To evaluate the diagnostic yield of the procedure, mucosal-incision assisted biopsy (MIAB), for the histological diagnosis of gastric gastrointestinal stromal tumor (GIST), we performed a retrospective review of the 2...To evaluate the diagnostic yield of the procedure, mucosal-incision assisted biopsy (MIAB), for the histological diagnosis of gastric gastrointestinal stromal tumor (GIST), we performed a retrospective review of the 27 patients with suspected gastric GIST who underwent MIAB in our hospitals. Tissue samples obtained by MIAB were sufficient to make a histological diagnosis (diagnostic MIAB) in 23 out of the 27 patients, where the lesions had intraluminal growth patterns. Alternatively, the samples were insufficient (non-diagnosticMIAB) in remaining 4 patients, three of whom had gastric submucosal tumor with extraluminal growth patterns. Although endoscopic ultrasound and fine needle aspiration is the gold standard for obtaining tissue specimens for histological and cytological analysis of suspected gastric GISTs, MIAB can be used as an alternative method for obtaining biopsy specimens of lesions with an intraluminal growth pattern.展开更多
Objective: The aim of this study was to evaluate the utility of an upright-type 11-gauge stereotactic vacuumassisted biopsy device (Mammotome) for the diagnosis of breast microcalcifications Methods: Between May 2001 ...Objective: The aim of this study was to evaluate the utility of an upright-type 11-gauge stereotactic vacuumassisted biopsy device (Mammotome) for the diagnosis of breast microcalcifications Methods: Between May 2001 and October 2005, 154 biopsies in 152 patients with microcalcifications were performed using the upright-type 11-gauge stereotactic vacuum-assisted biopsy device. Patients in whom this biopsy was diagnosed as carcinoma or a borderline lesion, had a subsequent surgical excision of the lesion. Histopathological and radiological features of the two specimens were then compared with each other. Results: Microcalcification was identified on specimen mammograms and microscopic slides in 97.4% of cases. Of 154 Mammotome biopsies 98 (63.6%) were benign, 51 (33.1%) were malignant, 3 (1.9%) showed atypical hyperplasia, and 2 (1.3%) were indeterminate, respectively. Of the 48 cases that received surgical excision, 6 of 36 ductal carcinomas in situ (16.7%) upstaged to invasive ductal carcinoma and 1 of 2 atypical ductal hyperplasias was upstaged to ductal carcinoma in situ. The positive predictive value of the 11-gauge Mammotome for the diagnosis of invasion in breast cancer was 100%. Linear calcification and pleomorphic calcification linear/segmental distribution was reliable indications of malignancy. The mean follow-up time of the benign lesions was 22 months, and without evidence of lesion growth. Complications included vasovagal reactions (6.3%), bleeding (0.6%) and hematoma (2.6%). Conclusion: The upright stereotactic 11-gauge Mammotome procedure is an effective and reliable method for the diagnosis of breast microcalcifications. It has minimal side effects. For lesions diagnosed as ADH or DCIS with the 11-gauge Mammotome, subsequent surgical excision should be performed.展开更多
Vacuum-assisted breast biopsy (VABB) plays a fundamental role in the preoperative assessment of breast lesions pro- viding large histology samples that are useful to define diagnoses and biological parameters to guide...Vacuum-assisted breast biopsy (VABB) plays a fundamental role in the preoperative assessment of breast lesions pro- viding large histology samples that are useful to define diagnoses and biological parameters to guide treatment planning. This technique has been used in our institute since 2000 and two new wireless handheld ultrasound-guided VABB de- vices have been introduced since May 2012. In this report we analyze our experience with these revolutionary devices which are able to provide the option of single-insertion contiguous tissue samples respectively with a 13/14-gauge aperture. Our initial experience on 75 lesions shows that these devices are safe, fast, procedurally advantageous for operators and well accepted by patients. Finally VABB procedures can markedly reduce the need for surgical biopsy.展开更多
