期刊文献+
共找到5,208篇文章
< 1 2 250 >
每页显示 20 50 100
Masseter Vestibular evoked myogenic potentials: A new tool to assess the vestibulomasseteric reflex pathway
1
作者 Aishwarya Nagarajan Sujeet Kumar Sinha 《Journal of Otology》 CAS CSCD 2024年第1期46-54,共9页
Purpose: This review article provides the readers with an in-depth insight in understanding and interpreting various research literatures on the masseter vestibular evoked myogenic potentials(mVEMP). The article also ... Purpose: This review article provides the readers with an in-depth insight in understanding and interpreting various research literatures on the masseter vestibular evoked myogenic potentials(mVEMP). The article also reviews the contemporary researches involving the clinical applications of the mVEMP. Conclusions: Masseter VEMP is an evolving yet clinically promising neuro-otology test tool that has recently gained more research interest and is considered an additional tool to diagnose various vestibular disorders. Masseter VEMP assesses the functional integrity of the acoustic-masseteric and vestibulo-masseteric reflex pathways. The mVEMP could be used as a complementary test to evaluate the same peripheral generator as the cervical VEMP but a different central pathway i.e., vestibulo-trigeminal pathway. Various research studies that have experimented on parameters such as the effect of different electrode montages(zygomatic vs mandibular configurations), stimulation rates, filter settings and stimuli used to evoke mVEMP have been discussed in this article that could assist in the optimization of a comprehensive clinical protocol. The latency and the amplitude of mVEMP waveforms serve as significant parameters in differentiating normals from those of the clinical populations. Along with the cVEMPs and oVEMPs, mVEMP might help diagnose brainstem lesions in REM Sleep behaviour disorders, Multiple Sclerosis and Parkinson's disease. However, further studies are required to probe in this area of research. 展开更多
关键词 Masseter vestibular evoked myogenic potentials(mVEMP) Vestibulo-masseteric pathway Acoustic-masseteric pathway
下载PDF
Median Nerve Somatosensory Evoked Potentials in Patients with Chiari Malformation
2
作者 Mustafa Harun Sahin Gonul Vural +1 位作者 Serdar Barakli Sadiye Gumusyayla 《World Journal of Neuroscience》 CAS 2024年第1期24-32,共9页
Abnormal SEP reflects dysfunction of the medial lemniscus and posterior cervical cord. These structures are likely to be affected in Chiari malformation. Therefore, SEP abnormalities may provide valuable information i... Abnormal SEP reflects dysfunction of the medial lemniscus and posterior cervical cord. These structures are likely to be affected in Chiari malformation. Therefore, SEP abnormalities may provide valuable information in patients with CM. However, the consistency of SEP abnormality or normality with the damage is a matter of research. Knowing whether median nerve somatosensory evoked potential (SEP) is useful in revealing subclinical damage in patients with Chiari malformation is important in the treatment and follow-up plan of the disease. The aim of this study was to investigate the relationship between median nerve SEP values and the severity of cerebellar ectopia in patients with Chiari type 1 malformation. Median nerve SEP values were obtained from 30 healthy individuals and 146 individuals with Chiari malformation. The cerebellar ectopia degree and McRae line length were measured. SEP values were not significantly different between groups. The McRae line was found to be significantly shorter in the control group than in the Chiari malformation group (p = 0.031). There was no correlation between the degree of cerebellar ectopia and the length of the McRae line (r = 0.002, p = 0.979). Neither cerebellar ectopy degree nor McRae line length had a relationship with SEP values (r = -0.153, p = 0.066;r = -0.056, p = 0.500, respectively). There was no difference in cerebellar ectopy degree or SEP values between the groups with cerebellar ectopy with and without a syrinx (p = 0.899;p = 0.080, respectively). Likewise, McRae line length was not found to be related to the presence of a syrinx (p = 0.139). Median nerve SEP examination was not beneficial for diagnosing asymptomatic-oligosymptomatic Chiari malformation as a subclinical injury, whether accompanied by syringomyelia or not. 展开更多
关键词 Chiari Malformation Cerebellar Ectopy Somatosensory evoked potential
下载PDF
Observing the steady-state visual evoked potentials with a compact quad-channel spin exchange relaxation-free magnetometer 被引量:5
3
作者 杜鹏程 李建军 +4 位作者 杨思嘉 王旭桐 卓彦 王帆 王如泉 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第4期141-144,共4页
