期刊文献+
共找到750篇文章
< 1 2 38 >
每页显示 20 50 100
Novel approach of ultrasound-guided lateral recess block for a patient with lateral recess stenosis: A case report 被引量:1
1
作者 Jiao Yang Xin-Ling Li Qing-Bing Li 《World Journal of Clinical Cases》 SCIE 2024年第5期1010-1017,共8页
BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultraso... BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultrasound-guided Lateral recess block(LRB)are limited,this is probably because there is no recognized standard method for ultrasound scanning.This study aimed to evaluate the effect of ultrasound-guided LRB in patients with lateral recess stenosis(LRS).CASE SUMMARY A 65-year-old patient complained of low back pain accompanied occasionally by pain and numbness in the left lower limb.Physical examination showed ten-derness on the spinous process and paraspinal muscles from L1 to S1,extensor hallucis longus and tibialis anterior weakness(muscle strength:4-),and a positive straight leg raising test in the left lower limb(60°).Magnetic resonance imaging showed L4–L5 disc degeneration with left LRS and nerve root entrapment.Subsequently,the patient was diagnosed with LRS.This patient was treated with a novel ultrasound-guided LRB approach.The patient’s symptoms significantly improved without any complications at 1 wk postoperatively and at the 3-month follow-up.CONCLUSION This is the first report on the LRS treatment with ultrasound-guided LRB from the contralateral spinous process along the inner side of the articular process by out-plane technique.Further studies are expected to investigate the efficacy and safety of ultrasound-guided LRB for patients with LRS. 展开更多
关键词 Lateral recess stenosis ULTRASOUND Lateral recess block Real-time visualization Low back pain Case report
下载PDF
Accurate diagnosis of severe coronary stenosis based on resting magnetocardiography: a prospective, single-center, cross-sectional analysis
2
作者 Jian-Guo CUI Feng TIAN +7 位作者 Yu-Hao MIAO Qin-Hua JIN Ya-Jun SHI Li LI Meng-Jun SHEN Xiao-Ming XIE Shu-Lin ZHANG Yun-Dai CHEN 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第4期407-420,共14页
OBJECTIVE To evalu ate the role of resting magnetocardiography in identifying seve re coronary artery stenosis in patients with suspected coronary artery disease.METHODS A total of 513 patients with angina symptoms we... OBJECTIVE To evalu ate the role of resting magnetocardiography in identifying seve re coronary artery stenosis in patients with suspected coronary artery disease.METHODS A total of 513 patients with angina symptoms were included and divided into two groups based on the extent of coronary artery disease determined by angiography:the non-severe coronary stenusis group(<70% stenosis) and the severe coronary stenosis group(≥70% stenosis).The diagnostic model was constructed using magnetic field map(MFM) parameters,either individually or in combination with clinical indicators.The performance of the models was evaluated using receiver operating characteristic curves,accuracy,sensitivity,specificity,positive predictive value(PPV) and ne gative predictive value(NPV).Calibration plots and decision curve analysis were performed to investigate the clinical utility and performance of the models,respectively.RESULTS In the severe coronary stenosis group,QR_MCTDd,S_MDp,and TT_(MA)C_(50) were significantly higher than those in the non-severe coronary stenosis group(10,46±10.66 vs,5.11±6.07,P <0.001;7.2±8.64 vs.4.68±6.95,P=0.003;0.32±57.29 vs.0.26±57.29,P <0.001).While,QR_MV_(amp),R_(MA),and T_(MA) in the severe coronary stenosis group were lower(0.23±0.16 vs.0.28±0.16,P<0.001;55.06±48.68 vs.59.24±53.01,P<0.001;51.67±39.32 vs. 60.45±51.33,P <0.001).Seven MFM parameters were integrated into the model,resulting in an area under the curve of 0.810(95% CI:0.765-0.855).The sensitivity,specificity,PPV,NPV,and accurecy were 71.7%,80.4%,93.3%,42.8 %,and 73.5%;respectevely.The combined model exhibited an area under the curve of 0.845(95% CI:0.798-0.892).The sensitivity,specificity,PPV,NPV,and accuracy were 84.3%,73.8%,92.6%,54.6%,and 82.1%;respectively.Calibration curves demonstrate d excellent agreement between the nomogram prediction and actual observation.The decision curve analysis showed that the c ombine d model provided greater net benefit compared to the magnetocardingraphy model.CONCLUSIONS The novel quantitative MFM parameters,whether used individually or in combination with clinical indicators,have been shown to effectively pre dict the risk of severe coronary stenosis in patients presenting with angina-like symptoms.Magnetocardiography,an emerging non-invasive diagnostic tool,warrants further exploration for its potential in diagnosing coronary heart disease. 展开更多
关键词 CORONARY stenosis SPECIFICITY
下载PDF
Diagnostic performance of intravascular ultrasound-based fractional flow reserve in evaluating of intermediate left main stenosis
3
作者 Yong-Gang SUI Cheng YANG +11 位作者 Chang-Dong GUAN Yan-Lu XU Na-Qiong WU Wei-Xian YANG Yong-Jian WU Ke-Fei DOU Yue-Jin YANG Shu-Bin QIAO Wei YU Bo XU Sheng-Xian TU Jie QIAN 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第1期34-43,共10页
