Shaking table test and numerical analysis of a 1:12 scale model of a special concentrically braced steel frame with pinned connections 被引量:7
1
作者 Yu Haifeng Zhang Wenyuan +1 位作者 Zhang Yaochun Sun Yusong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2010年第1期51-63,共13页
This paper describes shaking table tests of a 1:12 scale model of a special concentrically braced steel frame with pinned connections, which was fabricated according to a one-bay braced frame selected from a typical ... This paper describes shaking table tests of a 1:12 scale model of a special concentrically braced steel frame with pinned connections, which was fabricated according to a one-bay braced frame selected from a typical main factory building of a large thermal power plant. In order to investigate the seismic performance of this type of structure, several ground motion accelerations with different levels for seismic intensity Ⅷ, based on the Chinese Code for Seismic Design of Buildings, were selected to excite the model. The results show that the design methods of the members and the connections are adequate and that the structural system will perform well in regions of high seismicity. In addition to the tests, numerical simulations were also conducted and the results showed good agreement with the test results. Thus, the numerical model is shown to be accurate and the beam element can be used to model this structural system. 展开更多
关键词 concentrically braced steel frame pinned connections shaking table test numerical analysis seismic performance
下载PDF
Steel rings as seismic fuses for enhancing ductility of cross braced frames 被引量:2
2
作者 Farhad Behnamfar Saeid Arman Hassan Zibasokhan 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第4期1103-1117,共15页
A new remedy is proposed in this study to increase the ductility of cross-braced frames to a level comparable with ductile moment frames.The suggested system consists of one or two concentric steel rings installed in ... A new remedy is proposed in this study to increase the ductility of cross-braced frames to a level comparable with ductile moment frames.The suggested system consists of one or two concentric steel rings installed in the cross-braced bay vertically.The steel rings are designed such that they fail in bending sooner than failure of the braces in compression.Then the rings act as seismic fuses with multiple bending plastic hinges.Using nonlinear static analysis,it is shown that the proposed system can be designed to behave like cross-braced frames with regard to stiffness and strength,and like special moment frames with regard to ductility.Seismic design factors for the proposed system are recommended based on nonlinear pushover and cyclic analysis studies. 展开更多
关键词 cross brace special moment frame steel ring seismic fuse DUCTILITY
下载PDF
Peak displacement patterns for the performance-based seismic design of steel eccentrically braced frames 被引量:1
3
作者 Ali Fakhraddini Hamed Saffari Mohammad Javad Fadaee 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2019年第2期379-393,共15页