We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of ... We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of data were collected, and SSVEP-related magnetic responses with signal intensity ranging from 150 fT to 300 f T were observed for all four channels. The corresponding signal to noise ratio(SNR) was in the range of 3.5–5.5. We then used different channels to operate the sensor as a gradiometer. In the specific case of detecting SSVEP, we noticed that the short channel separation distance led to a strongly diminished gradiometer signal. Although not optimal for the case of SSVEP detection, this set-up can prove to be highly useful for other magnetoencephalography(MEG) paradigms that require good noise cancellation.Considering its compactness, low cost, and good performance, the K-SERF sensor has great potential for biomagnetic field measurements and brain-computer interfaces(BCI). 展开更多
关键词 optically pumped MAGNETOMETERS steady-state visually evoked potentials MAGNETOENCEPHALOGRAPHY
下载PDF
Influence of stimuli color on steady-state visual evoked potentials based BCI wheelchair control
4
作者 Rajesh Singla Arun Khosla Rameshwar Jha 《Journal of Biomedical Science and Engineering》 2013年第11期1050-1055,共6页
In recent years, Brain Computer Interface (BCI) systems based on Steady-State Visual Evoked Potential (SSVEP) have received much attention. This study tries to develop a SSVEP based BCI system that can control a wheel... In recent years, Brain Computer Interface (BCI) systems based on Steady-State Visual Evoked Potential (SSVEP) have received much attention. This study tries to develop a SSVEP based BCI system that can control a wheelchair prototype in five different positions including stop position. In this study four different flickering frequencies in low frequency region were used to elicit the SSVEPs and were displayed on a Liquid Crystal Display (LCD) monitor using Lab-VIEW. Four stimuli colors, green, red, blue and violet were used to investigate the color influence in SSVEPs. The Electroencephalogram (EEG) signals recorded from the occipital region were segmented into 1 second window and features were extracted by using Fast Fourier Transform (FFT). One-Against-All (OAA), a popular strategy for multiclass SVM, is used to classify SSVEP signals. During stimuli color comparison SSVEP with violet color showed higher accuracy than that with green, red and blue stimuli. 展开更多
关键词 steady-state Visual evoked potential Brain Computer Interface Support Vector MACHINES
下载PDF
Identification of injury type using somatosensory and motor evoked potentials in a rat spinal cord injury model
5
作者 Rong Li Han-Lei Li +2 位作者 Hong-Yan Cui Yong-Can Huang Yong Hu 《Neural Regeneration Research》 SCIE CAS CSCD 2023年第2期422-427,共6页
The spinal cord is at risk of injury during spinal surgery.If intraoperative spinal co rd injury is identified early,irreve rsible impairment or loss of neurological function can be prevented.Different types of spinal... The spinal cord is at risk of injury during spinal surgery.If intraoperative spinal co rd injury is identified early,irreve rsible impairment or loss of neurological function can be prevented.Different types of spinal cord injury result in damage to diffe rent spinal cord regions,which may cause diffe rent somatosensory and motor evoked potential signal res ponses.In this study,we examined electrophysiological and histopathological changes between contusion,distra ction,and dislocation spinal cord injuries in a rat model.We found that contusion led to the most severe dorsal white matter injury and caused considerable attenuation of both somatosensory and motor evoked potentials.Dislocation resulted in loss of myelinated axons in the lateral region of the injured spinal cord along the rostrocaudal axis.The amplitude of attenuation in motor evoked potential responses caused by dislocation was greater than that caused by contusion.After distraction injury,extracellular spaces were slightly but not significantly enlarged;somatosensory evoked potential res ponses slightly decreased and motor evoked potential responses were lost.Correlation analysis showed that histological and electrophysiological findings we re significantly correlated and related to injury type.Intraope rative monitoring of both somatosensory and motor evoked potentials has the potential to identify iatrogenic spinal cord injury type during surgery. 展开更多
关键词 contusion injury dislocation injury distraction injury electropnysiology heterogeneity HISTOPATHOLOGY injury mechanism motor evoked potential somatosensory evoked potential spinal cord injury
下载PDF
Functional near-infrared spectroscopy can detect low-frequency hemodynamic oscillations in the prefrontal cortex during steady-state visual evoked potentialinducing periodic facial expression stimuli presentation
6
作者 Meng-Yun Wang Anzhe Yuan +2 位作者 Juan Zhang Yutao Xiang Zhen Yuan 《Visual Computing for Industry,Biomedicine,and Art》 2020年第1期321-328,共8页