BACKGROUND The recently introduced ultrasonic flow ratio(UFR),is a novel fast computational method to derive fractional flow reserve(FFR)from intravascular ultrasound(IVUS)images.In the present study,we evaluate the d... BACKGROUND The recently introduced ultrasonic flow ratio(UFR),is a novel fast computational method to derive fractional flow reserve(FFR)from intravascular ultrasound(IVUS)images.In the present study,we evaluate the diagnostic performance of UFR in patients with intermediate left main(LM)stenosis.METHODS This is a prospective,single center study enrolling consecutive patients with presence of intermediated LM lesions(diameter stenosis of 30%-80%by visual estimation)underwent IVUS and FFR measurement.An independent core laboratory assessed offline UFR and IVUS-derived minimal lumen area(MLA)in a blinded fashion.RESULTS Both UFR and FFR were successfully achieved in 41 LM patients(mean age,62.0±9.9 years,46.3%diabetes).An acceptable correlation between UFR and FFR was identified(r=0.688,P<0.0001),with an absolute numerical difference of 0.03(standard difference:0.01).The area under the curve(AUC)in diagnosis of physiologically significant coronary stenosis for UFR was 0.94(95%CI:0.87-1.01),which was significantly higher than angiographic identified stenosis>50%(AUC=0.66,P<0.001)and numerically higher than IVUS-derived MLA(AUC=0.82;P=0.09).Patient level diagnostic accuracy,sensitivity and specificity for UFR to identify FFR≤0.80 was 82.9%(95%CI:70.2-95.7),93.1%(95%CI:82.2-100.0),58.3%(95%CI:26.3-90.4),respectively.CONCLUSION In patients with intermediate LM diseases,UFR was proved to be associated with acceptable correlation and high accuracy with pressure wire-based FFR as standard reference.The present study supports the use of UFR for functional evaluation of intermediate LM stenosis. 展开更多
关键词 stenosis FLOW FRACTIONAL
下载PDF
Significance of balloon aortic valvuloplasty as palliative procedure for symptom benefit in patients with severe aortic stenosis
4
作者 Jovica Banovic Vladimir Djuric +1 位作者 Vojislav Vuksinovic Sasa Loncar 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第3期374-378,共5页
Aortic stenosis(AS)stands out as the most prevalent individual valvular defect globally.The onset and progression of AS mirror an active process akin to atherosclerosis,and the traditional triad of symptoms includes c... Aortic stenosis(AS)stands out as the most prevalent individual valvular defect globally.The onset and progression of AS mirror an active process akin to atherosclerosis,and the traditional triad of symptoms includes chest pain,breathlessness,and loss of consciousness.Prognosis takes a significant downturn when symptoms manifest,with mortality reaching approximately 50%-85% within the subsequent 5 years after symptom onset. 展开更多
关键词 BALLOON stenosis MORTALITY
下载PDF
0D-1D coupling model and 3D fluid-structure interaction model based on coronary CT angiography for displaying hemodynamic characteristics of coronary artery stenosis
5
作者 LIU Shanfeng LU Xiaochen +1 位作者 TIAN Hao WU Huiqun 《中国医学影像技术》 CSCD 北大核心 2024年第8期1236-1241,共6页
Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Base... Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis. 展开更多
关键词 coronary stenosis HEMODYNAMICS coronary angiography tomography X-ray computed
下载PDF
Transparent cap adjusted the stent placed for stenosis after endoscopic injection of esophageal varices:A case report
6
作者 Fu-Long Zhang Jing Xu +8 位作者 Yuan-Dong Zhu Qian-Neng Wu Yan Shi Lei Fang Dan Zhou Hai Wang Chao-JunHuang Chun-Hua Zhou Qun Zhu 《World Journal of Clinical Cases》 SCIE 2024年第15期2614-2620,共7页
BACKGROUND The stent embedded in the esophageal mucosa is one of the complications after stenting for esophageal stricture.We present a case of stent adjustment with the aid of a transparent cap after endoscopic injec... BACKGROUND The stent embedded in the esophageal mucosa is one of the complications after stenting for esophageal stricture.We present a case of stent adjustment with the aid of a transparent cap after endoscopic injection of an esophageal varices stent.CASE SUMMARY A 61-year-old male patient came to the hospital with discomfort of the chest after the stent implanted for the stenosis because of endoscopic injection of esophageal varices.The gastroscopy was performed,and the stent embedded into the esophageal mucosa.At first,we pulled the recycling line for shrinking the stent,however,the mucosa could not be removed from the stent.Then a forceps was performed to remove the mucosa in the stent,nevertheless,the bleeding form the mucosa was obvious.And then,we used a transparent cap to scrape the mucosa along the stent,and the mucosa were removed successfully without bleeding.CONCLUSION A transparent cap helps gastroscopy to remove the mucosa embedded in the stent after endoscopic injection of the esophageal varices stent. 展开更多
关键词 STENT Transparent cap stenosis Endoscopic injection Esophageal varices Case report
下载PDF
Endoscopic treatment of extreme esophageal stenosis complicated with esophagotracheal fistula: A case report
7
作者 Jia-Heng Fang Wei-Min Li +4 位作者 Cheng-Hai He Jian-Liang Wu Yun Guo Zhi-Chao Lai Guo-Dong Li 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期239-247,共9页
