Objective:To study the effect of repetitive peripheral magnetic stimulation(rPMS)combined with conventional rehabilitation measures on shoulder dysfunction in early stroke.Methods:60 patients with shoulder dysfunction...Objective:To study the effect of repetitive peripheral magnetic stimulation(rPMS)combined with conventional rehabilitation measures on shoulder dysfunction in early stroke.Methods:60 patients with shoulder dysfunction in early stroke were selected,and all of them were admitted to our hospital from August 2021 to August 2023.The patients were randomly grouped into a control group(conventional rehabilitation measures intervention,30 cases)and an intervention group(rPMS and conventional rehabilitation measures intervention,30 cases)according to the lottery method.The pain scores,shoulder mobility,and motor function scores of the two groups were compared.Results:The pain score was lower in the intervention group,and the shoulder mobility and motor function scores were higher in the intervention group(P<0.05)as compared to that of the control group.Conclusion:The effect of combining rPMS and conventional rehabilitation measures in treating shoulder dysfunction in early stroke was remarkable and should be popularized.展开更多
Objectives: The goal of this study was to compare the results of evaluating the success of spinal cord stimulation (SCS) using the Visual Analog Scale (VAS) and a Scaling Pain Relief (SPR) measurement. Methods: This p...Objectives: The goal of this study was to compare the results of evaluating the success of spinal cord stimulation (SCS) using the Visual Analog Scale (VAS) and a Scaling Pain Relief (SPR) measurement. Methods: This prospective study included 29 patients, who were considered good candidates for an SCS trial. In the immediate post trial period, immediate post implant period, and one-month post implant period, pain relief was assessed by VAS percent change and using an SPR measurement (direct patient report of pain relief). Statistical analysis of the results included a repeated measures analysis of variance (ANOVA) comparing VAS percent change versus direct patient report of percentage of pain relief (SPR) at the post trial, post implant, and one month follow-ups for all patients that received a permanent implant. Results: Twenty-one patients had a successful trial and 20 were implanted with a permanent system. There was a strong positive correlation between the two pain relief measures at every measured timepoint. Direct patient reports of percentage of pain relief (SPR) were statistically higher than VAS percent change at the post trial period. Seven patients were considered good candidates for implantation based on the SPR measurement, but not VAS percent reduction. These patients went on to achieve clinically significant changes. Discussion: SPR measurements such as direct patient reports of pain relief should be considered in place of VAS percent change when determining SCS trial success.展开更多
In-situ measurement of internal solitary waves(ISWs)is complicated in the ocean due to their randomness.At present,the ISWs are mainly detected by the chain structure of conductivity-temperature-depth systems(CTDs)or ...In-situ measurement of internal solitary waves(ISWs)is complicated in the ocean due to their randomness.At present,the ISWs are mainly detected by the chain structure of conductivity-temperature-depth systems(CTDs)or temperature sensors.The high cost limits the spatial resolution,which ultimately affects the measuring accuracy of the ISW amplitude.In this paper,we developed an experimental measurement system for detecting ISWs based on the stimulated Raman scattering in distributed optical fibers.This system has the advantages of high precision,low cost,and easy operation.The experimental results show that the system is consistent with CTDs in the measurement of vertical ocean temperature variation.The spatial resolution of the system can reach 1.0 m and the measuring accuracy of temperature is 0.2℃.We successfully detected 3 ISWs by the system in the South China Sea and two optical remote sensing images collected on May 18,2021,the same day of two detected ISWs,verify the occurrence of the measured ISWs.We used the image pairs method to calculate the phase velocity of ISW and the result is 1.71 ms^(-1).By extracting the distances between wave packets,it can be found that the semi-diurnal tide generates the detected ISWs.The impact of the tidal current velocity on the ISW in amplitude is undeniable.Undoubtedly,the system has a great application prospect for detecting ISWs and other dynamic phenomena in the ocean.展开更多
Alkaline earth sulfides (MgS,CaS and BaS) crystal doped with rare-earth ions is an optically stimulated luminescence dosimeter with very high sensitivity,short time constant of the optically stimulated luminescence (O...Alkaline earth sulfides (MgS,CaS and BaS) crystal doped with rare-earth ions is an optically stimulated luminescence dosimeter with very high sensitivity,short time constant of the optically stimulated luminescence (OSL) separated perfectly from the stimulation.In this paper,an OSL dosimeter is described.It has linear dose response from 0.01 to 1000 Gy.The equipment,relatively simple and small in size is promising for applications in space exploration and for high dose irradiation and dangerous irradiation conditions.展开更多
We present a method by which to determine the bulk viscosity of water from pulse duration measurements of stimulated Brillouin scattering (SBS). Beginning from a common model of Brillouin scattering, the bulk viscos...We present a method by which to determine the bulk viscosity of water from pulse duration measurements of stimulated Brillouin scattering (SBS). Beginning from a common model of Brillouin scattering, the bulk viscosity is shown to play an important role in Brillouin linewidth determination. Pulse durations of SBS back-reflected optical pulses are measured over the temperature range of 5-40℃. SBS linewidths are de- termined via Fourier transformation of the time-domain results, and the bulk viscosity of water is measured and derived from the obtained values. Our results show that the proposed method for measurement of pulse durations is an effective approach for determining bulk viscosity. The method can be easily extended to determine bulk viscosities of other Newtonian liquids.展开更多
文摘Objective:To study the effect of repetitive peripheral magnetic stimulation(rPMS)combined with conventional rehabilitation measures on shoulder dysfunction in early stroke.Methods:60 patients with shoulder dysfunction in early stroke were selected,and all of them were admitted to our hospital from August 2021 to August 2023.The patients were randomly grouped into a control group(conventional rehabilitation measures intervention,30 cases)and an intervention group(rPMS and conventional rehabilitation measures intervention,30 cases)according to the lottery method.The pain scores,shoulder mobility,and motor function scores of the two groups were compared.Results:The pain score was lower in the intervention group,and the shoulder mobility and motor function scores were higher in the intervention group(P<0.05)as compared to that of the control group.Conclusion:The effect of combining rPMS and conventional rehabilitation measures in treating shoulder dysfunction in early stroke was remarkable and should be popularized.
