Wall cracking and mold expanding due to concrete vibrations can be effectively solved through the application of precast normal-concrete composite shear walls infilled with self-compacting concrete(SCC). However, the ...Wall cracking and mold expanding due to concrete vibrations can be effectively solved through the application of precast normal-concrete composite shear walls infilled with self-compacting concrete(SCC). However, the high liquidity of SCC will induce a higher lateral pressure. Therefore, it is important to obtain a better understanding of the template lateral pressure. In this work, nine composite shear walls were experimentally investigated, focusing on the effects of two parameters, i.e., the casting rate and the section width of the formwork. The time-varying pressure was monitored during the SCC pouring. It is found that the increase of casting rate from 3.2 m/h to 10.3 m/h resulted in a higher maximum lateral pressure. The higher casting rate led to a longer time required for the lateral pressure to drop to a steady value. There was no correlation between the section width and the rate of decrease in the initial formwork pressure and stable value. Based on the test results, a formula considering the effect of casting speed for the calculation of SCC formwork pressure was established to fill the gap in the current standards and for engineering applications.展开更多
Utilizing pre-cast ECC panels as participating permanent formwork of concrete members, and the validity of using ECC to disperse the single crack in concrete into multiple ones in ECC were studied. In the process, tot...Utilizing pre-cast ECC panels as participating permanent formwork of concrete members, and the validity of using ECC to disperse the single crack in concrete into multiple ones in ECC were studied. In the process, totally two kinds of ECC with different tensile properties, 7 series of flat panels with different top surface figures and 3 U-shape panels with different inner surface forms were investigated. To evaluate the performance of the permanent formworks, small ECC-concrete composite beams were cast and tested mechanically. The 4-point bending test results show that the use of pre-cast ECC panels as permanent formwork can significantly improve the load capacity and toughness of a concrete member, effectively dispersing single widely opened crack in concrete into multiple ones in ECC. Most permanent formworks show perfect bond with the concrete cast on them, while the ones with partially debonded zone achieve the best mechanical performance. The U-shape permanent formworks show better performances than the flat ones, achieving much betler improvements in both the load capacity and toughness, together with better crack width control.展开更多
基金Funded by the National Natural Science Foundation of China(No.51178218)the Cooperation Project of Yangzhou Science and Technology Bureau(YZ2016267)
文摘Wall cracking and mold expanding due to concrete vibrations can be effectively solved through the application of precast normal-concrete composite shear walls infilled with self-compacting concrete(SCC). However, the high liquidity of SCC will induce a higher lateral pressure. Therefore, it is important to obtain a better understanding of the template lateral pressure. In this work, nine composite shear walls were experimentally investigated, focusing on the effects of two parameters, i.e., the casting rate and the section width of the formwork. The time-varying pressure was monitored during the SCC pouring. It is found that the increase of casting rate from 3.2 m/h to 10.3 m/h resulted in a higher maximum lateral pressure. The higher casting rate led to a longer time required for the lateral pressure to drop to a steady value. There was no correlation between the section width and the rate of decrease in the initial formwork pressure and stable value. Based on the test results, a formula considering the effect of casting speed for the calculation of SCC formwork pressure was established to fill the gap in the current standards and for engineering applications.
基金Funded by the Hong Kong Research Grant Council(No. CERGUST6138/04E)the Key Program of National Natural Science Foundation of China(No. 50438010)the Research & Application of Key Technology for the South-North Water Transfer Project Construction in China(No.JGZXJJ2006-13)
文摘Utilizing pre-cast ECC panels as participating permanent formwork of concrete members, and the validity of using ECC to disperse the single crack in concrete into multiple ones in ECC were studied. In the process, totally two kinds of ECC with different tensile properties, 7 series of flat panels with different top surface figures and 3 U-shape panels with different inner surface forms were investigated. To evaluate the performance of the permanent formworks, small ECC-concrete composite beams were cast and tested mechanically. The 4-point bending test results show that the use of pre-cast ECC panels as permanent formwork can significantly improve the load capacity and toughness of a concrete member, effectively dispersing single widely opened crack in concrete into multiple ones in ECC. Most permanent formworks show perfect bond with the concrete cast on them, while the ones with partially debonded zone achieve the best mechanical performance. The U-shape permanent formworks show better performances than the flat ones, achieving much betler improvements in both the load capacity and toughness, together with better crack width control.