期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Study on the interfacial shear behavior of steel reinforced concrete (SRC) members with stud connectors after fire 被引量:2
1
作者 Zihua ZHANG Junhua LI Lei ZHANG Kai YU 《Frontiers of Structural and Civil Engineering》 CSCD 2014年第2期140-150,共11页
Statically push-out tests of 20 steel reinforced concrete short columns (SRCSC) with stud connectors on the surface of shape steel after fire and two SRCSC under ambient temperature were carried out, in order to stu... Statically push-out tests of 20 steel reinforced concrete short columns (SRCSC) with stud connectors on the surface of shape steel after fire and two SRCSC under ambient temperature were carried out, in order to study the failure mode, load-slip relationship and the interfacial shear transfer of SRC members after fire. Experimental results show that the typical failure modes and load-slip curves of SRCSC after fire are almost the same as the case under ambient temperature. The interfacial shear transfer of SRCSC declines exponentially not only with the increase of the peak temperature the specimen experienced but also with the increase of the peak temperature duration. The interfacial shear transfer of the specimens with studs arranged at the steel web is much higher than those with studs arranged at the steel flange. Empirical formulas of SRCSC interfacial shear transfer after fire are proposed, and the calculated results generally agree well with the experimental results. 展开更多
关键词 steel reinforced concrete (SRC) short column stud connector afcer fire interfacial shear transfer
原文传递
Internal Force Distribution in Steel-Concrete Composite Structure for Pylon of Cable-Stayed Bridge 被引量:5
2
作者 蒲黔辉 白光亮 《Journal of Southwest Jiaotong University(English Edition)》 2009年第2期95-101,共7页
Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure... Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure the safety of the steel-concrete composite structure, a stud connector model for the joint section was put forward. Experiments were conducted to obtain the relation between load and slip of specimen, the failure pattern of stud connector, the yield bearing capacity and ultimate bearing capacity of a single stud, etc. The whole process of the structural behavior of the specimen was comprehensively analyzed. The features of the internal force distribution in the steel-concrete composite structure and the strain distribution of stud connector under different loads were emphatically studied. The test results show that the stud connector is applicable for the steel-concrete composite structure for pylon of Jintang bridge. The stud has a good ductility performance and a obvious yield process before its destruction. The stud connector basically works in a state of elasticity under a load less than the yield load. 展开更多
关键词 stud connector Experimental research Steel-concrete composite structure Cable-stayed bridge Internal force distribution
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部