期刊文献+
共找到2,086篇文章
< 1 2 105 >
每页显示 20 50 100
Numerical study of plasmas start-up by electron cyclotron waves in NCST spherical tokamak and CN-H1 stellarator
1
作者 刘亿卓行 郑平卫 +4 位作者 龚学余 尹岚 陈小昌 钟翊君 杨文军 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期12-22,共11页
According to the physics of tokamak start-up,this study constructs a zero-dimensional(0D)model applicable to electron cyclotron(EC)wave assisted start-up in NCST spherical torus(spherical tokamak)and CN-H1 stellarator... According to the physics of tokamak start-up,this study constructs a zero-dimensional(0D)model applicable to electron cyclotron(EC)wave assisted start-up in NCST spherical torus(spherical tokamak)and CN-H1 stellarators.Using the constructed 0D model,the results obtained in this study under the same conditions are compared and validated against reference results for pure hydrogen plasma start-up in tokamak.The results are in good agreement,especially regarding electron temperature,ion temperature and plasma current.In the presence of finite Ohmic electric field in the spherical tokamak,a study on the EC wave assisted start-up of the NCST plasma at frequency of 28 GHz is conducted.The impact of the vertical magnetic field B_(v)on EC wave assisted start-up,the relationship between EC wave injection power P_(inj),Ohmic electric field E,and initial hydrogen atom density n_(H0)are explored separately.It is found that under conditions of Ohmic electric field lower than ITER(~0.3 V m^(-1)),EC wave can expand the operational space to achieve better plasma parameters.Simulating the process of28 GHz EC wave start-up in the CN-H1 stellarator plasma,the plasma current in the zerodimensional model is replaced with the current in the poloidal coil of the stellarator.Plasma startup can be successfully achieved at injection powers in the hundreds of kilowatts range,resulting in electron densities on the order of 10^(17)-10^(18)m^(-3). 展开更多
关键词 spherical torus STELLARATOR electron cyclotron wave start-up 0D model
下载PDF
Experimental Analysis of Radial Centrifugal Pump Shutdown
2
作者 Xiao Sun Jiangbo Tong +4 位作者 Yuliang Zhang Haibing Cai Wen Zhou Xiaoqi Jia Litao Ou 《Fluid Dynamics & Materials Processing》 EI 2024年第4期725-737,共13页
Centrifugal pumps are widely used in the metallurgy,coal,and building sectors.In order to study the hydraulic characteristics of a closed impeller centrifugal pump during its shutdown in the so-called power frequency ... Centrifugal pumps are widely used in the metallurgy,coal,and building sectors.In order to study the hydraulic characteristics of a closed impeller centrifugal pump during its shutdown in the so-called power frequency and frequency conversion modes,experiments were carried to determine the characteristic evolution of parameters such as speed,inlet and outlet pressure,head,flow rate and shaft power.A quasi-steady-state method was also used to further investigate these transient behaviors.The results show that,compared to the power frequency input,the performance parameter curves for the frequency conversion input are less volatile and smoother.The characteristic time is longer and the response to shutdown is slower.The quasi-steady-state theoretical head-flow curves match the experimental head-flow curves more closely at low flow rates when the frequency conversion input is considered.Moreover,in this case,the similarity law predicts the hydraulic performance more accurately. 展开更多
关键词 Centrifugal pump power frequency frequency conversion shutdown external characteristic experimental study
下载PDF
Simulation Method and Feature Analysis of Shutdown Pressure Evolution During Multi-Cluster Fracturing Stimulation
3
作者 Huaiyin He Longqing Zou +5 位作者 Yanchao Li Yixuan Wang Junxiang Li Huan Wen Bei Chang Lijun Liu 《Energy Engineering》 EI 2024年第1期111-123,共13页
Multistage multi-cluster hydraulic fracturing has enabled the economic exploitation of shale reservoirs,but the interpretation of hydraulic fracture parameters is challenging.The pressure signals after pump shutdown a... Multistage multi-cluster hydraulic fracturing has enabled the economic exploitation of shale reservoirs,but the interpretation of hydraulic fracture parameters is challenging.The pressure signals after pump shutdown are influenced by hydraulic fractures,which can reflect the geometric features of hydraulic fracture.The shutdown pressure can be used to interpret the hydraulic fracture parameters in a real-time and cost-effective manner.In this paper,a mathematical model for