Performance-based seismic design(PBSD) aims to assess structures at different damage states. Since damage can be directly associated to displacements, seismic design with consideration of displacement seems to be logi... Performance-based seismic design(PBSD) aims to assess structures at different damage states. Since damage can be directly associated to displacements, seismic design with consideration of displacement seems to be logical. In this study, simple formulae to estimate the peak floor displacement patterns of eccentrically braced frames(EBFs) at different performance levels subjected to earthquake ground motions are proposed. These formulae are applicable in a PBSD and especially in direct displacement-based design(DDBD). Parametric study is conducted on a group of 30 EBFs under a set of 15 far field and near field accelerograms which they scaled to different amplitudes to adapt various performance levels. The results of thousands of nonlinear dynamic analyses of EBFs have been post-processed by nonlinear regression analysis in order to recognize the major parameters that influence the peak displacement pattern of these frames. Results show that suggested displacement patterns have relatively good agreement with those acquired by an exact nonlinear dynamic analysis. 展开更多
关键词 performance-based SEISMIC DESIGN direct displacement-based DESIGN DISPLACEMENT pattern eccentrically braced FRAMES steel building
下载PDF
Conceptual study of X-braced frames with different steel grades using cyclic half-scale tests
4
作者 Parviz Ebadi Saeid Sabouri-Ghomi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2012年第3期313-329,共17页
In this paper, an experimental and analytical study of two half-scale steel X-braced flames with equal nominal shear strength under cyclic loading is described. In these tests, all members except the braces are simila... In this paper, an experimental and analytical study of two half-scale steel X-braced flames with equal nominal shear strength under cyclic loading is described. In these tests, all members except the braces are similar. The braces are made of various steel grades to monitor the effects of seismic excitation. Internal stiffeners are employed to limit the local buckling and increase the fracture life of the steel bracing. A heavy central core is introduced at the intersection of the braces to decrease their effective length. Recent seismic specifications are considered in the design of the X-braced frame members to verify their efficiency. The failure modes of the X-braced frames are also illustrated. It is observed that the energy dissipation capacity, ultimate load capacity and ductility of the system increase considerably by using lower grade steel and proposed detailing. Analytical modeling of the specimens using nonlinear finite element software supports the experimental findings. 展开更多
关键词 BRACING low grade steel EXPERIMENTATION cyclic test seismic behavior analytical modeling DUCTILITY
下载PDF
Optimization of design parameters for controlled rocking steel braced dual-frames
5
作者 Sobhan Ghasemi M.Firoozi Nezamabadi +1 位作者 Abdolreza S.Moghadam Mahmood Hosseini 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第4期1053-1068,共16页
A controlled rocking concentrically steel braced frame(CR-CSBF)is introduced as an alternative to conventional methods to prevent major structural damage during large earthquakes.It is equipped with elastic post-tensi... A controlled rocking concentrically steel braced frame(CR-CSBF)is introduced as an alternative to conventional methods to prevent major structural damage during large earthquakes.It is equipped with elastic post-tensioned(PT)cables and replaceable devices or fuses to provide overturning resistance and dissipate energy,respectively.Although CR-CSBFs are not officially legalized in globally valid codes for new buildings,it is expected to be presented in them in the near future.The main goal of this study is to determine the optimal design parameters consist of the yield strength and modulus of elasticity of the fuse,the initial force of