Exploration of Construction Organization for Maintenance of Steam Turbine Equipment in Thermal Power Plants
1
作者 Zhu Yang 《Journal of Electronic Research and Application》 2024年第4期148-153,共6页
The continuous development of the power industry has had a positive impact on thermal power plants,helping them maintain a good production form.In the use of steam turbine equipment in thermal power plants,to prolong ... The continuous development of the power industry has had a positive impact on thermal power plants,helping them maintain a good production form.In the use of steam turbine equipment in thermal power plants,to prolong its lifespan and avoid safety hazards,it is necessary to pay attention to strengthening maintenance and construction organization,better implementing effective organizational work,and effectively applying steam turbine equipment to ensure the sustainable development of thermal power plants.This article discusses the concept of equipment maintenance from the perspective of steam turbine equipment in thermal power plants,analyzes the current situation of equipment maintenance,and proposes a specific construction organization to provide a reference for steam turbine equipment maintenance. 展开更多
关键词 Thermal power plant Steam turbine equipment Construction organization
下载PDF
Analysis and Online Diagnosis on Plugging Fault of Servo Valve in Electro-hydraulic Regulating System of Steam Turbine 被引量:6
2
作者 WANG Xuanyin LI Xiaoxiao LI Fushang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2009年第2期233-237,共5页
Through the study on the output signals of the electro-hydraulic regulating system in the thermal power plant, a novel method for online diagnosis of the plugging fault in the servo valve is presented. With the use of... Through the study on the output signals of the electro-hydraulic regulating system in the thermal power plant, a novel method for online diagnosis of the plugging fault in the servo valve is presented. With the use of the AMESIM software, the changes of the piston displacement, the oil pressure, the magnitude attenuation and the phase lag of the system under different plugging states are studied after simulation. Besides, the influences of the symmetrical and unsymmetrical plugging on the system are also compared and the characteristic table is given. The duo-neural network is put forward to achieve an online diagnosis on the plugging fault of the servo valve. The first level of network helps to make the qualitative diagnosis of the plugging position while the second level is for the quantitative diagnosis of the degree of the plugged position. The research results show that plugging at different positions exerts different influences on the performance of the system. The unsymmetrical plugging mainly affects the regulation time while the symmetrical plugging leads to great changes in the magnitude attenuation and the phase lag. 展开更多
关键词 steam turbine regulating system plugging diagnosis AMESIM software
下载PDF
Optimum Tilt Angle of Flow Guide in Steam Turbine Exhaust Hood Considering the Effect of Last Stage Flow Field 被引量:4
3
作者 Lihua CAO Aqiang LIN +1 位作者 Yong LI Bin XIAO 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2017年第4期866-875,共10页
Abstract Heat transfer and vacuum in condenser are influenced by the aerodynamic performance of steam tur- bine exhaust hood. The current research on exhaust hood is mainly focused on analyzing flow loss and optimal d... Abstract Heat transfer and vacuum in condenser are influenced by the aerodynamic performance of steam tur- bine exhaust hood. The current research on exhaust hood is mainly focused on analyzing flow loss and optimal design of its structure without consideration of the wet steam condensing flow and the exhaust hood coupled with the front and rear parts. To better understand the aerodynamic performance influenced by the tilt angle of flow guide inside a diffuser, taking a 600 MW steam turbine as an example, a numerical simulator CFX is adopted to solve compressible three-dimensional (3D) Reynolds time-aver- aged N-S equations and standard k-e turbulence model. And the exhaust hood flow field influenced by different tilt angles of flow guide is investigated with consideration of the wet steam condensing flow and the exhaust hood coupled with the last stage blades and the condenser throat. The result shows that the total pressure loss coefficient and