BACKGROUND At present,there is no unified and effective treatment for extreme corrosive esophageal stenosis(CES)with esophagotracheal fistula(ETF).This case had extreme and severe esophageal stenosis(ES)and ETF after ... BACKGROUND At present,there is no unified and effective treatment for extreme corrosive esophageal stenosis(CES)with esophagotracheal fistula(ETF).This case had extreme and severe esophageal stenosis(ES)and ETF after ingesting an enzyme-based chemical detergent,resulting in a serious pulmonary infection and severe malnutrition.Upper gastrointestinal imaging showed that he had an ETF,and endoscopy showed that he had extreme and severe esophageal stricture.This case was complex and difficult to treat.According to the domestic and foreign lite-rature,there is no universal treatment that is low-risk.CASE SUMMARY A patient came to our hospital with extreme ES,an ETF,and severe malnutrition complicated with pulmonary tuberculosis 1 mo after the consumption of an enzy-me-based detergent.The ES was serious,and the endoscope was unable to pass through the esophagus.We treated him by endoscopic incision method(EIM),esophageal stent placement(ESP),and endoscopic balloon dilation(EBD)by using the bronchoscope and gastroscope.This treatment not only closed the ETF,but also expanded the esophagus,with minimal trauma,greatly reducing the pain of the patient.According to the literature,there are no similar reported cases.CONCLUSION We report,for the first time,a patient with extreme CES complicated with ETF,where the endoscope could not be passed through his esophagus but he could be examined by bronchoscopy and treated by EIM,ESP,and EBD. 展开更多
关键词 Extreme corrosive esophageal stenosis Esophagotracheal fistula Endoscopic incision method Esophageal stent placement Endoscopic balloon dilation Case report
下载PDF
Percutaneous transhepatic stenting for acute superior mesenteric vein stenosis after pancreaticoduodenectomy with portal vein reconstruction:A case report
8
作者 Chen Lin Zi-Yan Wang +3 位作者 Liang-Bo Dong Zhi-Wei Wang Ze-Hui Li Wei-Bin Wang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第4期1195-1202,共8页
BACKGROUND Percutaneous transhepatic stent placement has become a common strategy for the postoperative treatment of portal vein(PV)/superior mesenteric veins(SMV)stenosis/occlusion.It has been widely used after liver... BACKGROUND Percutaneous transhepatic stent placement has become a common strategy for the postoperative treatment of portal vein(PV)/superior mesenteric veins(SMV)stenosis/occlusion.It has been widely used after liver transplantation surgery;however,reports on stent placement for acute PV/SMV stenosis after pancreatic surgery within postoperative 3 d are rare.CASE SUMMARY Herein,we reported a case of intestinal edema and SMV stenosis 2 d after pancreatic surgery.The patient was successfully treated using stent grafts.Although the stenosis resolved after stent placement,complications,including bleeding,pancreatic fistula,bile leakage,and infection,made the treatment highly challenging.The use of anticoagulants was adjusted multiple times to prevent venous thromboembolism and the risk of bleeding.After careful treatment,the patient stabilized,and stent placement effectively managed postoperative PV/SMV stenosis.CONCLUSION Stent placement is effective and feasible for treating acute PV/SMV stenosis after pancreatic surgery even within postoperative 3 d. 展开更多
关键词 PANCREATICODUODENECTOMY Portal vein reconstruction Portal vein stenosis Portal vein stent Case report
下载PDF
Surgical Management of Lumbar Spinal Canal Stenosis with Instrumentation at the Yaounde Central Hospital: Comparison of Unilateral versus Bilateral Pedicle Screw Fixation Combined with Transforaminal Lumbar Interbody Fusion
9
作者 Orlane Toto Ndome Nassourou Oumarou Haman +4 位作者 Dimitri Fogue Jean Bruno Ndoumou Ronaldo Fonju Anu Indira Baboke Vincent De Paul Djientcheu 《Open Journal of Modern Neurosurgery》 2024年第3期179-189,共11页
Introduction: The choice of adopting unilateral pedicle screw fixation or using bilateral pedicle screw fixation in lumbar spinal stenosis remains controversial. In our context, very few studies have been performed co... Introduction: The choice of adopting unilateral pedicle screw fixation or using bilateral pedicle screw fixation in lumbar spinal stenosis remains controversial. In our context, very few studies have been performed comparing the clinical effectiveness of unilateral versus bilateral fixation in the surgical management of lumbar spinal canal stenosis. Objective: Evaluate the impact on quality of life and clinical efficacy of unilateral spondylodesis compared to bilateral spondylodesis in the surgical management of lumbar spinal canal stenosis at the Yaounde Central Hospital. Methods: This was a retrospective descriptive cross-sectional study for a period of 4 years, from June 2015 to June 2019. It involved all patients operated for lumbar canal stenosis and who underwent spondylodesis or spinal fusion at the neurosurgery department of the Yaounde Central Hospital. Results: A total of 68 participants were recruited during our study period. 