期刊文献+
共找到24篇文章
< 1 2 >
每页显示 20 50 100
Comparative Studies on Detection of Antibodies against Infectious Bursal Disease Virus with Test Strips and Agar Gel Immunodiffusion Method
1
作者 张进良 张文通 +3 位作者 胡思顺 毕丁仁 王喜亮 肖运才 《Agricultural Science & Technology》 CAS 2012年第9期1826-1828,共3页
[Objective] This study aimed to compare the detection results of antibodies against infectious bursal disease virus with test strips and agar gel immunodiffusion method. [Method] Antibodies against infectious bursal d... [Objective] This study aimed to compare the detection results of antibodies against infectious bursal disease virus with test strips and agar gel immunodiffusion method. [Method] Antibodies against infectious bursal disease virus in chicken serum were detected using test strips developed in our laboratory, and the results were comparad^with that using traditional agar diffusion method. [Result] The comparative study of the two methods showed that the sensitivity of test strips was eight times over agar gel immunodiffusion; test strips showed higher detection rate in the deter- mination test of 216 clinical samples, with high specificity, easy preservation, and simple and rapid operation, thereby being more suitable for the monitoring of clinical antibodies. [Conclusion] Test strips could replace the existing serological methods, having great promotion and application value in antibody monitoring. 展开更多
关键词 Infectious bursal disease Agar gel immunodiffusion test strips
下载PDF
A dual-RPA based lateral flow strip for sensitive,on-site detection of CP4-EPSPS and Cry1Ab/Ac genes in genetically modified crops 被引量:1
2
作者 Jinbin Wang Yu Wang +7 位作者 Xiuwen Hu Yifan Chen Wei Jiang Xiaofeng Liu Juan Liu Lemei Zhu Haijuan Zeng Hua Liu 《Food Science and Human Wellness》 SCIE CSCD 2024年第1期183-190,共8页
Traditional transgenic detection methods require high test conditions and struggle to be both sensitive and efficient.In this study,a one-tube dual recombinase polymerase amplification(RPA)reaction system for CP4-EPSP... Traditional transgenic detection methods require high test conditions and struggle to be both sensitive and efficient.In this study,a one-tube dual recombinase polymerase amplification(RPA)reaction system for CP4-EPSPS and Cry1Ab/Ac was proposed and combined with a lateral flow immunochromatographic assay,named“Dual-RPA-LFD”,to visualize the dual detection of genetically modified(GM)crops.In which,the herbicide tolerance gene CP4-EPSPS and the insect resistance gene Cry1Ab/Ac were selected as targets taking into account the current status of the most widespread application of insect resistance and herbicide tolerance traits and their stacked traits.Gradient diluted plasmids,transgenic standards,and actual samples were used as templates to conduct sensitivity,specificity,and practicality assays,respectively.The constructed method achieved the visual detection of plasmid at levels as low as 100 copies,demonstrating its high sensitivity.In addition,good applicability to transgenic samples was observed,with no cross-interference between two test lines and no influence from other genes.In conclusion,this strategy achieved the expected purpose of simultaneous detection of the two popular targets in GM crops within 20 min at 37°C in a rapid,equipmentfree field manner,providing a new alternative for rapid screening for transgenic assays in the field. 展开更多
关键词 Genetically modifi ed crops On-site detection Lateral fl ow test strips Dual recombinase polymerase amplification (RPA)
下载PDF
Rapid testing methods for food contaminants and toxicants 被引量:7
3
作者 Jiachi Chiou Arthur Ho Hon Leung +1 位作者 Hang Wai Lee Wing-tak Wong 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2015年第11期2243-2264,共22页
