To promote the application of green renewable materials in concrete composite slabs(CCSs)and study the flexural behavior of CCSs with different shapes,the bending performances of three CCSs with a SFRRAC base plate,on...To promote the application of green renewable materials in concrete composite slabs(CCSs)and study the flexural behavior of CCSs with different shapes,the bending performances of three CCSs with a SFRRAC base plate,one cast-in-site concrete slab of ordinary concrete and one CCS of ordinary concrete by steel bar truss(as recommended in the technical specification for precast concrete structures in Chinese)were compared through experiments.The carrying capacity,flexural behaviour and bi-directional mechanical properties of the specimens were systematically analyzed from the failure modes,load-deflection curves,load-bar strain curves,load-slip curves and crack distributions.Results show that the bending failure process of CCSs with a SFRRAC base plate is similar to that of the cast-in-site concrete slab of ordinary concrete and CCS of ordinary concrete by steel bar truss,as all of them went through the plastic phase,elastic plastic phase and failure phase with fully developed cracks and deflection.No sudden breakage or horizontal cracking of the connecting interface between the base plate and concrete topping was observed.The shape of the base plate has a major impact on the bearing capacity of the CCS with the SFRRAC base plate.When calculating the ultimate bearing capacity with the plastic yield line theory,the influence of the base plate shape on the plastic yield line position should be taken into account.展开更多
Composite one-way concrete slabs with profiled steel sheeting as permanent formwork are commonly used in the construction industry. The steel sheeting supports the wet concrete of a cast-in-situ reinforced or post-ten...Composite one-way concrete slabs with profiled steel sheeting as permanent formwork are commonly used in the construction industry. The steel sheeting supports the wet concrete of a cast-in-situ reinforced or post-tensioned concrete slab and, after the concrete sets, acts as external reinforcement. In this type of slab, longitudinal shear failure between the concrete and the steel sheeting is the most common type of failure at the ultimate load stage. Design codes require the experimental evaluation of the longitudinal shear capacity of each type of steel decking using full-scale tests. This paper presents the results of the short-term testing up to failure of two types of profiled steel decking that are commonly used in the construction industry in Australia. Fourteen full-scale, simply-supported slabs were tested in four-point bending with shear spans of either span/4 or span/6. Four slabs were tested at age of 28 days and the other 10 slabs were subjected to drying shrinkage and various levels of sustained loads for a period of at least 6 months prior to testing to failure. The effects of creep and drying shrinkage on the load carrying capacity and deformation of the slabs at ultimate loads are presented and discussed. The bond-slip relationship of each slab is determined from the test data and the values of maximum longitudinal shear stress calculated using different methods are described and compared.展开更多
In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, doe...In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, does not provide full interaction of a steel beam and a concrete slab. This changes strain distribution in cross-sections of a composite girder and results in redistribution of internal forces in steel and concrete element. In the paper partial interaction index defined on the basis of a neutral axis position, which can be used for verification of steel-concrete interaction in real bridge structures rather than in specimens is proposed. The range of the index value changes, obtained during load testing of a typical steel-concrete composite beam bridge, is presented. The investigation was carried out on a motorway viaduct, consisting of two parallel structures. During the testing values of strains in girders under static and quasi-static loads were measured. The readings from the gauges were used to determine the index, characterizing composite action of the girders. Results of bridge testing under movable load, changing position along the bridge span is presented and obtained in-situ influence functions of strains and index values are commented in the paper.展开更多
基金The National Natural Science Foundation of China(No.51578446).
文摘To promote the application of green renewable materials in concrete composite slabs(CCSs)and study the flexural behavior of CCSs with different shapes,the bending performances of three CCSs with a SFRRAC base plate,one cast-in-site concrete slab of ordinary concrete and one CCS of ordinary concrete by steel bar truss(as recommended in the technical specification for precast concrete structures in Chinese)were compared through experiments.The carrying capacity,flexural behaviour and bi-directional mechanical properties of the specimens were systematically analyzed from the failure modes,load-deflection curves,load-bar strain curves,load-slip curves and crack distributions.Results show that the bending failure process of CCSs with a SFRRAC base plate is similar to that of the cast-in-site concrete slab of ordinary concrete and CCS of ordinary concrete by steel bar truss,as all of them went through the plastic phase,elastic plastic phase and failure phase with fully developed cracks and deflection.No sudden breakage or horizontal cracking of the connecting interface between the base plate and concrete topping was observed.The shape of the base plate has a major impact on the bearing capacity of the CCS with the SFRRAC base plate.When calculating the ultimate bearing capacity with the plastic yield line theory,the influence of the base plate shape on the plastic yield line position should be taken into account.
文摘Composite one-way concrete slabs with profiled steel sheeting as permanent formwork are commonly used in the construction industry. The steel sheeting supports the wet concrete of a cast-in-situ reinforced or post-tensioned concrete slab and, after the concrete sets, acts as external reinforcement. In this type of slab, longitudinal shear failure between the concrete and the steel sheeting is the most common type of failure at the ultimate load stage. Design codes require the experimental evaluation of the longitudinal shear capacity of each type of steel decking using full-scale tests. This paper presents the results of the short-term testing up to failure of two types of profiled steel decking that are commonly used in the construction industry in Australia. Fourteen full-scale, simply-supported slabs were tested in four-point bending with shear spans of either span/4 or span/6. Four slabs were tested at age of 28 days and the other 10 slabs were subjected to drying shrinkage and various levels of sustained loads for a period of at least 6 months prior to testing to failure. The effects of creep and drying shrinkage on the load carrying capacity and deformation of the slabs at ultimate loads are presented and discussed. The bond-slip relationship of each slab is determined from the test data and the values of maximum longitudinal shear stress calculated using different methods are described and compared.
文摘In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, does not provide full interaction of a steel beam and a concrete slab. This changes strain distribution in cross-sections of a composite girder and results in redistribution of internal forces in steel and concrete element. In the paper partial interaction index defined on the basis of a neutral axis position, which can be used for verification of steel-concrete interaction in real bridge structures rather than in specimens is proposed. The range of the index value changes, obtained during load testing of a typical steel-concrete composite beam bridge, is presented. The investigation was carried out on a motorway viaduct, consisting of two parallel structures. During the testing values of strains in girders under static and quasi-static loads were measured. The readings from the gauges were used to determine the index, characterizing composite action of the girders. Results of bridge testing under movable load, changing position along the bridge span is presented and obtained in-situ influence functions of strains and index values are commented in the paper.