This paper presents a subspace identification method for closed-loop systems with unknown deterministic disturbances.To deal with the unknown deterministic disturbances,two strategies are implemented to construct the ...This paper presents a subspace identification method for closed-loop systems with unknown deterministic disturbances.To deal with the unknown deterministic disturbances,two strategies are implemented to construct the row space that can be used to approximately represent the unknown deterministic disturbances using the trigonometric functions or Bernstein polynomials depending on whether the disturbance frequencies are known.For closed-loop identification,CCF-N4SID is extended to the case with unknown deterministic disturbances using the oblique projection.In addition,a proper Bernstein polynomial order can be determined using the Akaike information criterion(AIC)or the Bayesian information criterion(BIC).Numerical simulation results demonstrate the effectiveness of the proposed identification method for both periodic and aperiodic deterministic disturbances.展开更多
Security during remote transmission has been an important concern for researchers in recent years.In this paper,a hierarchical encryption multi-image encryption scheme for people with different security levels is desi...Security during remote transmission has been an important concern for researchers in recent years.In this paper,a hierarchical encryption multi-image encryption scheme for people with different security levels is designed,and a multiimage encryption(MIE)algorithm with row and column confusion and closed-loop bi-directional diffusion is adopted in the paper.While ensuring secure communication of medical image information,people with different security levels have different levels of decryption keys,and differentiated visual effects can be obtained by using the strong sensitivity of chaotic keys.The highest security level can obtain decrypted images without watermarks,and at the same time,patient information and copyright attribution can be verified by obtaining watermark images.The experimental results show that the scheme is sufficiently secure as an MIE scheme with visualized differences and the encryption and decryption efficiency is significantly improved compared to other works.展开更多
Background: Sub arachnoid block (SAB) performed by traditional landmark palpation technique can be inaccurate. This problem is exacerbated by altered patient anatomy due to obesity and age-related changes. A pre-proce...Background: Sub arachnoid block (SAB) performed by traditional landmark palpation technique can be inaccurate. This problem is exacerbated by altered patient anatomy due to obesity and age-related changes. A pre-procedural ultrasound scan of the lumbar spine has been shown to be of benefit in guiding lumbar epidural insertion in obstetric patients. Information on the use of real-time ultrasound (RUS) guided SAB, to date, been limited. This study compared RUS guided SAB to traditional landmark guided technique in patients undergoing spinal anesthesia for different surgical procedures. Methods: This was a prospective, single center, comparative observational study conducted in the department of anesthesiology at our center. 560 patients who underwent spinal anesthesia either by landmark based technique or real-time ultrasound-guided methods. The primary outcome was the first attempt success rate of dural puncture when employing the two methods. Results: Baseline characteristics were similar in the two study groups. The first attempt success rate of dural puncture in landmark guided group was 64.3% compared to 72.6% in the ultrasound guided group. This difference was not statistically significant. The procedure performance time was significantly shorter with landmark palpation compared to use of real-time ultrasound guided method. Conclusion: Use of RUS-guided technique does not significantly improve the first attempt success rate of SAB dural puncture during spinal anesthesia compared to the traditional landmark-guided technique.展开更多