Food safety is one of the major concerns in every country regardless of the economic and social development. The frequent occurrence of food scandals in the world has led the Chinese government to implement several st... Food safety is one of the major concerns in every country regardless of the economic and social development. The frequent occurrence of food scandals in the world has led the Chinese government to implement several strategies to fortify the food supply system to a high food safety standard. This relies heavily on laboratory testing services but conventional methods for detection of food contaminants and toxicants are limited by sophisticated sample preparation procedures, long analysis time, large instruments and professional personnel to meet the increasing demands. In this review, we have incorporated most of the current and potential rapid detection methods for many notorious food contaminants and toxicants including microbial agents, toxic ions, pesticides, veterinary drugs and preservatives, as well as detection of genetically modified food genes and adulterated edible oil. Development of rapid, accurate, easy-to-use and affordable testing methods could urge food handlers and the public to actively screen for food contaminants and toxicants instead of passively relying on monitoring by the government examination facility. This review also provides several recommendations including how to encourage the public to engage in the food safety management system and provide optimal education and financial assistance that may improve the current Chinese food safety control system. 展开更多
关键词 rapid testing food contaminants and toxins microbial agents PESTICIDES veterinary drugs PRESERVATIVES FORMALDEHYDE NITRITE nitrate test strips
下载PDF
Evaluation of Abuse Drugs and Clinical Laboratory Tests Variations in Whole Blood & Urine Samples of Abusers 被引量:1
4
作者 Majid Rezaei Basiri Mojgan Behshid +9 位作者 Alireza Najafi Saleh Alilou Haniyeh Mohebbi-Kamali: Fatemeh Hosseindoust Marziyeh Mokhtari Valiyollah Watani Ladan Aminzadeh Fatemeh Seyed Nejad Ashraf Razavi Ligha Saadat 《Journal of Pharmacy and Pharmacology》 2018年第1期69-76,共8页
In this study, five hundred urine samples and five hundred blood samples of abusers were examined for the presence of alkaloid substances and abuse drugs in urines and bloods. These numbers of blood and urine samples ... In this study, five hundred urine samples and five hundred blood samples of abusers were examined for the presence of alkaloid substances and abuse drugs in urines and bloods. These numbers of blood and urine samples of addicts in clinics of welfare organization, during detoxification treatment or maintenance treatment were screened for abuse drugs presence. The all of samples were tested through as a view of clinical laboratory methods. Age ranges of female patients were 35 ~ 15 and age range of males patients were 45 ~ 15. All patients filled questionnaire and satisfy forms too. First, all fresh urine and blood samples were examined to confirm presence drugs abuses, depend on their addiction and treatment, so all samples were confirmed by two tests. Then they were examined to other clinical laboratory tests. All data were analyzed by t-test and were Anova one way and two ways of Anova Turkey, and p 〈 0.05 was considered significant. The p-value of this study was p = 0.0001. The results of this study were showed that 4% of abusers had mild increase in hematocrite level and 2% of narcotic drugs abusers had mild lower level of blood sugars than normal range and 4% of participants had increase liver enzymes such ALT (alanine transferase), AST (aspartat transferase), ALP (alkaline phosphatease) and 1% of them had renal failure. Although blood level BUN (blood urea nitrogen) and creatinin were examined to evaluation of their renal failure .The results in Tabriz/Iran undrevision of welfare organization clinics were approximately showed that positive results of addiction are in each of urine and blood samples. Because some of abusers directly consumed full long time agonist or partial agonists' drugs such as methadone and buprenorphine for their maintenance therapy in clinics. Also doing test on blood samples has high importance in distinguishing and confirmation of drugs abuse in samples. Also in this study we conclude that among all drug analytical methods the cheapest and easiest test to screening opioids and other abuse drugs in urine and blood samples is strip test for rapid diagnosis, also tests on blood samples have high importance as a view point of accuracy to distinguishing of drugs abuse, and serum levels of some other parameters showed all abusers patients situation such as liver and renal dysfimction through clinical laboratory tests. 展开更多
关键词 Abusers urine and whole blood samples strip test thin-layer chromatography abuse drugs clinical laboratory tests.
