期刊文献+
共找到1,381篇文章
< 1 2 70 >
每页显示 20 50 100
Seismic performance evaluation of steel frame-steel plate shear walls system based on the capacity spectrum method 被引量:3
1
作者 Jian-hua SHAO Qiang GU Yong-kang SHEN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第3期322-329,共8页
This paper presents some methods that the standard acceleration design response spectra derived from the present China code for seismic design of buildings are transformed into the seismic demand spectra, and that the... This paper presents some methods that the standard acceleration design response spectra derived from the present China code for seismic design of buildings are transformed into the seismic demand spectra, and that the base shear force-roof displacement curve of structure is converted to the capacity spectrum of an equivalent single-degree-of-freedom (SDOF) system. The capacity spectrum method (CSM) is programmed by means of MATLABT.0 computer language. A dual lateral force resisting system of 10-story steel frame-steel plate shear walls (SPSW) is designed according to the corresponding China design codes. The base shear force-roof displacement curve of structure subjected to the monotonic increasing lateral inverse triangular load is obtained by applying the equivalent strip model to stimulate SPSW and by using the finite element analysis software SAP2000 to make Pushover analysis. The seismic performance of this dual system subjected to three different conditions, i.e. the 8-intensity frequently occurred earthquake, fortification earthquake and seldom occurred earthquake, is evaluated by CSM program. The excessive safety of steel frame-SPSW system designed according to the present China design codes is pointed out and a new design method is suggested. 展开更多
关键词 steel frame-steel plate shear walls (SPSW) system Capacity spectrum method (CSM) Seismic demand spectrum Base shear force-roof displacement Seismic performance evaluation
下载PDF
Study on the Structural Performance of Steel Plate Shear Wall with Slits on Both Sides
2
作者 Yuchen Liu Heesung Kim 《International Journal of Technology Management》 2015年第7期121-123,共3页
This paper presents a new type of two sides slotted steel plate shear wall, and carries on the analysis to the finite element elastic buckling, respectively discusses the critical buckling load and the buckling mode. ... This paper presents a new type of two sides slotted steel plate shear wall, and carries on the analysis to the finite element elastic buckling, respectively discusses the critical buckling load and the buckling mode. For the steel plate shear wall without stiffening ribs on both sides, the paper given the buckling coefficient formula, and give design proposal and reference value of steel plate shear wall with stiffened on both sides. 展开更多
关键词 steel plate shear wall elastic buckling ultimate load-carrying capacity
下载PDF
Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams 被引量:1
3
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Zhang Jianwei Xu Fangfang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期609-624,共16页
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat... A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures. 展开更多