the PT cable,and the gravity load on the rocking column,considering different heights of the frame,spanning ratios and ground motion types for dual-configuration CR-CSBF.Nonlinear time-history analyses are performed in OpenSees.This study aims to define the optimal input variables as effective design parameters of CR-CSBFs by comparing four seismic responses consisting of story drift,roof displacement,roof acceleration and base shear,and also using the Euclidean metric optimization method.Despite the previous research,this study is innovative and first of its kind.The results demonstrate that the optimal design parameters are variable for various conditions. 展开更多
关键词 self-centering rocking steel braced frame design parameters OPTIMIZATION low damage
下载PDF
Seismic response of high-rise steel framed buildings with Chevron-braced designed according to Venezuelan codes
6
作者 Ronald Ugel Juan Carlos Vielma +2 位作者 Reyes Herrera Sigrit Perez Alex Barbat 《Natural Science》 2012年第8期694-698,共5页
The object of this study is to determine the seismic response of regular high-rise steel buildings with chevron-braced frames. Mechanics models of three buildings of 14, 18 and 20 stories are studied, all of them with... The object of this study is to determine the seismic response of regular high-rise steel buildings with chevron-braced frames. Mechanics models of three buildings of 14, 18 and 20 stories are studied, all of them with similar geometric characteristics in plant and elevation. These models are realized using prescriptions and parameters from venezuelan design codes. The seismic action is carry on through varius synthetic design spectrum compatible accelerograms defined by the seismic codes in this study, with three levels of intensity corresponding to three specific Limit States. Dynamic analysis is used to compute parameters of ductility, over strength and maximum displacements. From these results it can be concluded that chevron-braced frames presented a good overall performance and non V-braced frames show greater damage due to dynamic actions, validating non linear dynamic analysis as a very powerful tool to seismic-resistance design and chevron-braced frames as a very useful choice in improving the response of tall steel structures. since this lateral bracing system is absent from Venezuelan seismic codes. 展开更多
关键词 Framed steel BUILDINGS CHEVRON braced FRAMES Non Linear Analysis Over Strength SEISMIC Response
下载PDF
Behavior of ductile steel X-braced RC frames in seismic zones
7
作者 Eber Alberto Godínez-Domínguez Arturo Tena-Colunga 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2019年第4期845-869,共25页
A satisfactory ductile performance of moment-resisting reinforced concrete concentric braced frame structures (RC-MRCBFs) is not warranted by only following the provisions proposed in Mexico’s Federal District Code (... A satisfactory ductile performance of moment-resisting reinforced concrete concentric braced frame structures (RC-MRCBFs) is not warranted by only following the provisions proposed in Mexico’s Federal District Code (MFDC-04). The nonlinear behavior of low to medium rise ductile RC-MRCBFs using steel X-bracing susceptible to buckling is evaluated in this study. The height of the studied structures ranges from 4 to 20 stories and they were located for design in the lakebed zone of Mexico City. The design of RC-MRCBFs was carried out considering variable contribution of the two main lines of defense of the dual system (RC columns and steel braces). In order to observe the principal elements responsible