The seismic performance of a fully fabricated bridge is a key factor limiting its application.In this study,a fiber element model of a fabricated concrete pier with grouting sleeve-prestressed tendon composite connect...The seismic performance of a fully fabricated bridge is a key factor limiting its application.In this study,a fiber element model of a fabricated concrete pier with grouting sleeve-prestressed tendon composite connections was built and verified.A numerical analysis of three types of continuous girder bridges was conducted with different piers:a cast-in-place reinforced concrete pier,a grouting sleeve-fabricated pier,and a grouting sleeve-prestressed tendon composite fabricated pier.Furthermore,the seismic performance of the composite fabricated pier was investigated.The results show that the OpenSees fiber element model can successfully simulate the hysteresis behavior and failure mode of the grouted sleeve-fabricated pier.Under traditional non-near-fault ground motions,the pier top displacements of the grouting sleeve-fabricated pier and the composite fabricated pier were less than those of the cast-in-place reinforced concrete pier.The composite fabricated pier had a good self-centering capability.In addition,the plastic hinge zones of the grouting sleeve-fabricated pier and the composite fabricated pier shifted to the joint seam and upper edge of the grouting sleeve,respectively.The composite fabricated pier with optimal design parameters has good seismic performance and can be applied in high-intensity seismic areas;however,the influence of pile-soil interaction on its seismic performance should not be ignored.展开更多
The static test of two single light wood trusses and two girder trusses were carried out to explore theperformance enhancement effect of girder trusses and the influence of different connection types on the mechanical...The static test of two single light wood trusses and two girder trusses were carried out to explore theperformance enhancement effect of girder trusses and the influence of different connection types on the mechanicalbehavior, which was studied through the comparison of the test results of four trusses. It is found that the girder trussescan show better load-carrying capacity and anti-deforming ability compared with which simply increases the cross-sectionsize of the members. Because of the advantage of the connection materials and the non-fastening connection mechanism,the wood pin-connected truss has more ultimate bearing capacity which is 2.6 times of single truss, and better deformationresistance which is only 66.2% of the nailed one’s creep value.展开更多
基金This study was supported by the National Natural Science Foundation of China(Grant Nos.52108428,52178446,51978021,and 51908015)the Fundamental Research Funds for the Central Universities(No.2023MS067).We gratefully acknowledge their support.
文摘The seismic performance of a fully fabricated bridge is a key factor limiting its application.In this study,a fiber element model of a fabricated concrete pier with grouting sleeve-prestressed tendon composite connections was built and verified.A numerical analysis of three types of continuous girder bridges was conducted with different piers:a cast-in-place reinforced concrete pier,a grouting sleeve-fabricated pier,and a grouting sleeve-prestressed tendon composite fabricated pier.Furthermore,the seismic performance of the composite fabricated pier was investigated.The results show that the OpenSees fiber element model can successfully simulate the hysteresis behavior and failure mode of the grouted sleeve-fabricated pier.Under traditional non-near-fault ground motions,the pier top displacements of the grouting sleeve-fabricated pier and the composite fabricated pier were less than those of the cast-in-place reinforced concrete pier.The composite fabricated pier had a good self-centering capability.In addition,the plastic hinge zones of the grouting sleeve-fabricated pier and the composite fabricated pier shifted to the joint seam and upper edge of the grouting sleeve,respectively.The composite fabricated pier with optimal design parameters has good seismic performance and can be applied in high-intensity seismic areas;however,the influence of pile-soil interaction on its seismic performance should not be ignored.
基金National Key Technology Research and Development Program for the 12th Fiveyear Plan of China(No.2015BAD14B05).
文摘The static test of two single light wood trusses and two girder trusses were carried out to explore theperformance enhancement effect of girder trusses and the influence of different connection types on the mechanicalbehavior, which was studied through the comparison of the test results of four trusses. It is found that the girder trussescan show better load-carrying capacity and anti-deforming ability compared with which simply increases the cross-sectionsize of the members. Because of the advantage of the connection materials and the non-fastening connection mechanism,the wood pin-connected truss has more ultimate bearing capacity which is 2.6 times of single truss, and better deformationresistance which is only 66.2% of the nailed one’s creep value.