文摘Objectives: The goal of this study was to compare the results of evaluating the success of spinal cord stimulation (SCS) using the Visual Analog Scale (VAS) and a Scaling Pain Relief (SPR) measurement. Methods: This prospective study included 29 patients, who were considered good candidates for an SCS trial. In the immediate post trial period, immediate post implant period, and one-month post implant period, pain relief was assessed by VAS percent change and using an SPR measurement (direct patient report of pain relief). Statistical analysis of the results included a repeated measures analysis of variance (ANOVA) comparing VAS percent change versus direct patient report of percentage of pain relief (SPR) at the post trial, post implant, and one month follow-ups for all patients that received a permanent implant. Results: Twenty-one patients had a successful trial and 20 were implanted with a permanent system. There was a strong positive correlation between the two pain relief measures at every measured timepoint. Direct patient reports of percentage of pain relief (SPR) were statistically higher than VAS percent change at the post trial period. Seven patients were considered good candidates for implantation based on the SPR measurement, but not VAS percent reduction. These patients went on to achieve clinically significant changes. Discussion: SPR measurements such as direct patient reports of pain relief should be considered in place of VAS percent change when determining SCS trial success.
基金National Natural Science Foundation of China(Nos.61871353,62031005)。
文摘In-situ measurement of internal solitary waves(ISWs)is complicated in the ocean due to their randomness.At present,the ISWs are mainly detected by the chain structure of conductivity-temperature-depth systems(CTDs)or temperature sensors.The high cost limits the spatial resolution,which ultimately affects the measuring accuracy of the ISW amplitude.In this paper,we developed an experimental measurement system for detecting ISWs based on the stimulated Raman scattering in distributed optical fibers.This system has the advantages of high precision,low cost,and easy operation.The experimental results show that the system is consistent with CTDs in the measurement of vertical ocean temperature variation.The spatial resolution of the system can reach 1.0 m and the measuring accuracy of temperature is 0.2℃.We successfully detected 3 ISWs by the system in the South China Sea and two optical remote sensing images collected on May 18,2021,the same day of two detected ISWs,verify the occurrence of the measured ISWs.We used the image pairs method to calculate the phase velocity of ISW and the result is 1.71 ms^(-1).By extracting the distances between wave packets,it can be found that the semi-diurnal tide generates the detected ISWs.The impact of the tidal current velocity on the ISW in amplitude is undeniable.Undoubtedly,the system has a great application prospect for detecting ISWs and other dynamic phenomena in the ocean.
基金National Natural Science Foundation of China (10475112)Western Light Foundation of 2005 years
文摘Alkaline earth sulfides (MgS,CaS and BaS) crystal doped with rare-earth ions is an optically stimulated luminescence dosimeter with very high sensitivity,short time constant of the optically stimulated luminescence (OSL) separated perfectly from the stimulation.In this paper,an OSL dosimeter is described.It has linear dose response from 0.01 to 1000 Gy.The equipment,relatively simple and small in size is promising for applications in space exploration and for high dose irradiation and dangerous irradiation conditions.
基金supported by the National Natural Sci-ence Foundation of China under Grants Nos.41206084 and 61177096
文摘We present a method by which to determine the bulk viscosity of water from pulse duration measurements of stimulated Brillouin scattering (SBS). Beginning from a common model of Brillouin scattering, the bulk viscosity is shown to play an important role in Brillouin linewidth determination. Pulse durations of SBS back-reflected optical pulses are measured over the temperature range of 5-40℃. SBS linewidths are de- termined via Fourier transformation of the time-domain results, and the bulk viscosity of water is measured and derived from the obtained values. Our results show that the proposed method for measurement of pulse durations is an effective approach for determining bulk viscosity. The method can be easily extended to determine bulk viscosities of other Newtonian liquids.