the static pressure recovery coefficient of exhaust hood change regularly and monotonously with the gradual increase of tilt angle of flow guide. When the tilt angle of flow guide is within the range of 30~ to 40~, the static pressure recovery coefficient is in the range of 15.27% to 17.03% and the total pressure loss coefficient drops to approximately 51%, the aerodynamic performance of exhaust hood is significantly improved. And the effectiveenthalpy drop in steam turbine increases by 0.228% to 0.274%. It is feasible to obtain a reasonable title angle of flow guide by the method of coupling the last stage and the condenser throat to exhaust hood in combination of the wet steam model, which provides a practical guidance to flow guide transformation and optimal design in exhaust hood. 展开更多
关键词 Steam turbine Exhaust hood Last stageblades Tilt angle of flow guide Aerodynamicperformance
下载PDF
Modeling and Optimization of the Steam Turbine Network of an Ethylene Plant 被引量:4
4
作者 李泽秋 赵亮 +1 位作者 杜文莉 钱锋 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2013年第5期520-528,共9页
In this paper,we developed a hybrid model for the steam turbines of a utility system,which combines an improved neural network model with the thermodynamic model.Then,a nonlinear programming(NLP) model of the steam tu... In this paper,we developed a hybrid model for the steam turbines of a utility system,which combines an improved neural network model with the thermodynamic model.Then,a nonlinear programming(NLP) model of the steam turbine network is formulated by utilizing the developed steam turbine models to minimize the total steam cost for the whole steam turbine network.Finally,this model is applied to optimize the steam turbine network of an ethylene plant.The obtained results demonstrate that this hybrid model can accurately estimate and evaluate the performance of steam turbines,and the significant cost savings can be made by optimizing the steam turbine network operation at no capital cost. 展开更多
关键词 hybrid model steam turbine network utility system economic objective
下载PDF
Vibrations measurements for shrouded blades of steam turbines based oneddy current sensors with high frequency response 被引量:4
5
作者 YE De-chao DUAN Fa-jie +3 位作者 ZHOU Qi CHENG Zhong-hai LI Xu NIU Guang-yue 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第4期315-321,共7页
With the development of power plants towards high power and intelligent operation direction,the vibrations or failures of blades,especially the last stage blades in steam turbines,happen more frequently due to the uns... With the development of power plants towards high power and intelligent operation direction,the vibrations or failures of blades,especially the last stage blades in steam turbines,happen more frequently due to the unstable operating conditions brought by flexible operation.A vibration measuring method for the shrouded blades of a steam turbine based on eddy current sensors with high frequency response is proposed,meeting the requirements of non-contact heath monitoring.The eddy current sensors produce the signals which are related to the area changing of every blade’s shroud resulting from the rotation of stator.Then an improved blade tip timing(BTT)technique is proposed to detect the vibrations of shrouded blades by measuring the arrival time of each area changing signal.A structure of eddy current sensors is developed in steam turbines and an amplitude modulation/demodulation circuit is designed to improve the response bandwidth up to 250 kHz.Vibration tests for the last stage blades of a steam turbine were carried out and the results validate the efficiency of the improved BTT technique and the high frequency response of the eddy current sensors presented. 展开更多
关键词 steam turbine blade vibration measurement eddy current sensor blade tip timing
下载PDF
Research on new type of fast-opening mechanism in steam turbine regulating system and optimization of operation tactic 被引量:2
6
作者 Xiao-xiao LI Xuan-yin WANG Fu-shang LI 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第5期633-639,共7页
