A new kind of mortar made of ground granulated blast-furnace slag (GGBFS), gypsum, clinker and steel slag sand (〈4.75 mm) was developed. The ratio of steel slag sand to GGBFS was 1 : 1 and the amount of gypsum w...A new kind of mortar made of ground granulated blast-furnace slag (GGBFS), gypsum, clinker and steel slag sand (〈4.75 mm) was developed. The ratio of steel slag sand to GGBFS was 1 : 1 and the amount of gypsum was 4% by weight while the dosage of clinker ranged from 0% to 24%. The optimization formulation of such mortar was studied. The content of steel slag sand should be less than 50% according to the volume stability of blended mortar, and the dosage of clinker is about 10% based on the strength development. Besides strength, the hydration heat, pore structure and micro pattern of blended mortar were also determined. The experimental results show the application of steel slag sand may reduce the dosage of cement clinker and increase the content of industrial waste product such as GGBFS, and the clinker is also a better admixture for blended mortar using steel slag sand.展开更多
Background: A high ability to visualize the needle on the ultrasonic images is necessary to perform the ultrasound-guided nerve block safely. The Rafa Tuohy needle<sup>R</sup> (Vygon, Paris, France, Rafa) ...Background: A high ability to visualize the needle on the ultrasonic images is necessary to perform the ultrasound-guided nerve block safely. The Rafa Tuohy needle<sup>R</sup> (Vygon, Paris, France, Rafa) is a non-stimulating Tuohy needle with sand-blasted steel at the tip of the bevel. We examined the degree to which the Rafa enhanced the visibility of ultrasonic images compared with the non-coated Tuohy needle. Methods: We punctured the Blue Phantom. The dimensions of both the Rafa and the non-coated Tuohy needles were 18 G × 80 mm. The puncture angle is 30 degrees and 45 degrees from the Blue Phantom. We measured the intensity of the tip of the bevel at a depth of 0.5, 1.0, 1.5 and 2.0 cm for the puncture angle of 30 degrees, and 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 cm for the puncture angle of 45 degrees. Six anesthesiologists with more than seven years of experience performed three punctures using each needle. Results: As an outcome, we concluded that at a puncture angle of both 30 degrees and 45 degrees, the intensity of the non-coated Tuohy needle decreased with the depth. On the other hand, at an angle of 30 degrees, the intensity of the Rafa needle did not decrease, and at an angle of 45 degrees the intensity only decreased very slightly as the depth increased. Conclusions: The Tuohy needle with sand-blasted steel at the tip of the bevel provided greater visualization than the non-coated Tuohy needle on the ultrasound images.展开更多
基金the National Natural Science Foundation of China(50678139)the Open Foundation Program of Key Laboratory of Silicate Materials Science and Engineering of Ministry of Education(Wuhan University of Technology) China(No.SYSJJ2005-08)
文摘A new kind of mortar made of ground granulated blast-furnace slag (GGBFS), gypsum, clinker and steel slag sand (〈4.75 mm) was developed. The ratio of steel slag sand to GGBFS was 1 : 1 and the amount of gypsum was 4% by weight while the dosage of clinker ranged from 0% to 24%. The optimization formulation of such mortar was studied. The content of steel slag sand should be less than 50% according to the volume stability of blended mortar, and the dosage of clinker is about 10% based on the strength development. Besides strength, the hydration heat, pore structure and micro pattern of blended mortar were also determined. The experimental results show the application of steel slag sand may reduce the dosage of cement clinker and increase the content of industrial waste product such as GGBFS, and the clinker is also a better admixture for blended mortar using steel slag sand.
文摘Background: A high ability to visualize the needle on the ultrasonic images is necessary to perform the ultrasound-guided nerve block safely. The Rafa Tuohy needle<sup>R</sup> (Vygon, Paris, France, Rafa) is a non-stimulating Tuohy needle with sand-blasted steel at the tip of the bevel. We examined the degree to which the Rafa enhanced the visibility of ultrasonic images compared with the non-coated Tuohy needle. Methods: We punctured the Blue Phantom. The dimensions of both the Rafa and the non-coated Tuohy needles were 18 G × 80 mm. The puncture angle is 30 degrees and 45 degrees from the Blue Phantom. We measured the intensity of the tip of the bevel at a depth of 0.5, 1.0, 1.5 and 2.0 cm for the puncture angle of 30 degrees, and 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 cm for the puncture angle of 45 degrees. Six anesthesiologists with more than seven years of experience performed three punctures using each needle. Results: As an outcome, we concluded that at a puncture angle of both 30 degrees and 45 degrees, the intensity of the non-coated Tuohy needle decreased with the depth. On the other hand, at an angle of 30 degrees, the intensity of the Rafa needle did not decrease, and at an angle of 45 degrees the intensity only decreased very slightly as the depth increased. Conclusions: The Tuohy needle with sand-blasted steel at the tip of the bevel provided greater visualization than the non-coated Tuohy needle on the ultrasound images.