期刊文献+
共找到3,488篇文章
< 1 2 175 >
每页显示 20 50 100
Seismic behavior of concrete filled steel tubular arch structures 被引量:4
1
作者 熊峰 Sashi K Kunnath 刘浩吾 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2005年第1期107-115,共9页
Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and ... Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and Shanghai artificial wave were adopted as the input excitation. The entire test process can be divided into three stages depending on the lateral brace configurations, i.e., fully (five) braced, two braces removed, and all braces removed. A total of 46 tests, starting from the elastic state to failure condition, have been conducted. The natural vibration frequencies, responses of acceleration, displacement and strain were measured. From the test results, it is demonstrated that the CFT arch structures are capable of resisting severe ground motions and that CFT arches offer a credible alternative to reinforced concrete arches, especially in regions of high seismic intensity. 展开更多
关键词 concrete filled steel tube arch structures shaking table test seismic behavior lateral braces
下载PDF
Bending Resistance of Steel Plate-Reinforced Concrete Beam 被引量:1
2
作者 TIAN Zhimin CHEN Jie 《Transactions of Tianjin University》 EI CAS 2006年第B09期210-213,共4页
The formulas for calculating bending-resistant capacity of a steel plate-reinforced concrete composite beam are derived. To validate the formulas, experiments of the composite beam under three-point bending are carrie... The formulas for calculating bending-resistant capacity of a steel plate-reinforced concrete composite beam are derived. To validate the formulas, experiments of the composite beam under three-point bending are carried out. Calculated results based on the formulas are in good agreement with experimental results. 展开更多
关键词 steel plate-reinforced concrete bending resistance capacity FORMULA EXPERIMENT
下载PDF
Internal Force Distribution in Steel-Concrete Composite Structure for Pylon of Cable-Stayed Bridge 被引量:5
3
作者 蒲黔辉 白光亮 《Journal of Southwest Jiaotong University(English Edition)》 2009年第2期95-101,共7页
Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure... Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure the safety of the steel-concrete composite structure, a stud connector model for the joint section was put forward. Experiments were conducted to obtain the relation between load and slip of specimen, the failure pattern of stud connector, the yield bearing capacity and ultimate bearing capacity of a single stud, etc. The whole process of the structural behavior of the specimen was comprehensively analyzed. The features of the internal force distribution in the steel-concrete composite structure and the strain distribution of stud connector under different loads were emphatically studied. The test results show that the stud connector is applicable for the steel-concrete composite structure for pylon of Jintang bridge. The stud has a good ductility performance and a obvious yield process before its destruction. The stud connector basically works in a state of elasticity under a load less than the yield load. 展开更多
关键词 Stud connector Experimental research steel-concrete composite structure Cable-stayed bridge Internal force distribution
下载PDF
The Continuum Analytical Method of Steel Frame- Reinforced Concrete Shear Wall Mixed Structure
4
作者 Jian Liu Xiangyun Huang +2 位作者 Guangen Zhou Jiping Hao Zenglin Xing 《Journal of Civil Engineering and Architecture》 2011年第4期368-374,共7页
The inter-story drift stiffness considered the semirigidity of beam and column joints connection, and P-Delta second order effect of steel frame parts in the mixed structure is presented in the paper. After considerin... The inter-story drift stiffness considered the semirigidity of beam and column joints connection, and P-Delta second order effect of steel frame parts in the mixed structure is presented in the paper. After considering on the influence of semirigidity between steel beams and steel columns, second order effect of beam-column members for steel frame and structural second order effect, the traditional continuum analytial method used in RC shear-frames wall structure is developed to steel frames-reinforced concrete shear wall mixed structure subject to horizontal load in this paper. A continuum approach, which is suitable for analyzing steel frames-reinforced concrete shear wall mixed structure subject to horizontal load, is presented. The method is relatively simple and more practical. It will be referred to structural design for steel frames-reinforced concrete shear wall mixed structure. 展开更多
关键词 steel frames-reinforced concrete wall mixed structure continuum analytial approach inter-story drift stiffness semirigid connection second order effect.