With the analysis on regulating system in 200 MW steam turbine, the necessity of appending the fast-opening function to the original system is set forth and a new type of fast-opening mechanism is devised. The mathema... With the analysis on regulating system in 200 MW steam turbine, the necessity of appending the fast-opening function to the original system is set forth and a new type of fast-opening mechanism is devised. The mathematical model of system is built up. With the use of AMESIM software, the displacement curve of the piston, the force curve of the cartridge valve spool, the pressure curve and the flux curve in the regulation process are obtained based on simulation. The performances of three fast-opening systems composed of cartridge valves with different diameters are compared. Based on the analysis on factors that affect the execution time of fast-opening, the dead zone of the fast-opening system is put forward. To overcome the defect, dif- ferent operation modes are adopted for different zones. The result shows that with the increase of the valve diameter, the regulating time in the dead zone significantly exceeds the fast-opening time in the whole journey. Accordingly, the optimization operation tactic in the dead zone and the qualification conditions are brought forward. The fast-opening system composed of 32 mm cartridge valves is taken as an example with use of the tactic. The simulation result shows that the maximum regulating time is shortened by 509 ms. 展开更多
关键词 Steam turbine Fast-opening Regulating system AMESIM
下载PDF
Exergy Analysis and Thermal Optimization of a Double-Turbine Regeneration System in a Ultra-Supercritical Double-Reheat Unit 被引量:2
7
作者 Shidan Chi Tao Luan +2 位作者 Yan Liang Xundong Hu Yan Gao 《Fluid Dynamics & Materials Processing》 EI 2021年第1期71-80,共10页
Improving the primary steam parameters is one of the most direct ways to improve the cycle efficiency of a powergeneration system. In the present study, the typical problem connected to the excessively high superheat ... Improving the primary steam parameters is one of the most direct ways to improve the cycle efficiency of a powergeneration system. In the present study, the typical problem connected to the excessively high superheat degree ofextraction steam in an ultra-supercritical (USC) double-reheat unit is considered. Using a 1000 MW power plantas an example, two systems (case 1 and case 2) are proposed, both working in combination with a regenerativesteam turbine. The thermal performances of these two systems are compared with that of the original systemthrough a heat balance method and an exergy balance strategy. The results reveal that the two coupled systemscan significantly reduce the superheat degree of extraction steam, turbine heat rate, and coal consumption of theunit and improve the energy utilization efficiency. These results will provide useful theoretical guidance to futureinvestigators wishing to address the general problem relating to energy conservation and modelling of the coupledextraction steam regenerative system of USC double-reheat units. 展开更多
关键词 Ultra-supercritical unit exergy loss thermal performance regenerative steam turbine superheat degree
下载PDF
Correlation Dimension in Fault Diagnosis of 600 MW Steam Turbine Generator 被引量:2
8
作者 姚宝恒 杨霞菊 +1 位作者 佟德纯 陈兆能 《Journal of Donghua University(English Edition)》 EI CAS 2005年第1期31-36,共6页
GP algorithm of correlation dimension computation is ameliorated which overcomes the shortage of traditional one. Improved process of GP algorithm takes the influence of temporal correlative pairs of points on correla... GP algorithm of correlation dimension computation is ameliorated which overcomes the shortage of traditional one. Improved process of GP algorithm takes the influence of temporal correlative pairs of points on correlation dimension into account and promotes the computational efficiency prominently. Iterative SVD method is applied to remove the influence of noise on the result of correlation dimension. The faults of steam flow turbulence and oil film disturbance which occur in 600 MW Steam Turbine Generator are analyzed and whose correlation dimensions are computed. More distinct quantitative index than FFT is gained to distinguish two faults and it’s of little importance to apply correlation dimension to study the influence of various factors on steam flow turbulence fault for nonexistence of convergent floor in correlation integral curve, which presents a new way to learn the operational function of large capacity steam turbine generator and carry out comprehensive condition monitoring. 展开更多
关键词 correlation dimension ameliorated algorithm 600 MW steam turbine generator air turbulence oil film disturbance.
