This work presents a fuzzy based methodology for distribution system feeder reconfiguration considering DSTATCOM with an objective of minimizing real power loss and operating cost. Installation costs of DSTATCOM devic...This work presents a fuzzy based methodology for distribution system feeder reconfiguration considering DSTATCOM with an objective of minimizing real power loss and operating cost. Installation costs of DSTATCOM devices and the cost of system operation, namely, energy loss cost due to both reconfiguration and DSTATCOM placement, are combined to form the objective function to be minimized. The distribution system tie switches, DSTATCOM location and size have been optimally determined to obtain an appropriate operational condition. In the proposed approach, the fuzzy membership function of loss sensitivity is used for the selection of weak nodes in the power system for the placement of DSTATCOM and the optimal parameter settings of the DFACTS device along with optimal selection of tie switches in reconfiguration process are governed by genetic algorithm(GA). Simulation results on IEEE 33-bus and IEEE 69-bus test systems concluded that the combinatorial method using DSTATCOM and reconfiguration is preferable to reduce power losses to 34.44% for 33-bus system and to 45.43% for 69-bus system.展开更多
在弱交流系统下对于附带有STATCOM的电网换相换流器高压直流输电(Line Commutated Converter based High Voltage Direct Current, LCC-HVDC)系统,存在着LCC逆变站与STATCOM之间耦合导致LCC-HVDC系统的稳定裕度下降问题,这会减弱LCC-HVD...在弱交流系统下对于附带有STATCOM的电网换相换流器高压直流输电(Line Commutated Converter based High Voltage Direct Current, LCC-HVDC)系统,存在着LCC逆变站与STATCOM之间耦合导致LCC-HVDC系统的稳定裕度下降问题,这会减弱LCC-HVDC抑制换相失败的能力。此外,HVDC控制环节之中的电压指令电流控制(voltage dependent current order limiter, VDCOL)环节的输出电流指令大幅剧烈波动还有几率会导致HVDC系统在首次换相失败之后发生后续换相失败。针对上述问题提出了一种“改进参考电压”的思想,对STATCOM和VDCOL的参考电压与输入电压分别进行修正。首先在STATCOM原本的参考电压经过一个“虚拟电抗”之后得到一个新的参考电压,通过这个改进参考电压弱化了STATCOM电压外环控制模块与LCC逆变站的耦合,减小了交流系统等效阻抗的大小,提升了系统对干扰的抵抗能力。然后对VDCOL的输入电压进行改进,新的改进输入电压改善了故障后VDCOL输出电流指令的大幅剧烈波动情况。最后通过三个层次的对照试验,验证了所提方法的有效性。展开更多
There are several problems existing in the direct starting of asynchronous motor such as large starting current,reactive power absorption from network side and weak interference-resistance,etc.Aiming at this,a compreh...There are several problems existing in the direct starting of asynchronous motor such as large starting current,reactive power absorption from network side and weak interference-resistance,etc.Aiming at this,a comprehensive energy-saving optimization model of asynchronous motor for voltage regulation based on static synchronous compensator(STATCOM)is put forward.By analyzing the working principle and operation performance of static synchronous compensator regulating voltage,a new energy-efficient optimization method for asynchronous motor is proposed based on the voltage regulator model to achieve soft start,continuous dynamic reactive power compensation and the terminal voltage stability control.The multi-objective optimal operation of asynchronous motor is realized by controlling the inverter to adjust the reactive current dynamically.The strategy reduces the influence of starting current and grid voltage by soft starting,and realizes the function of reactive power compensation and terminal voltage stabilization.The effectiveness and superiority of the proposed model is verified by the simulation analysis and the results of comparison with the motor started directly.展开更多
为解决在电网换相换流器型直流输电LCC-HVDC(line commuted converter based high voltage direct cur⁃rent)受端经历大扰动时传统PI控制下的静止同步补偿器STATCOM(static synchronous compensator)加剧受端电压崩溃的问题,提出一种PI...为解决在电网换相换流器型直流输电LCC-HVDC(line commuted converter based high voltage direct cur⁃rent)受端经历大扰动时传统PI控制下的静止同步补偿器STATCOM(static synchronous compensator)加剧受端电压崩溃的问题,提出一种PI与滑模切换控制策略。在小扰动下PI控制的STATCOM通过混合无功灵敏度因子HRPSF(hybrid reactive power sensitivity factor)精确计算无功补偿,在大扰动下STATCOM控制系统切换到滑模控制,通过Lyapunov函数证明滑模控制系统最终会达到稳定。在MATLAB/Simulink平台上将所提出的控制策略应用于LCC-HVDC受端换流站的STATCOM中进行仿真分析,结果验证了其合理性与有效性。展开更多