下载PDF
Discrete Numerical Study on Type II Fracture of Partially Detached Concrete Panels in Cold Region
5
作者 Huayi Zhang Maobin Song +2 位作者 Lei Shen Nizar Faisal Alkayem Maosen Cao 《Structural Durability & Health Monitoring》 EI 2025年第1期167-191,共25页
When the upper chord beam of the beam-string structure(BSS)is made of concrete-filled steel tube(CFST),its overall stiffness will change greatly with the construction of concrete placement,which will have an impact on ... When the upper chord beam of the beam-string structure(BSS)is made of concrete-filled steel tube(CFST),its overall stiffness will change greatly with the construction of concrete placement,which will have an impact on the design of the tensioning plans and selection of control measures for the BSS.In order to accurately obtain the bending stiffness of CFST beam and clarify its impact on the mechanical properties of composite BSS during con-struction,the influence of some factors such as height-width ratio,wall thickness of steel tube,elasticity modulus of concrete,and friction coefficient on the bending stiffness are analyzed parametrically by the numerical simula-tion technology based on an actual project.The calculation formula of the equivalent bending stiffness of CFST is also established through mathematical statistical simulation.Then,the equivalent bending stiffness is introduced into the construction and use stages of the composite BSS,respectively,and the mechanical properties such as prestress-tensioning control value,structural deformation,and internal force of key members are comparatively analyzed when adopting two different construction plans.Moreover,the optimal construction plan of concrete placementfirst and then prestress-tensioning is proposed. 展开更多
关键词 Beam-string structure(BSS) concrete-filled steel tube(CFST) bending stiffness timing of concrete placement prestress-tensioning
下载PDF
Flexural Capacity Formula of Diaphragm-Through Joints of Concrete-Filled Square Steel Tubular Columns 被引量:1
6
作者 Bin Rong Rui Liu +3 位作者 Zhenyu Li Changxi Feng Guangchao You Fafitis Apostolos 《Transactions of Tianjin University》 EI CAS 2017年第3期258-266,共9页
Finite element analysis and parametric studies were performed to investigate the flexural capacity of the panel zone of diaphragm-through joints between concrete-filled square steel tubular columns and H-shaped steel ... Finite element analysis and parametric studies were performed to investigate the flexural capacity of the panel zone of diaphragm-through joints between concrete-filled square steel tubular columns and H-shaped steel beams. Through the comparisons of failure modes, load–displacement curves, and bearing capacity, it was found that the flexural capacity of the panel zone of diaphragm-through joints was determined by the tensile action and influence of the web of H-shaped steel beams, and the axial load should be taken into account. The steel tube and the diaphragm were the major parts of the joint that resisted the bending moment. The contribution of in-filled concrete had little influence on the flexural capacity of the panel zone of the joint and could be neglected. According to the results of these numerical studies, a formula that considered the influence of the web of H-shaped steel beams and the axial load was developed based on the yield lines in the diaphragm and the steel tube. The results of the proposed formula were in good agreement with the numerical data of this investigation. © 2017, Tianjin University and Springer-Verlag Berlin Heidelberg. 展开更多
关键词 Axial loads concreteS DIAPHRAGMS steel beams and girders Tubular steel structures Web crawler
下载PDF
Evaluation of Current Design Practices on Estimation of Axial Capacity of Concrete Encased Steel Composite Stub Columns: A Review
7
作者 Amiya Kumar Samanta Amit Paul 《Journal of Civil Engineering and Architecture》 2013年第9期1080-1091,共12页
This paper presents the design assessment of concrete encased I-sections composite column based approaches given in Eurocode, ACI Code, BS Code and AISC-LRFD. This study includes comparison of various design parameter... This paper presents the design assessment of concrete encased I-sections composite column based approaches given in Eurocode, ACI Code, BS Code and AISC-LRFD. This study includes comparison of various design parameters and evaluation of design strength based on the procedures predicted in the various codes of practices. A practical example has been assumed and calculation has been shown to evaluate their potentiality in understanding in predicting the potentiality of various procedures. The obtained results based on the methods varies widely, because of the different design considerations adopted by the different codes. As such, they have hardly considered the effect of confinement of the concrete due to the presence of longitudinal reinforcements as well as lateral ties. The study has attempted to throw light on critical review and their potentiality in assessing the strength of such concrete encased composite column under purely axial loads. 展开更多
关键词 concrete encased structural steel composite column design philosophy.
