BACKGROUND:Coronary angiogram and percutaneous coronaryangioplasty are becoming important techniques to make diagnosisand relieve symptoms for the patients with CAD.But higherincidence of hypersensitivity when meglumi...BACKGROUND:Coronary angiogram and percutaneous coronaryangioplasty are becoming important techniques to make diagnosisand relieve symptoms for the patients with CAD.But higherincidence of hypersensitivity when meglumine diatrizoateas as a agent todo iodum sensitivity test will make some difficuties in practice of CAGand PTCA.PURPOSE:Using iohexol instead of meglumine diatrizoateas a agent to take sensitivity test may be helpful to promote theprevalance the CAG and PTCA in clinical.METHODS ANDPATIENTS:850 patients were enrolled into this study.Patients withpositive reaction when meglumine diatrizoate as a agent to do sensitivitytest accepted the second test using Iohexol.RESULTS:21 Patientaccepted the second test in this study,of the patients,only 1 patient had asame complaints during the 1st and 2nd test.then was rejected to give herCAG and PTCA procedures.The others with positive reaction during 1sttest showed negative reaction during 2nd test,then accepted CAG andPTCA procedure.All the 20 patients underwent CAG and PTCA had noallergic reaction during the procedure.CONCLUSION:Using iohexolinstead of meglumine diatrizoate as a agent to do iodum-sensitivity testmay be helpful to reduce incidence of the false hypersensitive to iodumand promote the practice of CAG and PTCA in clinical.展开更多
文摘BACKGROUND:Coronary angiogram and percutaneous coronaryangioplasty are becoming important techniques to make diagnosisand relieve symptoms for the patients with CAD.But higherincidence of hypersensitivity when meglumine diatrizoateas as a agent todo iodum sensitivity test will make some difficuties in practice of CAGand PTCA.PURPOSE:Using iohexol instead of meglumine diatrizoateas a agent to take sensitivity test may be helpful to promote theprevalance the CAG and PTCA in clinical.METHODS ANDPATIENTS:850 patients were enrolled into this study.Patients withpositive reaction when meglumine diatrizoate as a agent to do sensitivitytest accepted the second test using Iohexol.RESULTS:21 Patientaccepted the second test in this study,of the patients,only 1 patient had asame complaints during the 1st and 2nd test.then was rejected to give herCAG and PTCA procedures.The others with positive reaction during 1sttest showed negative reaction during 2nd test,then accepted CAG andPTCA procedure.All the 20 patients underwent CAG and PTCA had noallergic reaction during the procedure.CONCLUSION:Using iohexolinstead of meglumine diatrizoate as a agent to do iodum-sensitivity testmay be helpful to reduce incidence of the false hypersensitive to iodumand promote the practice of CAG and PTCA in clinical.