期刊文献+
共找到1,528篇文章
< 1 2 77 >
每页显示 20 50 100
The Continuum Analytical Method of Steel Frame- Reinforced Concrete Shear Wall Mixed Structure
1
作者 Jian Liu Xiangyun Huang +2 位作者 Guangen Zhou Jiping Hao Zenglin Xing 《Journal of Civil Engineering and Architecture》 2011年第4期368-374,共7页
关键词 钢筋混凝土剪力墙 钢框架梁柱 混合结构 二阶效应 水平荷载 层间位移 接头连接 结构设计
下载PDF
Experimental and analytical study on seismic behavior of steel-concrete multienergy dissipation composite shear walls 被引量:4
2
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Qiao Qiyun Yu Chuanpeng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第1期125-139,共15页
In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is p... In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is proposed. In order to study the multi-energy dissipation behavior and restorability after an earthquake, two stages of low cyclic loading tests were carded out on ten test specimens. In the first stage, test on five specimens with different number of SP deep beams was carried out, and the test lasted until the displacement drift reached 2%. In the second stage, thin SPs were welded to both sides of the five specimens tested in the first stage, and the same test was carried out on the repaired specimens (designated as new specimens). The load-bearing capacity, stiffness, ductility, hysteretic behavior and failure characteristics were analyzed for both stages and the results are discussed herein. Extrapolating from these results, strength calculation models and formulas are proposed herein and simulations using ABAQUS carried out, they show good agreement with the test results. The study demonstrates that SRC columns, SP deep beams, concrete wall and energy dissipation strips cooperate well and play an important role in energy dissipation. In addition, this study shows that the shear wall has good recoverability after an earthquake, and that the welding of thin SP's to repair a deformed wall is a practicable technique. 展开更多
关键词 steel reinforced concrete steel plate deep beam multi energy dissipation composite shear wall seismic behavior
下载PDF
Research on seismic performance of shear walls with concrete filled steel tube columns and concealed steel trusses 被引量:3
3
作者 Cao Wanlin Zhang Jianwei +1 位作者 Dong Hongying Wang Min 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2011年第4期535-546,共12页