Objective To compare and evaluate the efficacy of diagnosis and excision for appropriately selected breast multi-focal lesions and solitary lesion by ultrasound-guided vacuum-assisted biopsy(UGVAB).Methods Among 392 a...Objective To compare and evaluate the efficacy of diagnosis and excision for appropriately selected breast multi-focal lesions and solitary lesion by ultrasound-guided vacuum-assisted biopsy(UGVAB).Methods Among 392 appropriately selected patients,187 patients with multi-focal lesions and 205 patients with solitary lesion were treated by the 8-gauge UGVAB from May 2007 to June 2009.All lesions were removed as completely as possible.The patients with benign pathology underwent physical and ultrasound examinations at one week and 6 months after procedure.Results During the procedure,only three patients had vasovagal syncope and twenty others complained of other intraoperative discomfort.An accurate pathological diagnosis was obtained in all lesions.There was no apparent false-negative result among the 696 lesions with benign pathology at a follow-up of 6 months after procedure.The rates of malignant or premalignant pathology,postoperative complications and residual lesions in patients with multi-focal lesions were higher than those in patients with solitary lesion.If each lesion was considered as a subject of study,there was no significant difference between the two groups.Conclusion UGVAB is an effective method for diagnosis and excision of appropriately selected breast multi-focal lesions and can be used routinely.展开更多
Purpose: To investigate a robot assistance device for CT-guided percutan liver biopsy. Materials and Methods: The liver of a corpse was equipped with target dummies. Four radiologists used a 16 G needle to perform bio...Purpose: To investigate a robot assistance device for CT-guided percutan liver biopsy. Materials and Methods: The liver of a corpse was equipped with target dummies. Four radiologists used a 16 G needle to perform biopsy of the target region in standard free hand technique and then used a robot system which allowed planning and aligning the trajectory path. Accuracy in terms of needle tip deviation, and time efficiency and radiation exposure in terms of effective dose for the radiologists were measured. Results: For in plane procedures, there was no significant benefit in accuracy when using the robot versus standard technique (4 mm vs. 5.6 mm, p = 0.11);timely effort was worse (443 sec vs. 405 sec, p = 0.64). For angulated punctures, a needle tip of 3.7 mm was measured by using the robotic device (vs. 10.8 mm, p < 0.01);mean biopsy duration was 490 sec (vs. 900 sec, p < 0.01). Mean radiation exposures in freehand technique were 2.4 μSv (in plane procedures) and 10.8 μSv (oblique procedures);the robotic assisted procedures were performed without additional image guidance. Conclusion: The proposed robotic assistance device may be superior for angulated interventions regarding accuracy and timely effort. Furthermore, the zero radiation exposure is a significant benefit for the interventional radiologist.展开更多
AIM:To analyze the safety and the adequacy of a sample of liver biopsies(LB)obtained by gastroenterologist(G)and interventional radiologist(IR)teams.METHODS:Medical records of consecutive patients evaluated at our GI ...AIM:To analyze the safety and the adequacy of a sample of liver biopsies(LB)obtained by gastroenterologist(G)and interventional radiologist(IR)teams.METHODS:Medical records of consecutive patients evaluated at our GI unit from 01/01/2004 to31/12/2010 for whom LB was considered necessary to diagnose and/or stage liver disease,both in the setting of day hospital and regular admission(RA) care,were retrieved and the data entered in a database.Patients were divided into two groups:one undergoing an ultrasonography(US)-assisted procedure by the G team and one undergoing US-guided biopsy by the IR team.For the first group,an intercostal approach(US-assisted) and a Menghini modified type needle 16 G(length 90 mm) were used.The IR team used a subcostal approach(US-guided) and a semiautomatic modified Menghini type needle 18 G(length 150 mm).All the biopsies were evaluated for appropriateness according to the current guidelines.The number of portal tracts present in each biopsy was assessed by a revision performed by a single pathologist unaware of the previous pathology report.Clinical,laboratory and demographic patient characteristics,the adverse events rate and the diagnostic adequacy of LB were analyzed.RESULTS:During the study period,226 patients,126 males(56%) and 100 females(44%),underwent LB:167(74%) were carried out by the G team,whereas 59(26%) by the IR team.LB was mostly performed in a day hospital setting by the