for dissipating the earthquake input energy, yielding mappings for diff erent load-steps were obtained using both nonlinear static and dynamic analyses. Some design parameters currently proposed in MFDC-04 as global ductility capacities, overstrength reduction factors and story drifts corresponding to diff erent limit states were assessed as a function of both the considered shear strength and slenderness ratios for the studied RC-MRCBFs using pushover analyses. Additionally, envelopes of response maxima of dynamic parameters were obtained from the story and global hysteresis curves. Finally, a brief discussion regarding residual drifts, residual drift ratios, mappings of residual deformations in steel braces and residual rotations in RC beams and columns is presented. From the analysis of the obtained results, it is concluded that when a suitable design criterion is considered, good structural behavior of RC-MRCBFs with steel-X bracing can be obtained. It is also observed that the shear strength balance has an impact in the height-wise distribution of residual drifts, and an important “shake-down” eff ect is obtained for all cases. There is a need to improve design parameters currently proposed in MFDC to promote an adequate seismic performance of RC-MRCBFs. 展开更多
关键词 RC braced-frames seismic design nonlinear dynamic analyses steel-X BRACING OVERSTRENGTH collapse mechanism story DRIFTS residual DRIFTS
下载PDF
Seismic behavior of concrete filled steel tubular arch structures 被引量:4
8
作者 熊峰 Sashi K Kunnath 刘浩吾 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2005年第1期107-115,共9页
Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and ... Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and Shanghai artificial wave were adopted as the input excitation. The entire test process can be divided into three stages depending on the lateral brace configurations, i.e., fully (five) braced, two braces removed, and all braces removed. A total of 46 tests, starting from the elastic state to failure condition, have been conducted. The natural vibration frequencies, responses of acceleration, displacement and strain were measured. From the test results, it is demonstrated that the CFT arch structures are capable of resisting severe ground motions and that CFT arches offer a credible alternative to reinforced concrete arches, especially in regions of high seismic intensity. 展开更多
关键词 concrete filled steel tube arch structures shaking table test seismic behavior lateral braces
下载PDF
Mechanical compression release device in steel bracing system for retrofitting RC frames 被引量:3
9
作者 H. Ghaffarzadeh M.R. Maheri 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2006年第1期151-158,共8页
The development of an innovative structural system with satisfactory seismic performance of braced systems is an important and challenging area of interest in structural engineering. In this paper, a device that can r... The development of an innovative structural system with satisfactory seismic performance of braced systems is an important and challenging area of interest in structural engineering. In this paper, a device that can release the compressive force in the bracing members is developed, and its performance is evaluated. For comparison, four steel braced RC frames were constructed and tested under reverse cyclic loads. Two of them had different amounts of bracing and the other two had the same amount of bracing but incorporated different type of device, called compression release device, which is developed and described in this paper. It can be concluded from the test results that the newly developed device can effectively be used in steel braced systems to prevent buckling failure of the bracing members. Therefore, the device enhances the ductility of brace-framed systems by allowing an adequate capacity for energy dissipation. 展开更多