For dealing with the resonance fault of ultra-high voltage transformers(UHVTs)with the parallel thyristor controlled reactor(TCR)+the filter compensator(FC)type static var compensator(SVC)caused by dc magnetic biasing...For dealing with the resonance fault of ultra-high voltage transformers(UHVTs)with the parallel thyristor controlled reactor(TCR)+the filter compensator(FC)type static var compensator(SVC)caused by dc magnetic biasing,a simulation model of UHVT with parallel SVC for the frequency analysis of the impedance characteristics and a magnetic-field coupling model for UHVT based on classic Jiles-Atherton hysteresis theories are constructed based on the MATLAB/Simulink platform.Both the theoretical and simulation results prove that the resonance fault is caused by the resonance point on the low-voltage side of the transformer,which will approach the 4th harmonic point under magnetic biasing.Based on the fault analysis,a new resonance control method is proposed by adding reactance with by-pass switches in series with FC branches.Under dc magnetic biasing,the cutoff of the by-pass switch will increase the series reactance rate of the FC branches and change the resonance point.In order to avoid the 7th harmonic increasement caused by this method,the firing angle of the TCR branches is locked between 130°and 180°.The effect of the proposed method is validated by the simulation model of a 750 kV UHVT and the results show that the mechanism analysis of the resonance fault is correct and the resonance control method is valid.展开更多
In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distributio...In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distribution static com-pensator which protects power quality problems in currents.Distribution Static Compensator(DSTATCOM)aid to enhances power factor and removes total har-monic distortion which is drawn from non-linear load.The D–Q reference theory based hysteresis current controller is employed to generate reference current for compensation of harmonics and reactive power,additionally Probabilistic Neural Network(PNN)classifier is used which easily separates exact harmonics.In the meantime fuzzy logic controller is also used to maintain capacitor DC-link poten-tial.When comparing to PI controller it decreases steady state time and reduces maximum peak overshoot.Cascaded H-bridge multilevel inverter converts direct current to Alternating current,through inductor opposite harmonics are injected in Power Control Centre reduces source current harmonics and reactive power.The implementation of CHBMLI in distribution STATic COMpensator simulation model is simulated by means of MATLAB.展开更多
基金supported by Borujerd Branch,Islamic Azad University Iran
文摘This work presents a fuzzy based methodology for distribution system feeder reconfiguration considering DSTATCOM with an objective of minimizing real power loss and operating cost. Installation costs of DSTATCOM devices and the cost of system operation, namely, energy loss cost due to both reconfiguration and DSTATCOM placement, are combined to form the objective function to be minimized. The distribution system tie switches, DSTATCOM location and size have been optimally determined to obtain an appropriate operational condition. In the proposed approach, the fuzzy membership function of loss sensitivity is used for the selection of weak nodes in the power system for the placement of DSTATCOM and the optimal parameter settings of the DFACTS device along with optimal selection of tie switches in reconfiguration process are governed by genetic algorithm(GA). Simulation results on IEEE 33-bus and IEEE 69-bus test systems concluded that the combinatorial method using DSTATCOM and reconfiguration is preferable to reduce power losses to 34.44% for 33-bus system and to 45.43% for 69-bus system.