关键词 concrete filled steel tube (CFST) column steel plate (SP) deep beam composite shear wall seismic test calculation and analysis
下载PDF
Lateral load-carrying capacity analyses of composite shear walls with double steel plates and filled concrete with binding bars 被引量:1
4
作者 周德源 刘凌飞 朱立猛 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第8期2083-2091,共9页
A method is developed to predict the lateral load-carrying capacity of composite shear walls with double steel plates and filled concrete with binding bars(SCBs). Nonlinear finite element models of SCBs were establish... A method is developed to predict the lateral load-carrying capacity of composite shear walls with double steel plates and filled concrete with binding bars(SCBs). Nonlinear finite element models of SCBs were established by using the finite element tool, Abaqus. Tie constraints were used to connect the binding bars and the steel plates. Surface-to-surface contact provided by the Abaqus was used to simulate the interaction between the steel plate and the core concrete. The established models could predict the lateral load-carrying capacity of SCBs with a reasonable degree of accuracy. A calculation method was developed by superposition principle to predict the lateral load-carrying capacity of SCBs for the engineering application. The concrete confined by steel plates and binding bars is under multi-axial compression; therefore, its shear strength was calculated by using the Guo-Wang concrete failure criterion. The shear strength of the steel plates of SCBs was calculated by using the von Mises yielding criterion without considering buckling. Results of the developed method are in good agreement with the testing and finite element results. 展开更多
关键词 composite shear wall double steel plate binding bar lateral load-carrying capacity nonlinear finite element analysis
下载PDF
Improving behavior of semi-supported steel plate shear walls
5
作者 Ali GHAMARI Abbas AKBARPOUR Ali GHANBARI 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第10期2891-2905,共15页
In spite of the good performance of the steel plate shear wall(SPSW)in recent earthquakes and experimental studies,the need for huge columns to surround the infill plate is a major shortcoming of the system.This short... In spite of the good performance of the steel plate shear wall(SPSW)in recent earthquakes and experimental studies,the need for huge columns to surround the infill plate is a major shortcoming of the system.This shortcoming can be resolved by using semi-supported SPSW.The semi-supported SPSW has secondary columns that prevent the transfer of stress from the infill plate to the main columns.In spite of extensive experimental and numerical investigations on SPSWs,there are many ambiguities regarding the behavior of the semi-supported SPSW.Although stress in the columns is reduced,incomplete diagonal tension field action is formed in the infill plate that creates new problems.In this paper,a new type of semi-supported SPSW is presented in which the steel plate and the secondary columns are angled.The creation of the angle of the plate and the secondary column