In order to further improve the seismic performance of RC shear walls, a new composite shear wall with concrete filled steel tube (CFT) columns and concealed steel trusses is proposed. This new shear wall is a doubl... In order to further improve the seismic performance of RC shear walls, a new composite shear wall with concrete filled steel tube (CFT) columns and concealed steel trusses is proposed. This new shear wall is a double composite shear wall; the first composite being the use of three different force systems, CFT, steel truss and shear wall, and the second the use of two different materials, steel and concrete. Three 1/5 scaled experimental specimens: a traditional RC shear wall, a shear wall with CFT columns, and a shear wall with CFT columns and concealed steel trusses, were tested under cyclic loading and the seismic performance indices of the shear walls were comparatively analyzed. Based on the data from these experiments, a thorough elastic-plastic finite element analysis and parametric analysis of the new shear walls were carried out using ABAQUS software. The finite element results of deformation, stress distribution, and the evolution of cracks in each phase were compared with the experimental results and showed good agreement. A mechanical model was also established for calculating the load-carrying capacity of the new composite shear walls. The results show that this new type of shear wall has improved seismic performance over the other two types of shear wails tested. 展开更多
关键词 shear wall concrete filled steel tube (CFT) concealed steel truss seismic performance experimental research
下载PDF
Analysis on Construction Quality Control Technology of Reinforced Concrete Shear Wall Structure
4
作者 Ting Zhou 《Frontiers Research of Architecture and Engineering》 2018年第4期117-121,共5页
In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wa... In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wall structure, the construction level of reinforced concrete can be continuously improved, the construction quality can be guaranteed, and the construction project can be successfully completed, which is worthy of extensive application and promotion in construction enterprises, thus providing a broader development space for construction enterprises. 展开更多
关键词 REINFORCED concrete shear wall structure Construction QUALITY Control technology
下载PDF
Structural Analysis of a RC Shear Wall by Use of a Truss Model
5
作者 Panagis G. Papadopoulos Periklis E. Lamprou 《Open Journal of Civil Engineering》 CAS 2022年第3期320-352,共33页
Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An itera... Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An iterative method is used. Initially, there are only concrete bars. Repeated structural analyses are performed. After each structural analysis, every concrete bar exceeding tensile strength is replaced by a steel bar. For every concrete bar exceeding compressive strength, first its section area is increased. If this is not enough, a steel bar is placed at the side of it. For every steel bar exceeding tensile or compressive strength, its section area is increased. After the end of every structural analysis, if all concrete and steel bars fall within tensile and compressive strengths, the output data are written and the analysis is terminated. Otherwise, the structural analysis is repeated. As all the necessary conditions (static, elastic, linearized geometric) are satisfied and the stresses of ALL concrete and steel bars fall within the tensile and compressive strengths, the results are acceptable. Usually, the proposed method exhibits a fast convergence in 4 - 5 repeats of structural analysis of the RC Shear Wall. 展开更多
关键词 Reinforced concrete shear wall structural Analysis Truss Model Iterative Method Computer Program Boundary Columns and Beam Grid of Horizontal and Diagonal Reinforcing steel Bars
下载PDF
Static behavior of semi-rigid thin-walled steel-concrete composite beam-to-column joints with bolted partial-depth flush end plate:experimental study
6
作者 郜京峰 张耀春 +2 位作者 王海明 姚淇誉 金路 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第5期91-102,共12页
A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic ... A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints. 展开更多
关键词 SEMI-RIGID thin-walled steel-concrete composite structures beam-to-column joints static behavior experimental study
下载PDF
Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams 被引量:1
7
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Zhang Jianwei Xu Fangfang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期609-624,共16页
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat... A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures. 展开更多
关键词 concrete filled steel tube (CFST) column steel plate (SP) deep beam composite shear wall seismic test calculation and analysis
下载PDF
Shear Behavior of Novel Prestressed Concrete Beam Subjected to Monotonic and Cyclic Loading
8
作者 余芳 姚大立 +1 位作者 贾金青 吴锋 《Transactions of Tianjin University》 EI CAS 2014年第4期257-265,共9页