关键词 reinforced concrete steel bracing cyclic load BUCKLING ductility testing
下载PDF
Effectiveness of two conventional methods for seismic retrofit of steel and RC moment resisting frames based on damage control criteria 被引量:3
10
作者 Seyed Bahram Beheshti Aval Hamed Sadegh Kouhestani Lida Mottaghi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第3期537-555,共19页
This study investigates the efficiency of two types of rehabilitation methods based on economic justification that can lead to logical decision making between the retrofitting schemes. Among various rehabilitation met... This study investigates the efficiency of two types of rehabilitation methods based on economic justification that can lead to logical decision making between the retrofitting schemes. Among various rehabilitation methods, concentric chevron bracing(CCB) and cylindrical friction damper(CFD) were selected. The performance assessment procedure of the frames is divided into two distinct phases. First, the limit state probabilities of the structures before and after rehabilitation are investigated. In the second phase, the seismic risk of structures in terms of life safety and financial losses(decision variables) using the recently published FEMA P58 methodology is evaluated. The results show that the proposed retrofitting methods improve the serviceability and life safety performance levels of steel and RC structures at different rates when subjected to earthquake loads. Moreover, these procedures reveal that financial losses are greatly decreased, and were more tangible by the application of CFD rather than using CCB. Although using both retrofitting methods reduced damage state probabilities, incorporation of a site-specific seismic hazard curve to evaluate mean annual occurrence frequency at the collapse prevention limit state caused unexpected results to be obtained. Contrary to CFD, the collapse probability of the structures retrofitted with CCB increased when compared with the primary structures. 展开更多
关键词 steel and RC moment resisting frames seismic retrofitting collapse probability concentric chevron bracing(CCB) cylindrical friction damper (CFD)
下载PDF
Seismic performance testing of reinforcement concrete frames strengthened with Y-eccentrically brace
11
作者 王大鹏 YU An-lin XUE Li-ming 《Journal of Chongqing University》 CAS 2012年第4期151-160,共10页
Two single-storey single-span reinforcement concrete (RC) frame structures strengthened with Y-eccentrically brace were designed and manufactured to be 1/3 scale. The pseudo-dynamic testing method was used to study ... Two single-storey single-span reinforcement concrete (RC) frame structures strengthened with Y-eccentrically brace were designed and manufactured to be 1/3 scale. The pseudo-dynamic testing method was used to study the mechanical characteristics and the seismic performance under E1-Centro earthquake action with different peak acceleration adjusted by China's Code for Seismic Design of Buildings. The test results indicate that RC frame structures strengthened with Y- eccentrically steel brace present perfect seismic performance under strong earthquake action owing to the good ductility, strong bearing capability and fine energy absorbing capability provided by energy dissipation element and high lateral stiffness provided by diagonal braces. The seismic performance is also affected by the length of outsourcing steel at the joint between energy dissipation element of eccentric steel brace and RC frame beam. The joint should be considerably designed to make sure that shear failure can firstly occur in energy dissipation element. 展开更多