makes it possible to use the full capacity of the steel plate as well as the capacity of the secondary columns.Numerical results showed that the wall with a 60°angle has a favorable performance relative to the semi-supported wall.Moreover,with the 60°angle,stiffness,strength and energy absorption is increased.The angle of the secondary columns has little effect on the non-elastic stiffness.Nevertheless,using a wall with an angle of more than 90°can neutralize the wall’s behavior relative to conventional walls.Therefore,the wall with a 60°angle as an optimal angle is recommended. 展开更多
关键词 steel plate shear wall(SPSW) DUCTILITY STIFFNESS ultimate strength R factor
下载PDF
Numerical Analysis of the Structure of High-Strength Double-Layer Steel Plate Concrete Shaft by Drilling Method of Water-Bearing Weak Rock Formation
6
作者 Touogam Touolak Benedicte 《Open Journal of Civil Engineering》 2022年第2期189-207,共19页
In order to ensure the safety of coal mine shaft construction, a double-layer steel plate concrete composite shaft wall structure was proposed. However, fewer studies were conducted on this structure, which made engin... In order to ensure the safety of coal mine shaft construction, a double-layer steel plate concrete composite shaft wall structure was proposed. However, fewer studies were conducted on this structure, which made engineers too confused to fully recognize its feasibility of this structure. Hence, based on the previous experimental research on the Taohutu mine construction project in  Ordos in Inner Mongolia, this research paper aims to provide a widely deep numerical analysis by the usage of the finite element software, in fact, to establish the corresponding numerical analysis model and make a comparison with the experimental data to get the rationality of the verified model. The influence of the composite characteristics of the steel plate and concrete on the ultimate bearing capacity and stress field of the shaft wall structure is studied here through the method of multi-factor analysis. Also, the optimal design scheme of the double-layer steel plate and concrete composite shaft wall structure is proposed in this research paper. 展开更多
关键词 Finite Element Method Double-Layer steel plate Shaft wall structure Taohutu Mine Construction
下载PDF
Experimental and analytical study on seismic behavior of steel-concrete multienergy dissipation composite shear walls 被引量:5
7
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Qiao Qiyun Yu Chuanpeng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第1期125-139,共15页
In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is p... In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is proposed. In order to study the multi-energy dissipation behavior and restorability after an earthquake, two stages of low cyclic loading tests were carded out on ten test specimens. In the first stage, test on five specimens with different number of SP deep beams was carried out, and the test lasted until the displacement drift reached 2%. In the second stage, thin SPs were welded to both sides of the five specimens tested in the first stage, and the same test was carried out on the repaired