Prestressed steel ultrahigh-strength reinforced concrete(PSURC) beam is a new type of prestressed concrete beam, which not only has a considerable compressive strength attributed to the ultrahigh strength concrete, bu... Prestressed steel ultrahigh-strength reinforced concrete(PSURC) beam is a new type of prestressed concrete beam, which not only has a considerable compressive strength attributed to the ultrahigh strength concrete, but also ensures a certain degree of ductility at failure due to the existence of structural steel. Five of these beams were monotonically tested until shear failure to investigate the static shear performance including the failure pattern, loaddeflection behavior, shear capacity, shear crack width and shear ductility. The experimental results show that these beams have superior shear capacity, crack control ability and shear ductility. To study the shear performance under repeated overloading, seven PSURC beams were loaded in cyclic test simultaneously. The overall shear performance of cycled beams is similar to that of uncycled beams at low load level but different at high load level. The shear capacity and crack control ability of cycled beams at high load level are reduced, whereas the shear ductility is improved. In addition, the influences of variables including the degree of prestress, stirrup ratio and load level on the shear performance of both uncycled and cycled beams were also discussed and compared, respectively. 展开更多
关键词 预应力混凝土梁 循环加载 抗剪性能 超高强度混凝土 抗剪切性能 抗剪切能力 调和 负荷水平
下载PDF
Structural Retrofitting of Old Illyria Hote
9
作者 Feti Selmani Musa Stavileci 《Journal of Civil Engineering and Architecture》 2013年第12期1507-1513,共7页
关键词 结构体系 改造 钢筋混凝土楼板 亚铁 建筑风格 地下停车场 ETABS 峰值加速度
下载PDF
High-Rise Residential Reinforced Concrete Building Optimisation
10
作者 Haibei Xiong Miguel Angel Hidalgo Calvo 《Open Journal of Civil Engineering》 2015年第4期437-450,共14页
In the last few decades structure optimisation has become a main task in a civil engineering project. As a matter of fact, due to the complexity and particularity of every structure, the great amount of variables and ... In the last few decades structure optimisation has become a main task in a civil engineering project. As a matter of fact, due to the complexity and particularity of every structure, the great amount of variables and design criteria to considerate and many other factors, a general optimisation’s method is not simple to formulate. As a result, this paper focuses on how to provide a successful