32 (47%) of the study population were in the 50 - 60 age group, with a mean age of 56.98 years ranging from 41 to 75 years. Females, housewives and farmers were the most affected. In our study, 72% of patients had unilateral spondylodesis and 28% had bilateral fusion. Preoperatively, 71% of patients had insurmountable pain, refractory to medical treatment. At 3 months postoperatively, 73.7% of patients with bilateral setup had moderate pain compared to 69% of those with unilateral setup. At 6 months postoperatively, 79% of patients with bilateral fusion had mild pain compared to 82% of patients with unilateral setup. At 1 year postoperatively, all patients had mild pain. Preoperatively, 66.2% of patients were unable to walk and 19.1% of patients were bedridden according to the Oswestry score. At 3 months postoperatively, 10.2% of patients with unilateral setup were unable to walk compared to 10.5% of patients with bilateral fixation, while 67.3% of patients with unilateral fixation had moderate disability compared to 52.6% of patients with bilateral fixation. At 6 months postoperatively, 51% of patients with unilateral setup had moderate disability compared to 47.4% of patients with bilateral fixation, while 42.9% of patients with unilateral fixation had mild disability compared to 42.1% of patients with bilateral fixation. At 1 year postoperatively, 81.6% of patients who underwent unilateral fixation had only mild disability compared to 73.7% of patients with bilateral fixation. Conclusion: The assessment of quality of life according to the set-up used shows similar results at 3 months, 6 months and 1 year, with no statistically significant differences. Single-sided pedicle screw fixation combined with transforaminal lumbar interbody fusion or mounting has the advantage of being faster, with less bleeding and is less expensive compared to bilateral fixation. 展开更多
关键词 Lumbar Spinal Canal stenosis INSTRUMENTATION Surgery Quality of Life
下载PDF
Endoscopic Internal Urethrotomy in the Treatment of Male Urethral Stenosis in the Urology-Andrology Department of KARA Teaching Hospital (Togo)
10
作者 Musapudi Éric Mbuya Komi Hola Sikpa +4 位作者 Edoe Viyome Sewa Messan Semefa Agbedey Gnimdou Botcho Kodjo Tengue Tchilabalo Matchonna Kpatcha 《Open Journal of Urology》 2024年第1期20-26,共7页
Introduction: Endoscopic internal urethrotomy (EIU) is a method for stricture opening using transurethral incision by direct visualisation of the urethral channel, resulting in a widening of the urinary canal with the... Introduction: Endoscopic internal urethrotomy (EIU) is a method for stricture opening using transurethral incision by direct visualisation of the urethral channel, resulting in a widening of the urinary canal with the aim of improving the quality of bladder emptying. The aim of the study was to evaluate the indication and results of EIU in the treatment of stenosis of the male urethra in the Urology-Andrology Department of Kara Teaching Hospital. Methodology: This was a cross-sectional descriptive study with retrospective data collection in the Urology-Andrology department of Kara Teaching Hospital. It involved 21 records of patients with urethral stenosis treated by endoscopic internal urethrotomy (EIU) in the said department during the period from January 2021 to September 2023. The following variables were evaluated: age, circumstance of discovery, site, length, number, etiology of the urethral stenosis and evolution of the patients. Results: The mean age of the patients was 59.2 ± 11.7 years. Infectious etiology of stenosis was predominant with 10 patients (47.6%) followed by trauma with 5 cases (23.8%). The bulbar urethra was the most frequently observed site, with 11 cases (52.4%). The length was mostly less than 2 cm in 12 patients (57.1%). Stenosis was unique in 14 patients (66.7%). The mean postoperative follow-up time was 3.2 months. The result was immediately better in 11 patients (52.4%) and it was poor in 8 patients (38.1%) who required maintenance dilation sessions. 展开更多
关键词 Internal Urethrotomy Urethral stenosis Kara TOGO
下载PDF
Effectiveness of Combined Dual-lens Treatment of Ureteral Stenosis after Ureteral Stone Surgery
11
作者 Qing Wang 《Journal of Clinical and Nursing Research》 2024年第7期146-151,共6页
Objective:To investigate the clinical effect of dual-lens combined treatment of ureteral stenosis after ureteral stone surgery.Methods:The study period was from January 2023 to December 2023,and the sample was selecte... Objective:To investigate the clinical effect of dual-lens combined treatment of ureteral stenosis after ureteral stone surgery.Methods:The study period was from January 2023 to December 2023,and the sample was selected from 76 patients with ureteral stenosis after ureteral stone surgery admitted to our hospital,which was randomly grouped into the experimental group(n=38)and the control group(n=38)by using the numerical table lottery method.The control group was treated with urethroplasty,and the experimental group was treated with a dual-lens combination,comparing the intraoperative blood loss,postoperative recovery time,hospitalization time,and complication rate between the two groups.Results:The intraoperative blood loss,postoperative recovery time and hospitalization time of the experimental group were lower than those of the control group(P<0.05);the complication rate of the experimental group was lower than that of the control group(P<0.05).Conclusion:Dual-lens combined treatment can reduce intraoperative blood loss,shorten postoperative recovery time and hospital stay and reduce the incidence of complications,which has the value of popularization and application. 展开更多
关键词 Dual-lens combination Ureteral stone Ureteral stenosis
下载PDF
Management of urethral strictures and stenosis caused by the endo-urological treatment of benign prostatic hyperplasiad-a single-center experience 被引量:1
12
作者 Rajiv N.Kore 《Asian Journal of Urology》 CSCD 2023年第2期137-143,共7页