Brain oscillations are vital to cognitive functions,while disrupted oscillatory activity is linked to various brain disorders.Although high-frequency neural oscillations(>1 Hz)have been extensively studied in cogni... Brain oscillations are vital to cognitive functions,while disrupted oscillatory activity is linked to various brain disorders.Although high-frequency neural oscillations(>1 Hz)have been extensively studied in cognition,the neural mechanisms underlying low-frequency hemodynamic oscillations(LFHO)<1 Hz have not yet been fully explored.One way to examine oscillatory neural dynamics is to use a facial expression(FE)paradigm to induce steady-state visual evoked potentials(SSVEPs),which has been used in electroencephalography studies of high-frequency brain oscillation activity.In this study,LFHO during SSVEP-inducing periodic flickering stimuli presentation were inspected using functional near-infrared spectroscopy(fNIRS),in which hemodynamic responses in the prefrontal cortex were recorded while participants were passively viewing dynamic FEs flickering at 0.2 Hz.The fast Fourier analysis results demonstrated that the power exhibited monochronic peaks at 0.2 Hz across all channels,indicating that the periodic events successfully elicited LFHO in the prefrontal cortex.More importantly,measurement of LFHO can effectively distinguish the brain activation difference between different cognitive conditions,with happy FE presentation showing greater LFHO power than neutral FE presentation.These results demonstrate that stimuli flashing at a given frequency can induce LFHO in the prefrontal cortex,which provides new insights into the cognitive mechanisms involved in slow oscillation. 展开更多
关键词 Steady state visual evoked potentials Dynamic facial expressions Functional near-infrared spectroscopy Brain oscillation
下载PDF
Correlation study between the changes of motor evoked potential and the improvement of spinal canal volume in minimally invasive transforaminal lumbar interbody fusion
7
作者 CHEN Huan-xiong HE Xian-bo +6 位作者 LI Guo-jun TANG Song-jie ZHONG Zhen-hao HUANG Tao LIN You-cai LIN Su-yu MENG Zhi-bin 《Journal of Hainan Medical University》 CAS 2023年第8期26-31,共6页
Objective:To analyze the correlation between the amplitude changes of motor evoked potential(MEP),the 3D volume changes of spinal canal measuring by postoperative CT and the improvement rate of clinical symptoms after... Objective:To analyze the correlation between the amplitude changes of motor evoked potential(MEP),the 3D volume changes of spinal canal measuring by postoperative CT and the improvement rate of clinical symptoms after the spinal canal decompression in minimally invasive transforaminal lumbar interbody fusion(MIS-TLIF),and to explore the predictive value of the changes of both MEP amplitude and spinal canal volume in the assessment of long-term clinical prognosis in MIS-TLIF.Methods:A retrospective study of 68 patients with L4/5 spinal stenosis treated with MIS-TLIF was performed.The changes of both intraoperative MEP amplitude and 3D spinal canal volume during the spinal canal decompression,as well as the visual analogue scale(VAS)and Oswestry dysfunction index(ODI)scores in the long-term follow-up were all recorded.Results:The values of intraoperative MEP amplitude was 159.04%higher in 68 patients with MIS-TLIF after spinal canal decompression(P<0.01).The 3 postoperative 3D spinal canal volume(4.89±1.27)cm increased by 31.22%in comparison 3 with preoperative date(3.78±1.08)cm(P<0.01).The VAS and ODI scores were improved to 78.55%and 80.60%,respectively at the last follow-up(P<0.01).The improvement rate of MEP amplitude on the decompression side was positively correlated with the improvement rate of postoperative spinal canal volume(r=0.272,P=0.025).The improvement rate of postoperative spinal canal volume was positively correlated with the improvement rate of VAS and ODI at the last follow-up(r=0.656,r=0.490,P<0.01).Moreover,the improvement rate of MEP amplitude on the decompression side was also positively correlated with the improvement rate of VAS and ODI at the last follow-up(r=0.322 and 0.235,respectively,P<0.05).Conclusion:The increase of MEP amplitude after spinal canal decompression in patients with lumbar spinal stenosis treated by MIS-TLIF was closely correlated with both of the increase of spinal canal volume and the improvement of clinical symptoms.Therefore,MEP amplitude monitoring was not only the one of the important monitoring methods for predicting the prognosis of MIS-TLIF but also the reliably predictive value in the long-term clinical prognosis in MIS-TLIF. 展开更多
关键词 Lumbar spinal stenosis Minimally invasive transforaminal lumbar interbody fusion Motor evoked potentials Spinal canal volume
下载PDF
Application of pudendal evoked potentials in diagnosis of erectile dysfunction 被引量:6
8
作者 Guang-You ZHU Yan SHEN Institute of Forensic Sciences, Ministry of Justice, Shanghai 200063, China 《Asian Journal of Andrology》 SCIE CAS CSCD 1999年第3期145-150,共6页