下载PDF
A Comparative Analysis for Land Utilization: Steel and R/C Interlaced Structures
8
作者 Kasim A.Korkmaz Saadet Toker Beeson Mohammed Elgafy 《Journal of Architectural Environment & Structural Engineering Research》 2020年第2期1-7,共7页
In architecture,interlace structural concept is considered as a new design approach for cosmopolitan cities with high density to minimize the land use and increase the interaction.With various architectural approach,l... In architecture,interlace structural concept is considered as a new design approach for cosmopolitan cities with high density to minimize the land use and increase the interaction.With various architectural approach,land resources can be minimized by this interlace concept for residential complexes.Such buildings will eliminate the reduction of land resource problem and on the other side safety measures in structural design is incorporated by interlace concept of buildings.This new concept can be constructed steel or reinforced concrete.In this paper,an analytical approach has been presented for these buildings in architecture and structural design.In the research,design considerations were taken for interlaced structures with reinforced concrete and steel.Components of steel structure,isolated footing,and columns.This paper is presenting a step wise process for interlaced structures.They are identification of project area,layout and model preparation,analysis and design of concrete interlaced structure,analysis and design of steel interlaced structure,drafting of the plans and costing and estimation of the structures.Comparison of both reinforced concrete and steel structures were carried out.The main aim of the paper is to provide a comparison between steel and concrete interlaced structure.A cost estimation was carried out to determine optimum design and construction for interlaced structures. 展开更多
关键词 Interlace Design project structural analysis Reinforced concrete steel
下载PDF
Identification of Connection Flexibility Effects Based on Load Testing of a Steel-Concrete Bridge
9
作者 Czeslaw Machelski Robert Toczkiewicz 《Journal of Civil Engineering and Architecture》 2012年第11期1504-1513,共10页
In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, doe... In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, does not provide full interaction of a steel beam and a concrete slab. This changes strain distribution in cross-sections of a composite girder and results in redistribution of internal forces in steel and concrete element. In the paper partial interaction index defined on the basis of a neutral axis position, which can be used for verification of steel-concrete interaction in real bridge structures rather than in specimens is proposed. The range of the index value changes, obtained during load testing of a typical steel-concrete composite beam bridge, is presented. The investigation was carried out on a motorway viaduct, consisting of two parallel structures. During the testing values of strains in girders under static and quasi-static loads were measured. The readings from the gauges were used to determine the index, characterizing composite action of the girders. Results of bridge testing under movable load, changing position along the bridge span is presented and obtained in-situ influence functions of strains and index values are commented in the paper. 展开更多
关键词 Abstract: In the case of composite girders an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs used commonly in bridge structures does not provide full interaction of a steel beam and a concrete slab. This changes strain distribution in cross-sections of a composite girder and results in redistribution of internal forces in steel and concrete element. In the paper partial interaction index defined on the basis of a neutral axis position which can be used for verification of steel-concrete interaction in real bridge structures rather Composite bridge partial interaction
下载PDF
Static behavior of semi-rigid thin-walled steel-concrete composite beam-to-column joints with bolted partial-depth flush end plate:experimental study
10
作者 郜京峰 张耀春 +2 位作者 王海明 姚淇誉 金路 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第5期91-102,共12页
A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic ... A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints. 展开更多