下载PDF
An Immunochromatographic Strip Test for Rapid Detection of Antibodies against Porcine Circovirus Type 2
5
作者 ZHANG Wen-tong WEI Feng +2 位作者 WANG Jin-liang XIAO Yue-qiang SHEN Zhi-qiang 《Animal Husbandry and Feed Science》 CAS 2011年第5期26-29,共4页
Porcine cimovirus type 2 (PCV2) infection causes huge economic losses, but no serological method is available for batch detection of field samples. The aim of the study was to develop a method for large-batch detectio... Porcine cimovirus type 2 (PCV2) infection causes huge economic losses, but no serological method is available for batch detection of field samples. The aim of the study was to develop a method for large-batch detection of PCV2 infection. Colloidal gold-labeled staphylococcal protein A (SPA) was sprayed on glass fibers to prepare a conjugate pad. The recombinant ORF2 protein of PCV2 was blotted on the test line of the nitrocellulose (NC) membrane, and pig IgG was streaked on the control line of the NC membrane. Then, the immunochromatographic strip was used for detection of antibodies against PCV2. The results show that the strip test was simple and the results could be determined within 10 min with naked eyes. The test strip was highly specific for pig serum against PCV2 and no cross-reaction with pig serum against other pathogens was observed. The test strip had close similarity with ELISA. Storage at RT for 6 months did not affect the specificity and sensitivity obviously. A total of 324 clinical pig sera were detected by both ELISA and the developed test strip, and the coincidence was 98.77%. Therefore, the developed immunochromatographic strip is specific, sensitive, stable, fast and simple, and it is suitable for on-site detection of antibodies against PCV2. 展开更多
关键词 Porcine circovirus type 2 IMMUNOCHROMATOGRAPHY test strip
下载PDF
Evaluation of the immunochromatographic strip test for the rapid diagnosis of antenatal syphilis in women in Eldoret,Kenya
6
作者 Lydia B. Nyamwamu Michael M. Gicheru +3 位作者 Rekha R. Sharma lbert Kimutai Willy K.Tonui Peter Kamau Ngure 《Journal of Nanjing Medical University》 2009年第5期317-321,共5页
Objective: This study compared the performance of the immunochromatographic strip (ICS) to the Venereal Disease Research Laboratory (VDRL) test and Treponema pallidum haemagglutination assay (TPHA) at a primary... Objective: This study compared the performance of the immunochromatographic strip (ICS) to the Venereal Disease Research Laboratory (VDRL) test and Treponema pallidum haemagglutination assay (TPHA) at a primary health care setting. Methods: The study group was comprised of 150 females randomly drawn from a population of pregnant women attending their first antenatal visit or follow-up visits at West Maternity Hospital in Eldoret Kenya, but without a previous syphilis test during that pregnancy. On-site VDRL, ICS and TPHA tests were performed and immediate treatment provided where appropriate. The performance of the three tests was compared, Results: The sero-prevalence of syphilis as determined by the VDRL test was 3%. There was no significant difference between the ICS and the VDRL test (P 〉 0.05). The sensitivity and specificity of the ICS test were 80% and 98.6% respectively, while the negative predictive value (NPV) and positive predictive value (PPV) were both 100%. On the other hand, the sensitivity and specificity of the VDRL test were 66.7% and 99.3%, while the NPV and PPV were 80% and 98.6% respectively. The Treponema pallidum haemagglutination assay was used as a reference test and had sensitivity, specificity, NPV and PPV of 100%. Conclusion: The diagnostic accuracy of the ICS compared favorably with theVDRL gold standard. The use of the ICS in Kenya can improve the diagnosis of syphilis in health facilities both with and without laboratories and allow community health care workers to make a rapid diagnosis of the disease, and consequently make immediate therapeutic decisions. 展开更多
关键词 SYPHILIS Immunochromatographic strip test Venereal Disease Research Laboratory Treponema Pa//idum haemagglutinationAssay SPECIFICITY Sensitivity Positive Predictive Value Negative Predictive Value antenatal syphilis
下载PDF
''Blue Dream Pregnancy Test Strip''For Detecting Early Pregnancy
7
《China Population Today》 1996年第Z1期32-32,共1页
''BlueDreamPregnancyTestStrip''ForDetectingEarlyPregnancy¥//ServingtheImprovementofReproductiveHealthofWomen... ''BlueDreamPregnancyTestStrip''ForDetectingEarlyPregnancy¥//ServingtheImprovementofReproductiveHealthofWomenAndtheHappinessof... 展开更多
关键词 test Blue Dream Pregnancy test Strip For Detecting Early Pregnancy
下载PDF