Objective:Urethral stricture disease after endo-urological treatment of benign prostatic hyperplasia(BPH)is a sparsely described complication.We describe management of five categories of these strictures in this retro... Objective:Urethral stricture disease after endo-urological treatment of benign prostatic hyperplasia(BPH)is a sparsely described complication.We describe management of five categories of these strictures in this retrospective observational case series.Methods:One hundred and twenty-one patients presenting with symptoms of bladder outflow obstruction after endo-urological intervention for BPH from February 2016 to March 2019 were evaluated.Among them,76 were eligible for this study and underwent reconstructive surgery.Preoperative and postoperative assessments were done with symptom scores,uroflowmetry,ultrasound for post-void residue,and urethrogram.Any intervention during follow-up was classed as a failure.The recurrence and 95%confidence interval for recurrence percentage were calculated.Results:The following five categories of patients were identified:Bulbo-membranous(33[43.4%]),navicular fossa(21[27.6%]),penile/peno-bulbar(8[10.5%]),bladder neck stenosis(6[7.9%]),and multiple locations(8[10.5%]).The average age was 69 years(range:60-84 years).Overall average symptom score,flow rate,and post-void residue changed from 21 to 7,6 mL/s to 19 mL/s,and 210 mL to 20 mL,respectively.The average follow-up was 34 months(range:12-58 months).Overall recurrence and complication rates were 10.5%and 9.2%,respectively.The recurrence in each category was seen in 3,1,2,1,and 1 patient,respectively.Overall 95% confidence interval for recurrence percentage was 4.66-19.69.Conclusion:Urethral stricture disease is a major long-term complication of endo-urological treatment of BPH.The bulbo-membranous strictures need continence preserving approach.Navicular fossa strictures require minimally invasive and cosmetic consideration.Peno-bulbar strictures require judicious use of grafts and flaps.Bladder neck stenosis in this cohort could be treated with endoscopic measures.Multiple locations need treatment based on their sites in single-stage as far as possible. 展开更多
关键词 Urethral stricture Benign prostatic hyperplasia Transurethral resection of prostate URETHROPLASTY Holmium laser enucleation of prostate Trans-urethral bipolar electro-enucleation Bladder neck stenosis
下载PDF
Early hemodynamics after tibial transverse transport in patients with nonarterial stenosis and arterial stenosis diabetic foot 被引量:1
13
作者 Mei-Mei Liao Sen Chen +5 位作者 Jia-Rui Cao Meng-Wei Wang Zhi-Hui Jin Jia Ye Yi-Jun Ren Rui-Qiang Guo 《World Journal of Diabetes》 SCIE 2023年第12期1784-1792,共9页
BACKGROUND The diagnosis of peripheral arteriopathy in the diabetic foot is complicated by diabetes and its advanced complications.It has been found that diabetic foot can be categorized into arterial stenosis and non... BACKGROUND The diagnosis of peripheral arteriopathy in the diabetic foot is complicated by diabetes and its advanced complications.It has been found that diabetic foot can be categorized into arterial stenosis and non-arterial stenosis,both of which have significant differences in hemodynamic characteristics.AIM To evaluate the early hemodynamic changes in diabetic foot patients with nonarterial stenosis and arterial stenosis treated by tibial transverse transport(TTT)using high-frequency color Doppler ultrasonography(HFCDU)and a laser Doppler flowmeter.METHODS Twenty-five patients with Wagner grades 3-5 diabetic foot ulcers were treated with TTT,and the wound healing time and rate were recorded.Patients were grouped according to the results of preoperative lower-extremity ultrasonography.Cases with≥50%stenosis in any of the femoral,popliteal,posterior tibial,anterior tibial,and peroneal arteries of the affected limb were classified as the arterial stenosis group(n=16);otherwise,they were classified as the nonarterial stenosis group(n=9).Before and one month after surgery,HFCDU was used to evaluate the degree of lower limb artery lesions and hemodynamic changes in patients.The degree of femoral-popliteal atherosclerotic stenosis,the degree of vascular stenosis and occlusion of the lower-knee outflow tract,and the degree of medial arterial calcification were scored;the three scores were added together to obtain the total score of lower extremity arteriopathy.PeriScanPIM3,a laser Doppler flowmeter system,was used to detect alterations in plantar microcirculation before and 1 mo after surgery.Wound healing and hemodynamic indices were compared between the two groups.RESULTS The wound healing time of the diabetic foot was significantly shorter in the nonarterial stenosis group than in the arterial stenosis group(47.8±13 vs 85.8±26,P<0.05),and the wound healing rate of both groups was 100%.The preoperative total lower extremity arteriopathy scores were lower in the nonarterial stenosis group than those in the arterial stenosis group(18.89±8.87 vs 24.63±3.52,P<0.05).The nonarterial stenosis group showed higher preoperative popliteal artery(POA)blood flow than the arterial stenosis group(204.89±80.76 cc/min vs 76.75±48.49 cc/min,P<0.05).Compared with the baseline(before surgery),the postoperative POA blood flow of the affected limb in the nonarterial stenosis group decreased one month after surgery(134.11±47.84 cc/min vs 204.89±80.76 cc/min,P<0.05),while that in the arterial stenosis group increased(98.44±30.73 cc/min vs 61.69±21.70 cc/min,P<0.05).Although the POA blood flow in the arterial