关键词 Y-eccentrically steel brace energy dissipation element pseudo-dynamic test seismic performance shear failure
下载PDF
Determination Method on Initial Pretension of Cables in Steel Mega Frame and Prestressed Composite Bracing Structure
12
作者 唐柏鉴 王飞 顾盛 《Journal of Donghua University(English Edition)》 EI CAS 2013年第6期455-460,共6页
Determining initial pretension values of pre-stressed cables is one of the key problems for a steel mega frame and pre-stressed composite bracing structure.Through the mechanical analysis of the composite bracing unde... Determining initial pretension values of pre-stressed cables is one of the key problems for a steel mega frame and pre-stressed composite bracing structure.Through the mechanical analysis of the composite bracing under vertical loading,the critical factors deciding the initial pretention value were found.According to these factors,a rule for the initial pretension value was put forward.The determination equations were acquired based on the principle of force equilibrium at nodes.The numerical results indicate that the internal force disequilibrium in composite bracings resulted from symmetrical load can be eliminated only in a symmetrical way,so that initial pretention values are decided only by vertical loads.The influencing coefficient leveling method,taking into account interactions between story and story,is accurate and feasible. 展开更多
关键词 pre-stressed steel structure mega frame composite bracing initial presention influencin coefllcient levelinf method
下载PDF
Steel Tower Design for 500 kV Power Line in Indonesia
13
作者 Wei Sunyan Yang Yuanchun 《Electricity》 1997年第4期40-41,共2页
This paper briefly introduces the designand test of steel towers for 500 kV power linein Indonesia by our Institute. It specifiesdesign criteria, tower configurationarrangement and constitution, calculationand analysi... This paper briefly introduces the designand test of steel towers for 500 kV power linein Indonesia by our Institute. It specifiesdesign criteria, tower configurationarrangement and constitution, calculationand analysis of steel towers and the tests onthree prototypes. Experience obtained fromthis work, together with some opinions on theapplication of American "Guide for Designof Steel Transmission Towers", is presented. 展开更多
关键词 steel TOWER BRACING MEMBER REDUNDANT MEMBER NODAL plate
下载PDF
钢支撑-钢筋混凝土掉层框架结构抗震性能试验研究 被引量:2
14
作者 刘立平 李瑞锋 +2 位作者 殷尧日 李英民 邓飞 《工程力学》 EI CSCD 北大核心 2024年第1期182-192,共11页
为改善坡地钢筋混凝土(RC)掉层框架结构抗侧刚度分布的不均匀性,设计了一栋在上接地层设置钢支撑的RC掉层框架结构,按1/4比例提取其顺坡向中榀框架下部5层子结构为试验对象,开展钢支撑-RC掉层框架拟静力试验,观测试件的破坏过程,并对比R... 为改善坡地钢筋混凝土(RC)掉层框架结构抗侧刚度分布的不均匀性,设计了一栋在上接地层设置钢支撑的RC掉层框架结构,按1/4比例提取其顺坡向中榀框架下部5层子结构为试验对象,开展钢支撑-RC掉层框架拟静力试验,观测试件的破坏过程,并对比RC掉层框架试验所得试件的破坏形态,分析试件滞回性能、延性和刚度退化等抗震性能指标。结果表明:试件的最终破坏是以第4层柱底混凝土压溃,梁端混凝土剥落、底部钢筋断裂,顶层柱顶混凝土剥落为标志。与RC掉层框架试验结果相比,钢支撑-RC掉层框架试件上接地柱的破坏明显减轻,柱端破坏分布也更为均匀,避免了掉层框架结构“半层破坏模式”的出现,改善了结构的耗能和抗地震倒塌能力。但试件上接地层相邻上一层的变形和破坏程度较大,应对该楼层的柱端进行适当的抗震加强;设置钢支撑后,试件的滞回曲线较为饱满,并具有良好的延性(正、负向加载的位移延性系数分别可达5.13、5.69),正负向加载的刚度退化曲线也趋于对称。 展开更多
关键词 掉层框架结构 钢支撑 拟静力试验 抗震性能 破坏模式
下载PDF
钢框架-偏心支撑结构消能梁暗置侧向支撑设计
15
作者 骆顺心 刘旭东 +3 位作者 沈琪 彭林立 刘炳清 熊世树 《建筑技术》 2024年第18期2196-2200,共5页