shutdown pressure evolution is developed considering the effects of wellbore friction,perforation friction and fluid loss in fractures.An efficient numerical simulation method is established by using the method of characteristics.Based on this method,the impacts of fracture half-length,fracture height,opened cluster and perforation number,and filtration coefficient on the evolution of shutdown pressure are analyzed.The results indicate that a larger fracture half-length may hasten the decay of shutdown pressure,while a larger fracture height can slow down the decay of shutdown pressure.A smaller number of opened clusters and perforations can significantly increase the perforation friction and decrease the overall level of shutdown pressure.A larger filtration coefficient may accelerate the fluid filtration in the fracture and hasten the drop of the shutdown pressure.The simulation method of shutdown pressure,as well as the analysis results,has important implications for the interpretation of hydraulic fracture parameters. 展开更多
关键词 Multistage multi-cluster hydraulic fracturing pump shutdown pressure feature analysis numerical simulation
下载PDF
WINDOWS95使用随笔——中文视窗九五关于DELE、V-FAT、SHUTDOWN的说明
4
作者 曹进 《上海微型计算机》 1997年第7期42-42,共1页
一、怎样删除WINDOWS 95系统 常有电脑爱好者询问:WIN95出故障后,如何将其在DOS下删除?为什么有故障而不能再次进行WIN95的安装呢?或怎样正确进行WIN95的删除呢? 先说说发烧友的一个普遍不良习惯,这就是找到一个新的软件,不管三七二十一... 一、怎样删除WINDOWS 95系统 常有电脑爱好者询问:WIN95出故障后,如何将其在DOS下删除?为什么有故障而不能再次进行WIN95的安装呢?或怎样正确进行WIN95的删除呢? 先说说发烧友的一个普遍不良习惯,这就是找到一个新的软件,不管三七二十一,先装进计算机再说,如果遇到问题,不去查阅操作手册,而是凭着平时的所谓“专业知识功底”删掉再装。 展开更多
关键词 WINDOWS 中文视窗 DELE V-FAT shutdown
全文增补中
Analysis on the Problems in Start-up and Debugging of Two 600 MW Generating Units in Yangzhou No.2 Thermal Power Plant
5
作者 蒯狄正 《Electricity》 2001年第2期11-15,共5页
The problems including excessive flow of attemperating water for boiler, failure of butterfly valve at the outlet of circulating water pump, burnt-out of thyristor for excitation regulator, load variation rate of CCS ... The problems including excessive flow of attemperating water for boiler, failure of butterfly valve at the outlet of circulating water pump, burnt-out of thyristor for excitation regulator, load variation rate of CCS not complying with the contract target, etc. occurred during start-up and debugging of two 600 MW generating units in Yangzhou No.2 Thermal Power Plant. Through analysis on these problems. the remedial measures were put forward, to which can be referred for similar units. 展开更多
关键词 start-up and debugging problems analysis remedial measures 600 MW generating unit
下载PDF
A polyethylene microsphere-coated separator with rapid thermal shutdown function for lithium-ion batteries 被引量:5
6
作者 Chongrong Zhang Hui Li +4 位作者 Shixuan Wang Yuliang Cao Hanxi Yang Xinping Ai Faping Zhong 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2020年第5期33-40,共8页
Thermal runaway is the main factor contributing to the unsafe behaviors of lithium-ion batteries(LIBs)in practical applications.The application of separators for the thermal shutdown has been proven as an effective ap... Thermal runaway is the main factor contributing to the unsafe behaviors of lithium-ion batteries(LIBs)in practical applications.The application of separators for the thermal shutdown has been proven as an effective approach to protecting LIBs from thermal runaway.In this work,we developed a thermal shutdown separator by coating a thin layer of low-density polyethylene microspheres(PM)onto a commercial porous polypropylene(PP)membrane and investigated the thermal response behaviors of the as-prepared PM/PP separator in LIBs.The structural and thermal analysis results revealed that the coated PM layer had a porous structure,which facilitated the occurrence of normal charge-discharge reactions at ambient temperature,although it could melt completely and fuse together within very short time periods:3 s at 110℃and 1 s at 120℃,to block off the pores of the PP substrate,thereby cutting off the ion transportation between the electrodes and interrupting the battery reaction.Consequently,the PM/PP separator exhibits very similar electrochemical performance to that of a conventional separator at ambient temperature.However,it performs a rapid thermal shutdown at an elevated temperature of^110℃,thus controlling the temperature rise and maintaining the cell in a safe status.Due to its synthetic simplicity and low cost,this separator shows promise for possible application in building safe LIBs. 展开更多
关键词 THERMAL shutdown SEPARATOR Safety LITHIUM-ION battery