stenosis group was obviously improved one month after surgery,it was still lower than that in the nonarterial stenosis group(98.44±30.73 cc/min vs 134.11±47.84 cc/min,P<0.05).The nonarterial stenosis group had higher preoperative plantar microcirculation than the arterial stenosis group(56.1±9.2 vs 33.2±7.5,P<0.05);compared with the baseline,the plantar microcirculation in the arterial stenosis group was significantly improved one month after surgery(51.9±7.2,P<0.05),while that in the nonarterial stenosis group was reduced(35.9±7.2,P<0.05).CONCLUSION Based on preoperative HFCDU findings,diabetic foot patients can be divided into two categories:Those with nonarterial stenosis and those with arterial stenosis,with obvious differences in hemodynamic changes in the early postoperative period between them.In the early stage after TTT,the blood flow volume and velocity and the plantar microcirculation perfusion of the affected limb of the diabetic foot with nonarterial stenosis decreased compared with the baseline,while those of the diabetic foot with arterial stenosis improved significantly compared with the baseline,although both had smoothly healed diabetic foot ulcers. 展开更多
关键词 High-frequency color Doppler ultrasonography Diabetic foot Tibial transverse transport Nonarterial stenosis Arterial stenosis
下载PDF
Association of bone turnover biomarkers with severe intracranial and extracranial artery stenosis in type 2 diabetes mellitus patients 被引量:1
14
作者 Si-Cong Si Wei Yang +3 位作者 Hong-Yu Luo Yi-Xin Ma Huan Zhao Jia Liu 《World Journal of Diabetes》 SCIE 2023年第5期594-605,共12页
BACKGROUND Intracranial and extracranial artery stenosis is associated with cerebral infarction.Vascular calcification and atherosclerosis are the main causes of stenosis and major risk factors for cardiovascular and ... BACKGROUND Intracranial and extracranial artery stenosis is associated with cerebral infarction.Vascular calcification and atherosclerosis are the main causes of stenosis and major risk factors for cardiovascular and cerebrovascular events in patients with type 2 diabetes mellitus(T2DM).Bone turnover biomarkers(BTMs)are associated with vascular calcification,atherosclerosis,glucose,and lipid metabolism.AIM To investigate the association of circulating BTM levels with severe intracranial and extracranial artery stenosis in patients with T2DM.METHODS For this cross-sectional study including 257 T2DM patients,levels of the BTMs serum osteocalcin(OC),C-terminal cross-linked telopeptide of type I collagen(CTX),and procollagen type I N-peptide were measured by electrical chemiluminescent immunoassay,and artery stenosis was assessed by color Doppler and transcranial Doppler.Patients were grouped according to the existence and location(intracranial vs.extracranial)of artery stenosis.Correlations between BTM levels,previous stroke,stenosis location,and glucose and lipid metabolism were analyzed.RESULTS T2DM patients with severe artery stenosis had a higher frequency of previous stroke and levels of all three tested BTMs(all P<0.05)than patients without.Some differences in OC and CTX levels were observed according to the location of artery stenosis.Significant associations were also observed between BTM levels and some glucose and lipid homeostasis parameters.On multivariate logistic regression analysis,all BTMs were significant predictors of artery stenosis in T2DM patients with and without adjustment for confounding factors(all P<0.001),and receiver operating characteristic curve analysis demonstrated the ability of BTM levels to predict artery stenosis in T2DM patients.CONCLUSION BTM levels were found to be independent risk factors for severe intracranial and extracranial artery stenosis and were differentially associated with glucose and lipid metabolism in patients with T2DM.Therefore,BTMs may be promising biomarkers and potential therapeutic targets for artery stenosis. 展开更多
关键词 Bone turnover biomarkers Type 2 diabetes mellitus OSTEOCALCIN C-terminal cross-linked telopeptide of type I collagen Procollagen type I N-peptide Intracranial and extracranial artery stenosis
下载PDF
Magnetic compression anastomosis for sigmoid stenosis treatment:A case report 被引量:1
15
作者 Miao-Miao Zhang Yi Gao +4 位作者 Xiao-Yang Ren Huan-Chen Sha Yi Lyu Fang-Fang Dong Xiao-Peng Yan 《World Journal of Gastrointestinal Endoscopy》 2023年第12期745-750,共6页
BACKGROUND Endoscopic balloon dilation is a minimally invasive treatment for colorectal stenosis.Magnetic compression anastomosis can be applied against gastrointestinal anastomosis.When combined with endoscopy,it off... BACKGROUND Endoscopic balloon dilation is a minimally invasive treatment for colorectal stenosis.Magnetic compression anastomosis can be applied against gastrointestinal anastomosis.When combined with endoscopy,it offers a unique approach to the recanalization of colorectal stenosis.CASE SUMMARY We have reported here the case of a 53-year-old female patient who underwent a descending colostomy due to sigmoid obstruction.Postoperative fistula restoration was not possible in her due to sigmoid stenosis.Accordingly,endoscopicassisted magnetic compression anastomosis for sigmoid stenosis was performed,and the sigmoid stenosis was recanalized 15 d after the surgery.Subsequently,a reduction colostomy was successfully performed after 10 d.CONCLUSION This case report proposes a novel minimally invasive treatment approach for colorectal stenosis. 展开更多