在钢框架-偏心支撑结构中,针对钢结构住宅等建筑中不能接受常规消能梁侧向支撑的情况,设计了一种在消能梁段端部的楼板内设置型钢连接件及暗梁组成的暗置侧向支撑。有限元模拟分析表明,在规范规定的消能梁段下翼缘侧向水平荷载的作用下... 在钢框架-偏心支撑结构中,针对钢结构住宅等建筑中不能接受常规消能梁侧向支撑的情况,设计了一种在消能梁段端部的楼板内设置型钢连接件及暗梁组成的暗置侧向支撑。有限元模拟分析表明,在规范规定的消能梁段下翼缘侧向水平荷载的作用下,该消能梁暗置侧向支撑能显著减小消能梁的扭转变形和侧向弯曲变形;在考虑消能梁上局部楼板失效的情况下,暗置侧向支撑也能提供消能梁合适的扭转约束刚度。通过某工程的原位静荷载试验,验证了该暗置支撑对消能梁发挥的预期侧向支撑作用。 展开更多
关键词 钢框架-偏心支撑结构 装配式钢结构 消能梁 暗置侧向支撑 静载试验
下载PDF
柱脚不均匀沉降对单斜撑钢井架的影响与治理研究
16
作者 李林 穆德君 +3 位作者 刘勇 李翔宇 阴琪翔 常鸿飞 《煤炭工程》 北大核心 2024年第6期80-88,共9页
长期的荷载作用可能导致矿井井架变形和不均匀沉降,甚至可能引起结构整体倾覆。针对童亭煤矿钢结构单斜撑井架的沉降和受力特点,采用ANSYS有限元软件构建了单斜撑井架结构模型,研究了斜撑基础不均匀沉降对井架结构内力的影响规律,并对... 长期的荷载作用可能导致矿井井架变形和不均匀沉降,甚至可能引起结构整体倾覆。针对童亭煤矿钢结构单斜撑井架的沉降和受力特点,采用ANSYS有限元软件构建了单斜撑井架结构模型,研究了斜撑基础不均匀沉降对井架结构内力的影响规律,并对井架内力受不均匀沉降影响机理进行分析。结果表明:①立架与斜撑间的沉降差值会引起立架C柱底和顶部横梁的应力呈线性增加,对斜撑影响较小;X方向沉降率达到2.04‰时,立架最大应力出现于C柱底,约为148 MPa,低于钢材设计强度的限值。②两斜撑基础间的不均匀沉降对单斜撑井架的不利影响更大,断绳工况下的Y方向沉降率为0.88‰时即发生应力超限破坏,略低于《矿山井架设计标准》中对单斜撑式钢井架斜撑基础间最大1‰的沉降差值限制。③不均匀沉降导致井架内力重分布,井架最大应力值和位移值均随沉降值增大而增大,其中立架C柱和斜撑上下天轮梁为最危险部位。针对井架沉降现状,提出了重点部位的加固和顶升方案,加固后井架内力和变形均大幅降低,静力性能提升30%。 展开更多
关键词 高耸钢结构 单斜撑井架 不均匀沉降 静力性能 治理措施
下载PDF
火灾下LYP160屈曲约束支撑抗震性能研究
17
作者 何文福 李志威 +3 位作者 胡宝琳 胡吴彪 丁振坤 田华 《上海大学学报(自然科学版)》 CAS CSCD 北大核心 2024年第2期318-331,共14页
为研究屈曲约束支撑(buckling-restrained brace,BRB)及其体系在高温工况的抗震性能,对BRB芯材低屈服点LYP160钢材分别进行了常温和高温材料力学性能试验.通过与试验结果比较,建立了BRB热-力耦合精细化有限元分析模型,验证了该模型的准... 为研究屈曲约束支撑(buckling-restrained brace,BRB)及其体系在高温工况的抗震性能,对BRB芯材低屈服点LYP160钢材分别进行了常温和高温材料力学性能试验.通过与试验结果比较,建立了BRB热-力耦合精细化有限元分析模型,验证了该模型的准确性;对火灾下LYP160屈曲约束支撑的温度场、滞回曲线、骨架曲线和耗能能力等性能进行了对比分析;对不同工况(3种火灾工况和常温工况)下8层配置屈曲约束支撑钢框架(BRB structure,BS)和原结构(original structure,OS)分别进行了弹塑性动力时程分析.研究结果表明:3种火灾工况下BS的平均层间位移角较于OS分别降低了30.4%、33.2%和42%;OS柱塑性铰损坏严重,且更多出现在柱上,BS整体损坏程度较OS轻,更为安全可靠. 展开更多
关键词 屈曲约束支撑 低屈服点钢 火灾 有限元 抗震性能
下载PDF
四川大学博物馆结构设计重难点分析研究
18
作者 张蜀泸 姚丽 +1 位作者 张志军 朱思其 《建筑结构》 北大核心 2024年第11期100-106,共7页
四川大学博物馆采用钢框架结构体系,并设置屈曲约束支撑改善结构的抗震性能。介绍了四川大学博物馆的结构设计参数及抗震性能目标。针对结构设计中的重难点,开展了屈曲约束支撑的工作机理分析、框架柱计算长度与穿层柱分析、东侧大悬挑... 四川大学博物馆采用钢框架结构体系,并设置屈曲约束支撑改善结构的抗震性能。介绍了四川大学博物馆的结构设计参数及抗震性能目标。针对结构设计中的重难点,开展了屈曲约束支撑的工作机理分析、框架柱计算长度与穿层柱分析、东侧大悬挑空间的相关分析。利用反应谱分析及时程分析探究了屈曲约束支撑工作机理,分析结果表明,屈曲约束支撑能够有效改善钢结构产生塑性铰的状况,起到保护主体钢框架的作用。针对东侧大悬挑空间的功能要求,设计采用了屋顶桁架结合钢拉杆吊挂东侧大楼梯的结构形式,通过结构防连续倒塌分析、楼板应力分析、楼盖舒适度分析、关键节点有限元分析等确保该部位结构设计安全合理。对整体结构受力机理和薄弱部位进行了研究,提出了重点部位的设计原则和加强措施。 展开更多
关键词 四川大学博物馆 钢框架结构 屈曲约束支撑 性能化设计 空间悬挑 关键节点
下载PDF
新型切口厚壁钢管耗能支撑抗震性能研究及参数分析
19
作者 郑国足 韩建平 《工程力学》 EI CSCD 北大核心 2024年第9期201-213,共13页
为了解决现有金属耗能装置连接复杂或容易发生非预期破坏等问题,提出了一种新型切口厚壁钢管耗能支撑(energy-dissipation brace with notched thick-walled steel tube,EDB-NTWST)。该支撑主要依靠首次提出的切口厚壁钢管(notched thic... 为了解决现有金属耗能装置连接复杂或容易发生非预期破坏等问题,提出了一种新型切口厚壁钢管耗能支撑(energy-dissipation brace with notched thick-walled steel tube,EDB-NTWST)。该支撑主要依靠首次提出的切口厚壁钢管(notched thick-walled steel tube,NTWST)耗能,震后仅需更换NTWST即可完成修复,因而可提高结构震后修复速度。针对切口厚壁钢管的不同布置方式,给出了两种支撑的构造形式,并推导了NTWST简化力学分析方法。通过试验研究,验证了理论计算及数值模拟的准确性。采用参数化分析方法,设计了16个NTWST试件,在单调加载和循环荷载下分别对其进行了有限元分析。结果表明:EDB-NTWST的滞回曲线饱满,变形能力强,延性高,可将损伤集中于NTWST上,能够实现可重复使用的目标;简化力学分析方法与试验结果吻合较好,可用于EDB-NTWST的初步设计;NTWST的力学性能能够通过调整其设计参数进行改变,承载力的提高可通过加大耗能环厚度来实现,增加耗能环的数量可以显著提高其变形能力,增加耗能环的宽度并减小中径,是提高NTWST延性的有效方法。 展开更多
关键词 切口厚壁钢管 耗能支撑 抗震性能 试验研究 有限元分析 ABAQUS
下载PDF
基于多水准的高强钢框架-D形偏心支撑结构层剪力分布研究
20
作者 李慎 丁世豪 +1 位作者 李晓蕾 穆林 《计算力学学报》 CAS CSCD 北大核心 2024年第4期734-741,共8页
高强钢框架GD形偏心支撑结构中耗能梁段采用Q355钢,非耗能构件(即框架梁和柱)采用高强度钢材,形成一种新型结构体系.耗能梁段在结构遭遇罕遇地震时充分发挥塑性变形耗能,保护高强钢框架处于弹性受力状态,高强钢框架GD形偏心支撑结构由... 高强钢框架GD形偏心支撑结构中耗能梁段采用Q355钢,非耗能构件(即框架梁和柱)采用高强度钢材,形成一种新型结构体系.耗能梁段在结构遭遇罕遇地震时充分发挥塑性变形耗能,保护高强钢框架处于弹性受力状态,高强钢框架GD形偏心支撑结构由于在塑性状态下结构刚度发生改变,其层剪力分布模式不再符合基于强度的设计理论,因此,本文研究了高强钢框架GD形偏心支撑结构在多水准地震动状态下的层剪力分布模式.本文设计了四种不同层数(4层,8层,12层和16层)和三种不同耗能梁段长度(900mm,1000mm和1100mm)的高强钢框架GD形偏心支撑结构,输入40条近场脉冲地震和40条远场地震记录,得到结构在多遇地震、设防地震、罕遇地震以及极罕遇地震下的层剪力分布模式,并对罕遇地震下的层剪力分布模式进行参数标定,获取塑性状态下结构的弹塑性侧向力分布状态. 展开更多