Aim: Extensive neurophysiological investigations were carried out in 100 healthy subjects and 84 patients with penileerectile dysfunction. Methods: Following examinations were performed, spinal and scalp somatosensory... Aim: Extensive neurophysiological investigations were carried out in 100 healthy subjects and 84 patients with penileerectile dysfunction. Methods: Following examinations were performed, spinal and scalp somatosensory evoked poten-tials (SEPs) to stimulation of the dorsal nerve of penis, motor evoked potentials (MEPs) from bulbocavernosus (BC) inresponse to scalp and spinal root stimulation, and measurement of sacral reflex latency (SRL) from anal sphincter (AS).Results: In the healthy subjects, the mean sensory total conduction time (sensory TCT), as measured at the peak of thescalp P1 (P40) wave was 39.73 ms. The mean sensory central conduction time (sensory CCT = spinal-to-scalp conductiontime) was 28.98 ms. The mean peripheral conduction time (PCP) was 9.40 ins. Transcranial brain stimulation was per-formed by using a magnetic stimulator during voluntary contraction of the examined muscle. Spinal root stimulation wasperformed at rest. Motor total conduction time (motor TCT) to BC muscles was 20.48 ms. Motor central conductiontime (motor CCT) to sacral cord segments controlling BC muscles was 14.42 ms at rest. The mean SRL was 35.13 ms.Conclusion: Combined or isolated abnormalities of SEPs, MEPs, and SRL were found in patients with erectile dysfunc-tion. (Asian J Androl 1999 Sep; 1 : 145 - 150) 展开更多
关键词 erectile dysfunction pudendal evoked potential pelvic fracture spinal injury DIABETES MASTURBATION
下载PDF
Monitoring somatosensory evoked potentials in spinal cord ischemia-reperfusion injury 被引量:5
9
作者 Yiming Ji Bin Meng +2 位作者 Chenxi Yuan Huilin Yang Jun Zou 《Neural Regeneration Research》 SCIE CAS CSCD 2013年第33期3087-3094,共8页
It remains unclear whether spinal cord ischemia-reperfusion injury caused by ischemia and other non-mechanical factors can be monitored by somatosensory evoked potentials. Therefore, we monitored spinal cord ischemia-... It remains unclear whether spinal cord ischemia-reperfusion injury caused by ischemia and other non-mechanical factors can be monitored by somatosensory evoked potentials. Therefore, we monitored spinal cord ischemia-reperfusion injury in rabbits using somatosensory evoked potential detection technology. The results showed that the somatosensory evoked potential latency was significantly prolonged and the amplitude significantly reduced until it disappeared during the period of spinal cord ischemia. After reperfusion for 30-180 minutes, the amplitude and latency began to gradually recover; at 360 minutes of reperfusion, the latency showed no significant difference compared with the pre-ischemic value, while the somatosensory evoked potential amplitude in- creased, and severe hindlimb motor dysfunctions were detected. Experimental findings suggest that changes in somatosensory evoked potentia~ ~atency can reflect the degree of spinat cord ischemic injury, while the amplitude variations are indicators of the late spinal cord reperfusion injury, which provide evidence for the assessment of limb motor function and avoid iatrogenic spinal cord injury. 展开更多
关键词 neural regeneration spinal cord injury somatosensory evoked potentials spinal cord ischemia REPERFUSION iatrogenic spinal cord injury HISTOPATHOLOGY abdominal aorta occlusion model latency grants-supported paper NEUROREGENERATION
下载PDF
Effect of sodium tungstate on visual evoked potentials in diabetic rats 被引量:2
10
作者 Mehmet Bulut Bariszgür Dnmez +4 位作者 Nihai ztürk Gksum Basaranlar Ceren Kencebay Manas Narin Derin Semir zdemir 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第5期677-681,共5页
AIM: To evaluate the effect of sodium tungstate on visual evoked potentials(VEPs) in diabetic rats.· METHODS: Wistar rats were randomly divided into three groups as normal control, diabetic control and diabet... AIM: To evaluate the effect of sodium tungstate on visual evoked potentials(VEPs) in diabetic rats.· METHODS: Wistar rats were randomly divided into three groups as normal control, diabetic control and diabetic rats treated with sodium tungstate. Diabetes was induced by single intraperitoneal injection of streptozotocin(50 mg/kg). Sodium tungstate [40 mg/(kg·d)]was administered for 12 wk and then VEPs were recorded.Additionally, thiobarbituric acid reactive substance(TBARS) levels were measured in brain tissues.·RESULTS: The latencies of P1, N1, P2, N2 and P3 waves were significantly prolonged in diabetic rats compared with control group. Diabetes mellitus caused an increase in the lipid peroxidation process that was accompanied by changes in VEPs. However, prolonged latencies of VEPs for all components returned to control levels in sodium tungstate-treated group. The treatment of sodium tungstate significantly decreased brain TBARS levels and depleted the prolonged latencies of VEP components compared with diabetic control group.· CONCLUSION: Sodium tungstate shows protective effects on visual pathway in diabetic rats, and it can be worthy of further study for potential use. 展开更多