关键词 Colorectal stenosis ENDOSCOPY Magnetic compression anastomosis Magnamosis Magnetosurgery Case report
下载PDF
Novel deformable self-assembled magnetic anastomosis ring for endoscopic treatment of colonic stenosis via natural orifice
16
作者 Miao-Miao Zhang Guang-Bin Zhao +9 位作者 Han-Zhi Zhang Shu-Qin Xu Ai-Hua Shi Jian-Qi Mao Jing-Ci Gai Yu-Han Zhang Jia Ma Yun Li Yi Lyu Xiao-Peng Yan 《World Journal of Gastroenterology》 SCIE CAS 2023年第33期5005-5013,共9页
BACKGROUND Although endoscope-assisted magnetic compression anastomosis has already been reported for colonic anastomosis,there is no report on a single-approach operation using the natural orifice.AIM To design a def... BACKGROUND Although endoscope-assisted magnetic compression anastomosis has already been reported for colonic anastomosis,there is no report on a single-approach operation using the natural orifice.AIM To design a deformable self-assembled magnetic anastomosis ring(DSAMAR)for colonic anastomosis for use in single-approach operation and evaluate its feasibility and safety through animal experiments.METHODS The animal model for colonic stenosis was prepared by partial colonic ligation in eight beagles.The magnetic compression anastomosis of their colonic stricture was performed by endoscopically assisted transanal implantation of the DSAMAR.The anastomotic specimen,obtained 2 wk after the operation,was observed by both the naked eye and a light microscope.RESULTS The DSAMAR was successfully inserted into the proximal end of colon stenosis through the anus.The DSAMAR of seven dogs was successfully transformed into rings,while that of the remaining dog was removed after the first deformation failed.The rings were successfully retransformed after optimization.All animals underwent colonic anastomosis using the DSAMAR.No device-related or procedure-related adverse events were observed.The colostomy specimens of the experimental dogs were obtained 2 wk after the operation.Both gross and histological observations showed good anastomotic healing.CONCLUSION The DSAMAR is a safe and feasible option for the treatment of colon stenosis.Its specific deformation and selfassembly capability maximize the applicability of the minimally invasive treatment. 展开更多
关键词 Magnetic surgery Magnamosis Colonic stenosis Natural orifice ENDOSCOPY
下载PDF
Aortic valve replacement reduces mortality in moderate aortic stenosis:a systematic review and meta-analysis
17
作者 Kyle B Franke Dimple Bhatia +1 位作者 Ross L Roberts-Thomson Peter J Psaltis 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2023年第1期61-67,共7页
BACKGROUND With the introduction of transcatheter aortic valve replacement and an evolving understanding of the natural progression and history of aortic stenosis,the potential for earlier intervention in appropriate ... BACKGROUND With the introduction of transcatheter aortic valve replacement and an evolving understanding of the natural progression and history of aortic stenosis,the potential for earlier intervention in appropriate patients is promising;however,the benefit of aortic valve replacement in moderate aortic stenosis remains unclear.METHODS Pubmed,Embase,and the Cochrane Library databases were searched up until 30th of December 2021 using keywords including moderate aortic stenosis and aortic valve replacement.Studies reporting all-cause mortality and outcomes in early aortic valve replacement(AVR)compared to conservative management in patients with moderate aortic stenosis were included.Hazard ratios were generated using random-effects meta-analysis to determine effect estimates.RESULTS 3470 publications were screened with title and abstract review,which left 169 articles for full-text review.Of these studies,7 met inclusion criteria and were included,totalling 4,827 patients.All studies treated AVR as a time-dependent co-variable in cox-regression multivariate analysis of all-cause mortality.Intervention with surgical or transcatheter AVR was associated with a 45% decreased risk of all-cause mortality(HR=0.55[0.42-0.68],I2=51.5%,P<0.001).All studies were representative of the overall cohort with appropriate sample sizes,with no evidence of publication,detection,or information biases in any of the studies.CONCLUSION In this systematic review and meta-analysis,we report a 45% reduction in all-cause mortality in patients with moderate aortic stenosis who were treated with early aortic valve replacement compared to a strategy of conservative management.Randomised control trials are awaited to determine the utility of AVR in moderate aortic stenosis. 展开更多
关键词 AORTIC stenosis ANALYSIS
下载PDF
Emergency Hybrid Correction in a Newborn with Critical Aortic Valve Stenosis with Acute Pulmonary Edema in the First Hour after Birth
18
作者 Vitaliy Suvorov Vladimir Zaitsev +2 位作者 Nikolay Pilyugov Olga Tereshenko Michail Komissarov 《Congenital Heart Disease》 SCIE 2023年第1期57-65,共9页
Critical aortic valve stenosis in newborns is the cause of a severe clinical condition with the onset of symptoms during first hours after birth.We present a clinical case of a successful surgical correction of a crit... Critical aortic valve stenosis in newborns is the cause of a severe clinical condition with the onset of symptoms during first hours after birth.We present a clinical case of a successful surgical correction of a critical aortic stenosis using a hybrid method applied in a newborn during the first day of life.The infant was diagnosed with a hypoplastic left heart complex with an intact atrial septum(aortic and mitral valves stenosis variant),that led to the cardiogenic shock and acute pulmonary edema.The procedure included bilateral banding of the pulmonary artery branches and atrioseptostomy with stenting of the interatrial septum.The surgery was performed through a median sternotomy. 展开更多