下载PDF
Finite Element Analysis of Steam Turbine Diaphragm 被引量:1
9
作者 CHEN Jun-ping YANG Guang-hui YANG Bin 《Computer Aided Drafting,Design and Manufacturing》 2014年第4期60-63,共4页
Thediaphragmofsteam turbine isoneofthemainpartsofthepassageunitfor air flowing.For studying its working conditionand performance, the three-dimensionalfinite element model(FEM)with thesoftware ANSYS10.0 isestablishe... Thediaphragmofsteam turbine isoneofthemainpartsofthepassageunitfor air flowing.For studying its working conditionand performance, the three-dimensionalfinite element model(FEM)with thesoftware ANSYS10.0 isestablished according to theactualworking parameters. With the model, the deformation resultsand stress field resultsare analyzed andthe maximum displacement and stress value are calculated, meanwhile,theircorrespondingpositions are found. It provides a good foundationfor solving the problem inproduction. 展开更多
关键词 DIAPHRAGM steam turbine ANSYS finite element model SMITH
下载PDF
2D-simulation of wet steam flow in a steam turbine with spontaneous condensation
10
作者 SUN Lan-xin ZHENG Qun LIU Shun-long 《Journal of Marine Science and Application》 2007年第2期59-63,共5页
Removal of condensates from wet steam flow in the last stages of steam turbines significantly promotes stage efficiency and prevents erosion of rotors. In this paper, homogeneous spontaneous condensation in transonic ... Removal of condensates from wet steam flow in the last stages of steam turbines significantly promotes stage efficiency and prevents erosion of rotors. In this paper, homogeneous spontaneous condensation in transonic steam flow in the 2-D rotor-tip section of a stage turbine is investigated. Calculated results agree with experimental data reasonably well. On the basis of the above work, a 2-D numerical simulation of wet steam flow in adjacent root sections of a complex steam turbine stage was carded out. Computational results were analyzed and provide insights into effective removal of humidity. 展开更多
关键词 steam turbine wet steam flow homogenous condensation Eulerian-Eulerian multiphase model
下载PDF
Influences of attack angle and mach number on aerodynamic characters of typical sections of extra-long blade in a steam turbine
11
作者 杨其国 韩万金 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2007年第4期474-479,共6页
On super-sonic or trans-sonic planar cascade wind tunnel of free jet intermittent type, wind blowing experiments were performed on the typical sections of stator and rotor blades in the last stage of ultra-ultra-criti... On super-sonic or trans-sonic planar cascade wind tunnel of free jet intermittent type, wind blowing experiments were performed on the typical sections of stator and rotor blades in the last stage of ultra-ultra-critical steam turbine with extra-long blade of 1200mm. The influences of attack angle and Mach number on the aerodynamic performances of these sections of the blade profiles were verified, and their operating ranges were also specified. 展开更多
关键词 ultra-ultra-critical steam turbine extra-long blade attack angle and mach number typical section experimental investigation
下载PDF
Application of new techniques to renovation of 200 MW steam turbine
12
作者 陈浮 宋彦萍 王仲奇 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2001年第4期344-347,共4页
Presents the new techniques leading to the improvements in aerodynamics of 200MW steam turbine high pressure cylinder and mid pressure cylinder, discusses the rear loaded profile and blade bowing, and concludes from n... Presents the new techniques leading to the improvements in aerodynamics of 200MW steam turbine high pressure cylinder and mid pressure cylinder, discusses the rear loaded profile and blade bowing, and concludes from numerical simulation and experimental results that the application of rear loaded profile and blade bowing has improved the performance of 200 MW unit. 展开更多
关键词 200 MW steam turbine rear loaded profile blade bowing
下载PDF
Steam turbine rotor crack detection using sifting process of EMD and B-spline wavelet on the interval element model
13
作者 Chen Xuefeng Yang Zhibo +2 位作者 Li Bing Zi Yanyang He Zhengjia 《Engineering Sciences》 EI 2013年第1期10-14,22,共6页