G team,while IR completed more procedures on inpatients(P < 0.0001).The groups did not differ in median age,body mass index(BMI),presence of comorbidities and coagulation parameters.Complications occurred in 26 patients(16 G team vs 10 IR team,P = 0.15).Most gross samples obtained were considered suitable for basal histological evaluation,with no difference among the two teams(96.4% G team vs 91.5% IR,P = 0.16).However,the samples obtained by the G team had a higher mean number of portal tracts(G team 9.5 ± 4.8; range 1-29 vs IR team 7.8 ± 4.1; range 1-20)(P = 0.0192) and a longer mean length(G team 22 mm ± 8.8 vs IR team 15 ± 6.5 mm)(P = 0.0001).CONCLUSION:LB can be performed with similar outcomes both by G and IR.Use of larger dimension needles allows obtaining better samples,with a similar rate of adverse events.展开更多
文摘To evaluate the diagnostic yield of the procedure, mucosal-incision assisted biopsy (MIAB), for the histological diagnosis of gastric gastrointestinal stromal tumor (GIST), we performed a retrospective review of the 27 patients with suspected gastric GIST who underwent MIAB in our hospitals. Tissue samples obtained by MIAB were sufficient to make a histological diagnosis (diagnostic MIAB) in 23 out of the 27 patients, where the lesions had intraluminal growth patterns. Alternatively, the samples were insufficient (non-diagnosticMIAB) in remaining 4 patients, three of whom had gastric submucosal tumor with extraluminal growth patterns. Although endoscopic ultrasound and fine needle aspiration is the gold standard for obtaining tissue specimens for histological and cytological analysis of suspected gastric GISTs, MIAB can be used as an alternative method for obtaining biopsy specimens of lesions with an intraluminal growth pattern.
基金Supported by a grant from the Sasakawa Foundation (Japan) of Japan China Medical Association
文摘Objective: The aim of this study was to evaluate the utility of an upright-type 11-gauge stereotactic vacuumassisted biopsy device (Mammotome) for the diagnosis of breast microcalcifications Methods: Between May 2001 and October 2005, 154 biopsies in 152 patients with microcalcifications were performed using the upright-type 11-gauge stereotactic vacuum-assisted biopsy device. Patients in whom this biopsy was diagnosed as carcinoma or a borderline lesion, had a subsequent surgical excision of the lesion. Histopathological and radiological features of the two specimens were then compared with each other. Results: Microcalcification was identified on specimen mammograms and microscopic slides in 97.4% of cases. Of 154 Mammotome biopsies 98 (63.6%) were benign, 51 (33.1%) were malignant, 3 (1.9%) showed atypical hyperplasia, and 2 (1.3%) were indeterminate, respectively. Of the 48 cases that received surgical excision, 6 of 36 ductal carcinomas in situ (16.7%) upstaged to invasive ductal carcinoma and 1 of 2 atypical ductal hyperplasias was upstaged to ductal carcinoma in situ. The positive predictive value of the 11-gauge Mammotome for the diagnosis of invasion in breast cancer was 100%. Linear calcification and pleomorphic calcification linear/segmental distribution was reliable indications of malignancy. The mean follow-up time of the benign lesions was 22 months, and without evidence of lesion growth. Complications included vasovagal reactions (6.3%), bleeding (0.6%) and hematoma (2.6%). Conclusion: The upright stereotactic 11-gauge Mammotome procedure is an effective and reliable method for the diagnosis of breast microcalcifications. It has minimal side effects. For lesions diagnosed as ADH or DCIS with the 11-gauge Mammotome, subsequent surgical excision should be performed.
文摘Vacuum-assisted breast biopsy (VABB) plays a fundamental role in the preoperative assessment of breast lesions pro- viding large histology samples that are useful to define diagnoses and biological parameters to guide treatment planning. This technique has been used in our institute since 2000 and two new wireless handheld ultrasound-guided VABB de- vices have been introduced since May 2012. In this report we analyze our experience with these revolutionary devices which are able to provide the option of single-insertion contiguous tissue samples respectively with a 13/14-gauge aperture. Our initial experience on 75 lesions shows that these devices are safe, fast, procedurally advantageous for operators and well accepted by patients. Finally VABB procedures can markedly reduce the need for surgical biopsy.