下载PDF
Start-up of anaerobic ammonia oxidation bioreactor with nitrifying activated sludge 被引量:26
7
作者 ZHENGPing LINFeng-mei +1 位作者 HUBao-lan CHENJian-song 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2004年第1期13-16,共4页
The anaerobic ammonia oxidation(Anammox) bioreactor was successfully started up with the nitrifying activated sludge. After anaerobically operated for 105 d, the bioreactor reached a good performance with removal perc... The anaerobic ammonia oxidation(Anammox) bioreactor was successfully started up with the nitrifying activated sludge. After anaerobically operated for 105 d, the bioreactor reached a good performance with removal percentage of both ammonia and nitrite higher than 95% and volumetric total nitrogen removal as high as 149.55 mmol/(L·d). The soft padding made an important contribution to the high efficiency and stability because it held a large amount of biomass in the bioreactor. 展开更多
关键词 Anammox bioreactor nitrifying activated sludge start-up
下载PDF
A method to refine the start-up scheme of compression and refrigeration systems in ethylene plants via dynamic simulation 被引量:2
8
作者 Shengfu Zhang Yongchen Zhao +2 位作者 Tong Qiu Guang Song Jinsong Zhao 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第8期1007-1012,共6页
Starting the cracking gas compressor and precooling the refrigeration system are keys to start-up of an ethylene plant and accounts for up to 50% of the total start-up time and plant flare emissions. Premature feeding... Starting the cracking gas compressor and precooling the refrigeration system are keys to start-up of an ethylene plant and accounts for up to 50% of the total start-up time and plant flare emissions. Premature feeding of cracking furnaces can be avoided if the cracking gas compressor is started and the refrigeration system is precooled in advance using mixed gas as the start-up working medium(SWM). Start-up scenario with mixed gas as SWM could significantly reduce the emission loss and shorten the precooling time. Research shows that making appropriate start-up scheme is important not only to ensure operational safety and feasibility, but also to reduce energy consumption. In this paper, a method is proposed to select suitable start-up operational parameters of compression and refrigeration system with sufficient safe operating ranges and short precooling time. The complex interrelation among key parameters of start-up is analyzed. It is found that higher energy consumption, especially for super high-pressure steam(SS), can promote operational safety and shorten the precooling time during start-up.Based on steady-state and dynamic simulation, appropriate operating parameter ranges are determined with reasonable SS consumption. A real case study demonstrates that an appropriate start-up scheme will optimize the operation. 展开更多
关键词 start-up ETHYLENE PLANT start-up working MEDIUM MIXED gas RUN Compression system
下载PDF
Reliability Analysis on Repairable System with Dual Input Closed-Loop Feedback Link Considering Shutdown Correlation Based on Goal Oriented Methodology 被引量:3
9
作者 伊枭剑 石坚 +3 位作者 穆慧娜 张瑶 郭少伟 梁启海 《Journal of Donghua University(English Edition)》 EI CAS 2016年第2期314-318,共5页
Goal oriented( GO) methodology is a kind of success oriented system reliability analysis method and has been used widely.The repairable system with dual input closed-loop feedback link( DICLFL) considering shutdown co... Goal oriented( GO) methodology is a kind of success oriented system reliability analysis method and has been used widely.The repairable system with dual input closed-loop feedback link( DICLFL) considering shutdown correlation didn't make reliability analysis accurately based on existing GO methodology. So, a reliability analysis method used to deal with DICLFL considering shutdown correlation is provided based on GO methodology.Firstly, a new operator, which is used to describe DICLFL considering shutdown correlation,whose number is 1,is created and named as Type 9C operator. And then,the formulas of type 9C operator are derived based on Markov process theory. Finally,the new method presented in this paper is adopted to conduct the reliability analysis of an electro-hydraulic servo speed control system. The analysis result is compared with those of Monte Carlo simulation and fault tree analysis( FTA). The comparison results show that this new reliability analysis method based on GO methodology is feasible and meaningful for reliability analysis of repairable systems with DICLFL considering shutdown correlation.Meantime,it will be useful for more other applications. 展开更多