关键词 SEMI-RIGID thin-walled steel-concrete composite structures beam-to-column joints static behavior experimental study
下载PDF
Application of laminated vierendeel truss in high-position transfer story structure 被引量:8
11
作者 戴国亮 童小东 +1 位作者 黄祥海 梁书亭 《Journal of Southeast University(English Edition)》 EI CAS 2005年第2期184-190,共7页
To meet the demands for large space and flexible compartmentation ofbuildings, laminated vierendeel trasses are adopted in high-position transfer story structures.First the bearing characteristics are analyzed, in whi... To meet the demands for large space and flexible compartmentation ofbuildings, laminated vierendeel trasses are adopted in high-position transfer story structures.First the bearing characteristics are analyzed, in which reasonable stiffness ratio of the upperchord, middle chord, and lower chord is derived. Then combined with an actual engineering model (1:8similar ratio), the static loading and pseudo-dynamic tests of two models for laminated vierendeeltrass used in transfer story structures are conducted, in which one model adopts reinforcedconcrete, and the other adopts prestressed concrete and shape steel concrete. Seismic behaviors areanalyzed, including inter-story displacement, base shear-displacement skeleton curves, andequivalent viscosity-damping curves. A program is programmed to carry out the elasto-plastic dynamicanalysis, and displacement time-history curves of the two models are derived. The test and analysisresults show that the laminated vierendeel trass with prestressed concrete and shape steel concretehas excellent seismic behaviors. It can solve the disadvantages of laminated vierendeel trussesused in transfer story structures. Finally, some design suggestions are put forward, which can bereferenced by similar engineering. 展开更多
关键词 laminated vierendeel trass steel concrete transfer story structure prestressed concrete elastro-plasticity analysis
下载PDF
Shear Behavior of Novel Prestressed Concrete Beam Subjected to Monotonic and Cyclic Loading
12
作者 余芳 姚大立 +1 位作者 贾金青 吴锋 《Transactions of Tianjin University》 EI CAS 2014年第4期257-265,共9页
Prestressed steel ultrahigh-strength reinforced concrete(PSURC) beam is a new type of prestressed concrete beam, which not only has a considerable compressive strength attributed to the ultrahigh strength concrete, bu... Prestressed steel ultrahigh-strength reinforced concrete(PSURC) beam is a new type of prestressed concrete beam, which not only has a considerable compressive strength attributed to the ultrahigh strength concrete, but also ensures a certain degree of ductility at failure due to the existence of structural steel. Five of these beams were monotonically tested until shear failure to investigate the static shear performance including the failure pattern, loaddeflection behavior, shear capacity, shear crack width and shear ductility. The experimental results show that these beams have superior shear capacity, crack control ability and shear ductility. To study the shear performance under repeated overloading, seven PSURC beams were loaded in cyclic test simultaneously. The overall shear performance of cycled beams is similar to that of uncycled beams at low load level but different at high load level. The shear capacity and crack control ability of cycled beams at high load level are reduced, whereas the shear ductility is improved. In addition, the influences of variables including the degree of prestress, stirrup ratio and load level on the shear performance of both uncycled and cycled beams were also discussed and compared, respectively. 展开更多
关键词 prestressed concrete beam structural steel ultrahigh strength concrete shear behavior cyclic loading
下载PDF
Technological development and engineering applications of novel steel-concrete composite structures 被引量:13
13
作者 Jianguo NIE Jiaji WANG +2 位作者 Shuangke GOU Yaoyu ZHU Jiansheng FAN 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2019年第1期1-14,共14页
