Response of a 2-story test-bed structure for the seismic evaluation of nonstructural systems 被引量:4
1
作者 Siavash Soroushian E. “Manos” Maragakis +3 位作者 Arash E. Zaghi Esmaeel Rahmanishamsi Ahmad M. Itani Gokhan Pekcan 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第1期19-29,共11页
A full-scale, two-story, two-by-one bay, steel braced-frame was subjected to a number of unidirectional ground motions using three shake tables at the UNR-NEES site. The test-bed frame was designed to study the seismi... A full-scale, two-story, two-by-one bay, steel braced-frame was subjected to a number of unidirectional ground motions using three shake tables at the UNR-NEES site. The test-bed frame was designed to study the seismic performance of nonstructural systems including steel-framed gypsum partition walls, suspended ceilings and fire sprinkler systems. The frame can be configured to perform as an elastic or inelastic system to generate large floor accelerations or large inter story drift, respectively. In this study, the dynamic performance of the linear and nonlinear test-beds was comprehensively studied. The seismic performance of nonstructural systems installed in the linear and nonlinear test-beds were assessed during extreme excitations. In addition, the dynamic interactions of the test-bed and installed nonstructural systems are investigated. 展开更多
关键词 seismic design steel braced frame building shake table simulation full scale experiment nonstructuralsystems
下载PDF
Static and Dynamic Analyses of Spliced Column
2
作者 Deepak Kumar Singh 《Sound & Vibration》 EI 2021年第3期253-262,共10页
The analysis of spliced column has been carried out to detect optimum location of providing splices in the column.In the present work,static and dynamic(free vibration)analyses of spliced column have been done by rand... The analysis of spliced column has been carried out to detect optimum location of providing splices in the column.In the present work,static and dynamic(free vibration)analyses of spliced column have been done by randomising the location of splicing.A symmetrical four storey steel framed building has been modelled,analysed and designed for loads(dead,live and earthquake loads)recommended by Indian Codal provisions using Staad.Pro.The critical column at each floor level is identified based on axial force(AF),bending moment(BM)and shear force(SF).The total 16 models of spliced columns have been designed and then modelled in a 3D CAD Design tool(SOLIDWORKS)and then imported in the finite element tool(ANSYSWorkbench 14.0)for detailed analysis.The variation of stress,strain and deflection of the spliced column are shown in the form of contour.Further,the modal analysis is performed to determine the natural frequencies.The results of static and dynamic analyses are compared for each modelled spliced column to obtain the optimum location for providing splices in the column.The dynamic analysis of spliced column is of utmost importance in the region where dynamic loadings like earthquake,cyclones etc.are more frequent,and mere static analysis does not account for the safety of the structure.This study will help the engineers to select directly the optimum size and location of the splices in the column of a steel framed building. 展开更多
关键词 Column splice finite element method natural frequency modal analysis static analysis steel framed building