optimisation method for a particular building type, high-rise reinforced concrete buildings. The optimization method is based on decomposition of the main structure into substructures: floor system, vertical load resisting system, lateral load resisting system and foundation system;then each of the subsystems using the design criteria established at the building codes is improved. Due to the effect of the superstructure optimisation on the foundation system, vertical and lateral load resisting system is the last to be considered after the improvement of floor. Finally, as a case example, using the method explained in the paper, a 30-story-high high-rise residential building complex is analysed and optimised, achieving good results in terms of structural behaviour and diminishing the overall cost of the structure. 展开更多
关键词 structurE Optimisation HIGH-RISE RESIDENTIAL Reinforced concrete Buildings shear-wall structurE Deep PILES Post GROUTING
下载PDF
装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能 被引量:1
11
作者 曹万林 杨兆源 《北京工业大学学报》 CAS CSCD 北大核心 2024年第2期165-179,共15页
为研究装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能,对1个足尺轻钢框架结构试件和3个足尺轻钢框架-轻钢骨架轻混凝土墙板结构试件进行了低周反复荷载下的抗震性能试验及理论分析,试件变量包括:2种装配构造,即内嵌式装配墙板、外... 为研究装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能,对1个足尺轻钢框架结构试件和3个足尺轻钢框架-轻钢骨架轻混凝土墙板结构试件进行了低周反复荷载下的抗震性能试验及理论分析,试件变量包括:2种装配构造,即内嵌式装配墙板、外贴式装配墙板;2种轻钢骨架轻混凝土墙板,即框架式轻钢骨架轻混凝土墙板、桁架式轻钢骨架轻混凝土墙板。研究了各试件的破坏特征和损伤演化过程,分析了结构滞回特性、承载力、变形能力、刚度退化、耗能性能和应变。结果表明:装配式轻钢框架-轻钢骨架轻混凝土墙板结构共同工作性能良好,其水平承载力相比轻钢框架提高了204.7%~210.4%,抗侧刚度提高了257.3%~512.5%,结构变形及耗能能力有显著提高;内嵌墙板的自攻钉连接构造以及外贴墙板的螺栓连接构造传力性能可靠,结构具备2道抗震防线的受力特征;基于简化塑性分析模型以及拉压杆软化桁架模型,对试件承载力进行了计算,计算结果与试验符合较好。 展开更多
关键词 装配式组合结构 轻钢框架 轻钢骨架轻混凝土墙板 抗震性能 低周反复荷载试验 承载力计算
下载PDF
焊接多腔双钢板-混凝土组合剪力墙抗震性能分析 被引量:1
12
作者 丁发兴 蔡勇强 +3 位作者 王莉萍 孙浩 吕飞 黄修文 《华南理工大学学报(自然科学版)》 EI CSCD 北大核心 2024年第1期15-25,共11页
大多数双钢板-混凝土组合剪力墙采用螺栓连接或焊接肋的方式使钢板和混凝土协同工作。然而,这种连接方式可能导致整体性和塑性变形效率较低,且制作复杂,焊接多腔双钢板-混凝土组合剪力墙能够有效地避免这些问题。为了深入研究焊接多腔... 大多数双钢板-混凝土组合剪力墙采用螺栓连接或焊接肋的方式使钢板和混凝土协同工作。然而,这种连接方式可能导致整体性和塑性变形效率较低,且制作复杂,焊接多腔双钢板-混凝土组合剪力墙能够有效地避免这些问题。为了深入研究焊接多腔双钢板-混凝土组合剪力墙的抗震性能,基于约束混凝土真三轴塑性-损伤本构模型和钢材弹塑性混合强化-韧性损伤本构模型,建立了组合剪力墙的精细化三维实体-壳模型,将模拟所得的滞回曲线、骨架曲线、刚度退化曲线、弹性刚度、承载力、累积耗能、等效阻尼粘滞系数和延性系数与已有拟静力试验结果相比较,发现两者吻合较好。分析结果表明:轴压比对组合剪力墙模型算例刚度和承载力的影响较小,而随剪跨比增大,组合剪力墙模型算例的刚度和承载力呈线性降低;轴压比对组合剪力墙模型算例总塑性耗能的影响较小,而剪跨比的影响较大,剪力墙总塑性耗能随剪跨比增大而降低;轴压比和剪跨比都不会改变算例各部件的耗能分配机制,即组合剪力墙模型算例以外钢板和内隔板耗能为主。 展开更多
关键词 双钢板-混凝土组合剪力墙 抗震性能 塑性耗能 有限元分析
下载PDF
钢管混凝土键连接框架梁和剪力墙的受剪性能
13