关键词 DIABETES RETINOPATHY sodium tungstate visual evoked potentials lipid peroxidation
下载PDF
Specificity and sensitivity of visual evoked potentials P100 latency to different events exercise 被引量:3
11
作者 Jing-Guo Zhao Shu-Juan Pang Guang-Wei Che 《Health》 2009年第1期47-50,共4页
Visual evoked potentials (VEPs) are a series of signals about visual occipital cortex in response to visual stimuli and can be used as one of ob-jective non-invasive neuro-physiological pa-rameters to reflect the visu... Visual evoked potentials (VEPs) are a series of signals about visual occipital cortex in response to visual stimuli and can be used as one of ob-jective non-invasive neuro-physiological pa-rameters to reflect the visual organs and central visual pathway’s functional integrity. Previous studies have shown that acute and chronic ex-ercise could affect VEPs independent from body temperature and other physiological parameters. VEPs may well be used as neuro-physiological criteria in defining the performances of the ath-letes. Different sports training have different effects on VEPs, but the results are not consis-tent. P100 latency is the representative compo-nent of VEPs and it is of high, steady amplitude and of slight intra- and inter-individual variabil-ity so that the index is most commonly used. The purpose of this study was to investigate the specificity and sensitivity of P100 latency to dif-ferent physical activities. The neural electricity device of NDI-200 was used to measure the pattern reversal VEPs of all subjects, including the values of the resting state before and after different events exercise. Different events exer-cise contained an aerobic cycloergometric ex-ercise (7 subjects were conducted to a Bruce Graded Exercise Test on the Monark Ergomedic 839E cycloergometer, THR (target heart rate) = 85% HRmax, 3 times/week, about 10 minutes once time, 6 weeks), tennis training (16 volun-teers, 2 hours/day, 3 days/week, 8 weeks), aerobic Latin exercise (7 subjects, 1 hour/day, 3 days/week, 6 weeks) and the Baduanjin of Health Qigong training (6 subjects, 1 hour/day, 3 days/week, 6 weeks). The VEPs recordings of the control groups obtained synchronized with the experimental groups. SPSS 11.5 for win-dows was used for statistical analysis. A level of P﹤0.05 was accepted as statistically significant. The VEPs P100 latency of post-exercise of all experimental groups except Baduanjin group became shorter significantly compared with those of pre-exercise (P﹤0.05). No significant difference was found between pre-and post- exercise for the control groups. This study showed that exercise could shorten the P100 la-tency significantly. Moreover, it also indicated that VEPs were sensitive to exercise to a certain extent. We concluded that VEPs might well be used as neuro-physiological criteria in defining the performances of the athletes. It was found that the VEPs P100 latency became shorter after most training programs;furthermore, it demon-strated that P100 latency of VEPs had little specificity to different events. 展开更多
关键词 Visual evoked potentials P100 LATENCY SPECIFICITY Sensitivity
下载PDF
EFFECTS OF ACUPUNCTURE ON SENSORY EVOKED CORTICAL POTENTIALS IN RABBITS 被引量:1
12
作者 张文彬 沈雪勇 《World Journal of Acupuncture-Moxibustion》 1999年第2期45-50,共6页
The effects of acupuncture on the sensory evoked cortical potentials were investigated in 31 rabbits anaesthetized with urethane of conscious, so as to see what happened to the functional state of cerebral cortex in t... The effects of acupuncture on the sensory evoked cortical potentials were investigated in 31 rabbits anaesthetized with urethane of conscious, so as to see what happened to the functional state of cerebral cortex in the meantime. The visual, auditory and somatosensory evoked potentials as well as raw EEGs were recorded from the animal’s scalp. In most cases, an electro-acupuncture instrument was used instead of manual acupuncture. The main component amplitudes of evoked potentials,the frequency band powers and the total integral values of raw EEGs were analyzed. Results showed that during acupuncture the main components of evoked potentials were significantly depressed and the raw EEGs appeared desynchronized while the experimental animals were slightly activated. Moreover,both the total integral values of raw EEGs and the powers of lower frequency waves (1 - 3. 99 Hz)were decreased and positively correlated well with the amplitudes of main components of the evoked potentials. Therefore, the possibility that the effects of acupuncture on the evoked potentials are secondary to the changes of raw EEGs remains to be ruled out, and it is suggested that the inhibition of evoked potentials during acupuncture does not necessarily mean that the cerebral cortex is in an inhibitory 展开更多
关键词 evoked cortical potentials Auditory evoked potentials SOMATOSENSORY evoked potentials Visual evoked potentials POWERS spectrum analysis