Determination of the Friction Coefficient in the Flat Strip Drawing Test
8
作者 Anvar Makhkamov 《Engineering(科研)》 2021年第11期595-604,共10页
Current work is focused on the influence of friction in deep drawing process. Friction measurements were also conducted using a modified tribotester based on strip sliding between tools. Four different tool surfaces w... Current work is focused on the influence of friction in deep drawing process. Friction measurements were also conducted using a modified tribotester based on strip sliding between tools. Four different tool surfaces were tested under similar contact conditions regarding contact area, normal pressure, sliding speed, lubricant and surface characteristics to calculate the friction coefficient between the tool surface and a high strength low alloy steel sheet HSLA 380. The results showed that friction coefficient varies over a wide range with different lubricating conditions and different sliding velocities. For some sliding velocities, the coefficient of friction is stable and low, while for others it is unstable and higher. Results of the experiments reveal that this novel tribotester is a very useful tool to evaluate and compare the friction between steel sheet and tool surfaces in alloyed steel for cold working applications. The outcomes have only small dispersion within the different test series, which indicates a stable process with good repeatability. The test method enables comparison of different surface finishes and treatments, lubricants and coatings in terms of friction and galling under conditions similar to those found in sheet metal forming processes. The four different types of surfaces considered for this study were grinded, polished, nitrided and quenched/tempered. The main difference among the tested tools in this work was the surface roughness, which was found to have a strong influence on friction. 展开更多
关键词 TRIBOLOGY Friction ROUGHNESS Sheet Metal Forming LUBRICANT Steel Sheet Tool Surface Coefficient of Friction Normal Force Sliding Speed Contact Pressure Strip Drawing test
下载PDF
Visual test paper based on Au/δ-MnO_(2) hollow nanosphere oxidase-like activity regulation using hexavalent chromium as a smart switch
9
作者 Wen-Chang Zhuang Hai-Yue Zhang +4 位作者 Zhen-Yang Chen Wen-Jing Cheng Wei-Dan Na Zhao Li Lin Tian 《Rare Metals》 SCIE EI CAS CSCD 2024年第2期711-722,共12页
Paper-based sensing platform is a point of need analytical toolkit for safety testing.However,the sensitivity,specificity,and simplicity are still challenging.Herein,we report a novel strategy(Au/δ-MnO_(2) hollow nan... Paper-based sensing platform is a point of need analytical toolkit for safety testing.However,the sensitivity,specificity,and simplicity are still challenging.Herein,we report a novel strategy(Au/δ-MnO_(2) hollow nanosphere and 3,3′,5,5′-tetramethylbenzidine(TMB)induced test strips for signal-on detection)that can be utilized for hexavalent chromium(Cr^(6+))detection.Interestingly,Cr^(6+)(CrO_(4)^(2−)) as a smart switch can remarkably enhance the oxidase-like activity of Au/δ-MnO_(2) hollow nanosphere.The presence of Cr^(6+) can regulate the surface electronic redistribution of Au/δ-MnO_(2) and adjust the geometric configuration,which leads to the improvement in oxidase-like activity of Au/δ-MnO_(2).As a proof-of-concept application,a visual paper-based sensing platform of Cr^(6+) along with quantitative analysis by the test strips was successfully constructed.This paper-based sensing platform exhibits a linear range with excellent selectivity for other interfering substances and lower limit of detection of 0.09μmol·L^(−1),providing a promising toolkit at-home Cr^(6+) measurement and environmental monitoring. 展开更多
关键词 Point of need Colorimetric biosensing platform Au/δ-MnO_(2) hollow nanosphere test strip Cr^(6+)
原文传递
三种方法评估替加环素对多重耐药鲍曼不动杆菌体外药敏结果分析 被引量:8
10
作者 代鑫露 黄松音 李红玉 《现代检验医学杂志》 CAS 2020年第3期103-106,共4页
目的比较3种药敏检测方法检测替加环素对多重耐药鲍曼不动杆菌敏感性的差异。方法收集2018年临床分离耐碳青霉烯类鲍曼不动杆菌60株,采用MIC Test Strip(MTS)法、VITEK-2法、纸片扩散法分别检测替加环素对耐碳青霉烯类鲍曼不动杆菌的敏... 目的比较3种药敏检测方法检测替加环素对多重耐药鲍曼不动杆菌敏感性的差异。方法收集2018年临床分离耐碳青霉烯类鲍曼不动杆菌60株,采用MIC Test Strip(MTS)法、VITEK-2法、纸片扩散法分别检测替加环素对耐碳青霉烯类鲍曼不动杆菌的敏感性。结果按照FDA标准,以MTS法为参考,VITEK-2法的一致率较高,纸片扩散法的一致率较低。Vitek-2法的MIC值比MTS法的MIC值低1~2个稀释度,利用MTS法检测替加环素对耐碳青霉烯鲍曼不动杆菌的耐药率达到23.3%,出现耐药株。结论对于耐碳青霉烯类鲍曼不动杆菌,Vitek-2法和纸片扩散法均不适合检测替加环素的敏感性,不能作为常规方法,需用MTS法确认。 展开更多
关键词 替加环素 鲍曼不动杆菌 纸片扩散法 MIC test Strip法(MTS法) VITEK-2法
下载PDF
To form AIE product with the target analyte:a new strategy for excellent fluorescent probes,and convenient detection of hydrazine in seconds with test strips 被引量:1
11
作者 Yuchen Song Luyi Zong +1 位作者 Liyao Zhang Zhen Li 《Science China Chemistry》 SCIE EI CAS CSCD 2017年第12期1596-1601,共6页