BACKGROUND In 2016,the Food and Drug Administration approved the first hybrid closed-loop(HCL)insulin delivery system for adults with type 1 diabetes(T1D).There is limited information on the impact of using HCL system...BACKGROUND In 2016,the Food and Drug Administration approved the first hybrid closed-loop(HCL)insulin delivery system for adults with type 1 diabetes(T1D).There is limited information on the impact of using HCL systems on patient-reported outcomes(PROs)in patients with T1D in real-world clinical practice.In this independent study,we evaluated glycemic parameters and PROs over one year of continuous use of Medtronic’s 670G HCL in real-world clinical practice.AIM To assess the effects of hybrid closed loop system on glycemic control and quality of life in adults with T1D.METHODS We evaluated 71 patients with T1D(mean age:45.5±12.1 years;59%females;body weight:83.8±18.7 kg,body mass index:28.7±5.6 kg/m2,A1C:7.6%±0.8%)who were treated with HCL at Joslin Clinic from 2017 to 2019.We measured A1C and percent of glucose time-in-range(%TIR)at baseline and 12 months.We measured percent time in auto mode(%TiAM)for the last two weeks preceding the final visit and assessed PROs through several validated quality-of-life surveys related to general health and diabetes management.RESULTS At 12 mo,A1C decreased by 0.3%±0.1%(P=0.001)and%TIR increased by 8.1%±2.5%(P=0.002).The average%TiAM was only 64.3%±32.8%and was not associated with A1C,%TIR or PROs.PROs,provided at baseline and at the end of the study,showed that the physical functioning submodule of 36Item Short-Form Health Survey increased significantly by 22.9%(P<0.001).Hypoglycemia fear survey/worry scale decreased significantly by 24.9%(P<0.000);Problem Areas In Diabetes reduced significantly by-17.2%(P=0.002).The emotional burden submodules of dietary diversity score reduced significantly by-44.7%(P=0.001).Furthermore,analysis of Clarke questionnaire showed no increase in awareness of hypoglycemic episodes.WHO-5 showed no improvements in subject’s wellbeing among participants after starting the 670G HCL system.Finally,analysis of Pittsburgh Sleep Quality Index showed no difference in sleep quality,sleep latency,or duration of sleep from baseline to 12 mo.CONCLUSION The use of HCL in real-world clinical practice for one year was associated with significant improvements in A1C,%TIR,physical functioning,hypoglycemia fear,emotional distress,and emotional burden related to diabetes management.However,these changes were not associated with time in auto mode.展开更多
In this paper, we modify the Bregman APG<sub>s</sub> (BAPG<sub>s</sub>) method proposed in (Wang, L, et al.) for solving the support vector machine problem with truncated loss (HTPSVM) given in...In this paper, we modify the Bregman APG<sub>s</sub> (BAPG<sub>s</sub>) method proposed in (Wang, L, et al.) for solving the support vector machine problem with truncated loss (HTPSVM) given in (Zhu, W, et al.), we also add an adaptive parameter selection technique based on (Ren, K, et al.). In each iteration, we use the linear approximation method to get the explicit solution of the subproblem and set a function to apply the Bregman distance. Finally, numerical experiments are performed to verify the efficiency of BAPG<sub>s</sub>.展开更多
Angiotensin II (Ang II) is the main mediator of the Renin-Angiotensin-System acting on AT<sub>1</sub> and other AT receptors. It is regarded as a pleiotropic agent that induces many actions, including func...Angiotensin II (Ang II) is the main mediator of the Renin-Angiotensin-System acting on AT<sub>1</sub> and other AT receptors. It is regarded as a pleiotropic agent that induces many actions, including functioning as a growth factor, and as a contractile hormone, among others. The aim of this work was to examine the impact of Ang II on the expression and function of α<sub>1</sub>-adrenergic receptors (α<sub>1</sub>-ARs) in cultured rat aorta, and aorta-derived smooth muscle cells. Isolated Wistar rat aorta was incubated for 24 h in DMEM at 37˚C, then subjected to isometric tension and to the action of added norepinephrine, in concentration-response curves. Ang II was added (1 × 10<sup>−5</sup> M), and in some experiments, 5-Methylurapidil (α<sub>1A</sub>-AR antagonist), AH11110A (α<sub>1B</sub>-AR antagonist), or BMY-7378 (α<sub>1D</sub>-AR antagonist), were used to identify the α<sub>1</sub>-AR involved in the response. Desensitization of the contractile