下载PDF
Vestibular-evoked myogenic potentials recorded from miniature pigs and rats 被引量:2
13
作者 Li Ya Zhang Yan +4 位作者 Qiu Shi Wei Yuan Na Shi Xi Qiao Yuehua Shi-Ming Yang 《Journal of Otology》 CSCD 2016年第3期138-143,共6页
Objective:To report vestibular evoked myogenic potentials from different recording sites(neck extensor or masseter muscles) in miniature pigs and rats.Methods:Potentials were recorded using 1000 Hz tone bursts from th... Objective:To report vestibular evoked myogenic potentials from different recording sites(neck extensor or masseter muscles) in miniature pigs and rats.Methods:Potentials were recorded using 1000 Hz tone bursts from the neck extensor muscle or masseter muscle in normal adult Bama miniature pigs and rats anesthetized with 3%pentobarbital sodium and Sumianxin Ⅱ.Results:At 80 dB SPL,the first positive wave(P wave) of VEMPs was recognizable in 58%of rats with a latency of 6.45±0.23 ms and an amplitude of 1.45±0.49 μV when recorded from the neck extensor muscle,and in 50%of rats with a latency of 6.38±0.34 ms and an amplitude of 1.57±0.35 μV when recorded from the masseter muscle.In miniature pigs,at the same stimulus intensity,P wave was recognizable in 58%of the animals with a latency of 7.65±0.64 ms and an amplitude of 1.66±0.34 μV when recorded from the neck extensor muscle,and in 50%of the animals with a latency of 7.65±0.64 ms and an amplitude of 0.31±0.28 μV when recorded from the masseter muscle.Conclusion:VEMP can be induced from both neck extensor and masseter muscles in the miniature pig and rat.For a given species,the site of recording affects P wave induction rate and amplitude but not latency.Consistency and repeatability analysis suggests that the masseter muscle is a better recording site in miniature pigs while the cervical extensor is a better recording site in rats.For a given recording site,both latency and amplitude of the P wave are slightly greater in miniature pigs than in rats. 展开更多
关键词 Vestibular evoked myogenic potentials Miniature pigs RATS Masseter muscle Cervical extensor muscle
下载PDF
Vestibular evoked myogenic potentials in patients with diabetes mellitus 被引量:1
14
作者 Ali Bayram 《Journal of Otology》 CSCD 2019年第3期89-93,共5页
Although the exact mechanism and most involved region of the vestibular system have not yet been fully clarified, vestibular dysfunction has been demonstrated in patients with diabetes mellitus (DM). Vestibular evoked... Although the exact mechanism and most involved region of the vestibular system have not yet been fully clarified, vestibular dysfunction has been demonstrated in patients with diabetes mellitus (DM). Vestibular evoked myogenic potential (VEMP) is a short latency electromyographic response to sound or vibration stimuli that may reflect otolith organ or related reflex functions. Since its first description in 1992, VEMP has become a significant part of the vestibular test battery as an objective measurement tool. In diabetic patients, VEMP responses have been studied in order to determine any otolith organ or related reflex dysfunctions. Here, we review the literature with regard to VEMP findings representing any peripheral vestibular end-organ dysfunction in patients with DM. Distinctive vestibular end-organ impairments seem to be demonstrated in patients with DM either with or without DNP via objective vestibular testing tools including VEMP recordings according to relevant studies. However, further studies with larger sample sizes are required to reveal the more definitive findings of VEMP recordings regarding the vestibular pathologies in patients with DM. 展开更多
关键词 Diabetes MELLITUS VESTIBULAR diseases Cervical VESTIBULAR evoked MYOGENIC potentials OCULAR VESTIBULAR evoked MYOGENIC potentials
下载PDF
Brainstem auditory evoked potentials in patients with delayed encephalopathy after acute carbon monoxide poisoning 被引量:1
15
作者 王夏红 肖波 +5 位作者 顾仁骏 肖岚 羊毅 郝以辉 王妮妮 尹景岗 《Journal of Medical Colleges of PLA(China)》 CAS 2006年第5期316-320,共5页
Objective:To evaluate the changes of brainstem auditory evoked potential (BAEP) in patients with delayed encephalopathy after acute carbon monoxide poisoning. Methods: BAEPs were performed in 32 controls and 40 patien... Objective:To evaluate the changes of brainstem auditory evoked potential (BAEP) in patients with delayed encephalopathy after acute carbon monoxide poisoning. Methods: BAEPs were performed in 32 controls and 40 patients. Wave Ⅰ , Ⅱ , Ⅲ ,Ⅳ, Ⅴ latencies and Ⅰ-Ⅲ , Ⅲ-Ⅴ , Ⅰ-Ⅴ interpeak latencies were measured, respectively. Results: Abnormalities of BAEPs in 13 patients (13/40, 32 %). Among the13 abnormal BAEPs, 3 displayed prolongation of latency to waves in one side, no potential in another side; 5 displayed a similar abnormality which was bilateral prolongation of latency to waves ;and another 5 displayed unilateral latency delay. Compared wave Ⅰ , Ⅱ , Ⅲ , Ⅳ, Ⅴ latencies and Ⅰ-Ⅲ , Ⅲ-Ⅴ , Ⅰ-Ⅴ interpeak latencies in the patients and the controls, there were no significant differences (P>0.05). Conclusion: BAEPs can be used for evaluating the diagnostic and prognostic values in the cases of delayed encephalopathy after acute carbon monoxide poisoning. 展开更多