In view of China's development trend of green building and building industrialization,based on the emerging requirements of the structural engineering community,the development and proposition of novel resourcesav... In view of China's development trend of green building and building industrialization,based on the emerging requirements of the structural engineering community,the development and proposition of novel resourcesaving high-performance steel-concrete composite structural systems with adequate safety and durability has become a kernel development trend in structural engineering.This paper provides a state of the art review of China's cutting-edge research and technologies in steel-concrete composite structures in recent years,including the building engineering,the bridge engineering and the special engineering.This paper summarizes the technical principles and applications of the long-span bi-directional composite structures,the long-span composite transfer structures,the comprehensive crack control technique based on uplift-restricted and slip-permitted (URSP)connectors,the steel plate concrete composite (SPCC)strengthen technique,and the innovative composite joints.By improving and revising traditional structure types, the comprehensive superiority of steel-concrete composite structures is well elicited.The research results also indicate that the high-performance steel-concrete composite structures have a promising popularizing prospect in the future. 展开更多
关键词 HIGH-PERFORMANCE COMPOSITE structure bi-directional COMPOSITE COMPOSITE transfer uplift-restricted and slip- permitted connectors steel plate concrete COMPOSITE STRENGTHEN
原文传递
Performance of steel bridge deck pavement structure with ultra high performance concrete based on resin bonding 被引量:1
14
作者 Hui ZHANG Zhixiang ZHANG +3 位作者 Peiwei GAO Lei CUI Youqiang PAN Kuan LI 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2021年第4期895-904,共10页
This research investigated a pavement system on steel bridge decks that use epoxy resin(EP)bonded ultra-high performance concrete(UHPC).Through FEM analysis and static and dynamic bending fatigue tests of the composit... This research investigated a pavement system on steel bridge decks that use epoxy resin(EP)bonded ultra-high performance concrete(UHPC).Through FEM analysis and static and dynamic bending fatigue tests of the composite structure,the influences of the interface of the pavement layer,reinforcement,and different paving materials on the structural performance were compared and analyzed.The results show that the resin bonded UHPC pavement structure can reduce the weld strain in the steel plate by about 32%and the relative deflection between ribs by about 52%under standard axial load conditions compared to traditional pavements.The EP bonding layer can nearly double the drawing strength of the pavement interface from 1.3 MPa,and improve the bending resistance of the UHPC structure on steel bridge decks by about 50%;the bending resistance of reinforced UHPC structures is twice that of unreinforced UHPC structure,and the dynamic deflection of the UHPC pavement structure increases exponentially with increasing fatigue load.The fatigue life is about 1.2×10^(7) cycles under a fixed force of 9 kN and a dynamic deflection of 0.35 mm,which meets the requirements for fatigue performance of pavements on steel bridge decks under traffic conditions of large flow and heavy load. 展开更多
关键词 steel bridge deck pavement ultra-high-performance concrete epoxy resin composite structure bending fatigue performance
原文传递
Characterization of the Reinforcing Steel Corrosion by Potentialdynamic Scan Approach
15
作者 乔国富 刘铁军 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2012年第3期418-421,共4页
Reinforcement corrosion is the major cause of damage and early failure of reinforced concrete structures worldwide with subsequent enormous costs for maintenance, restoration and replacement. Many methods used today f... Reinforcement corrosion is the major cause of damage and early failure of reinforced concrete structures worldwide with subsequent enormous costs for maintenance, restoration and replacement. Many methods used today for assessment of reinforcement corrosion are based on electrochemical techniques that determine the free corrosion potential or polarization resistance. Most of these methods always consider the B value in Stern-Geary equation as constant. However, B changes with different condition. In this paper, potentialdynamic method is used to characterize the corrosion of reinforcing steel. The corrosion rate of Q235 carbon steel is measured with concrete environment. B is calculated real-time. By this way, the error of reinforcement corrosion rate is minimized. 展开更多