关键词 Critical aortic valve stenosis hybrid correction hybrid Norwood bilateral banding hybrid Norwood procedure acute pulmonary edema intact atrial septum hypoplastic left heart complex
下载PDF
Safety and efficacy of balloon angioplasty compared to stent-basedstrategies with pulmonary vein stenosis:A systematic review and meta-analysis
19
作者 Pradyumna Agasthi Srilekha Sridhara +14 位作者 Pattara Rattanawong Nithin Venepally Chieh-Ju Chao Hasan Ashraf Sai Harika Pujari Mohamed Allam Diana Almader-Douglas Yamini Alla Amit Kumar Farouk Mookadam Douglas L Packer David R Holmes Jr Donald J Hagler Floyd David Fortuin Reza Arsanjani 《World Journal of Cardiology》 2023年第2期64-75,共12页
BACKGROUND Pulmonary vein stenosis(PVS)is an uncommon but known cause of morbidity and mortality in adults and children and can be managed with percutaneous revascularization strategies of pulmonary vein balloon angio... BACKGROUND Pulmonary vein stenosis(PVS)is an uncommon but known cause of morbidity and mortality in adults and children and can be managed with percutaneous revascularization strategies of pulmonary vein balloon angioplasty(PBA)or pulmonary vein stent implantation(PSI).AIM To study the safety and efficacy outcomes of PBA vs PSI in all patient categories with PVS.METHODS We performed a literature search of all studies comparing outcomes of patients evaluated by PBA vs PSI for PVS.We selected all published studies comparing PBA vs PSI for PVS with reported outcomes of restenosis and procedure-related complications in all patient categories.In adults,PVS following atrial fibrillation ablation and in children PVS related to congenital etiology or post-procedural PVS following total or partial anomalous pulmonary venous return repair were included.The patient-centered outcomes were risk of restenosis requiring re-intervention and procedural-related complications.The metaanalysis was performed by computing odds ratios(ORs)using the random effects model based on underlying statistical heterogeneity.RESULTS Eight observational studies treating 768 severe PVS in 487 patients met our inclusion criteria.The age range of patients was 6 months to 70 years and 67%were males.The primary outcome of the re-stenosis requiring re-intervention occurred in 196 of 325 veins in the PBA group and 111 of 443 veins in the PSI group.Compared to PSI,PBA was associated with a significantly increased risk of re-stenosis(OR 2.91,95%CI:1.15-7.37,P=0.025,I2=79.2%).Secondary outcomes of the procedurerelated complications occurred in 7 of 122 patients in the PBA group and 6 of 69 in the PSI group.There were no statistically significant differences in the safety outcomes between the two groups(OR:0.94,95%CI:0.23-3.76,P=0.929,I^(2)=0.0%).CONCLUSION Across all patient categories with PVS,PSI is associated with reduced risk of re-intervention and is as safe as PBA and should be considered first-line therapy for PVS. 展开更多
关键词 Pulmonary veins Pulmonary vein stenosis CONSTRICTION Balloon angioplasty STENTS Drugeluting stents
下载PDF
Post-trans-arterial chemoembolization hepatic necrosis and biliary stenosis: Clinical charateristics and endoscopic approach
20
作者 Silvia Cocca Lorenzo Carloni +5 位作者 Margherita Marocchi Giuseppe Grande Marcello Bianchini Antonio Colecchia Rita Conigliaro Helga Bertani 《World Journal of Clinical Cases》 SCIE 2023年第36期8434-8439,共6页
Liver cancer is the fifth most common tumor and the second highest death-related cancer in the world.Hepatocarcinoma(HCC)represents 90%of liver cancers.According to the Barcelona Clinic Liver Cancer group,different tr... Liver cancer is the fifth most common tumor and the second highest death-related cancer in the world.Hepatocarcinoma(HCC)represents 90%of liver cancers.According to the Barcelona Clinic Liver Cancer group,different treatment options could be offered to patients in consideration of tumor burden,liver function,pa-tient performance status and biochemical marker serum concentration such as alpha-fetoprotein.Trans-arterial chemoembolization(TACE)is the treatment of choice in patients with diagnosis of unresectable HCC not eligible for liver trans-plantation,and preserved arterial supply.TACE is known to be safe and its com-plications are generally mild such as post-TACE syndrome,a self-resolving adverse event that occurs in about 90%of patients after the procedure.However,albeit rarely,more severe adverse events such as biloma,sepsis,hepatic failure,chemoagents induced toxicities,and post-TACE liver necrosis can occur.A prompt diagnosis of these clinical conditions is fundamental to prevent further complications.As a result,biliary stenosis could be a rare post-TACE necrosis complication and can be difficult to manage.Complications from untreated biliary strictures include recurring infections,jaundice,chronic cholestasis,and secon-dary biliary cirrhosis. 展开更多
关键词 HEPATOCARCINOMA Trans-arterial Chemoembolization Biliary stenosis Multistenting
下载PDF
上一页 1 2 38 下一页 到第
使用帮助 返回顶部