关键词 shutdown correlation goal oriented(GO) methodology GO operator dual input closed-loop feedback link(DICLFL) reliability analysis
下载PDF
Neutronic design investigation of a liquid injection-based second shutdown system for a typical research reactor using MCNPX 被引量:1
10
作者 Ehsan Boustani Mostafa Hassanzadeh 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第3期51-60,共10页
Safety systems, built on state-of-the-art technology, are essential for achieving acceptable levels of plant safety to minimize hazards to the reactor and the general public. The second shutdown system(SSS) as an engi... Safety systems, built on state-of-the-art technology, are essential for achieving acceptable levels of plant safety to minimize hazards to the reactor and the general public. The second shutdown system(SSS) as an engineered safety feature and a part of the reactor protection system(RPS) is a means for rapidly shutting down a nuclear reactor, keeping it in a subcritical state and serving as a backup to the first shutdown system(FSS). In this research, one SSS with two types of optimum chamber designs is proposed that take into account the main current characteristic features of the Tehran research reactor with improvements over earlier designs. They are based on a liquid neutron absorber injection that is preferably different, diverse, and independent from the FSS based on the rod drop mechanism. The major design characteristics of this SSS with two different chambers were investigated using MCNPX 2.6.0 code. The performed calculations showed that the designed SSS is a reliable shutdown system, assuring an appropriate shutdown margin and injection time, with no significant effects on the effective delayed neutron fraction while causing minimal variations to the core structure. Further, the reasonable financial cost and the prolongation of the operation cycle are additional advantages of this design. 展开更多
关键词 TEHRAN research reactor SECOND shutdown system Nuclear safety Design criteria MCNPX code
下载PDF
Dynamic Responses of A Semi-Type Offshore Floating Wind Turbine During Normal State and Emergency Shutdown 被引量:5
11
作者 胡志强 李良 +2 位作者 王晋 胡秋皓 沈马成 《China Ocean Engineering》 SCIE EI CSCD 2016年第1期97-112,共16页
This paper addresses joint wind-wave induced dynamic responses of a semi-type offshore floating wind turbine(OFWT) under normal states and fault event conditions. The analysis in this paper is conducted in time doma... This paper addresses joint wind-wave induced dynamic responses of a semi-type offshore floating wind turbine(OFWT) under normal states and fault event conditions. The analysis in this paper is conducted in time domain, using an aero-hydro-servo-elastic simulation code-FAST. Owing to the unique viscous features of the reference system, the original viscous damping model implemented in FAST is replaced with a quadratic one to gain an accurate capture of viscous effects. Simulation cases involve free-decay motion in still water, steady motions in the presence of regular waves and wind as well as dynamic response in operational sea states with and without wind. Simulations also include the cases for transient responses induced by fast blade pitching after emergency shutdown. The features of platform motions, local structural loads and a typical mooring line tension force under a variety of excitations are obtained and investigated. 展开更多
关键词 offshore floating wind turbine dynamic responses semi-type aerodynamic effects effective RAO emergency shutdown
下载PDF
The start-up of biohydrogen-producing process by bioaugmentation in the EGSB reactor 被引量:5
12
作者 王相晶 Ren Nanqi +1 位作者 Xiang Wensheng Guo Wanqian 《High Technology Letters》 EI CAS 2006年第3期328-332,共5页
Expanded granular sludge bed (EGSB) reactor and bioaugmentation were employed to investigate biohydrogen production with molasses wastewater. The start-up experiments consisted of two stages. In the first stage (0 ... Expanded granular sludge bed (EGSB) reactor and bioaugmentation were employed to investigate biohydrogen production with molasses wastewater. The start-up experiments consisted of two stages. In the first stage (0 - 24d) seeded with activated sludge, the butyric acid type-fermentation formed when the initial expanding rate, organic loading rate (OLR), the initial redox potential (ORP) and hydraulic retention time (HRT) were 10%, 10.0 kg COD/(m^3·d), -215 mV and 6.7 h, respectively. At the beginning of the second stage on day 25, the novel hydrogen-producing fermentative bacterial strain B49 (AF481148 in EMBL) were inoculated into the reactor under the condition of OLR 16. 0 kg COD/(m^3·d), ORP and HRT about - 139 mV and 6.7 h, respectively, and then the reaction system transformed to ethanol-type fermentation gradually with the increase in OLR. When OLR, ORP and HRT were about 94.3 kg COD/(m^3·d), -250 mV and 1.7 h, respectively, the system achieved the maximum hydrogen-producing rate of 282.6 mL H2/L reactor·h and hydrogen percentage of 51% -53% in the biogas. 展开更多
