Removal of Cr(VI) from aqueous solution by strong alkaline anion exchange fiber (SAAEF) was achieved using batch adsorption experiments. The effect of contact time, initial Cr(VI) concentration and pH was invest...Removal of Cr(VI) from aqueous solution by strong alkaline anion exchange fiber (SAAEF) was achieved using batch adsorption experiments. The effect of contact time, initial Cr(VI) concentration and pH was investigated. The results showed that the maximum adsorption capacity of SAAEF was 187.7 mg/g at pH=1.0. The adsorption capacity increased with Cr(VI) concentration but decreased with pH value when pH〉1.0. Adsorption isotherms at various temperatures were obtained. Langmuir, Freundlich, Dubinin-Radushkevich and Temkin models were adopted and the equilibrium data fitted best with the Langmuir isotherm. The constants of these models indicated that the adsorption process involved both chemisorption and physisorption. The values of thermodynamic parameters, including DH, DG and DS, suggested that the adsorption of Cr(VI) on SAAEF was a spontaneous, entropy-driven and endothermic process. Q(iso) was not a constant value, which indicated an inhomogenous energy distribution on SAAEF.展开更多
The urea denatured recombinant human granulocyte colony-stimulating factor (rhG- CSF) which was expressed in Escheriachia coli (E. coli) was refolded with simultaneous purification by strong anion exchange chromatogra...The urea denatured recombinant human granulocyte colony-stimulating factor (rhG- CSF) which was expressed in Escheriachia coli (E. coli) was refolded with simultaneous purification by strong anion exchange chromatography (SAX) in the presence of low concentration- of urea. The effect of urea concentration on this refolding process was investigated. The obtained refolded rhG-CSF has a high specific activity of 2.3×108 U/mg, demonstrating that the proteins were completely refolded during the chromatographic process. With only one step by SAX in 40 min, purity and mass recovery of the refolded and purified rhG-CSF were 97% and 43%, respectively.展开更多
研究了采用ZGA351大孔强碱性阴离子交换树脂从粗钨酸铵溶液中吸附分离钼的工艺方法,考察了树脂型号、料液硫含量、料液陈化时间、料液陈化温度、料液pH值、吸附流速、吸附温度对树脂吸附分离钼效果的影响。结果表明:使用100 mL ZGA351...研究了采用ZGA351大孔强碱性阴离子交换树脂从粗钨酸铵溶液中吸附分离钼的工艺方法,考察了树脂型号、料液硫含量、料液陈化时间、料液陈化温度、料液pH值、吸附流速、吸附温度对树脂吸附分离钼效果的影响。结果表明:使用100 mL ZGA351树脂进行动态吸附试验,在料液硫含量为理论量1.1倍、料液陈化时间48 h、料液陈化温度40℃、料液pH值10.0、吸附流速15 mL/h、吸附温度40℃的最优条件下,料液钨损失率仅为0.54%,树脂钼穿透容量为107.77 g/L_(湿树脂),相比目前工业生产应用的HBDM-1树脂钼穿透容量提高了3.15倍。另外,重复试验稳定性良好,ZGA351树脂吸附后得到的纯钨酸铵溶液平均钼钨比为0.88×10^(-4),满足工业生产APT产品用纯钨酸铵溶液钼钨比小于2×10^(-4)的需求。综合而言,采用强碱性阴离子交换树脂从粗钨酸铵溶液中分离钼具有钼穿透容量高、钨损失率低、钨钼分离效率高等优势,为工业化应用提供了一种有效技术参考。展开更多
基金Project (20080242009) supported by Basic Research Foundation of Beijing Institute of Technology, China
文摘Removal of Cr(VI) from aqueous solution by strong alkaline anion exchange fiber (SAAEF) was achieved using batch adsorption experiments. The effect of contact time, initial Cr(VI) concentration and pH was investigated. The results showed that the maximum adsorption capacity of SAAEF was 187.7 mg/g at pH=1.0. The adsorption capacity increased with Cr(VI) concentration but decreased with pH value when pH〉1.0. Adsorption isotherms at various temperatures were obtained. Langmuir, Freundlich, Dubinin-Radushkevich and Temkin models were adopted and the equilibrium data fitted best with the Langmuir isotherm. The constants of these models indicated that the adsorption process involved both chemisorption and physisorption. The values of thermodynamic parameters, including DH, DG and DS, suggested that the adsorption of Cr(VI) on SAAEF was a spontaneous, entropy-driven and endothermic process. Q(iso) was not a constant value, which indicated an inhomogenous energy distribution on SAAEF.
基金This work is supported by the National Natural Science Foundation of China(No.20175016)
文摘The urea denatured recombinant human granulocyte colony-stimulating factor (rhG- CSF) which was expressed in Escheriachia coli (E. coli) was refolded with simultaneous purification by strong anion exchange chromatography (SAX) in the presence of low concentration- of urea. The effect of urea concentration on this refolding process was investigated. The obtained refolded rhG-CSF has a high specific activity of 2.3×108 U/mg, demonstrating that the proteins were completely refolded during the chromatographic process. With only one step by SAX in 40 min, purity and mass recovery of the refolded and purified rhG-CSF were 97% and 43%, respectively.