ICRF Heated Long-Pulse Plasma Discharges in LHD 被引量:4
1
作者 R. KUMAZAWA T. SEKI +54 位作者 T. MUTOH K. SAITO T. WATARI Y. NAKAMURA M. SAKAMOTO T. WATANABE S. KUBO T. SHIMOZUMA Y. YOSHIMURA H. IGAMI Y. TAKEIRI Y. OKA K. TSUMORI M. OSAKABE K. IKEDA K. NAGAOKA O. KANEKO J. MIYAZAWA S. MORITA K. NARIHARA M. SHOJI S. MASUZAKI M. GOTO T. MORISAKI B. J. PETERSON K. SATO T. TOKUZAWA N. ASHIKAWA K. NISHIMURA H. FUNABA H. CHIKARAISHI T. NOTAKE Y. TORII H. OKADA M. ICHIMURA H. HIGAKI Y. TAKASE H. KASAHARA F. SHIMPO G.NOMURA C.TAKAHASHI M.YOKOTA A. KATO 赵燕平 J. S. YOON J. G. KWAK H. YAMADA K. KAWAHATA N. OHYABU K. IDA Y. NAGAYAMA N. NODA A. KOMORI S. SUDO O. MOTOJIMA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第1期28-32,共5页
A long-pulse plasma discharge for more than 30 min. was achieved on the Large Helical Device (LHD). A plasma of ne = 0.8 × 10^19 m^-3 and T10 = 2.0 keV was sustained with PICH = 0.52 MW, PECH = 0.1 MW and avera... A long-pulse plasma discharge for more than 30 min. was achieved on the Large Helical Device (LHD). A plasma of ne = 0.8 × 10^19 m^-3 and T10 = 2.0 keV was sustained with PICH = 0.52 MW, PECH = 0.1 MW and averaged PNBI = 0.067 MW. Total injected heating energy was 1.3 G J, which was a quarter of the prepared RF heating energy. One of the keys to the success of the experiment was a dispersion of the local plasma heat load to divertors, accomplished by shifting the magnetic axis inward and outward. 展开更多
关键词 helical/stellarator configuration ICRF heating steady state operation
下载PDF
Power Balance Estimation in Long Duration Discharges on QUEST 被引量:1
2
作者 K.HANADA H.ZUSHI +18 位作者 H.IDEI K.NAKAMURA M.ISHIGURO S.TASHIMA E.I.KALINNIKOVA Y.NAGASHIMA M.HASEGAWA A.FUJISAWA A.HIGASHIJIMA S.KAWASAKI H.NAKASHIMA O.MITARAI A.FUKUYAMA Y.TAKASE X.GAO H.LIU J.QIAN M.ONO R.RAMAN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第11期1069-1075,共7页
Fully non-inductive plasma start-up was successfully achieved by using a well- controlled microwave source on the spherical tokamak, QUEST. Non-inductive plasmas were maintained for approximately 3-5 min, during which... Fully non-inductive plasma start-up was successfully achieved by using a well- controlled microwave source on the spherical tokamak, QUEST. Non-inductive plasmas were maintained for approximately 3-5 min, during which time power balance estimates could be achieved by monitoring wall and cooling-water temperatures. Approximately 70%-90% of the injected power could be accounted for by calorimetric measurements and approximately half of the injected power was found to be deposited on the vessel wall, which is slightly dependent on the magnetic configuration. The power distribution to water-cooled limiters, which are expected to be exposed to local heat loads, depends significantly on the magnetic configuration, however some of the deposited power is due to energetic electrons, which have large poloidal orbits and are likely to be deposited on the plasma facing components. 展开更多
关键词 steady state operation spherical tokamak plasma wall interaction power balance
下载PDF
Analysis of Higher Order System with Impulse Exciting Functions in Z-Domain
3
作者 Branislav Dobrucký Pavol Štefanec +2 位作者 Mariana Beňová Oleg V. Chernoyarov Michal Pokorný 《Circuits and Systems》 2016年第11期3951-3970,共20页
This paper deals with mathematical modelling of impulse waveforms and impulse switching functions used in electrical engineering. Impulse switching functions are later investigated using direct and inverse z-transform... This paper deals with mathematical modelling of impulse waveforms and impulse switching functions used in electrical engineering. Impulse switching functions are later investigated using direct and inverse z-transformation. The results make possible to present those functions as infinite series expressed in pure numerical, exponential or trigonometric forms. The main advantage of used approach is the possibility to calculate investigated variables directly in any instant of time;dynamic state can be solved with the step of sequences (T/6, T/12) that means very fast. Theoretically derived waveforms are compared with simulation worked-out results as well as results of circuit emulator LT spice which are given in the paper. 展开更多
关键词 Impulse Systems Switching Function Z-Transformation Inverse Z-Transformation steady state operation Dynamical state Model Modelling and Simulation
下载PDF
Transient Behaviour of a Heat Pipe with Extracapillary Circulation 被引量:1
4
作者 G. Canti, G.P. Celata, M. Cumo, M. Furrer ENEA Energy Department, Rome, Italy 《Tsinghua Science and Technology》 SCIE EI CAS 2002年第2期135-145,共11页
Heat pipe devices, for their typical working mode, are particularly suitable for zero gravity applications, and have also been considered for applications in space satellites with nuclear generators because of the a... Heat pipe devices, for their typical working mode, are particularly suitable for zero gravity applications, and have also been considered for applications in space satellites with nuclear generators because of the absence of active systems for the coolant circulation. The present work reports the results of experimental tests carried out on a heat pipe facility designed to investigate the thermal hydraulic performance of a water heat pipe. The device layout, configuration and geometry, simulate a heat pipe working mode utilizable in space applications under zero gravity conditions. The evaporating section, completely lined (covered) with wicks (sintered stainless steel), and nearly plane shaped, is housed in a cylindrical container. The obtained results show that the system can approach steady state conditions, at a pressure of 4 bar and with a heat flux transferred of about 150 W/cm 2, supporting an electric power step of about 1.8 kW. 展开更多
关键词 steady state operating conditions heat pipe transient phrases CIRCULATION