specimens (designated as new specimens). The load-bearing capacity, stiffness, ductility, hysteretic behavior and failure characteristics were analyzed for both stages and the results are discussed herein. Extrapolating from these results, strength calculation models and formulas are proposed herein and simulations using ABAQUS carried out, they show good agreement with the test results. The study demonstrates that SRC columns, SP deep beams, concrete wall and energy dissipation strips cooperate well and play an important role in energy dissipation. In addition, this study shows that the shear wall has good recoverability after an earthquake, and that the welding of thin SP's to repair a deformed wall is a practicable technique. 展开更多
关键词 steel reinforced concrete steel plate deep beam multi energy dissipation composite shear wall seismic behavior
下载PDF
Structural Analysis of a RC Shear Wall by Use of a Truss Model
8
作者 Panagis G. Papadopoulos Periklis E. Lamprou 《Open Journal of Civil Engineering》 CAS 2022年第3期320-352,共33页
Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An itera... Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An iterative method is used. Initially, there are only concrete bars. Repeated structural analyses are performed. After each structural analysis, every concrete bar exceeding tensile strength is replaced by a steel bar. For every concrete bar exceeding compressive strength, first its section area is increased. If this is not enough, a steel bar is placed at the side of it. For every steel bar exceeding tensile or compressive strength, its section area is increased. After the end of every structural analysis, if all concrete and steel bars fall within tensile and compressive strengths, the output data are written and the analysis is terminated. Otherwise, the structural analysis is repeated. As all the necessary conditions (static, elastic, linearized geometric) are satisfied and the stresses of ALL concrete and steel bars fall within the tensile and compressive strengths, the results are acceptable. Usually, the proposed method exhibits a fast convergence in 4 - 5 repeats of structural analysis of the RC Shear Wall. 展开更多
关键词 Reinforced Concrete shear wall structural Analysis Truss Model Iterative Method Computer Program Boundary Columns and Beam Grid of Horizontal and Diagonal Reinforcing steel Bars
下载PDF
Self-centering steel plate shear walls for improving seismic resilience 被引量:2
9
作者 Patricia M. CLAYTON Daniel M. DOWDEN +4 位作者 Chao-Hsien LI Jeffrey W. BERMAN Michel BRUNEAU Laura N. LOWES Keh-Chuan TSAI 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2016年第3期283-290,共8页
As part of a Network for Earthquake Engineering Simulation research project led by researchers at the University of Washington with collaborators at University at Buffalo, and Taiwan National Center for Research on Ea... As part of a Network for Earthquake Engineering Simulation research project led by researchers at the University of Washington with collaborators at University at Buffalo, and Taiwan National Center for Research on Earthquake Engineering, a self-centering steel plate shear wall (SC-SPSW) system has