response to norepinephrine was observed due to incubation time, and by the Ang II action. α<sub>1D</sub>-AR was protected from desensitization by BMY-7378;while RS-100329 and prazosin partially mitigated desensitization. In another set of experiments, isolated aorta-derived smooth muscle cells were exposed to Ang II and α<sub>1</sub>-ARs proteins were evaluated. α<sub>1D</sub>-AR increased at 30 and 60 min post Ang II exposure, the α<sub>1A</sub>-AR diminished from 1 to 4 h, while α<sub>1B</sub>-AR remained unchanged over 24 h of Ang II exposure. Ang II induced an increase of α<sub>1D</sub>-AR at short times, and BMY-7378 protected α<sub>1D</sub>-AR from desensitization.展开更多
The lethal dose LD<sub>50</sub> represents the most important experimental value for acute toxicity. The simple logarithmic calculation of -log<sub>10</sub> LD<sub>50</sub> = value ...The lethal dose LD<sub>50</sub> represents the most important experimental value for acute toxicity. The simple logarithmic calculation of -log<sub>10</sub> LD<sub>50</sub> = value leads to the possible poison power pLD. As with the pH or pK value, respectively, for acid or the scale of earthquake intensities the logarithm helps making large differences of orders of magnitude easier to understand since they are more comparable. The higher the pLD value, the higher is the power of poison. An increase of the pLD value by 1 stands for a tenfold increase in toxicity. The lethal acute dose for water, one of the most important and at the same time non-toxic substances of all, is about one tenth of the body weight. This leads to a possible pLD value for water of 1, an ideal starting value for a logarithmic poison scale.展开更多
Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuri...Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuring the quantitative assessment of emissions for informed decisions on environmental treatments. This paper describes a method for the calibration of CO/CO<sub>2</sub> monitors used for periodic inspections of vehicles in cites. The calibration was performed in the selected ranges: 900 - 12,000 µmol/mol for CO and 2000 - 20,000 µmol/mol for CO<sub>2</sub>. The traceability of the measurement results to the SI units was ensured by using certified reference materials from CO/N<sub>2</sub> and CO<sub>2</sub>/N<sub>2</sub> primary gas mixtures. The method performance was evaluated by assessing its linearity, accuracy, precision, bias, and uncertainty of the calibration results. The calibration data exhibited a strong linear trend with R² values close to 1, indicating an excellent fit between the measured values and the calibration lines. Precision, expressed as relative standard deviation (%RSD), ranged from 0.48 to 4.56% for CO and from 0.97 to 3.53% for CO<sub>2</sub>, staying well below the 5% threshold for reporting results at a 95% confidence level. Accuracy measured as percent recovery, was consistently high (≥ 99.1%) for CO and ranged from 84.90% to 101.54% across the calibration range for CO<sub>2</sub>. In addition, the method exhibited minimal bias for both CO and CO<sub>2</sub> calibrations and thus provided a reliable and accurate approach for calibrating CO/CO<sub>2</sub> monitors used in vehicle inspections. Thus, it ensures the effectiveness of exhaust emission control for better environment.展开更多
We report the performances of a chalcopyrite Cu(In, Ga)Se<sub>2 </sub>CIGS-based thin-film solar cell with a newly employed high conductive n-Si layer. The data analysis was performed with the help of the ...We report the performances of a chalcopyrite Cu(In, Ga)Se<sub>2 </sub>CIGS-based thin-film solar cell with a newly employed high conductive n-Si layer. The data analysis was performed with the help of the 1D-Solar Cell Capacitance Simulator (1D-SCAPS) software program. The new device structure is based on the CIGS layer as the absorber layer, n-Si as the high conductive layer, i-In<sub>2</sub>S<sub>3</sub>, and i-ZnO as the buffer and window layers, respectively. The optimum CIGS bandgap was determined first and used to simulate and analyze the cell performance throughout the experiment. This analysis revealed that the absorber layer’s optimum bandgap value has to be 1.4 eV to achieve maximum efficiency of 