Assessment standard for green store building of national standard has been compiled. The index has been given by experts' subjective assignment based on experience. Analytic hierarchy process has been used,making ...Assessment standard for green store building of national standard has been compiled. The index has been given by experts' subjective assignment based on experience. Analytic hierarchy process has been used,making questionnaires of experts,using pairwise comparison and calculating the weight of each index. The weight of index in assessment would not only make quantitative evaluation on the whole situation of green store buildings,but also provide the foundation for compilation and revision.展开更多
The utilization of waste concrete as a raw material for recycled concrete in the domain of prefabricated components is garnering greater interest.This paper delineates and examines the concept,categorization,methodolo...The utilization of waste concrete as a raw material for recycled concrete in the domain of prefabricated components is garnering greater interest.This paper delineates and examines the concept,categorization,methodologies of preparation,applicable sectors,and evaluative metrics of recycled concrete technology,highlighting its prospective benefits.Nonetheless,for the successful integration of recycled concrete technology into prefabricated component applications,it is imperative to systematically enhance its physical,mechanical,and attributes,as well as its environmental efficacy.Moreover,to foster the continued advancement of recycled concrete technology,innovative initiatives,standardization,educational programs,demonstration projects,and collaborative efforts are crucial to promote broader adoption and realize improved outcomes within the realm of prefabricated components.In conclusion,recycled concrete technology is poised to play a pivotal role in prefabricated construction,offering robust support for propelling the construction industry towards a sustainable future.展开更多
One of the challenges in construction of nearly and net ZEBs is how to truly achieve the nearly and net energy goals after building occupancy.Traditional building design standards and practices are mostly based on des...One of the challenges in construction of nearly and net ZEBs is how to truly achieve the nearly and net energy goals after building occupancy.Traditional building design standards and practices are mostly based on design performance evaluation,but practices show that many designed nearly/net ZEBs failed to achieve the energy goals after building occupancy.To facilitate the practical achievement of nearly and net ZEBs,recently most of the newly-released ZEB design standards have turned to post-occupancy performance evaluation,posing great challenges to nearly and net ZEB design.However,the detailed challenges have not be comprehensively investigated,and effective optimal design methods which can facilitate the achievement of nearly and net ZEBs under these standards are still absent.In this study,new challenges of nearly and net ZEB design under the post-occupancy performance-based design standards are fully investigated,and a risk-benefit based optimal design method is proposed to facilitate the achievement of nearly and net ZEBs under these standards.The newly-released ZEB standard in China is taken as an example to investigate the challenges and test the proposed method.Results show that nearly and net ZEBs designed using conventional design method have high risk in achieving energy goals under these standards due to high risk in satisfying the requirement regarding non-renewable primary energy consumption after building occupancy.The proposed design method is effective to facilitate achieving energy goals under these standards based on the risk that decision-makers would like to take.展开更多
基金Sponsored by the National Project of Scientific and Technical Supporting Programs of Ministry of Science & Technology of China(Grant No.2012BAJ10B02)
文摘Assessment standard for green store building of national standard has been compiled. The index has been given by experts' subjective assignment based on experience. Analytic hierarchy process has been used,making questionnaires of experts,using pairwise comparison and calculating the weight of each index. The weight of index in assessment would not only make quantitative evaluation on the whole situation of green store buildings,but also provide the foundation for compilation and revision.
基金Supported by the Science and Technology Research Program of Chongqing Municipal Education Commission(Grant No.KJQN202204305,and No.KJQN202305501).
文摘The utilization of waste concrete as a raw material for recycled concrete in the domain of prefabricated components is garnering greater interest.This paper delineates and examines the concept,categorization,methodologies of preparation,applicable sectors,and evaluative metrics of recycled concrete technology,highlighting its prospective benefits.Nonetheless,for the successful integration of recycled concrete technology into prefabricated component applications,it is imperative to systematically enhance its physical,mechanical,and attributes,as well as its environmental efficacy.Moreover,to foster the continued advancement of recycled concrete technology,innovative initiatives,standardization,educational programs,demonstration projects,and collaborative efforts are crucial to promote broader adoption and realize improved outcomes within the realm of prefabricated components.In conclusion,recycled concrete technology is poised to play a pivotal role in prefabricated construction,offering robust support for propelling the construction industry towards a sustainable future.
基金supported by a grant(152079/18E)from the Research Grant Council(RGC)of the Hong Kong SAR,China.
文摘One of the challenges in construction of nearly and net ZEBs is how to truly achieve the nearly and net energy goals after building occupancy.Traditional building design standards and practices are mostly based on design performance evaluation,but practices show that many designed nearly/net ZEBs failed to achieve the energy goals after building occupancy.To facilitate the practical achievement of nearly and net ZEBs,recently most of the newly-released ZEB design standards have turned to post-occupancy performance evaluation,posing great challenges to nearly and net ZEB design.However,the detailed challenges have not be comprehensively investigated,and effective optimal design methods which can facilitate the achievement of nearly and net ZEBs under these standards are still absent.In this study,new challenges of nearly and net ZEB design under the post-occupancy performance-based design standards are fully investigated,and a risk-benefit based optimal design method is proposed to facilitate the achievement of nearly and net ZEBs under these standards.The newly-released ZEB standard in China is taken as an example to investigate the challenges and test the proposed method.Results show that nearly and net ZEBs designed using conventional design method have high risk in achieving energy goals under these standards due to high risk in satisfying the requirement regarding non-renewable primary energy consumption after building occupancy.The proposed design method is effective to facilitate achieving energy goals under these standards based on the risk that decision-makers would like to take.