This paper presents the design of an experimental battlefield dynamic scanning and staring imaging system based on a fast steering mirror(FSM), which is capable of real-time monitoring of hot targets and wide-area rec...This paper presents the design of an experimental battlefield dynamic scanning and staring imaging system based on a fast steering mirror(FSM), which is capable of real-time monitoring of hot targets and wide-area reconnaissance of hot regions. First,the working principle and working sequence of the FSM are briefly analyzed. The mathematical model of the FSM system is built by modeling its dynamic and electrical properties, and the rationality of the model is validated by means of model identification. Second,the influence of external sources of disturbance such as the carrier and moment on the control precision of the FSM is effectively suppressed by the jointly controlling of proportional integral(PI)and disturbance observer(DOB), thus realizing a high precision and strong robustness control of the FSM system. Then, this paper designs an experimental prototype and introduces a special optical structure to enable the infrared camera to share the FSM with the visible light camera. Finally, the influence of the velocity difference between the mirror of the FSM and the rotating platform on the imaging quality of the system is experimentally analyzed by using the image sharpness evaluation method based on point sharpness. A good dynamic scanning and staring imaging result is achieved when the velocity of these two components correspond.展开更多
The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with are...The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with areas of steep dose gradients,inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements.This may introduce significant errors,particularly in proton spot scanning radiotherapy.In this study,by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method,a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution.Meanwhile,the similarity between the measured original data and the downsampled logfilebased reconstructed dose is regarded as the confidence of the reformatted dose distribution.Furthermore,we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements.The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements.The reformatted dose distributions generally yield a confidence exceeding 95%.展开更多
Using a scanning electron microscope (SEM) in the back-scattered electron (BSE) mode the composition of multi-element specimens may be determined based on the strong dependence of emission coefficient η on the averag...Using a scanning electron microscope (SEM) in the back-scattered electron (BSE) mode the composition of multi-element specimens may be determined based on the strong dependence of emission coefficient η on the average atomic number of elements Z. The output video signal of the usual BSE detectors is produced from their sensors, and the larger proportion of high-energy electrons with modified spectrum is added. Since η = is/ip (is and ip currents of specimen and probe), better accuracy must be achieved by direct measurements those currents on the specimen surface. Here, an experimental model of a current detector for a presented specimen is described. The cage is mounted on the carousel of the moving specimen stage. The input of the preamplifier is connected to the specimen holder in the form of a disk, the diameter of which is 12 mm. When the probe along its surface scanned, the input potential begins to pulsate with a negative polarity. The output of this preamplifier is connected to a small light-emitting diode, which creates intensity-modulated radiation in the chamber. Thus created the light video signal will be picked up by the photomultiplier of the E-T detector. The modes of true SE and BSE are set by applying tens bias volts of various polarities to the specimens or the cage itself.展开更多
The properties of a Lanthanum bromide(LaBr3)detector and its response functions were investigated via experiments and simulations in this paper.The LaBr3detector had good relative energy resolution and higher efficien...The properties of a Lanthanum bromide(LaBr3)detector and its response functions were investigated via experiments and simulations in this paper.The LaBr3detector had good relative energy resolution and higher efficiency than a high-purity germanium detector.Monte Carlo and other numerical methods were used to calculate the efficiencies of a LaBr3detector with a square collimation window.A model of the numerical method was established based on a pure geometric model that was consistent with the experimental situation.The results showed that the detector response functions calculated by these methods were in great agreement with experimental results.展开更多
This paper explores an alternative to the standard method of studying the responsivities (the input-output gain) and other behaviours of detectors at low electron energy. The research does not aim to compare the res...This paper explores an alternative to the standard method of studying the responsivities (the input-output gain) and other behaviours of detectors at low electron energy. The research does not aim to compare the results of differently doped n+p detectors; its purpose is to provide an alternative characterization method (using scanning electron microscopy) to those used in previous studies on the responsivity ofn+p doped detectors as a function of the electron radiation energy and other interface oarameters.展开更多
基金supported by the National Defense Pre-research Project of China during the 12th Five-year Plan Period(4040570201)Innovation Project of Military Academy(ZYX14060014)
文摘This paper presents the design of an experimental battlefield dynamic scanning and staring imaging system based on a fast steering mirror(FSM), which is capable of real-time monitoring of hot targets and wide-area reconnaissance of hot regions. First,the working principle and working sequence of the FSM are briefly analyzed. The mathematical model of the FSM system is built by modeling its dynamic and electrical properties, and the rationality of the model is validated by means of model identification. Second,the influence of external sources of disturbance such as the carrier and moment on the control precision of the FSM is effectively suppressed by the jointly controlling of proportional integral(PI)and disturbance observer(DOB), thus realizing a high precision and strong robustness control of the FSM system. Then, this paper designs an experimental prototype and introduces a special optical structure to enable the infrared camera to share the FSM with the visible light camera. Finally, the influence of the velocity difference between the mirror of the FSM and the rotating platform on the imaging quality of the system is experimentally analyzed by using the image sharpness evaluation method based on point sharpness. A good dynamic scanning and staring imaging result is achieved when the velocity of these two components correspond.
文摘The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with areas of steep dose gradients,inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements.This may introduce significant errors,particularly in proton spot scanning radiotherapy.In this study,by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method,a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution.Meanwhile,the similarity between the measured original data and the downsampled logfilebased reconstructed dose is regarded as the confidence of the reformatted dose distribution.Furthermore,we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements.The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements.The reformatted dose distributions generally yield a confidence exceeding 95%.
文摘Using a scanning electron microscope (SEM) in the back-scattered electron (BSE) mode the composition of multi-element specimens may be determined based on the strong dependence of emission coefficient η on the average atomic number of elements Z. The output video signal of the usual BSE detectors is produced from their sensors, and the larger proportion of high-energy electrons with modified spectrum is added. Since η = is/ip (is and ip currents of specimen and probe), better accuracy must be achieved by direct measurements those currents on the specimen surface. Here, an experimental model of a current detector for a presented specimen is described. The cage is mounted on the carousel of the moving specimen stage. The input of the preamplifier is connected to the specimen holder in the form of a disk, the diameter of which is 12 mm. When the probe along its surface scanned, the input potential begins to pulsate with a negative polarity. The output of this preamplifier is connected to a small light-emitting diode, which creates intensity-modulated radiation in the chamber. Thus created the light video signal will be picked up by the photomultiplier of the E-T detector. The modes of true SE and BSE are set by applying tens bias volts of various polarities to the specimens or the cage itself.
基金Supported by Research Fund for the Doctoral Program of Higher Education of China(No.20120073130009)National Natural Science Foundation of China(No.11175118)Research and innovation project of Shanghai Municipal Education Commission(No.12ZZ022)
文摘The properties of a Lanthanum bromide(LaBr3)detector and its response functions were investigated via experiments and simulations in this paper.The LaBr3detector had good relative energy resolution and higher efficiency than a high-purity germanium detector.Monte Carlo and other numerical methods were used to calculate the efficiencies of a LaBr3detector with a square collimation window.A model of the numerical method was established based on a pure geometric model that was consistent with the experimental situation.The results showed that the detector response functions calculated by these methods were in great agreement with experimental results.
文摘This paper explores an alternative to the standard method of studying the responsivities (the input-output gain) and other behaviours of detectors at low electron energy. The research does not aim to compare the results of differently doped n+p detectors; its purpose is to provide an alternative characterization method (using scanning electron microscopy) to those used in previous studies on the responsivity ofn+p doped detectors as a function of the electron radiation energy and other interface oarameters.