22.57%. Subsequently, output solar cell parameters were analyzed as a function of CIGS layer thickness, defect density, and the operating temperature with an optimized n-Si layer. The newly modeled device has a p-CIGS/n-Si/In<sub>2</sub>S<sub>3</sub>/Al-ZnO structure. The main objective was to improve the overall cell performance while optimizing the thickness of absorber layers, defect density, bandgap, and operating temperature with the newly employed optimized n-Si layer. The increase of absorber layer thickness from 0.2 - 2 µm showed an upward trend in the cell’s performance, while the increase of defect density and operating temperature showed a downward trend in solar cell performance. This study illustrates that the proposed cell structure shows higher cell performances and can be fabricated on the lab-scale and industrial levels.展开更多
Aim: This study aimed to investigate the protective effects of flavonoids from the stem and leaves of Scutellaria baicalensis Georgi (SSFs) against Aβ<sub>1-42</sub>-induced oligodendrocytes (OL) damage. ...Aim: This study aimed to investigate the protective effects of flavonoids from the stem and leaves of Scutellaria baicalensis Georgi (SSFs) against Aβ<sub>1-42</sub>-induced oligodendrocytes (OL) damage. Methods: Immunofluorescence was used for the detection of myelin-associated glycoprotein (MAG), a characteristic protein of rat oligodendrocytes (OLN-93 cells). To evaluate the potential protective effects of SSFs on OLN-93 cells injured by Aβ<sub>1-42</sub>, an injury model was established by subjecting OLN-93 cells to Aβ<sub>1-42</sub> exposed. Cell morphology was examined using an inverted microscope, while cell viability was assessed using the colorimetric method of 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT). Additionally, lactate dehydrogenase (LDH) was measured using the pyruvic acid reduction assay. The Ginkgo biloba leaf extract (GBE) injection was used as a positive control. Results: A total of >95% of the MAG immunofluorescence-positive cells were identified as oligodendrocytes. Gradually increasing concentrations of SSFs impaired the cells, and the maximum nondetrimental dose for OLN-93 cells was 75 mg/L. This study assessed the effects of SSFs on OLN-93 cells damaged by Aβ<sub>1-42</sub>. The results indicated that SSFs significantly improved OLN-93 cell morphological abnormal changes, increased the OLN-93 cell survival rate, and reduced LDH release. Conclusion: SSFs can alleviate Aβ<sub>1-42</sub>-induced damage of OL.展开更多
Silane coupling agent KH560 was used to modify the surface of nano-α-Al<sub>2</sub>O<sub>3</sub> in ethanol-aqueous solution with different proportions. The particle size of nano-α-Al<sub&...Silane coupling agent KH560 was used to modify the surface of nano-α-Al<sub>2</sub>O<sub>3</sub> in ethanol-aqueous solution with different proportions. The particle size of nano-α-Al<sub>2</sub>O<sub>3</sub> was determined by nano-particle size analyzer, and the effects of nano-α-Al<sub>2</sub>O<sub>3</sub> content, ethanol-aqueous solution ratio and KH560 dosage on the dispersion and particle size of nano-α-Al<sub>2</sub>O<sub>3</sub> were investigated. The material structure before and after modification was determined by Fourier transform infrared spectroscopy (FTIR). Aqueous polyurethane resin and inorganic components are combined with modified nano-α-Al<sub>2</sub>O<sub>3</sub> dispersion to form chromium-free passivation solution. The solution is coated on the galvanized sheet, the adhesion and surface hardness are tested, the bonding strength of the coating and the surface hardness of the substrate are discussed. The corrosion resistance and surface morphology of the matrix were investigated by electrochemical test, neutral salt spray test and scanning electron microscope test. The chromium-free passivation film formed after the modification of nano-α-Al<sub>2</sub>O<sub>3</sub> increases the surface hardness of galvanized sheet by about 85%. The corrosion resistance of the film is better than that of a single polyurethane film. The results show that the surface hardness and corrosion resistance of polyurethane resin composite passivation film are significantly improved by the introduction of nano-α-Al<sub>2</sub>O<sub>3</sub>.展开更多