关键词 BRAINSTEM AUDITORY evoked potentials delayed ENCEPHALOPATHY carbon MONOXIDE POISONING
下载PDF
Evaluation of ocular and cervical vestibular evoked myogenic potentials in a conductive hearing loss model 被引量:1
16
作者 Peng Han Rui Zhang +4 位作者 Zichen Chen Ying Gao Ying Cheng Qing Zhang Min Xu 《Journal of Otology》 CSCD 2016年第4期-,共6页
Objective:To investigate the effects of conductive hearing loss (CHL) on vestibular evoked myogenic potentials (VEMPs) using a simulated CHL model, and to provide the basis for future studies. Methods:Twenty-one healt... Objective:To investigate the effects of conductive hearing loss (CHL) on vestibular evoked myogenic potentials (VEMPs) using a simulated CHL model, and to provide the basis for future studies. Methods:Twenty-one healthy subjects were recruited in this study. We measured ocular VEMPs (oVEMPs) and cervical VEMPs (cVEMPs) in these subjects by air-conduction sound (ACS) stimulation. CHL was simulated later by blocking the right external auditory canal with a soundproof earplug to evaluate its impacts on VEMPs. Subjects' responses before simulated CHL served as the control, and were compared to their responses following simulated CHL. Results: oVEMPs following simulated CHL showed decreased response rate, elevated thresholds, attenuated amplitudes and prolonged N1 latencies compared with those before simulated CHL, and the differences were statistically significant. Similarly, cVEMPs following simulated CHL also showed decreased response rate, elevated thresholds and attenuated amplitudes, with prolonged P1 latencies compared with those before simulated CHL, although only differences in response rate, threshold and amplitude were significant. Conclusions:Conductive hearing loss affects the response rate and other response parameters in oVEMPs and cVEMPs. 展开更多
关键词 Conductive hearing loss Ocular vestibular evoked myogenic potentials (oVEMPs) Cervical vestibular evoked myogenic potentials (cVEMPs) MODEL Vestibular function
下载PDF
Characteristics of brainstem auditory evoked potentials of students studying folk dance 被引量:1
17
作者 Yunxiang Li Yuzhen Zhu 《Neural Regeneration Research》 SCIE CAS CSCD 2008年第2期225-228,共4页
BACKGROUND: Previous experiments have demonstrated that brainstem auditory evoked potential is affected by exercise, exercise duration, and frequency. OBJECTIVE: Comparing the brainstem auditory evoked potential of ... BACKGROUND: Previous experiments have demonstrated that brainstem auditory evoked potential is affected by exercise, exercise duration, and frequency. OBJECTIVE: Comparing the brainstem auditory evoked potential of students studying folk dance to students studying other subjects. DESIGN: Observational contrast study. SETTING: Physical Education College, Shandong Normal University PARTICIPANTS: Fifty-five female students were enrolled at Shandong Normal University between September and December in 2005, including 21 students that studied folk dance and 34 students that studied other subjects. The age of the folk dance students averaged (19 ± 1) years and dance training length was (6.0 ± 1.5) years. The students that studied other subjects had never taken part in dance training or other physical training, and their age averaged (22 ± 1) years, body height averaged (162 ± 5) cm, body mass averaged (51 ± 6) kg. All subjects had no prior ear disease or history of other neurological disorders. All students provided informed consent for the experimental project. METHODS: The neural electricity tester, NDI-200 (Shanghai Poseidon Medical Electronic Instrument Factory) was used to examine and record Brainstem Auditory Evoked Potential values of the subjects during silence, as well as to transversally analyze the Brainstem Auditory Evoked Potential values. The electrode positions were cleaned and degreased with soapy water, followed by ethanol. The selected bipolar electrodes were situated on the head: recording electrodes were placed at the Baihui acupoint, and the reference electrode was placed at the mastoid of the measured ear, with grounding electrodes in the center of the forehead. Brainstem Auditory Evoked Potential values were elicited by monaural stimulation of a "click" though an earphone; the other ear was sheltered by the white noise. The click intensity was 102 db, the stimulation frequency was 30 Hz, the bandpass filters were 1 000-3 000 Hz, the sensitivity was 5 ta V, and a total of 2 000 sweeps were averaged. Waveform identification and analysis: various components of the Brainstem Auditory Evoked Potential values were identified, and the peak latencies and peak-peak values were analyzed. MAIN OUTCOME MEASURES: Latency of Ⅰ , Ⅱ, Ⅲ, Ⅳ, Ⅴ and Peak-Peak Value of Ⅰ, Ⅲ, Ⅴwere measured. RESULTS: Fifty-five subjects were enrolled in the final analysis, without any loss. Compared to the students who studied other subjects ① Ⅰ -Ⅴ peak latencies (PL): Ⅳ PL of the right ear of the folk dance students was obviously longer (P 〈 0.05); ② Ⅰ, Ⅲ, V peak-peak values:Ⅰ peak-peak values of the right ear were obviously higher (P 〈 0.05). CONCUSION: ① PL of the right ear of the folk dance students was obviously longer, which indicates that dancing results in a stronger sensibility to auditory stimuli. ②. Peak-peak values were obviously higher, which indicates that long-term exercise enhances the music senses and synchrony of auditory nerve impulses. 展开更多