been developed to achieve enhanced seismic performance objectives, including recentering. The SC-SPSW consists of thin steel infill panels, referred to as web plates that serve as the primary lateral load-resisting and energy dissipating element of the system. Post- tensioned (PT) beam-to-column connections provide system recentering capabilities. A performance-based design procedure has been developed for the SC-SPSW, and a series of nonlinear response history analyses have been conducted to verify intended seismic performance at multiple hazard levels. Quasi-static subassembly tests, quasi-static and shake table tests of scaled three-story specimens, and pseudo-dynamic tests of two full-scale two-story SC-SPSWs have been conducted. As a culmination of this multi-year, multi-institutional project, this paper will present an overview of the SC- SPSW numerical and experimental research programs. This paper will also discuss innovative PT connection and web plate designs that were investigated to improve constructability, resilience, and seismic performance and that can be applied to other self-centering and steel plate shear wall systems. 展开更多
关键词 SELF-CENTERING steel plate shear walls large-scale experiment post-tensioned connections performance-baseddesign
原文传递
Pseudo-dynamic testing of a fabricated composite frame with steel plate shear walls 被引量:3
10
作者 Zheng-gang CAO Peng DU +1 位作者 Feng FAN Zhe-ming CHEN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2017年第6期454-466,共13页
A pseudo-dynamic testing program was generated on a fabricated composite frame with steel plate shear walls (SPSWs) to study its seismic perlbrmance. The specimen was a three-storey single-bay frame, which was compo... A pseudo-dynamic testing program was generated on a fabricated composite frame with steel plate shear walls (SPSWs) to study its seismic perlbrmance. The specimen was a three-storey single-bay frame, which was composed of H- section steel columns and composite beams, and was assembled by bolted height-adjustable steel beam-to-column connections (BHA connections). Beam-only-connected SPSWs were selected as lateral load resisting members. The specimen was subjected to four ground motions of progressively increasing intensity. The results showed that: (1) beam-only-connected S PSWs provided sufficient lateral load resistance, lateral stiffness, and energy dissipation capacity to the fabricated frame via the tension ficld action developed in their infill panels; (2) the fabricated frame, assembled by BHA connections, exhibited substantial redundancy and good ductility; (3) an undesirable failure mode of the fabricated frame, in huge earthquakes, included severe cracking in composite beams and block shear failure in SPSWs' connections; (4) the inter-storey shear force distribution determined by ASCE/SE1 7-10 was verified with experimental data. 展开更多
关键词 Fabricated frame Composite beam steel plate shear walls Pseudo-dynamic test
原文传递
Lateral stiffness of steel plate shear walls 被引量:2
11
作者 NIE JianGuo ZHU Li 《Science China(Technological Sciences)》 SCIE EI CAS 2014年第1期151-162,共12页