This research investigates the comparative efficacy of generating zero divisor graphs (ZDGs) of the ring of integers ℤ<sub>n</sub> modulo n using MAPLE algorithm. Zero divisor graphs, pivotal in the study ...This research investigates the comparative efficacy of generating zero divisor graphs (ZDGs) of the ring of integers ℤ<sub>n</sub> modulo n using MAPLE algorithm. Zero divisor graphs, pivotal in the study of ring theory, depict relationships between elements of a ring that multiply to zero. The paper explores the development and implementation of algorithms in MAPLE for constructing these ZDGs. The comparative study aims to discern the strengths, limitations, and computational efficiency of different MAPLE algorithms for creating zero divisor graphs offering insights for mathematicians, researchers, and computational enthusiasts involved in ring theory and mathematical computations.展开更多
This study was aimed to investigate the effects of hydrothermal aging, propene and SO<sub>2</sub> poisoning on the ammonia-selective catalytic reduction (NH<sub>3</sub>-SCR) performance of both...This study was aimed to investigate the effects of hydrothermal aging, propene and SO<sub>2</sub> poisoning on the ammonia-selective catalytic reduction (NH<sub>3</sub>-SCR) performance of both Cu-SAPO-34 and Cu-ZSM-5. The catalytic activities of fresh, aged and poisoned samples were tested in ammonia-selective catalytic reduction (NH<sub>3</sub>-SCR) of NO<sub>x</sub> conditions. The XRD, TG and N<sub>2</sub>-desorption results showed that the structures of the Cu-SAPO-34 and Cu-ZSM-5 remained intact after 750˚C hydrothermally aged, SO<sub>2</sub> and propene poisoned. After hydrothermal aging at 750˚C for 12 h, the NO reduction performance of Cu-ZSM-5 was significantly reduced at lower temperatures, while that of Cu-SAPO-34 was less affected. Moreover, Cu-SAPO-34 catalyst showed high NO conversion with SO<sub>2</sub> or propene compared to Cu-ZSM-5. However, Cu-ZSM-5 showed a larger drop in catalytic activity with SO<sub>2</sub> or propene compared to Cu-SAPO-34 catalyst. The H<sub>2</sub>-TPR results showed that Cu<sup>2 </sup> ions could be reduced to Cu<sup> </sup> and Cu<sup>0</sup> for Cu-ZSM-5, while no significant transformation of copper species was observed for Cu-SAPO-34. Meanwhile, the UV-vis DRS results showed that CuO species were formed in Cu-ZSM-5, while little changes were observed for the Cu-SAPO-34. Cu-SAPO-34 showed high sulfur and hydrocarbon poison resistance compared to Cu-ZSM-5. In summary, Cu-SAPO-34 with small-pore zeolite showed higher hydrothermal stability and better hydrocarbon and sulfur poison resistant than Cu-ZSM-5 with medium-pore.展开更多
Corn rod-like WO<sub>3</sub> nanomaterials were successfully synthesized by a simple hydrothermal method. The morphology, structure and optical absorption properties of the prepared samples were characteri...Corn rod-like WO<sub>3</sub> nanomaterials were successfully synthesized by a simple hydrothermal method. The morphology, structure and optical absorption properties of the prepared samples were characterized by SEM, XRD, FTIR and UV-Vis-DRS. The WO<sub>3</sub> materials were corn rod-like morphology with about 800 nm for length and 150 nm for diameter, especially there were plenty of corn particles (about 20 nm) on the surface of corn rods. The X-ray diffraction peaks of the products corresponded with WO<sub>3</sub> standard card, and the characteristic peak of W-O bond was found in the infrared spectrum. The absorption band edge of the products was about 480 nm, indicating their potential visible-light-induced photocatalytic activity. In situ FTIR technology research showed that the prepared WO<sub>3</sub> nanomaterials had visible photocatalytic activity to gas-phase toluene. After a photocatalytic reaction for 8 hours toluene was effectively degraded, and carboxylic acid and aldehyde could be regarded as the intermediate products, and CO<sub>2</sub> was produced as the final product during the reaction process.展开更多