A high-precision identification method for steam turbine rotor crack is presented. By providing me nrst three measured natural frequencies, contours for the specified natural frequency are plotted in the same coordi- ... A high-precision identification method for steam turbine rotor crack is presented. By providing me nrst three measured natural frequencies, contours for the specified natural frequency are plotted in the same coordi- nate, and the intersection of the three curves predicts the crack location and size. The cracked rotor system is mod- eled using B-spline wavelet on the interval (BSWI) finite element method, and a method based on empirical mode decomposition (EMD) and Laplace wavelet is implemented to improve the identification precision of the first three measured natural frequencies. Compared with the classical nondestructive testing, the presented method shows its effectiveness and reliability. It is feasible to apply this method to the online health monitoring for rotor structure. 展开更多
关键词 steam turbine rotor crack detection EMD wavelet finite element method
下载PDF
New type steam turbine for cogeneration
14
作者 He Jianren Yang Qiguo Xu Damao 《Engineering Sciences》 EI 2010年第3期81-84,共4页
A concept of energy saving & efficiency improving from cold source for cogeneration steam turbine was discussed herein. A new type "NCB" cogeneration steam turbine was proposed,which could considerably i... A concept of energy saving & efficiency improving from cold source for cogeneration steam turbine was discussed herein. A new type "NCB" cogeneration steam turbine was proposed,which could considerably increase heat supply capacity,thermal efficiency and electric power. Taking 300 MW cogeneration steam turbine as an example,the results show that heat supply capacity reaches the maximum,i.e. increases by 30 %,thermal efficiency is improved by 12 %,and electric power is enhanced by 15 MW during peak heat load. 展开更多
关键词 cold source new type cogeneration steam turbine energy saving emission reducing economic effect
下载PDF
Performance Analysis and Retrofit on 350-MW China-Made Supercritical Steam Turbines
15
作者 Qin Jianzhu 《Electricity》 2012年第2期37-42,共6页
In this paper the development status and background of 350-MW China-made supercritical steam turbines are introduced.Through the study on the eight turbines that are put into operation,their technical performances are... In this paper the development status and background of 350-MW China-made supercritical steam turbines are introduced.Through the study on the eight turbines that are put into operation,their technical performances are compared and summarized.The major factors affecting the heat consumption rate are analyzed in details and the technical measures to reduce the heat consumption rate are put forward.These measures have been applied to several such units with significant improvements,which can provide important references for the maintenance and retrofit of 350-MW super critical steam turbines. 展开更多
关键词 350-MW SUPERCRITICAL steam turbine performance RETROFIT
下载PDF
Hangzhou Steam Turbine Power(Group)Co.Ltd
16
《China's Foreign Trade》 1996年第11期71-71,共1页
The Hangzhou Steam Turbine Power(Group) Co. Ltd (HSTPC) wastransformed into a corporation solelyowned by the state and put into operation inJune 1995. achieving a sales income of overRMB 260 million in the same year (... The Hangzhou Steam Turbine Power(Group) Co. Ltd (HSTPC) wastransformed into a corporation solelyowned by the state and put into operation inJune 1995. achieving a sales income of overRMB 260 million in the same year (11.59%up from the previous year) and pretax profitsof RMB 41.5 million (a 7.68% increase overthe previous year), of which RMB 21.5 millionwere profits (an increase of 18.44% over theprevious year). The leading product of theHSTPC -- the industrial steam turbine -- 展开更多
关键词 Hangzhou Steam turbine Power Group)Co.Ltd
下载PDF
Forced Compressed Air Cooling System for a 300 MW Steam Turbine in Waigaoqiao Power Plant
17
作者 Sun Shixiong Hua Hong Shanghai Waigaoqiao Thermal Power Plant 《Electricity》 1996年第4期22-24,共3页
The 300 MW steam turbine installed in Waigaoqiao Power Plant with combined HPIP cylinders of double casing structure is a product of the Shanghai Turbine Works utilizing licensed technology. It has a large heat storag... The 300 MW steam turbine installed in Waigaoqiao Power Plant with combined HPIP cylinders of double casing structure is a product of the Shanghai Turbine Works utilizing licensed technology. It has a large heat storage capacity and good thermal insulation, so the metal temperature of first stage of HP cylinder (FSMTI) may reach 400-450℃ after shut down and it takes 7-8 days to cool to 150℃ by natural cooling, Now with a forced cooling system the cooling time may be reduced to 40 hours, so that the turbine may be opened for repair work in about 5-6 days. The cooling system for #2 unit and test procedure are briefly described below. 展开更多