A new hydrazine probe was designed, which demonstrates ultrafast "turn-on" response towards hydrazine both in solution and as gas, due to the excellent AIE(aggregation-induced emission) characteristic of the... A new hydrazine probe was designed, which demonstrates ultrafast "turn-on" response towards hydrazine both in solution and as gas, due to the excellent AIE(aggregation-induced emission) characteristic of the yielded products. Excitedly, the corresponding fabricated test strips can report the presence of trace hydrazine as low as 10 nmol/L in aqueous medium in seconds conveniently,with very high selectivity in the pH value ranging from 3.0 to 14.0. 展开更多
关键词 hydrazine probe test strips aggregation-induced emission
原文传递
Distinguishing of Abuse Drugs in Urine and Blood Samples of Abusers in Iran 被引量:1
12
作者 Rezaei-Basiri Majid Behshid Mojgan +6 位作者 Ghazi-Khansari Mahmoud Tabatabaei Seyed Mahmoud Moradi Danesh Alilu Saleh Jabbarzadeh Aahad Mokhtari Marziyeh Bahari Afrouz 《Journal of Pharmacy and Pharmacology》 2015年第8期385-390,共6页
In this study, one hundred urine samples and one hundred blood samples of abusers were examined for the presence of alkaloid substances and abuse drugs in urines and bloods. These numbers of blood and urine samples re... In this study, one hundred urine samples and one hundred blood samples of abusers were examined for the presence of alkaloid substances and abuse drugs in urines and bloods. These numbers of blood and urine samples referred who addicts in clinics of Welfare Organization, during of detoxification treatment or maintenance treatment were screened for abuse drugs presence. Age ranges of female patients were 35 ± 15 and age range of males patients were 42 ± 18. All patients filled questionnaire and satisfy forms too. All data were analyzed by t-test and were Anowa one way, and P 〈 0.05 was considered significant. The P value of this study was P = 0.000. In this study we conclude that among all drug analytical methods the cheapest and easiest test to screening opioids and other abuse drugs in urine and blood samples is strip test for rapid diagnosis and TLC (thin-layer chromatography) is appropriate confirmation method to drug abuse distinguishing. Also tests on blood samples have high importance as a view point of accuracy to distinguishing of drugs abuse. 展开更多
关键词 Abusers urine and blood samples Strip test Thin-layer chromatography abuse drugs.
下载PDF
Dual-readout test strips platform for portable and highly sensitive detection of alkaline phosphatase in human serum samples
13
作者 Juanzu Liu Hongmin Meng +6 位作者 Lin Zhang Shasha Li Juan Chen Yi Zhang Jianjun Li Lingbo Qu Zhaohui Li 《Chinese Chemical Letters》 SCIE CAS CSCD 2021年第11期3421-3425,共5页
In this work,a very simple dual-readout lateral flow test strip(LFTS)platform was developed for sensitive detection of alkaline phosphatase(ALP)based on a portable device.In this assay,quantum dots(QDs)conjugated with... In this work,a very simple dual-readout lateral flow test strip(LFTS)platform was developed for sensitive detection of alkaline phosphatase(ALP)based on a portable device.In this assay,quantum dots(QDs)conjugated with bovine serum albumin(QDs-BSA)were chosen as fluorescence signal labels.In the absence of ALP,MnO_(2)nanosheets aggregate on the test line and exhibit an obvious brown color,which can be observed by naked eyes to realize semi-qualitative analysis.Meanwhile,fluorescence intensity of QDs-BSA can also be effectively quenched by MnO_(2)nanosheets due to inner-filter effect.Correspondingly,in the presence of ALP,ALP can catalyze the hydrolysis of ascorbic acid 2-phosphate(AAP)to generate L-ascorbic acid(AA),which can reduce MnO_(2)into Mn^(2+),accompanying with the obvious fluorescence recovery of the QDs.By simply monitoring the change of colorimetric and fluorescent signal on the test line,trace amount of ALP can be quantitatively detected.Under the optimal conditions,measurable evaluation of ALP was reached in a linear range from 1 U/L to 20 U/L with a detection limit of 0.7 U/L based on fluorescence signal.Furthermore,this colorimetric/fluorescent dual-readout assay was successfully applied to monitor ALP in human serum samples,showing its great potential as a point of care biosensor for clinical diagnosis. 展开更多
关键词 Lateral flow test strip MnO^(2)nanosheets Quantum dots Dual-readout Alkaline phosphatase
原文传递
Application of Nanomaterials in the Rapid Detection of Pathogenic Microorganisms
14
作者 Shenyan SHI Xiaojuan NIE +6 位作者 Dong HUANG Danni ZHAO Jiazhen MEI Tao LI Liyuan ZHANG Rui QIAN Peng LYU 《Agricultural Biotechnology》 CAS 2021年第3期76-79,82,共5页