In this article, we deal with weak solutions to non-degenerate sub-elliptic equations in the Heisenberg group, and study the regularities of solutions. We establish horizontal Calderón-Zygmund type estimate in Be...In this article, we deal with weak solutions to non-degenerate sub-elliptic equations in the Heisenberg group, and study the regularities of solutions. We establish horizontal Calderón-Zygmund type estimate in Besov spaces with more general assumptions on coefficients for both homogeneous equations and non-homogeneous equations. This study of regularity estimates expands the Calderón-Zygmund theory in the Heisenberg group.展开更多
This study examines the impact of different CO<sub>2</sub> injection methods on coalbed methane recovery. Specifically, this study investigated the effectiveness of continuously injecting CO<sub>2<...This study examines the impact of different CO<sub>2</sub> injection methods on coalbed methane recovery. Specifically, this study investigated the effectiveness of continuously injecting CO<sub>2</sub> versus injecting CO<sub>2</sub> that had been soaked for two weeks. The objective was to ascertain which approach was more successful in enhancing CO<sub>2</sub> Enhanced coalbed Methane (CO<sub>2</sub>-ECBM). The experiment involved injecting 3 MPa of CH<sub>4</sub> into dry coal samples, allowing it to adsorb until reaching equilibrium, and then injecting 5 MPa of CO<sub>2</sub> to recover adsorbed CH<sub>4</sub>. The continuous method recovered CH<sub>4</sub> without detectable effluent concentration for 5 hours, but desorption efficiency was only 26% due to fast flow. On the other hand, the desorption efficiency of the cyclic method was only 12%, indicating trapped CH<sub>4</sub>. A comparison of desorption efficiency per unit of time shows the continuous method is more effective than the cyclic method. The results of this study demonstrate the continuous method is more effective for the desorption of CH<sub>4</sub>, and its efficiency can be improved by briefly soaking CO<sub>2</sub> on coal and then reinjecting it to maximize CH<sub>4</sub> recovery. It is advisable to limit the soaking time to prevent excessive swelling of the coal matrix, which can hinder seam flow and harm long-term gas production.展开更多
Introduction: Hepatitis B is an infectious disease that remains a real public health problem in Africa. Students represent a group at risk for this disease. The objective of this study was to estimate the hepatitis B ...Introduction: Hepatitis B is an infectious disease that remains a real public health problem in Africa. Students represent a group at risk for this disease. The objective of this study was to estimate the hepatitis B vaccination coverage rate among students in sub-Saharan Africa. Methods: A systematic search of databases (PubMed, AJOL) and a manual search of Google Scholar was conducted to retrieve all published studies reporting hepatitis B vaccination coverage among students in sub-Saharan Africa. The pooled coverage rate was estimated with a 95% confidence interval (CI) in a random-effects meta-analysis. Results: A total of 35 studies were included and included 20,520 students. The mean age was 22.1 ± 5.1 years with a predominance of female sex (sex ratio F/M = 1.05). The vaccination coverage rate was 28.8% [95% CI: 22.9% - 34.7%]. Disaggregation allowed to estimate coverage rates of 29.8% [95% CI: 22.9% - 36.7%], 23.4% [95% CI: 9.4% - 37.4%] and 17.0% [95% CI: 14.4% - 19.5%] respectively in West Africa, East Africa and Central Africa. Conclusion: Less than a third of students in sub-Saharan Africa are protected against hepatitis B. However, the majority of this target group is at risk of infection. It would be relevant to screen and, if necessary, vaccinate all new students.展开更多
The simulation by the Monte Carlo method executed by the software PyPENELOPE proved effective to specify the particle propagation characteristics by calculating the absorption fractions, backscattering and transmissio...The simulation by the Monte Carlo method executed by the software PyPENELOPE proved effective to specify the particle propagation characteristics by calculating the absorption fractions, backscattering and transmission of electrons and secondary photons under the incidence of 0.5 to 20 KeV range of primary electrons. More than 99.9% of the primary electrons were transmitted in the 125 nm thick MgO/TiO<sub>2</sub> material at 20 KeV. This occurred because several interactions took place in the transmitted primary irradiation such as characteristic, fluorescence, and bremsstrahlung produced when of the occupation of the KL3, KL2, KM3, and KM2 shell and sub-shell of titanium and magnesium which are the elements with a high atomic number in the material. The transmission particle characteristic of this material is therefore an indicator capable of improving the electrical performance and properties of the sensor.展开更多