文摘在弱交流系统下对于附带有STATCOM的电网换相换流器高压直流输电(Line Commutated Converter based High Voltage Direct Current, LCC-HVDC)系统,存在着LCC逆变站与STATCOM之间耦合导致LCC-HVDC系统的稳定裕度下降问题,这会减弱LCC-HVDC抑制换相失败的能力。此外,HVDC控制环节之中的电压指令电流控制(voltage dependent current order limiter, VDCOL)环节的输出电流指令大幅剧烈波动还有几率会导致HVDC系统在首次换相失败之后发生后续换相失败。针对上述问题提出了一种“改进参考电压”的思想,对STATCOM和VDCOL的参考电压与输入电压分别进行修正。首先在STATCOM原本的参考电压经过一个“虚拟电抗”之后得到一个新的参考电压,通过这个改进参考电压弱化了STATCOM电压外环控制模块与LCC逆变站的耦合,减小了交流系统等效阻抗的大小,提升了系统对干扰的抵抗能力。然后对VDCOL的输入电压进行改进,新的改进输入电压改善了故障后VDCOL输出电流指令的大幅剧烈波动情况。最后通过三个层次的对照试验,验证了所提方法的有效性。
文摘There are several problems existing in the direct starting of asynchronous motor such as large starting current,reactive power absorption from network side and weak interference-resistance,etc.Aiming at this,a comprehensive energy-saving optimization model of asynchronous motor for voltage regulation based on static synchronous compensator(STATCOM)is put forward.By analyzing the working principle and operation performance of static synchronous compensator regulating voltage,a new energy-efficient optimization method for asynchronous motor is proposed based on the voltage regulator model to achieve soft start,continuous dynamic reactive power compensation and the terminal voltage stability control.The multi-objective optimal operation of asynchronous motor is realized by controlling the inverter to adjust the reactive current dynamically.The strategy reduces the influence of starting current and grid voltage by soft starting,and realizes the function of reactive power compensation and terminal voltage stabilization.The effectiveness and superiority of the proposed model is verified by the simulation analysis and the results of comparison with the motor started directly.
文摘为解决在电网换相换流器型直流输电LCC-HVDC(line commuted converter based high voltage direct cur⁃rent)受端经历大扰动时传统PI控制下的静止同步补偿器STATCOM(static synchronous compensator)加剧受端电压崩溃的问题,提出一种PI与滑模切换控制策略。在小扰动下PI控制的STATCOM通过混合无功灵敏度因子HRPSF(hybrid reactive power sensitivity factor)精确计算无功补偿,在大扰动下STATCOM控制系统切换到滑模控制,通过Lyapunov函数证明滑模控制系统最终会达到稳定。在MATLAB/Simulink平台上将所提出的控制策略应用于LCC-HVDC受端换流站的STATCOM中进行仿真分析,结果验证了其合理性与有效性。
基金The Science Foundation of State Grid Xinjiang(No.SGTYHT/19-JS-215)。
文摘For dealing with the resonance fault of ultra-high voltage transformers(UHVTs)with the parallel thyristor controlled reactor(TCR)+the filter compensator(FC)type static var compensator(SVC)caused by dc magnetic biasing,a simulation model of UHVT with parallel SVC for the frequency analysis of the impedance characteristics and a magnetic-field coupling model for UHVT based on classic Jiles-Atherton hysteresis theories are constructed based on the MATLAB/Simulink platform.Both the theoretical and simulation results prove that the resonance fault is caused by the resonance point on the low-voltage side of the transformer,which will approach the 4th harmonic point under magnetic biasing.Based on the fault analysis,a new resonance control method is proposed by adding reactance with by-pass switches in series with FC branches.Under dc magnetic biasing,the cutoff of the by-pass switch will increase the series reactance rate of the FC branches and change the resonance point.In order to avoid the 7th harmonic increasement caused by this method,the firing angle of the TCR branches is locked between 130°and 180°.The effect of the proposed method is validated by the simulation model of a 750 kV UHVT and the results show that the mechanism analysis of the resonance fault is correct and the resonance control method is valid.
文摘In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distribution static com-pensator which protects power quality problems in currents.Distribution Static Compensator(DSTATCOM)aid to enhances power factor and removes total har-monic distortion which is drawn from non-linear load.The D–Q reference theory based hysteresis current controller is employed to generate reference current for compensation of harmonics and reactive power,additionally Probabilistic Neural Network(PNN)classifier is used which easily separates exact harmonics.In the meantime fuzzy logic controller is also used to maintain capacitor DC-link poten-tial.When comparing to PI controller it decreases steady state time and reduces maximum peak overshoot.Cascaded H-bridge multilevel inverter converts direct current to Alternating current,through inductor opposite harmonics are injected in Power Control Centre reduces source current harmonics and reactive power.The implementation of CHBMLI in distribution STATic COMpensator simulation model is simulated by means of MATLAB.