Pathogenic microorganisms can cause infectious diseases in the human body and cause harm to humans.Under the continuous changes of human life style,sudden infectious diseases and sudden pathogenic microbial contaminat... Pathogenic microorganisms can cause infectious diseases in the human body and cause harm to humans.Under the continuous changes of human life style,sudden infectious diseases and sudden pathogenic microbial contamination in food have brought great challenges to human health.Traditional pathogenic microorganism detection is mainly carried out in laboratories with low speed,and requires experienced operators,which greatly affects the detection efficiency,and real-time monitoring cannot be achieved in the face of epidemics or food contamination.In response to these new situations,new on-site rapid detection methods have become a must,but to achieve the purpose of on-site rapid and immediate detection,higher requirements have been put forward to sensitivity and specificity.Due to their special photoelectric properties and adsorption properties,nanomaterials have gradually been applied in on-site rapid detection methods such as biosensors,and some substantial progress has been made.In this study,we introduced the actual application of nanomaterials in testing and their applications in on-site rapid testing,and made some prospects for the development of on-site rapid testing methods. 展开更多
关键词 NANOMATERIALS Rapid on-site testing test strip technology
下载PDF
Evaluation of Mass Drug Administration Impact on Transmission of Lymphatic Filariasis in 13 Sanitary Districts in Burkina Faso
15
作者 Nomtondo Amina Ouedraogo Sidnoma Muriel Ouedraogo +7 位作者 Gilbert Patrice Tapsoba WRoland Bougma Mamadou Serme Apollinaire Kima Nadia Kaboret Ibrahim Sangare Clarisse Bougouma Francois Drabo 《Journal of Cosmetics, Dermatological Sciences and Applications》 2018年第4期185-194,共10页
Introduction: Lymphatic filariasis (LF) is one of the neglected tropical diseases targeted for elimination as a public health issue in the world by 2020. To achieve this goal, one of the strategies is interruption of ... Introduction: Lymphatic filariasis (LF) is one of the neglected tropical diseases targeted for elimination as a public health issue in the world by 2020. To achieve this goal, one of the strategies is interruption of transmission using chemotherapy (mass drug administration). Burkina Faso in west Africa, an endemic country, has endorsed this resolution. In 2000, all Sanitary Districts (SD) in the country were endemic, and then a national elimination program has made it possible to stop mass treatment in 45 out of 70 SD over 12 years. Sixteen years later, 13 other SD were reeligible for Transmission Assessment Surveys (TAS). This study aimed to determine the current level of the Mass drugs Administration (MDA) impact indicators in these 13 targeted SD in order to decide whether we need to continue MDA. Method: It was a descriptive study that took place from June to September 2017 in 13 SD regrouped into 7 Evaluation Units (EU). The population of the study was 6 to 7 years old children. The community-based cluster survey method was used. The diagnostic test used to detect Wuchereria bancrofti’s circulating antigen (W. bancrofti) is the Filariasis Test Strip (FTS). The critical threshold of positivity was set at 18 positive subjects per EU. Results: We sampled a total of 12,060 children, 48.9% were female and 51.1% male. In the 7 EU, 13 children were positive to W. bancrofti test. The average antigenic prevalence was 0.11% (13/12,060). In all EU, the number of positive subjects was below the critical threshold. Conclusion: At the end of this evaluation of the transmission of lymphatic filariasis in 13 SD of Burkina Faso, we can tell the MDA could be stopped in these areas without risk of resurgence of the disease, according to the current recommendations of WHO. This can be possible by setting up post-TMM surveillance, considering migratory flows, and including villages where positive cases were found to search possible residual transmission zones. 展开更多
关键词 Transmission Assessment Survey (TAS) Mass Drug Administration Filariasis test Strip
下载PDF
Research on an innovative structure of an open-ribbed steel-ultra-high performance concrete composite bridge deck
16
作者 Xudong SHAO Xuan SUN +2 位作者 Deqiang ZOU Junhui CAO Chuanqi YANG 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2024年第5期716-730,共15页