关键词 concrete structures reinforcing steel CORROSION potentialdynamic scan
下载PDF
Structural Analysis of a RC Shear Wall by Use of a Truss Model
16
作者 Panagis G. Papadopoulos Periklis E. Lamprou 《Open Journal of Civil Engineering》 CAS 2022年第3期320-352,共33页
Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An itera... Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An iterative method is used. Initially, there are only concrete bars. Repeated structural analyses are performed. After each structural analysis, every concrete bar exceeding tensile strength is replaced by a steel bar. For every concrete bar exceeding compressive strength, first its section area is increased. If this is not enough, a steel bar is placed at the side of it. For every steel bar exceeding tensile or compressive strength, its section area is increased. After the end of every structural analysis, if all concrete and steel bars fall within tensile and compressive strengths, the output data are written and the analysis is terminated. Otherwise, the structural analysis is repeated. As all the necessary conditions (static, elastic, linearized geometric) are satisfied and the stresses of ALL concrete and steel bars fall within the tensile and compressive strengths, the results are acceptable. Usually, the proposed method exhibits a fast convergence in 4 - 5 repeats of structural analysis of the RC Shear Wall. 展开更多
关键词 Reinforced concrete Shear Wall structural Analysis Truss Model Iterative Method Computer Program Boundary Columns and Beam Grid of Horizontal and Diagonal Reinforcing steel Bars
下载PDF
预应力在我国大跨度结构中的应用研究综述 被引量:1
17
作者 梁书亭 王文康 +3 位作者 朱筱俊 徐义威 韩天成 董俊 《东南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2024年第3期559-566,共8页
为了提高大跨度结构的正常使用性能,通常在混凝土结构中施加预应力.结果表明,预应力混凝土结构具有更好的使用性、耐久性和大跨度适用性,其中预应力混凝土空心板结构在不显著降低承载力和刚度的前提下明显减小结构自重,预应力型钢混凝土... 为了提高大跨度结构的正常使用性能,通常在混凝土结构中施加预应力.结果表明,预应力混凝土结构具有更好的使用性、耐久性和大跨度适用性,其中预应力混凝土空心板结构在不显著降低承载力和刚度的前提下明显减小结构自重,预应力型钢混凝土梁(板)结构采用较小的截面尺寸即可满足承载力和刚度的需求.开发城市地下空间是解决城市用地紧张的有效手段,我国地下大跨空间常用的结构形式主要包括密排框架(肋梁)结构、折板或拱形结构、变截面(加腋)板结构、预应力混凝土结构、型钢-混凝土组合结构和Y形柱结构6种形式,相比之下,跨度较大时宜采用预应力结构. 展开更多
关键词 大跨度结构 城市地下空间 预应力技术 预应力空心结构 预应力型钢混凝土结构 工程案例
下载PDF
装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能 被引量:5
18
作者 曹万林 杨兆源 《北京工业大学学报》 CAS CSCD 北大核心 2024年第2期165-179,共15页
为研究装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能,对1个足尺轻钢框架结构试件和3个足尺轻钢框架-轻钢骨架轻混凝土墙板结构试件进行了低周反复荷载下的抗震性能试验及理论分析,试件变量包括:2种装配构造,即内嵌式装配墙板、外... 为研究装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能,对1个足尺轻钢框架结构试件和3个足尺轻钢框架-轻钢骨架轻混凝土墙板结构试件进行了低周反复荷载下的抗震性能试验及理论分析,试件变量包括:2种装配构造,即内嵌式装配墙板、外贴式装配墙板;2种轻钢骨架轻混凝土墙板,即框架式轻钢骨架轻混凝土墙板、桁架式轻钢骨架轻混凝土墙板。研究了各试件的破坏特征和损伤演化过程,分析了结构滞回特性、承载力、变形能力、刚度退化、耗能性能和应变。结果表明:装配式轻钢框架-轻钢骨架轻混凝土墙板结构共同工作性能良好,其水平承载力相比轻钢框架提高了204.7%~210.4%,抗侧刚度提高了257.3%~512.5%,结构变形及耗能能力有显著提高;内嵌墙板的自攻钉连接构造以及外贴墙板的螺栓连接构造传力性能可靠,结构具备2道抗震防线的受力特征;基于简化塑性分析模型以及拉压杆软化桁架模型,对试件承载力进行了计算,计算结果与试验符合较好。 展开更多
关键词 装配式组合结构 轻钢框架 轻钢骨架轻混凝土墙板 抗震性能 低周反复荷载试验 承载力计算
下载PDF
钢管混凝土键连接框架梁和剪力墙的受剪性能 被引量:1
19
作者 李明 刘栩邑 +2 位作者 吴潜 吴欣禹 吴永新 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2024年第1期38-46,共9页
目的 研究钢管混凝土键连接框架梁和剪力墙的受剪性能,为工程应用提供设计依据。方法 应用有限元分析软件ABAQUS对比钢管混凝土键连接与现浇连接梁墙的结构受剪性能,分析前者受剪机理及不同因素对受剪性能的影响。结果 钢管混凝土键连... 目的 研究钢管混凝土键连接框架梁和剪力墙的受剪性能,为工程应用提供设计依据。方法 应用有限元分析软件ABAQUS对比钢管混凝土键连接与现浇连接梁墙的结构受剪性能,分析前者受剪机理及不同因素对受剪性能的影响。结果 钢管混凝土键连接梁墙的结构承载力和延性系数较现浇结构分别提高约10%和34%;钢材强度从Q235到Q390,初始刚度增加8.44%;截面高度从100 mm到120 mm,延性系数提高17.73%;截面厚度每增加2 mm,承载力提高约15%;截面长度和混凝土强度等级对承载力、初始刚度和延性系数的影响均小于15%,纵向距离对其受剪性能几乎无影响。结论 采用钢管混凝土键连接梁墙的结构总体受剪性能优于现浇结构;钢材强度和截面厚度分别是影响初始刚度和承载力的主要因素。 展开更多
关键词 钢管混凝土键 框架-剪力墙结构 梁墙试件 抗剪性能 有限元分析
下载PDF
乌兹别克斯坦9度区某超高层建筑结构设计与优化 被引量:1
20
作者 闫锋 花炳灿 安东亚 《建筑结构》 北大核心 2024年第13期51-56,共6页
对于9度设防地区的超高层建筑,其结构设计基本由地震作用控制,因此抗震设计尤为重要。建筑消能减震技术可在提高结构地震安全储备的同时,降低整体工程造价,是结构优化设计的有效措施。对位于9度区的超高层建筑进行了结构方案选型对比、... 对于9度设防地区的超高层建筑,其结构设计基本由地震作用控制,因此抗震设计尤为重要。建筑消能减震技术可在提高结构地震安全储备的同时,降低整体工程造价,是结构优化设计的有效措施。对位于9度区的超高层建筑进行了结构方案选型对比、结构方案优化、减震设计方案比选、剪力墙内嵌钢板优化。结果显示,钢骨混凝土框架⁃核心筒方案相对于钢框架⁃支撑方案具备更高的成本优势;框架⁃核心筒方案可通过精细化设计作进一步优化;在此基础上,对钢骨混凝土框架⁃核心筒方案采用两种消能减震方案进行比选,结果表明,采用黏滞阻尼器方案的结构抗震性能明显优于采用黏滞阻尼墙方案;最后通过增大剪力墙竖向分布钢筋配筋率,对低区核心筒墙肢中的内嵌钢板进行了优化。 展开更多
关键词 9度抗震设防 超高层建筑 钢骨混凝土结构 框架⁃核心筒 消能减震
下载PDF
上一页 1 2 175 下一页 到第
使用帮助 返回顶部