The giant stress-impedance (GSI) effect in amorphous and current annealed Fe73.5Cu1Nb3Si13.5B9 ribbons has been investigated. The results showed that the GSI effect changed drastically with annealing techniques and th...The giant stress-impedance (GSI) effect in amorphous and current annealed Fe73.5Cu1Nb3Si13.5B9 ribbons has been investigated. The results showed that the GSI effect changed drastically with annealing techniques and the maximum stress impedance ratio of 350% was obtained after optimal conditions of current annealing. The behaviors of the stress impedance vary with densities of annealing current and the stress longitudinally applied during current annealing. The maximum change of stress impedance existed in the sample annealed by high-current-density electropulsing under applied stress of 100 MPa.展开更多
The giant stress-impedance (GSI) effect in as-cast and DC current annealed Co71.8Fe4.9 Nb0.8Si7.5 B15 amorphous glass-covered wires is presented. The SI ratio of the as-cast sample exhibits negative GSI effect. For ...The giant stress-impedance (GSI) effect in as-cast and DC current annealed Co71.8Fe4.9 Nb0.8Si7.5 B15 amorphous glass-covered wires is presented. The SI ratio of the as-cast sample exhibits negative GSI effect. For the sample annealed by 60 mA DC current, the SI ratio first increases with applied tensile stress, then decreases. The maximum ΔZ/Z ratio of 304% is obtained. Frequency dependence in the range from 1 to 110 MHz of the GSI effect is investigated. Experimental results show that the real part R and the imaginary part X of impedance play an important role at high frequency and low frequency, respectively. At 1 MHz, the maximum AX/X ratio of 1448% is obtained. At 110 MHz, the maximum AR/R ratio of 648% is obtained.展开更多
The stress-impedance effect in Fe73.5Cu1Nb3Si13.5B9 (at%) ribbons is measured to investigate the influences of vacuum annealing and pressure stress. The results can be explained by the influence of induced anisotropy ...The stress-impedance effect in Fe73.5Cu1Nb3Si13.5B9 (at%) ribbons is measured to investigate the influences of vacuum annealing and pressure stress. The results can be explained by the influence of induced anisotropy in the magnetization processes at the chosen drive current frequency of 90 MHz. The maximum S/% value of the ribbon annealed at 300°C is 2.52%.展开更多
Composite films of different contents were prepared by Fe73.5Cu1Nb3Si13.5B9 powder as compound phase and silicone rubber as matrix phase. The thickness of film is 200 μm. Values of impedance, Z, under pressure stress...Composite films of different contents were prepared by Fe73.5Cu1Nb3Si13.5B9 powder as compound phase and silicone rubber as matrix phase. The thickness of film is 200 μm. Values of impedance, Z, under pressure stress were measured by TH2816LCR digital bridge. LYYL-500N high-grade-type microcomputer control pressure testing machine was used to conduct program control loading with a speed of 0.1 mm·min^-1. The results show that composite films of different contents (25 vol%, 30 vol%, and 35 vol%) have excellent force-sensitive properties in both loading process and unloading process, especially when the stress is below 0.2 MPa, the stress- impedance (SI) and +|k| values of composite films are much higher than that in the range of 0.2-1.0 MPa. The force- sensitive properties of loading process are superior to unloading process. While the frequency is 1 kHz, the force-sensitive properties of composite films are better than 50 kHz. The optimal temperature of powder heat treatment is 500 ℃. Composite film which was prepared by this kind of powder has a good force-sensitive property.展开更多
基金This work was supported by the National Natural ScienceFoundation of China (Grant No.5017106).
文摘The giant stress-impedance (GSI) effect in amorphous and current annealed Fe73.5Cu1Nb3Si13.5B9 ribbons has been investigated. The results showed that the GSI effect changed drastically with annealing techniques and the maximum stress impedance ratio of 350% was obtained after optimal conditions of current annealing. The behaviors of the stress impedance vary with densities of annealing current and the stress longitudinally applied during current annealing. The maximum change of stress impedance existed in the sample annealed by high-current-density electropulsing under applied stress of 100 MPa.
文摘The giant stress-impedance (GSI) effect in as-cast and DC current annealed Co71.8Fe4.9 Nb0.8Si7.5 B15 amorphous glass-covered wires is presented. The SI ratio of the as-cast sample exhibits negative GSI effect. For the sample annealed by 60 mA DC current, the SI ratio first increases with applied tensile stress, then decreases. The maximum ΔZ/Z ratio of 304% is obtained. Frequency dependence in the range from 1 to 110 MHz of the GSI effect is investigated. Experimental results show that the real part R and the imaginary part X of impedance play an important role at high frequency and low frequency, respectively. At 1 MHz, the maximum AX/X ratio of 1448% is obtained. At 110 MHz, the maximum AR/R ratio of 648% is obtained.
基金Supported by the National Natural Science Foundation of China (Grant No. 10576014)
文摘The stress-impedance effect in Fe73.5Cu1Nb3Si13.5B9 (at%) ribbons is measured to investigate the influences of vacuum annealing and pressure stress. The results can be explained by the influence of induced anisotropy in the magnetization processes at the chosen drive current frequency of 90 MHz. The maximum S/% value of the ribbon annealed at 300°C is 2.52%.
基金financially supported by the National Natural Science Foundation of China(No.60961001)the National Natural Science Foundation of China and China Academy of Engineering Physics Joint Funds(No.11076016)the AdvanceResearch of National Basic Research Program of China(No. 2010CB635112)
文摘Composite films of different contents were prepared by Fe73.5Cu1Nb3Si13.5B9 powder as compound phase and silicone rubber as matrix phase. The thickness of film is 200 μm. Values of impedance, Z, under pressure stress were measured by TH2816LCR digital bridge. LYYL-500N high-grade-type microcomputer control pressure testing machine was used to conduct program control loading with a speed of 0.1 mm·min^-1. The results show that composite films of different contents (25 vol%, 30 vol%, and 35 vol%) have excellent force-sensitive properties in both loading process and unloading process, especially when the stress is below 0.2 MPa, the stress- impedance (SI) and +|k| values of composite films are much higher than that in the range of 0.2-1.0 MPa. The force- sensitive properties of loading process are superior to unloading process. While the frequency is 1 kHz, the force-sensitive properties of composite films are better than 50 kHz. The optimal temperature of powder heat treatment is 500 ℃. Composite film which was prepared by this kind of powder has a good force-sensitive property.