To completely solve the problem of fatigue cracking issue of orthotropic steel bridge decks(OSDs),the authors proposed a steel–ultra-high performance concrete(UHPC)lightweight composite deck(LWCD)with closed ribs in ... To completely solve the problem of fatigue cracking issue of orthotropic steel bridge decks(OSDs),the authors proposed a steel–ultra-high performance concrete(UHPC)lightweight composite deck(LWCD)with closed ribs in 2010.Based on the successful application of that LWCD,an adaptation incorporating an innovative composite deck structure,i.e.,the hot-rolled section steel–UHPC composite deck with open ribs(SSD)is proposed in this paper,aiming to simplify the fabrication process as well as to reduce the cost of LWCD.Based on a long-span cable-stayed bridge,a design scheme is proposed and is compared with the conventional OSD scheme.Further,a finite element(FE)calculation is conducted to reflect both the global and local behavior of the SSD scheme,and it is found that the peaked stresses in the SSD components are less than the corresponding allowable values.A static test is performed for an SSD strip specimen to understand the anti-cracking behavior of the UHPC layer under negative bending moments.The static test results indicate that the UHPC layer exhibited a satisfactory tensile toughness,the UHPC tensile strength obtained from the test is 1.8 times the calculated stress by the FE model of the real bridge.In addition,the fatigue stresses of typical fatigue-prone details in the SSD are calculated and evaluated,and the influences of key design parameters on the fatigue performance of the SSD are analyzed.According to the fatigue results,the peaked stress ranges for all of the 10 fatigue-prone details are within the corresponding constant amplitude fatigue limits.Then a fatigue test is carried out for another SSD strip specimen to explore the fatigue behavior of the fillet weld between the longitudinal and transverse ribs.The specimen failed at the fillet weld after equivalent 47.5 million cycles of loading under the design fatigue stress range,indicating that the fatigue performance of the SSD could meet the fatigue design requirement.Theoretical calculations and experiments provide a basis for the promotion and application of this structure in bridge engineering. 展开更多
关键词 steel-ultra-high performance concrete composite deck open rib strip model test static and fatigue performance orthotropic steel deck
原文传递
Development of a test strip for rapid detection of lactoperoxidase in raw milk 被引量:1
17
作者 Hong-xia CHE Bo TIAN +5 位作者 Li-na BAI Li-ming CHENG Li-li LIU Xiao-na ZHANG Zhan-mei JIANG Xiao-xi XU 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2015年第8期672-679,共8页
Traditional methods for detecting lactoperoxidase (LP) are complex and time-consuming, so a test strip was made based on the enzymatic reaction principle to enable quick and convenient detection of LP in raw milk. I... Traditional methods for detecting lactoperoxidase (LP) are complex and time-consuming, so a test strip was made based on the enzymatic reaction principle to enable quick and convenient detection of LP in raw milk. In this study 0.1 mol/L citric acid (CA)/0.2 mol/L disodium hydrogen phosphate (NAP) buffer solution (pH 5.0), 22 mmol/L 3,3',5,5'-tetramethylbenzidine (TMB), 0.6 mmol/L hydrogen peroxide (H202), and 0.5% Tween-20 or 0.3% cetyltri- methyl ammonium bromide (CTAB) were optimal for preparing a quick, sensitive, and accurate LP test strip. The coefficient of variation (CV) of the estimated LP concentrations ranged from 2.47% to 6.72% and the minimum LP concentration detected by the test strip was 1-2 mg/L. Estimates of active LP in sixteen raw milk samples obtained using the test strip or the TMB method showed a good correlation (c=0.9776). So the test strip provides a quick, convenient, and accurate method for detecting the LP concentration of raw milk. 展开更多
关键词 LACTOPEROXIDASE test strip Rapid detection Raw milk 3 3' 5 5'-Tetramethylbenzidine (TMB)
原文传递
Development of a test strip based on DNA-functionalized gold nanoparticles for rapid detection of mercury(II) ions 被引量:1
18
作者 Jing Duan Zhi Yong Guo 《Chinese Chemical Letters》 SCIE CAS CSCD 2012年第2期225-228,共4页
A rapid,sensitive,selective and reliable strip assay based on DNA-functionalized gold nanoparticles for Hg^(2+) detection has been developed,with a detection limit 5 nmol/L.The measurement principle was based on th... A rapid,sensitive,selective and reliable strip assay based on DNA-functionalized gold nanoparticles for Hg^(2+) detection has been developed,with a detection limit 5 nmol/L.The measurement principle was based on thymine-Hg^(2+)-thymine(T-Hg^(2+)-T) coordination chemistry and streptavidin-biotin interaction.The major advantages of this assay are that results can be read visually without any instrument in less than 10 min and that it does not require any sample pretreatment. 展开更多