关键词 start-up biohydrogen production BIOAUGMENTATION hydrogen-producing bacterial strain B49 EGSB reactor
下载PDF
The exact solution of Stokes' second problem including start-up process with fractional element 被引量:3
13
作者 Kaixin Hu Keqin Zhu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2009年第5期577-582,共6页
The start-up process of Stokes' second problem of a viscoelastic material with fractional element is studied. The fluid above an infinite flat plane is set in motion by a sudden acceleration of the plate to steady os... The start-up process of Stokes' second problem of a viscoelastic material with fractional element is studied. The fluid above an infinite flat plane is set in motion by a sudden acceleration of the plate to steady oscillation. Exact solutions are obtained by using Laplace transform and Fourier transform. It is found that the relationship between the first peak value and the one of equal-amplitude oscillations depends on the distance from the plate. The amplitude decreases for increasing frequency and increasing distance. 展开更多
关键词 Stokes' second problem start-up process Fractional element Laplace transform Fourier transform
下载PDF
Start-up and Performance of a Novel Reactor----Jet Biogas Inter-loop Anaerobic Fluidized Bed 被引量:2
14
作者 邓志毅 韦朝海 周秀峰 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第1期143-150,共8页
A novel anaerobic reactor, jet biogas inter-loop anaerobic fluidized bed (JBILAFB), was designed and constructed. The start-up and performance of the reactor was investigated in the Process. of .artificial glucose w... A novel anaerobic reactor, jet biogas inter-loop anaerobic fluidized bed (JBILAFB), was designed and constructed. The start-up and performance of the reactor was investigated in the Process. of .artificial glucose wastewater treatment. With the wastewater recycle ratio of 2.5 : 1, the recycled wastewater with biogas could mix sludge and wastewater in the JBILAFB reactor completely. The start-up of the JBILAFB reactor could be completed in less than 70 d through maintenance of hydraulic retention time (HR^I") and stepwise increase of feed total organic carbon (TOC) concentration. After the start-up, with the volumetric TOC loadings of 14.3 kg·m ^-3·d^-1, the TOC removal ratio, the effluent pH, and the volatile fatty acids (VFA)/alkalinity of the JBILAFB reactor were more than 80%, close to 7.0 and less than 0.4, respectively. Moreover, CH4 was produced at more than 70% of the theoretical value, The reactor exhibited high stability under the condition of high volumetric TOC loading. Sludge granules in the JBILAFB reactor were developed during the start-up and their sizes were enlarged with the stepwise increase of volumetric TOC loadings from 0.8 kg.m^-3.d ^-1 to 14.3 kg.m^-3.d^-1. Granules, an offwhite color and a similar spherical shape, were mainly comprised of global-like bacteria. These had good methanogenic activity and settleability, which were formed probably through adhesion of the bacteria. Some inorganic metal compounds such as Fe, Ca, Mg, Al, etc. were advantageous to the formation of the granules. 展开更多
关键词 anaerobic reactor jet biogas inter-loop anaerobic fluidized bed wastewater treatment start-up granule sludge
下载PDF
Experimental research on characteristic of start-up pressure wave propagation in gelled crude oil by large-scale flow loop 被引量:1
15
作者 崔秀国 艾慕阳 +2 位作者 姜保良 霍连风 张立新 《Journal of Central South University》 SCIE EI CAS 2008年第S1期467-470,共4页