文摘Objective To compare and evaluate the efficacy of diagnosis and excision for appropriately selected breast multi-focal lesions and solitary lesion by ultrasound-guided vacuum-assisted biopsy(UGVAB).Methods Among 392 appropriately selected patients,187 patients with multi-focal lesions and 205 patients with solitary lesion were treated by the 8-gauge UGVAB from May 2007 to June 2009.All lesions were removed as completely as possible.The patients with benign pathology underwent physical and ultrasound examinations at one week and 6 months after procedure.Results During the procedure,only three patients had vasovagal syncope and twenty others complained of other intraoperative discomfort.An accurate pathological diagnosis was obtained in all lesions.There was no apparent false-negative result among the 696 lesions with benign pathology at a follow-up of 6 months after procedure.The rates of malignant or premalignant pathology,postoperative complications and residual lesions in patients with multi-focal lesions were higher than those in patients with solitary lesion.If each lesion was considered as a subject of study,there was no significant difference between the two groups.Conclusion UGVAB is an effective method for diagnosis and excision of appropriately selected breast multi-focal lesions and can be used routinely.
文摘Purpose: To investigate a robot assistance device for CT-guided percutan liver biopsy. Materials and Methods: The liver of a corpse was equipped with target dummies. Four radiologists used a 16 G needle to perform biopsy of the target region in standard free hand technique and then used a robot system which allowed planning and aligning the trajectory path. Accuracy in terms of needle tip deviation, and time efficiency and radiation exposure in terms of effective dose for the radiologists were measured. Results: For in plane procedures, there was no significant benefit in accuracy when using the robot versus standard technique (4 mm vs. 5.6 mm, p = 0.11);timely effort was worse (443 sec vs. 405 sec, p = 0.64). For angulated punctures, a needle tip of 3.7 mm was measured by using the robotic device (vs. 10.8 mm, p < 0.01);mean biopsy duration was 490 sec (vs. 900 sec, p < 0.01). Mean radiation exposures in freehand technique were 2.4 μSv (in plane procedures) and 10.8 μSv (oblique procedures);the robotic assisted procedures were performed without additional image guidance. Conclusion: The proposed robotic assistance device may be superior for angulated interventions regarding accuracy and timely effort. Furthermore, the zero radiation exposure is a significant benefit for the interventional radiologist.
文摘AIM:To analyze the safety and the adequacy of a sample of liver biopsies(LB)obtained by gastroenterologist(G)and interventional radiologist(IR)teams.METHODS:Medical records of consecutive patients evaluated at our GI unit from 01/01/2004 to31/12/2010 for whom LB was considered necessary to diagnose and/or stage liver disease,both in the setting of day hospital and regular admission(RA) care,were retrieved and the data entered in a database.Patients were divided into two groups:one undergoing an ultrasonography(US)-assisted procedure by the G team and one undergoing US-guided biopsy by the IR team.For the first group,an intercostal approach(US-assisted) and a Menghini modified type needle 16 G(length 90 mm) were used.The IR team used a subcostal approach(US-guided) and a semiautomatic modified Menghini type needle 18 G(length 150 mm).All the biopsies were evaluated for appropriateness according to the current guidelines.The number of portal tracts present in each biopsy was assessed by a revision performed by a single pathologist unaware of the previous pathology report.Clinical,laboratory and demographic patient characteristics,the adverse events rate and the diagnostic adequacy of LB were analyzed.RESULTS:During the study period,226 patients,126 males(56%) and 100 females(44%),underwent LB:167(74%) were carried out by the G team,whereas 59(26%) by the IR team.LB was mostly performed in a day hospital setting by the G team,while IR completed more procedures on inpatients(P < 0.0001).The groups did not differ in median age,body mass index(BMI),presence of comorbidities and coagulation parameters.Complications occurred in 26 patients(16 G team vs 10 IR team,P = 0.15).Most gross samples obtained were considered suitable for basal histological evaluation,with no difference among the two teams(96.4% G team vs 91.5% IR,P = 0.16).However,the samples obtained by the G team had a higher mean number of portal tracts(G team 9.5 ± 4.8; range 1-29 vs IR team 7.8 ± 4.1; range 1-20)(P = 0.0192) and a longer mean length(G team 22 mm ± 8.8 vs IR team 15 ± 6.5 mm)(P = 0.0001).CONCLUSION:LB can be performed with similar outcomes both by G and IR.Use of larger dimension needles allows obtaining better samples,with a similar rate of adverse events.