关键词 der Forced Compressed Air Cooling System for a 300 MW Steam turbine in Waigaoqiao Power Plant ITI 认认 TEST 司卜 月卜 HP IP 一基
下载PDF
Optimization Study of Steam Turbine Cold End Parameters
18
作者 Chen Jiangong Northwest Electric Power Design Institute 《Electricity》 1996年第3期32-35,共4页
A lot of study has been made for the design and defining hot end initial parameters of steem turbine of large thermal power plant at home and abroad. But little study has been performed for the reasonable selection of... A lot of study has been made for the design and defining hot end initial parameters of steem turbine of large thermal power plant at home and abroad. But little study has been performed for the reasonable selection of some cold end parameters of steam turbine. The steam turbine cold end parameters defined in actual engineering project are somewhat unreasonable frequently. This paper describes some opinions for selecting some of the steam turbine cold end parameters, especially that of the turbine design back pressure and low pressure cylinder last stage blade length based on the regional features of meteorological conditions in China in association with the optimization of thermal power plant circulating water system. 展开更多
关键词 Optimization Study of Steam turbine Cold End Parameters LENGTH
下载PDF
Strength Analysis of Steam Turbine Diaphragm with a Crack
19
作者 CHEN Jun-ping ZHAO Wei-dong +3 位作者 CAI Wen-he DONG Shu-qing YANG Guang-hui YANG Bin 《Computer Aided Drafting,Design and Manufacturing》 2015年第1期52-55,共4页
The diaphragm of steam turbine is one of the main parts of the passage unit for air flowing and the diaphragm of steam turbine is generally made by welding, but during the course of welding, some cracks often have hap... The diaphragm of steam turbine is one of the main parts of the passage unit for air flowing and the diaphragm of steam turbine is generally made by welding, but during the course of welding, some cracks often have happened, these cracks threaten safety production on the spot, so it is necessary to analyze the strength of steam turbine diaphragm with a crack. For studying its working condition and performance with a crack, the three-dimensional finite element model (FEM) with the software ANSYS 10.0 is established according to the actual working parameters. With the model, the deformation results and stress field results are analyzed and the maximum displacement and stress value are calculated, meanwhile, the maximum stress change with crack depth of steam turbine diaphragm is analyzed. It provides a good foundation for solving the problem in production. 展开更多
关键词 DIAPHRAGM steam turbine ANSYS finite element model CRACK
下载PDF
A Diagnosis Method of Vibration Fault of a Steam Turbine Based on Information Entropy and Grey Correlation Analysis
20
作者 CHEN Fei HUANG Shu-hong ZHANG Yan-ping GAO Wei YANG Tao 《International Journal of Plant Engineering and Management》 2009年第4期206-211,共6页
The vibration fault, one of the common faults in the steam turbine generator unit, brings great damage to the production and the running process. It is well known that the information entropy is to describe the degree... The vibration fault, one of the common faults in the steam turbine generator unit, brings great damage to the production and the running process. It is well known that the information entropy is to describe the degree of indeterminacy of the system, so the information entropy can be used to measure Despite its efficiency, one kind of information entropy is just enabled to identify make up for this limitation, based on nalysis was studied for vibration fault the vibration condition of the unit. certain part of the faults. In order to the faulty signals collected from the rotor test platform, the grey correlation adiagnosis of steam turbine shafting in this paper. The reference faulty matrix and the calculation model of grey correlation degree was established based on three kinds of information entropy. The analysis shows that grey correlation analysis is a useful method for fault diagnosis of shafting and can be used as a quantitative index for fault diagnosis. 展开更多
关键词 steam turbine vibration fault diagnosis information entropy grey correlation analysis