In order to research start-up pressure wave propagation mechanism and determine pressure wave speed in gelled crude oil pipelines accurately,experiment of Large-scale flow loop was carried out.In the experiment,start-... In order to research start-up pressure wave propagation mechanism and determine pressure wave speed in gelled crude oil pipelines accurately,experiment of Large-scale flow loop was carried out.In the experiment,start-up pressure wave speeds under various operation conditions were measured,and effects of correlative factors on pressure wave were analyzed.The experimental and theoretical analysis shows that thermal shrinkage and structural properties of gelled crude oils are key factors influencing on start-up pressure wave propagation.The quantitative analysis for these effects can be done by using volume expansion coefficient and structural property parameter of gelled crude oil.A new calculation model of pressure wave speed was developed on the basis of Large-scale flow loop experiment and theoretical analysis. 展开更多
关键词 gelled CRUDE oil start-up pressure wave PROPAGATION CHARACTERISTIC lager-scale FLOW LOOP
下载PDF
Numerical Simulation of a Two-Phase Flow with Low Permeability anda Start-Up Pressure Gradient 被引量:1
16
作者 Xuanyu Dong Jingyao Yang 《Fluid Dynamics & Materials Processing》 EI 2023年第1期175-185,共11页
A new numerical model for low-permeability reservoirs is developed.The model incorporates the nonlinear characteristics of oil-water two-phase flows while taking into account the initiation pressure gradient.Related n... A new numerical model for low-permeability reservoirs is developed.The model incorporates the nonlinear characteristics of oil-water two-phase flows while taking into account the initiation pressure gradient.Related numerical solutions are obtained using a finite difference method.The correctness of the method is demonstrated using a two-dimensional inhomogeneous low permeability example.Then,the differences in the cumulative oil and water production are investigated for different starting water saturations.It is shown that when the initial water saturation grows,the water content of the block continues to rise and the cumulative oil production gradually decreases. 展开更多
关键词 Low-permeability reservoirs two-phase flow water cut start-up pressure gradient non-darcy flow
下载PDF
Start-up and contaminants removal characteristics of aerobic granules-membrane bioreactor at low temperature 被引量:1
17
作者 王硕 于水利 +2 位作者 时文歆 王玉兰 衣雪松 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2012年第1期67-70,共4页
In order to understand the effect of low temperature on the formation process of aerobic granules and contaminants removal characteristics,the aerobic granules-membrane bioreactor (AGS-MBR) has been started up and ope... In order to understand the effect of low temperature on the formation process of aerobic granules and contaminants removal characteristics,the aerobic granules-membrane bioreactor (AGS-MBR) has been started up and operated at low temperature using the carbon resource of sodium acetate. Aerobic granules cultivated in AGS-MBR possess smooth surface and compact structure in morphology as well as better settling property and higher biomass after 38 days. The average parameters of aerobic granules are: diameter 3. 1 mm,wet density 1. 041 g/mL,sludge volume index 42. 35 mL/g and settling velocity 20. 6 - 45. 2 cm/min. During the start-up of AGS-MBR,the respectively average contaminants removal efficiencies at low temperature are 91. 9% for chemical oxygen demand (COD) ,89. 2% for NH4 + -N and 86. 3% for PO43- -P,and the overgrowth of filamentous bacteria has been well controlled. In addition,the hollow fiber microfiltration (MF) membrane fouling is light and the regime membrane layer is capable of enhancing membrane filtration as well as the average growth of trans-membrane pressure (TMP) is 1. 07 kPa/d. Compared with the conventional cultivation of aerobic granules,the sludge granulation time significantly decreases from 73 days to 38 days by the application of microfiltration membrane at low temperature. 展开更多
关键词 Aerobic Granules-Membrane Bioreactor (AGS-MBR) Low Temperature start-up CONTAMINANTS Removal MICROFILTRATION (MF) Trans-Membrane Pressure (TMP)
下载PDF
Activation and shutdown dose-rate analyses for the EAST NBI test facility 被引量:1
18
作者 Yu-Qing Chen Ji Wang +4 位作者 Bin Wu Jun Li Ya-Hong Xie Guo-Qiang Zhong Chun-Dong Hu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第4期60-66,共7页