关键词 brainstem auditory evoked potential peak latency peak-peak value folk dance
下载PDF
Clinical application of electrically evoked compound action potentials 被引量:1
18
作者 Fei Ji Ke Liu Shi-ming Yang 《Journal of Otology》 2014年第3期117-121,共5页
ECAPs are the summary of multiple neurons’ spikes which could be recorded by a bidirectional stimulation-recording system via the cochlear implant,with the artifact elimination paradigms of forward-masking subtractio... ECAPs are the summary of multiple neurons’ spikes which could be recorded by a bidirectional stimulation-recording system via the cochlear implant,with the artifact elimination paradigms of forward-masking subtraction paradigm or alternating polarity paradigm.Three kinds of FDA approved cochlear implants support ECAP testing.This article is to summarize the clinical application of ECAP lest.ECAP test after insertion of electrode during implant operation has been widely used during cochlear implant surgery.In recent years.ECAP thresholds are also used to estimate the T levels and C levels helping programming.However,correlation between ECAP thresholds and psychophysical thresholds is affected by many factors.So far,ECAPs cannot yet be a good indicator of post-operative hearing and speech performance. 展开更多
关键词 Electrically evoked Compound Action potentials Cochlear implant ELECTROPHYSIOLOGY HEARING Intra-operative monitoring
下载PDF
Short-duration transient visual evoked potentials and color reflectivity discretization analysis in glaucoma patients and suspects 被引量:1
19
作者 Michael Waisbourd Rebekah H.Gensure +7 位作者 Ardalan Aminlari Sonya B.Shah Nitasha Khanna Neil Sood Jeanne Molineaux Alberto Gonzalez Jonathan S.Myers L.Jay Katz 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第2期254-261,共8页
AIM: To evaluate the use of short-duration transient visual evoked potentials(VEP) and color reflectivity discretization analysis(CORDA) in glaucomatous eyes,eyes suspected of having glaucoma,and healthy eyes.MET... AIM: To evaluate the use of short-duration transient visual evoked potentials(VEP) and color reflectivity discretization analysis(CORDA) in glaucomatous eyes,eyes suspected of having glaucoma,and healthy eyes.METHODS: The study included 136 eyes from 136 subjects: 49 eyes with glaucoma,45 glaucoma suspect eyes,and 42 healthy eyes.Subjects underwent Humphrey visual field(VF) testing,VEP testing,as well as peripapillary retinal nerve fiber layer optical coherence tomography imaging studies with post-acquisition CORDA applied.Statistical analysis was performed using means and ranges,ANOVA,post-hoc comparisons using Turkey's adjustment,Fisher's Exact test,area under the curve,and Spearman correlation coefficients.RESULTS: Parameters from VEP and CORDA correlated significantly with VF mean deviation(MD)(P〈0.05).In distinguishing glaucomatous eyes from controls,VEP demonstrated area under the curve(AUC) values of 0.64-0.75 for amplitude and 0.67-0.81 for latency.The CORDA HR1 parameter was highly discriminative for glaucomatous eyes vs controls(AUC=0.94).CONCLUSION: Significant correlations are found between MD and parameters of short-duration transient VEP and CORDA,diagnostic modalities which warrant further consideration in identifying glaucoma characteristics. 展开更多
关键词 short-duration transient visual evoked potentials optical coherence tomography color reflectivity discretization analysis GLAUCOMA
下载PDF
The mechanisms underlying long-term potentiation of C-fiber evoked field potentials in spinal dorsal horn 被引量:7
20
作者 LIU Xian-Guo 《生理学报》 CAS CSCD 北大核心 2008年第5期653-663,共11页
Long-term potentiation(LTP) of C-fiber evoked field potentials in spinal dorsal horn is first reported in 1995.Since then,the mechanisms underlying the long-lasting enhancement in synaptic transmission between primary... Long-term potentiation(LTP) of C-fiber evoked field potentials in spinal dorsal horn is first reported in 1995.Since then,the mechanisms underlying the long-lasting enhancement in synaptic transmission between primary afferent C-fibers and neurons in spinal dorsal horn have been investigated by different laboratories.In this article,the related data were summarized and discussed. 展开更多
关键词 脊髓 电位 临床分析 神经纤维
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部