作者 李明 刘栩邑 +2 位作者 吴潜 吴欣禹 吴永新 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2024年第1期38-46,共9页
目的 研究钢管混凝土键连接框架梁和剪力墙的受剪性能,为工程应用提供设计依据。方法 应用有限元分析软件ABAQUS对比钢管混凝土键连接与现浇连接梁墙的结构受剪性能,分析前者受剪机理及不同因素对受剪性能的影响。结果 钢管混凝土键连... 目的 研究钢管混凝土键连接框架梁和剪力墙的受剪性能,为工程应用提供设计依据。方法 应用有限元分析软件ABAQUS对比钢管混凝土键连接与现浇连接梁墙的结构受剪性能,分析前者受剪机理及不同因素对受剪性能的影响。结果 钢管混凝土键连接梁墙的结构承载力和延性系数较现浇结构分别提高约10%和34%;钢材强度从Q235到Q390,初始刚度增加8.44%;截面高度从100 mm到120 mm,延性系数提高17.73%;截面厚度每增加2 mm,承载力提高约15%;截面长度和混凝土强度等级对承载力、初始刚度和延性系数的影响均小于15%,纵向距离对其受剪性能几乎无影响。结论 采用钢管混凝土键连接梁墙的结构总体受剪性能优于现浇结构;钢材强度和截面厚度分别是影响初始刚度和承载力的主要因素。 展开更多
关键词 钢管混凝土键 框架-剪力墙结构 梁墙试件 抗剪性能 有限元分析
下载PDF
冷弯薄壁型钢-结构防火一体板自攻螺钉连接性能试验研究
14
作者 熊刚 折志伟 +3 位作者 李环宇 石宇 刘宜丰 姜雪 《土木与环境工程学报(中英文)》 CSCD 北大核心 2024年第3期134-143,共10页
开展冷弯薄壁型钢-结构防火一体板自攻螺钉连接抗剪性能试验研究,完成35个典型试件单调拉伸及低周往复加载试验,分析结构防火一体板厚度、螺钉直径、螺钉端距及加载角度等因素对其抗剪性能的影响。结果表明:不同加载角度及螺钉端距的试... 开展冷弯薄壁型钢-结构防火一体板自攻螺钉连接抗剪性能试验研究,完成35个典型试件单调拉伸及低周往复加载试验,分析结构防火一体板厚度、螺钉直径、螺钉端距及加载角度等因素对其抗剪性能的影响。结果表明:不同加载角度及螺钉端距的试件呈现不同的破坏模式,主要包括板材端部撕裂破坏、板材孔壁承压破坏、板材被拉断破坏等,且破坏时试件的自攻螺钉存在不同程度的倾斜。对于试验端分别采用直径为4.8、5.5 mm螺钉的试件,试件的峰值荷载及延性系数与螺钉直径无明显相关性,弹性刚度随着螺钉直径增大而显著提升;随着螺钉端距由15 mm增大至25 mm,试件的弹性刚度无明显变化,而峰值荷载和延性系数提高了约35%;随着板厚由12 mm增大到20 mm,试件的峰值荷载提高了约40%,弹性刚度提高了约90%,延性系数降低了约30%;与加载角度为0°的试件的特征参数相比,加载角度为45°时,试件弹性刚度提高了约100%,峰值荷载及延性系数无明显差别;加载角度为90°时,试件弹性刚度及峰值荷载无明显差别,延性系数降低了约40%。 展开更多
关键词 冷弯薄壁型钢 结构防火一体板 螺钉连接 抗剪性能 低周往复荷载
下载PDF
HPC端部加强双钢板组合剪力墙的抗震性能
15
作者 袁朝庆 李国洋 +2 位作者 代晓辉 房宽光 计静 《黑龙江科技大学学报》 CAS 2024年第1期61-68,共8页
为研究高性能混凝土端部加强双钢板组合剪力墙受力机理及破坏形态,以轴压比、腹部普通混凝土强度等级为关键参数,设计了4片普通试件,7片HPC端部加强试件,运用ABAQUS构建其有限元模型,研究其抗震性能。结果表明:同轴压比下,HPC端部加强... 为研究高性能混凝土端部加强双钢板组合剪力墙受力机理及破坏形态,以轴压比、腹部普通混凝土强度等级为关键参数,设计了4片普通试件,7片HPC端部加强试件,运用ABAQUS构建其有限元模型,研究其抗震性能。结果表明:同轴压比下,HPC端部加强试件相比普通试件屈服荷载提高16.30%,峰值荷载提升13.40%;随着轴压比提高,HPC端部加强试件峰值荷载和屈服荷载分别提高7.22%和2.72%,随着轴压比减小,HPC端部加强试件延性提升22.26%;提高腹部腔体混凝土强度等级,HPC端部加强试件的屈服荷载和峰值荷载分别提高13.01%和11.14%,延性提升16.91%。 展开更多
关键词 HPC端部加强 双钢板组合剪力墙 抗震性能
下载PDF
自攻钉集块连接混凝土复合剪力墙抗震性能试验
16
作者 曹万林 谢晖 +2 位作者 杨兆源 董宏英 刘亦斌 《结构工程师》 2024年第2期136-147,共12页
提出了适用于装配式混凝土复合剪力墙结构的自攻钉集块连接构造,为研究自攻钉集块连接混凝土复合剪力墙的抗震性能,设计制作了3个剪跨比为1.39的足尺剪力墙试件,进行了低周反复荷载试验,主要变量包括自攻钉集块连接构造、自攻钉集块与... 提出了适用于装配式混凝土复合剪力墙结构的自攻钉集块连接构造,为研究自攻钉集块连接混凝土复合剪力墙的抗震性能,设计制作了3个剪跨比为1.39的足尺剪力墙试件,进行了低周反复荷载试验,主要变量包括自攻钉集块连接构造、自攻钉集块与后浇条带组合连接构造以及L形边框构造柱。分析了试件破坏模式、承载力、滞回特性、刚度及退化、变形能力、耗能性能和应变特征等。结果表明:自攻钉集块连接构造装配便捷,受力性能可靠;采用自攻钉集块与后浇条带组合连接构造试件的承载力及刚度相比自攻钉集块连接构造分别提高了8.54%和6.03%;设置L形边框构造柱的试件承载力、刚度及耗能分别提高了67.48%、129.33%和277.93%。自攻钉集块连接复合剪力墙具有良好的抗震性能,满足装配式低层住宅混凝土复合剪力墙结构的抗震设计要求,可用于实际工程。 展开更多
关键词 装配式混凝土结构 复合剪力墙 自攻钉集块连接 抗震性能 试验研究
下载PDF
窄翼缘异形柱-波纹钢板剪力墙体系的抗震性能
17