关键词 Mercury(Ⅱ) ion test strip Gold nanoparticles DNA
原文传递
Novel ractopamine–protein carrier conjugation and its application to the lateral flow strip test for ractopamine detection in animal feed
19
作者 Pattarachaya PREECHAKASEDKIT Nattaya NGAMROJANAVANICH +1 位作者 Nanthika KHONGCHAREONPORN Orawon CHAILAPAKUL 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2019年第2期193-204,共12页
In this work,a novel conjugate of ractopamine and bovine serum albumin(RAC–BSA)has been developed via the Mannich reaction,with a mole coupling ratio for RAC–BSA of 9:1.The proposed conjugation method provides a sim... In this work,a novel conjugate of ractopamine and bovine serum albumin(RAC–BSA)has been developed via the Mannich reaction,with a mole coupling ratio for RAC–BSA of 9:1.The proposed conjugation method provides a simple and one-step method with the use of fewer reagents compared with other conjugation methods for competitive immunoassays.RAC–BSA conjugation was used to fabricate a competitive lateral flow strip test for RAC detection in animal feed.For sample preparation,RAC was spiked in swine feed purchased from the local markets in Thailand,and methanol and running buffer at a volume ratio of 10:90 was used as extraction buffer.The procedures for sample preparation were completed within 25 min.Under optimal conditions,the limit of detection(LOD),assessed by the naked eye within 5 min,was found to be 1 ng/g.A semi-quantitative analysis was also conducted using a smart phone and computer software,with a linearity of 0.075–0.750 ng/g,calculated LOD of 0.10 ng/g,calculated limit of quantitation of 0.33 ng/g,and good correlation of 0.992.The recoveries were found in the range of 96.4%–103.7%with a relative standard deviation of 2.5%–3.6%for intra-and inter-assays.Comparison of the results obtained by the strip test with those obtained by enzyme-linked immunosorbent assay had a good agreement in terms of accuracy.Furthermore,this strip test exhibited highly specific RAC detection without cross reactivity with related compounds.Therefore,the RAC–BSA conjugation via the Mannich reaction can be accepted as a one-step and easy conjugation method and applied to the competitive lateral flow strip test. 展开更多
关键词 RACTOPAMINE Conjugate of ractopamine and bovine serum albumin (RAC–BSA) Mannich reaction Lateral flow strip test Feed additive
原文传递
Evaluating the Validity of a Nitrate Quick Test in Different Chinese Soils
20
作者 YUE Xian-Lu LI Fei +4 位作者 HU Yun-Cai ZHANG Huai-Zhi JI Hong-Jie ZHANG Wei-Li U. SCHMIDHALTER 《Pedosphere》 SCIE CAS CSCD 2012年第5期623-630,共8页
Because laboratory tests are expensive and time-consuming and may not be available to farmers, soil nitrate quick tests are required for optimal nitrogen management strategies in China to increase nitrogen use efficie... Because laboratory tests are expensive and time-consuming and may not be available to farmers, soil nitrate quick tests are required for optimal nitrogen management strategies in China to increase nitrogen use efficiency and to reduce nitrogen losses. A total of 328 soil samples were collected at different soil depths from 225 sites in China, which covered a wide range of climatic and geographic regions, soil types, croplands and soil textures, to evaluate the suitability of a quick reflectometer test method for analysing soil NO3-N in a wide range of soil NO3 concentrations, soil types and cropping systems in China, mainly by comparison of soil NO3-N assessed by a quick-test method (a reflectometer) and a standard laboratory method, i.e., high-performance liquid chromatography (HPLC). The reflectometer showed excellent agreement with the laboratory HPLC method with regard to soil nitrate contents for all analysed soil samples. The linear regression had slopes of 1 ± 0.08 and intercepts of ± 1.38 mg NO(-,3)-N L^(-1) among different soil types and croplands. Compared with the 1:1 lines, the regression analysis for each soil type showed statistically significant but small differences in slope; the relative difference between the values measured using the two analytical systems varied from -8% to 6%, and there were no differences in intercept except for paddy soil. The reflectometer showed adequate, statistically significant precision in determining soil nitrate contents, and it could therefore be directly used instead of the laboratory methods for soil NO(-,3)-N measurement in China. 展开更多
关键词 DILUTION N recommendation nitrate test strip REFLECTOMETER soil NO(3 -)-N
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部