This study focused on the development and characterization of TiO<sub>2</sub>-PES composite fibers with varying TiO<sub>2</sub> loading amounts using a phase inversion process. The resulting co...This study focused on the development and characterization of TiO<sub>2</sub>-PES composite fibers with varying TiO<sub>2</sub> loading amounts using a phase inversion process. The resulting composite fibers exhibited a sponge-like structure with embedded TiO<sub>2</sub> nanoparticles within a polymer matrix. Their photocatalytic performance for ammonia removal from aqueous solutions under UV-A light exposure was thoroughly investigated. The findings revealed that PeTi8 composite fibers displayed superior adsorption capacity compared to other samples. Moreover, the study explored the impact of pH, light intensity, and catalyst dosage on the photocatalytic degradation of ammonia. Adsorption equilibrium isotherms closely followed the Langmuir model, with the results indicating a correlation between qm values of 2.49 mg/g and the porous structure of the adsorbents. The research underscored the efficacy of TiO<sub>2</sub> composite fibers in the photocatalytic removal of aqueous under UV-A light. Notably, increasing the distance between the photocatalyst and the light source resulted in de-creased hydroxyl radical concentration, influencing photocatalytic efficiency. These findings contribute to our understanding of TiO<sub>2</sub> composite fibers as promising photocatalysts for ammonia removal in water treatment applications.展开更多
基金partially supported by National Key Research and Development Program of China(2019YFC1510902)National Natural Science Foundation of China(62073104)+1 种基金Natural Science Foundation of Heilongjiang Province(LH2022F024)China Postdoctoral Science Foundation(2022M710965)。
文摘This paper presents a subspace identification method for closed-loop systems with unknown deterministic disturbances.To deal with the unknown deterministic disturbances,two strategies are implemented to construct the row space that can be used to approximately represent the unknown deterministic disturbances using the trigonometric functions or Bernstein polynomials depending on whether the disturbance frequencies are known.For closed-loop identification,CCF-N4SID is extended to the case with unknown deterministic disturbances using the oblique projection.In addition,a proper Bernstein polynomial order can be determined using the Akaike information criterion(AIC)or the Bayesian information criterion(BIC).Numerical simulation results demonstrate the effectiveness of the proposed identification method for both periodic and aperiodic deterministic disturbances.
基金Project supported by the National Natural Science Foundation of China(Grant No.62061014)the Natural Science Foundation of Liaoning province of China(Grant No.2020-MS-274).
文摘Security during remote transmission has been an important concern for researchers in recent years.In this paper,a hierarchical encryption multi-image encryption scheme for people with different security levels is designed,and a multiimage encryption(MIE)algorithm with row and column confusion and closed-loop bi-directional diffusion is adopted in the paper.While ensuring secure communication of medical image information,people with different security levels have different levels of decryption keys,and differentiated visual effects can be obtained by using the strong sensitivity of chaotic keys.The highest security level can obtain decrypted images without watermarks,and at the same time,patient information and copyright attribution can be verified by obtaining watermark images.The experimental results show that the scheme is sufficiently secure as an MIE scheme with visualized differences and the encryption and decryption efficiency is significantly improved compared to other works.