作者 彭晓彤 刘小荟 +1 位作者 高艺源 林晨 《济南大学学报(自然科学版)》 CAS 北大核心 2024年第3期320-330,共11页
针对钢结构住宅凸梁、凸柱和抗侧刚度不足的问题,提出一种新型窄翼缘异形柱-波纹钢板剪力墙体系;通过与传统H形钢柱-平钢板剪力墙体系进行对比,确定内嵌波纹钢板布置方式,采用ABAQUS软件建立所提出体系的有限元模型,对所提出体系的抗震... 针对钢结构住宅凸梁、凸柱和抗侧刚度不足的问题,提出一种新型窄翼缘异形柱-波纹钢板剪力墙体系;通过与传统H形钢柱-平钢板剪力墙体系进行对比,确定内嵌波纹钢板布置方式,采用ABAQUS软件建立所提出体系的有限元模型,对所提出体系的抗震性能进行分析,探讨外部框架截面形式与布置方式、波纹钢板厚度与剪跨比等对所提出体系的抗侧承载力、耗能能力和塑性变形能力的影响。结果表明:所提出的体系具有较大的抗侧承载力和较强的耗能能力、塑性变形能力,极限抗侧承载力为设计值的1.73倍,具备一定的安全储备;横向布置的波纹钢板能有效减小其作用于框架梁柱的荷载;采用十字形异形柱使所提出的体系有更强的塑性变形能力;所提出体系中的异形柱偏肢宜沿剪力墙面内方向布置,内嵌波纹钢板厚度宜取为3~5 mm,剪跨比宜控制在1.25左右。 展开更多
关键词 装配式钢结构 剪力墙体系 窄翼缘异形柱 波纹钢板 抗震性能
下载PDF
自攻钉集块连接T形边框混凝土肋格复合墙板抗震性能试验
18
作者 曹万林 郝煜 +2 位作者 杨兆源 董宏英 刘亦斌 《结构工程师》 2024年第2期126-135,共10页
研发了混凝土框架(桁架)肋格填充发泡混凝土墙板,提出了T形边框与混凝土肋格复合墙板边肋的自攻钉集块连接构造。设计并制作了2个足尺自攻钉集块连接T形边框混凝土肋格复合墙板试件,包括1个十字形框架肋格墙板试件和1个人字形支撑桁架... 研发了混凝土框架(桁架)肋格填充发泡混凝土墙板,提出了T形边框与混凝土肋格复合墙板边肋的自攻钉集块连接构造。设计并制作了2个足尺自攻钉集块连接T形边框混凝土肋格复合墙板试件,包括1个十字形框架肋格墙板试件和1个人字形支撑桁架肋格墙板试件。进行了低周反复荷载试验,研究了各试件的破坏状态和滞回特性,分析了不同肋格构造对承载力、刚度、变形能力及耗能性能的影响。结果表明:十字形框架肋格墙板试件主要发生了发泡混凝土填充墙板及硬化砂浆面层的剪切开裂,人字形支撑桁架肋格墙板的破坏特征为混凝土桁架支撑的损伤失效;人字形支撑桁架肋格墙板试件的承载力和初始刚度相比十字形框架肋格墙板试件分别提高了74.3%和69.0%;十字形框架肋格墙板试件则具有较高的变形能力和耗能性能;自攻钉集块连接构造连接性能可靠,保证了T形边框与混凝土肋格复合墙板的协同变形。可为工程设计与施工提供参考。 展开更多
关键词 装配式剪力墙结构 混凝土肋格复合墙板 自攻钉集块 抗震性能 试验研究
下载PDF
常泰长江大桥组合索塔锚固结构钢-混传剪构造足尺模型试验研究
19
作者 赵灿晖 王康康 +1 位作者 沈孔健 郑清刚 《桥梁建设》 EI CSCD 北大核心 2024年第1期31-38,共8页
常泰长江大桥索塔锚固结构采用钢箱-核芯混凝土组合结构,为研究该新型组合索塔锚固结构钢-混传剪构造的受力特性,进行钢-混传剪构造足尺模型试验研究。制作2个锚固结构足尺节段试验模型,通过压剪试验研究锚固结构的荷载~滑移曲线及应力... 常泰长江大桥索塔锚固结构采用钢箱-核芯混凝土组合结构,为研究该新型组合索塔锚固结构钢-混传剪构造的受力特性,进行钢-混传剪构造足尺模型试验研究。制作2个锚固结构足尺节段试验模型,通过压剪试验研究锚固结构的荷载~滑移曲线及应力、应变分布等受力特性,并通过有限元模型分析锚固结构的传力机理和各组件的内力分配比例,推导剪力钉剪力计算方法。结果表明:在2.14倍单索最大索力荷载作用下,锚固结构保持弹性状态,钢壁板未产生明显滑移,钢-混界面最大滑移不超过0.25 mm,该锚固结构中钢-混传剪构造至少具有2.14倍的安全系数;荷载作用下,剪力钉剪力从上至下逐渐增大,锚腹板附近底部3排剪力钉剪力较大,钢-混传剪构造至少存在剪力钉和界面摩擦力2种传剪机制,钢-混传剪构造的承载能力显著提高;钢-混传剪构造受力过程分为粘结力传力阶段和局部滑移阶段,剪力钉剪力分布不仅与沿剪切方向长度分布有关,也与荷载的大小线性相关。 展开更多
关键词 斜拉桥 组合索塔锚固结构 钢-混传剪构造 荷载~滑移曲线 足尺模型试验 有限元法
下载PDF
PBL抗剪传力钢筋连接接头受拉力学性能试验
20
作者 龚超 梁梓豪 +4 位作者 张素梅 李孝忠 梁伟桥 闫贵海 姚志东 《哈尔滨工程大学学报》 EI CAS CSCD 北大核心 2024年第7期1391-1399,共9页
装配式混凝土构件间钢筋的连接是其适用性和经济性的关键环节,针对国内工程常用的灌浆套筒和约束浆锚钢筋连接技术存在施工难度大、效率低、质量不易检验等问题,本文提出了PBL-穿孔钢筋连接接头、PBL-穿孔钢管连接接头和PBL-U形钢筋连... 装配式混凝土构件间钢筋的连接是其适用性和经济性的关键环节,针对国内工程常用的灌浆套筒和约束浆锚钢筋连接技术存在施工难度大、效率低、质量不易检验等问题,本文提出了PBL-穿孔钢筋连接接头、PBL-穿孔钢管连接接头和PBL-U形钢筋连接接头3种钢筋连接接头,实现预制混凝土单元间钢筋应力的传递,具有施工简便、质量易保证、成本低等优势。对这3种钢筋接头进行了6组参数共18个钢筋接头试件的拉伸性能试验,研究了新型接头试件的破坏模式、承载力和变形能力等,得到各参数对新型接头拉伸强度的影响规律,并对不同接头的受拉力学性能进行对比分析。研究结果表明:3种钢筋连接接头能够实现钢筋应力的有效传递,验证了新型钢筋连接接头的可行性。 展开更多
关键词 装配式混凝土 钢筋连接接头 PBL剪力键 钢管混凝土 拉伸试验 裂缝发展 破坏模式 受拉承载力
下载PDF
上一页 1 2 77 下一页 到第