildings account for approximately half of China’s total social carbon emissions.Focusing only on the carbon emissions of building operation tends to neglect the carbon emissions of other related parts of the building sector,thus slowing down the progress of carbon peaking in the building sector.By applying life-cycle analysis to calculate carbon emissions throughout the building’s life cycle,the performance of carbon emissions at each stage of building materials,construction,operation and end-of-life demolition can be identified,so that carbon reduction strategies in building design can be selected..This paper constructed a method for calculating the carbon emissions of green buildings in whole-building life cycle,and conducted a summary analysis of the carbon emissions of 33 projects that were awarded green building certification.The study found that the Chinese Assessment Standard for Green Buildings has a significant effect on reducing the carbon emissions of buildings in whole-building life cycle.Compared with the current average operational carbon emissions of buildings in China,the carbon intensity of green public buildings is 41.43%lower under this standard and the carbon intensity of green residential buildings is 13.99%lower.A carbon correlation analysis of the provisions of the current Chinese Assessment Standard for Green Buildings was conducted,comparing the changes in the carbon intensity of buildings before and after the revision of the standards.The study concluded that the new version of the standards has a greater impact on public buildings than residential buildings,the requirement of carbon emission reduction in the production stage of building materials is strengthened in terms of carbon emission during the whole-building life cycle.This study addresses the current problem of unclear carbon emission reduction effect of green buildings.
文摘IEEE 1012 [1] describes the SDLC phase activities for software independent verification and validation (IV & V) for nuclear power plant in truly general and conceptual manner, which requires the upward and/or downward tailoring on its interpretation for practical IV & V. It contains crucial and encompassing check points and guidelines to analyze the design integrity, without addressing the formalized and the specific criteria for IV & V activities confirming the technical integrity. It is necessary to list up the inspection viewpoint via interpretation of the standard that is practical review points checking design consistency. For fruitful IV & V of Control Element Driving Mechanism Control System (CEDMCS) software for Yonggwang Nuclear Power Plant unit 3 & 4, the specific viewpoints and approach are necessary based on the guidelines of IEEE 1012 to enhance the system quality by considering the level of implementation of the theoretical and the practical IV & V. Additionally IV & V guideline of IEEE 1012 does not specifically provide the concrete measure considering the system characteristics of CEDMCS. This paper provides the seven (7) characteristic criteria for CEDMCS IV & V, and by applying these viewpoints, the design analysis such as function, performance, interface and exception, backward and forward requirement traceability analysis has been conducted. The requirement, design, implementation, and test phase were only considered for IV & V in this project. This article also provides the translation of code to map theoretical verification and validation into practical verification and validation. This paper emphasizes the necessity of the intensive design inspection and walkthrough for requirement phase to resolve the design faults because the IV & V of early phase of SDLC obviously contributes to find out most of critical design inconsistency. Especially for test phase IV & V, it is strongly recommended to prepare the test plan document which is going to be the basis for the test coverage selection and test strategy. This test plan document should be based on the critical characteristics of function and performance of CEDMCS. Also to guarantee the independency of V & V organization participating in this project, and to acquire the full package of design details for IV & V, the systematic approach and efforts with an aspect of management is highlighted among the participants.