The steel plate shear wall system has been used in a number of buildings as an innovative lateral force resistant system.Openings often exist in the steel plate shear walls due to the various functional requirements o... The steel plate shear wall system has been used in a number of buildings as an innovative lateral force resistant system.Openings often exist in the steel plate shear walls due to the various functional requirements of structures.These openings may negatively impact the lateral stiffness of steel plate shear walls.Therefore,an experimental research was instituted to investigate the seismic behavior of steel plate shear walls,with and without openings.The experimental results showed that steel plate shear walls have the satisfying seismic behavior,and,as expected,the strength and stiffness characteristics of the walls were reduced due to openings.Then a single-story wall panel FE model and an analytical deep beam model are developed in order to find the critical factors dominating the thickness reduction coefficient of wall panels with the opening.Furthermore,extensive parametric analysis is conducted to derive a simplified formula for the determination of the thickness reduction coefficient of wall panels with the opening for substituting solid wall panels with reduced thickness for actual wall panels with the opening.Finally,the design method for calculating the lateral stiffness is verified by some experimental programs and recommended for the routine practice of steel plate shear walls. 展开更多
关键词 steel plate shear walls wall panels with the opening thickness reduction coefficient lateral stiffness design method analytical deep beam model
原文传递
Numerical modeling of seismic behavior of ellipse and peanut-shaped auxetic steel plate shear walls
12
作者 Junjie Wang Yazhi Zhu Xiaoning Cai 《Low-carbon Materials and Green Construction》 2023年第1期112-131,共20页
This study proposes a new auxetic-shaped steel plate shear walls(simply referred to as ASSPSWs)consisting of boundary members and built-in perforated infill plates.The connection type between the boundary members is a... This study proposes a new auxetic-shaped steel plate shear walls(simply referred to as ASSPSWs)consisting of boundary members and built-in perforated infill plates.The connection type between the boundary members is a hinge joint.The hole forms on the infill plates include orthogonal ellipse-shaped(ASSPSW-OE)and orthogonal peanutshaped(ASSPSW-OP).This paper studied the hysteretic performance of two steel plate shear walls’types based on the finite element analysis method.Within the study context,a parametric analysis was carried out to investigate the influence of various factors,such as hole size and hole distance,on the seismic performance of steel plate shear walls(SPSWs).The results indicated that reducing the the ratio of the ligament thickness to ellipse major axis(t/D)in orthogonal ellipse-shaped SPSWs can effectively increase the porosity while reducing the bearing and energy dissipation capacities.Under the condition with the t/D unchanged,increasing the ratio of the major to minor axis of the ellipse(d/D)raises the porosity and does not significantly reduce the bearing capacity and energy