An analysis of the neutron activation and shutdown dose rates was performed for the EAST high-power deuterium neutral beam injector test facility(EAST NBITF) by using the multiparticle transport code FLUKA2011.2. Also... An analysis of the neutron activation and shutdown dose rates was performed for the EAST high-power deuterium neutral beam injector test facility(EAST NBITF) by using the multiparticle transport code FLUKA2011.2. Also, the neutron and neutron-induced gamma spectra of the facility's vacuum vessel were evaluated. The results identified the major radionuclides^(99) Mo,^(65)Ni,^(58) Co,^(56)Mn, and^(51) Cr for the vacuum vessel and the primary nuclide^(64) Cu for both the ion dump and the calorimeter.The simulated results indicated that, when the EAST NBITF operates within the design parameters of deuterium energy 80 ke V, current 50 A, and pulse 100 s, the neutron intensity will achieve 10^(11)n/s with no radiation safety problems after the EAST NBITF shuts down. 展开更多
关键词 剂量率 测试设备 停机 NBI 放射性核素 激活 中性束注入器 试验设施
下载PDF
Study on durability of Pt supported on graphitized carbon under simulated start-up/shut-down conditions for polymer electrolyte membrane fuel cells 被引量:2
19
作者 Won Suk Jung 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2018年第1期326-334,共9页
The primary issue for the commercialization of proton exchange membrane fuel cell(PEMFC) is the carbon corrosion of support under start-up/shut-down conditions. In this study, we employ the nanostructured graphitize... The primary issue for the commercialization of proton exchange membrane fuel cell(PEMFC) is the carbon corrosion of support under start-up/shut-down conditions. In this study, we employ the nanostructured graphitized carbon induced by heat-treatment. The degree of graphitization starts to increase between 900 and 1300 ℃ as evidenced by the change of specific surface area, interlayer spacing, and ID/IG value. Pt nanoparticles are deposited on fresh carbon black(Pt/CB) and carbon heat-treated at 1700 ℃(Pt/HCB17) with similar particle size and distribution. Electrochemical characterization demonstrates that the Pt/HCB17 shows higher activity than the Pt/CB due to the inefficient microporous structure of amorphous carbon for the oxygen reduction reaction. An accelerating potential cycle between 1.0 and 1.5 V for the carbon corrosion is applied to examine durability at a single cell under the practical start-up/shutdown conditions. The Pt/HCB17 catalyst shows remarkable durability after 3000 potential cycles. The Pt/HCB17 catalyst exhibits a peak power density gain of 3%, while the Pt/CB catalyst shows 65% loss of the initial peak power density. As well, electrochemical surface area and mass activity of Pt/HCB17 catalyst are even more stable than those of the Pt/CB catalyst. Consequently, the high degree of graphitization is essential for the durability of fuel cells in practical start-up/shut-down conditions due to enhancing the strong interaction of Pt and π-bonds in graphitized carbon. 展开更多
关键词 Polymer electrolyte membrane fuel ceils Membrane electrolyte assembly Carbon corrosion start-up/shut-down Durability
下载PDF
Implementation and application of PyNE sub-voxel R2S for shutdown dose rate analysis
20
作者 Xiaokang ZHANG Patrick C SHRIWISE +1 位作者 Songlin LIU Paul P H WILSON 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第9期145-151,共7页
PyNE R2S is a mesh-based R2S implementation with the capability of performing shutdown dose rate(SDR)analysis directly on CAD geometry with Cartesian or tetrahedral meshes.It supports advanced variance reduction for f... PyNE R2S is a mesh-based R2S implementation with the capability of performing shutdown dose rate(SDR)analysis directly on CAD geometry with Cartesian or tetrahedral meshes.It supports advanced variance reduction for fusion energy systems.However,the assumption of homogenized materials of PyNE R2S with a Cartesian mesh throughout a mesh voxel introduces an approximation in the case where a voxel covers multiple non-void cells.This work implements a sub-voxel method to add fldelity to PyNE R2S with a Cartesian mesh during the process of activation and photon source sampling by performing independent inventory calculations for each cell within a mesh voxel and using the results of those independent calculations to sample the photon source more precisely.PyNE sub-voxel R2S has been verifled with the Frascati Neutron Generator(FNG)-ITER and ITER computational shutdown dose rate benchmark problems.The results for sub-voxel R2S show satisfactory agreement with the experimental values or reference results.PyNE sub-voxel R2S has been applied to the shutdown dose rate calculation of the Chinese Fusion Engineering Testing Reactor(CFETR).In conclusion,sub-voxel R2S is a reliable tool for SDR calculation and obtains more accurate results with the same voxel size than voxel R2S. 展开更多
关键词 shutdown dose rate R2S sub-voxel PyNE
下载PDF
上一页 1 2 105 下一页 到第
使用帮助 返回顶部