dissipation capacity of the SPSWs.For orthogonal peanut-shaped SPSWs,the holes’geometrical parameters significantly influence the hysteretic performance.Particularly,with the increase in the radial ratio of large to small circles in a peanut-shaped hole(R/r),the spacing between cells decreases.When drift exceeds 2%,the equivalent viscous damping ratio decreases sharply.Unlike the orthogonal ellipse-shaped SPSWs,changing the arrangement angle of peanut-shaped cells has no significant effect on orthogonal peanut-shaped SPSWs.However,the larger the angle,the greater the out-of-plane buckling of orthogonal ellipse-shaped SPSWs;thus,the energy dissipation capacity is reduced.The similarities lie in that the larger cell arrangement angle will make the steel plates have a complete stress field,and the bearing capacity will be slightly improved.When the cell arrangement angle(θ)is 45°,the SPSWs can develop high initial stiffness. 展开更多
关键词 AUXETICS steel plate shear wall Ellipse shape Peanut shape Cyclic loading Hysteresis response
原文传递
钢管混凝土键连接框架梁和剪力墙的受剪性能 被引量:1
13
作者 李明 刘栩邑 +2 位作者 吴潜 吴欣禹 吴永新 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2024年第1期38-46,共9页
目的 研究钢管混凝土键连接框架梁和剪力墙的受剪性能,为工程应用提供设计依据。方法 应用有限元分析软件ABAQUS对比钢管混凝土键连接与现浇连接梁墙的结构受剪性能,分析前者受剪机理及不同因素对受剪性能的影响。结果 钢管混凝土键连... 目的 研究钢管混凝土键连接框架梁和剪力墙的受剪性能,为工程应用提供设计依据。方法 应用有限元分析软件ABAQUS对比钢管混凝土键连接与现浇连接梁墙的结构受剪性能,分析前者受剪机理及不同因素对受剪性能的影响。结果 钢管混凝土键连接梁墙的结构承载力和延性系数较现浇结构分别提高约10%和34%;钢材强度从Q235到Q390,初始刚度增加8.44%;截面高度从100 mm到120 mm,延性系数提高17.73%;截面厚度每增加2 mm,承载力提高约15%;截面长度和混凝土强度等级对承载力、初始刚度和延性系数的影响均小于15%,纵向距离对其受剪性能几乎无影响。结论 采用钢管混凝土键连接梁墙的结构总体受剪性能优于现浇结构;钢材强度和截面厚度分别是影响初始刚度和承载力的主要因素。 展开更多
关键词 钢管混凝土键 框架-剪力墙结构 梁墙试件 抗剪性能 有限元分析
下载PDF
装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能 被引量:5
14
作者 曹万林 杨兆源 《北京工业大学学报》 CAS CSCD 北大核心 2024年第2期165-179,共15页
为研究装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能,对1个足尺轻钢框架结构试件和3个足尺轻钢框架-轻钢骨架轻混凝土墙板结构试件进行了低周反复荷载下的抗震性能试验及理论分析,试件变量包括:2种装配构造,即内嵌式装配墙板、外... 为研究装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能,对1个足尺轻钢框架结构试件和3个足尺轻钢框架-轻钢骨架轻混凝土墙板结构试件进行了低周反复荷载下的抗震性能试验及理论分析,试件变量包括:2种装配构造,即内嵌式装配墙板、外贴式装配墙板;2种轻钢骨架轻混凝土墙板,即框架式轻钢骨架轻混凝土墙板、桁架式轻钢骨架轻混凝土墙板。研究了各试件的破坏特征和损伤演化过程,分析了结构滞回特性、承载力、变形能力、刚度退化、耗能性能和应变。结果表明:装配式轻钢框架-轻钢骨架轻混凝土墙板结构共同工作性能良好,其水平承载力相比轻钢框架提高了204.7%~210.4%,抗侧刚度提高了257.3%~512.5%,结构变形及耗能能力有显著提高;内嵌墙板的自攻钉连接构造以及外贴墙板的螺栓连接构造传力性能可靠,结构具备2道抗震防线的受力特征;基于简化塑性分析模型以及拉压杆软化桁架模型,对试件承载力进行了计算,计算结果与试验符合较好。 展开更多
关键词 装配式组合结构 轻钢框架 轻钢骨架轻混凝土墙板 抗震性能 低周反复荷载试验 承载力计算
下载PDF
焊接多腔双钢板-混凝土组合剪力墙抗震性能分析 被引量:1
15
作者 丁发兴 蔡勇强 +3 位作者 王莉萍 孙浩 吕飞 黄修文 《华南理工大学学报(自然科学版)》 EI CSCD 北大核心 2024年第1期15-25,共11页
大多数双钢板-混凝土组合剪力墙采用螺栓连接或焊接肋的方式使钢板和混凝土协同工作。然而,这种连接方式可能导致整体性和塑性变形效率较低,且制作复杂,焊接多腔双钢板-混凝土组合剪力墙能够有效地避免这些问题。为了深入研究焊接多腔... 大多数双钢板-混凝土组合剪力墙采用螺栓连接或焊接肋的方式使钢板和混凝土协同工作。然而,这种连接方式可能导致整体性和塑性变形效率较低,且制作复杂,焊接多腔双钢板-混凝土组合剪力墙能够有效地避免这些问题。为了深入研究焊接多腔双钢板-混凝土组合剪力墙的抗震性能,基于约束混凝土真三轴塑性-损伤本构模型和钢材弹塑性混合强化-韧性损伤本构模型,建立了组合剪力墙的精细化三维实体-壳模型,将模拟所得的滞回曲线、骨架曲线、刚度退化曲线、弹性刚度、承载力、累积耗能、等效阻尼粘滞系数和延性系数与已有拟静力试验结果相比较,发现两者吻合较好。分析结果表明:轴压比对组合剪力墙模型算例刚度和承载力的影响较小,而随剪跨比增大,组合剪力墙模型算例的刚度和承载力呈线性降低;轴压比对组合剪力墙模型算例总塑性耗能的影响较小,而剪跨比的影响较大,剪力墙总塑性耗能随剪跨比增大而降低;轴压比和剪跨比都不会改变算例各部件的耗能分配机制,即组合剪力墙模型算例以外钢板和内隔板耗能为主。 展开更多
关键词 双钢板-混凝土组合剪力墙 抗震性能 塑性耗能 有限元分析
下载PDF
联肢弯剪型钢板剪力墙抗震性能试验研究
16
作者 郝际平 兰芮 +6 位作者 田炜烽 薛强 李生辉 樊春雷 徐坤 朱邵辉 王洪臣 《建筑钢结构进展》 CSCD 北大核心 2024年第4期10-19,共10页
联肢钢板剪力墙结构是将2片钢板剪力墙通过钢连梁连接形成的抗侧力结构。通过对1榀1/3缩尺的4层联肢弯剪型钢板剪力墙试件进行低周往复加载试验,从滞回曲线、骨架曲线、延性、承载力及刚度退化、耗能能力等方面研究了该结构体系的抗震性... 联肢钢板剪力墙结构是将2片钢板剪力墙通过钢连梁连接形成的抗侧力结构。通过对1榀1/3缩尺的4层联肢弯剪型钢板剪力墙试件进行低周往复加载试验,从滞回曲线、骨架曲线、延性、承载力及刚度退化、耗能能力等方面研究了该结构体系的抗震性能,并且对试件的屈服顺序和变形模式进行了分析。结果表明:联肢钢板剪力墙试件的延性系数达到5.03,承载力退化系数均大于0.96,承载力和刚度退化稳定,等效黏滞阻尼系数达到0.25以上,表明联肢弯剪型钢板剪力墙具有优越的抗震性能。加载过程中,连梁先于墙板发生屈服,墙板先屈曲后屈服,此后柱脚和横梁相继屈服。连梁的引入改变了结构的屈服机制,提高了整体的延性和耗能能力,能够组成多道抗震防线,且试件整体最终也体现出合理的破坏机制。整体侧移曲线呈弯剪变形模式。该试验研究更加贴合实际工程中联肢钢板剪力墙结构的应用情况,为联肢钢板剪力墙结构的进一步研究和应用提供了试验基础。 展开更多
关键词 联肢钢板剪力墙 低周往复加载试验 抗震性能 屈服机制 变形模式
下载PDF
带PBL剪力键的钢芯板混凝土组合剪力墙低周往复加载试验研究
17
作者 袁涛涛 蔡玉军 +1 位作者 聂少锋 隋璐 《建筑科学与工程学报》 CAS 北大核心 2024年第5期42-51,共10页
为研究带PBL剪力键的钢芯板混凝土组合剪力墙的抗震性能,对1个型钢混凝土组合剪力墙和4个钢芯板混凝土组合剪力墙进行了循环往复加载试验;观察带PBL剪力键的钢芯板混凝土组合剪力墙在水平循环荷载下的破坏全过程,并分析该类剪力墙的滞... 为研究带PBL剪力键的钢芯板混凝土组合剪力墙的抗震性能,对1个型钢混凝土组合剪力墙和4个钢芯板混凝土组合剪力墙进行了循环往复加载试验;观察带PBL剪力键的钢芯板混凝土组合剪力墙在水平循环荷载下的破坏全过程,并分析该类剪力墙的滞回特征、变形能力、承载能力、耗能性能、刚度和强度退化能力。结果表明:钢芯板混凝土组合剪力墙的破坏模式主要为弯曲型破坏,滞回曲线较为饱满;配置钢芯板的剪力墙承载力、延性性能和耗能能力较优;PBL剪力键的构造方式可保证钢芯板与混凝土之间的黏结性能完好,PBL剪力键平放会导致剪力墙出现沿PBL剪力键的水平通缝,影响剪力墙承载能力的发挥,建议采用PBL剪力键竖放的构造形式。 展开更多
关键词 钢芯板混凝土组合剪力墙 PBL剪力键 抗震性能 拟静力试验
下载PDF
低周反复荷载下T型双波纹钢板混凝土组合剪力墙受力性能试验研究
18
作者 陈宗平 莫琳琳 +1 位作者 许新颖 唐际宇 《工程力学》 EI CSCD 北大核心 2024年第6期87-104,共18页
为研究低周反复荷载下T型双波纹钢板混凝土组合剪力墙的受力性能,对5个T型双波纹钢板混凝土组合剪力墙进行了低周反复加载试验。基于试验数据,分析了T型组合剪力墙的破坏模式、滞回曲线、变形能力及耗能能力,重点研究了边缘约束条件、... 为研究低周反复荷载下T型双波纹钢板混凝土组合剪力墙的受力性能,对5个T型双波纹钢板混凝土组合剪力墙进行了低周反复加载试验。基于试验数据,分析了T型组合剪力墙的破坏模式、滞回曲线、变形能力及耗能能力,重点研究了边缘约束条件、波纹类型以及轴压比不同变化参数对T型组合剪力墙抗震性能指标的影响规律。研究结果表明:T型双波纹钢板混凝土组合剪力墙破坏模式主要有压屈破坏和压弯破坏两种;设置边缘约束构件是提高T型双波纹钢板混凝土组合剪力墙承载能力和变形能力的关键因素;纵向窄波纹钢板对内部混凝土的约束能力更强,在低周反复荷载下两者协同工作性更优,而横向窄波纹钢板试件强度退化最严重;采用全截面塑性设计方法进行T型双波纹钢板混凝土组合剪力墙正截面承载力计算,试验值与计算值吻合良好;T型双波纹钢板混凝土组合剪力墙具有较好的承载能力和变形能力,可适用于高层及超高层建筑结构中。 展开更多
关键词 T型组合剪力墙 双波纹钢板 低周反复荷载 钢板类型 承载力计算
下载PDF
冷弯薄壁型钢-结构防火一体板自攻螺钉连接性能试验研究
19
作者 熊刚 折志伟 +3 位作者 李环宇 石宇 刘宜丰 姜雪 《土木与环境工程学报(中英文)》 CSCD 北大核心 2024年第3期134-143,共10页
开展冷弯薄壁型钢-结构防火一体板自攻螺钉连接抗剪性能试验研究,完成35个典型试件单调拉伸及低周往复加载试验,分析结构防火一体板厚度、螺钉直径、螺钉端距及加载角度等因素对其抗剪性能的影响。结果表明:不同加载角度及螺钉端距的试... 开展冷弯薄壁型钢-结构防火一体板自攻螺钉连接抗剪性能试验研究,完成35个典型试件单调拉伸及低周往复加载试验,分析结构防火一体板厚度、螺钉直径、螺钉端距及加载角度等因素对其抗剪性能的影响。结果表明:不同加载角度及螺钉端距的试件呈现不同的破坏模式,主要包括板材端部撕裂破坏、板材孔壁承压破坏、板材被拉断破坏等,且破坏时试件的自攻螺钉存在不同程度的倾斜。对于试验端分别采用直径为4.8、5.5 mm螺钉的试件,试件的峰值荷载及延性系数与螺钉直径无明显相关性,弹性刚度随着螺钉直径增大而显著提升;随着螺钉端距由15 mm增大至25 mm,试件的弹性刚度无明显变化,而峰值荷载和延性系数提高了约35%;随着板厚由12 mm增大到20 mm,试件的峰值荷载提高了约40%,弹性刚度提高了约90%,延性系数降低了约30%;与加载角度为0°的试件的特征参数相比,加载角度为45°时,试件弹性刚度提高了约100%,峰值荷载及延性系数无明显差别;加载角度为90°时,试件弹性刚度及峰值荷载无明显差别,延性系数降低了约40%。 展开更多
关键词 冷弯薄壁型钢 结构防火一体板 螺钉连接 抗剪性能 低周往复荷载
下载PDF
窄翼缘异形柱-波纹钢板剪力墙体系的抗震性能
20
作者 彭晓彤 刘小荟 +1 位作者 高艺源 林晨 《济南大学学报(自然科学版)》 CAS 北大核心 2024年第3期320-330,共11页
针对钢结构住宅凸梁、凸柱和抗侧刚度不足的问题,提出一种新型窄翼缘异形柱-波纹钢板剪力墙体系;通过与传统H形钢柱-平钢板剪力墙体系进行对比,确定内嵌波纹钢板布置方式,采用ABAQUS软件建立所提出体系的有限元模型,对所提出体系的抗震... 针对钢结构住宅凸梁、凸柱和抗侧刚度不足的问题,提出一种新型窄翼缘异形柱-波纹钢板剪力墙体系;通过与传统H形钢柱-平钢板剪力墙体系进行对比,确定内嵌波纹钢板布置方式,采用ABAQUS软件建立所提出体系的有限元模型,对所提出体系的抗震性能进行分析,探讨外部框架截面形式与布置方式、波纹钢板厚度与剪跨比等对所提出体系的抗侧承载力、耗能能力和塑性变形能力的影响。结果表明:所提出的体系具有较大的抗侧承载力和较强的耗能能力、塑性变形能力,极限抗侧承载力为设计值的1.73倍,具备一定的安全储备;横向布置的波纹钢板能有效减小其作用于框架梁柱的荷载;采用十字形异形柱使所提出的体系有更强的塑性变形能力;所提出体系中的异形柱偏肢宜沿剪力墙面内方向布置,内嵌波纹钢板厚度宜取为3~5 mm,剪跨比宜控制在1.25左右。 展开更多
关键词 装配式钢结构 剪力墙体系 窄翼缘异形柱 波纹钢板 抗震性能
下载PDF
上一页 1 2 70 下一页 到第
使用帮助 返回顶部