文摘Background: Sub arachnoid block (SAB) performed by traditional landmark palpation technique can be inaccurate. This problem is exacerbated by altered patient anatomy due to obesity and age-related changes. A pre-procedural ultrasound scan of the lumbar spine has been shown to be of benefit in guiding lumbar epidural insertion in obstetric patients. Information on the use of real-time ultrasound (RUS) guided SAB, to date, been limited. This study compared RUS guided SAB to traditional landmark guided technique in patients undergoing spinal anesthesia for different surgical procedures. Methods: This was a prospective, single center, comparative observational study conducted in the department of anesthesiology at our center. 560 patients who underwent spinal anesthesia either by landmark based technique or real-time ultrasound-guided methods. The primary outcome was the first attempt success rate of dural puncture when employing the two methods. Results: Baseline characteristics were similar in the two study groups. The first attempt success rate of dural puncture in landmark guided group was 64.3% compared to 72.6% in the ultrasound guided group. This difference was not statistically significant. The procedure performance time was significantly shorter with landmark palpation compared to use of real-time ultrasound guided method. Conclusion: Use of RUS-guided technique does not significantly improve the first attempt success rate of SAB dural puncture during spinal anesthesia compared to the traditional landmark-guided technique.
文摘BACKGROUND In 2016,the Food and Drug Administration approved the first hybrid closed-loop(HCL)insulin delivery system for adults with type 1 diabetes(T1D).There is limited information on the impact of using HCL systems on patient-reported outcomes(PROs)in patients with T1D in real-world clinical practice.In this independent study,we evaluated glycemic parameters and PROs over one year of continuous use of Medtronic’s 670G HCL in real-world clinical practice.AIM To assess the effects of hybrid closed loop system on glycemic control and quality of life in adults with T1D.METHODS We evaluated 71 patients with T1D(mean age:45.5±12.1 years;59%females;body weight:83.8±18.7 kg,body mass index:28.7±5.6 kg/m2,A1C:7.6%±0.8%)who were treated with HCL at Joslin Clinic from 2017 to 2019.We measured A1C and percent of glucose time-in-range(%TIR)at baseline and 12 months.We measured percent time in auto mode(%TiAM)for the last two weeks preceding the final visit and assessed PROs through several validated quality-of-life surveys related to general health and diabetes management.RESULTS At 12 mo,A1C decreased by 0.3%±0.1%(P=0.001)and%TIR increased by 8.1%±2.5%(P=0.002).The average%TiAM was only 64.3%±32.8%and was not associated with A1C,%TIR or PROs.PROs,provided at baseline and at the end of the study,showed that the physical functioning submodule of 36Item Short-Form Health Survey increased significantly by 22.9%(P<0.001).Hypoglycemia fear survey/worry scale decreased significantly by 24.9%(P<0.000);Problem Areas In Diabetes reduced significantly by-17.2%(P=0.002).The emotional burden submodules of dietary diversity score reduced significantly by-44.7%(P=0.001).Furthermore,analysis of Clarke questionnaire showed no increase in awareness of hypoglycemic episodes.WHO-5 showed no improvements in subject’s wellbeing among participants after starting the 670G HCL system.Finally,analysis of Pittsburgh Sleep Quality Index showed no difference in sleep quality,sleep latency,or duration of sleep from baseline to 12 mo.CONCLUSION The use of HCL in real-world clinical practice for one year was associated with significant improvements in A1C,%TIR,physical functioning,hypoglycemia fear,emotional distress,and emotional burden related to diabetes management.However,these changes were not associated with time in auto mode.
文摘In this paper, we modify the Bregman APG<sub>s</sub> (BAPG<sub>s</sub>) method proposed in (Wang, L, et al.) for solving the support vector machine problem with truncated loss (HTPSVM) given in (Zhu, W, et al.), we also add an adaptive parameter selection technique based on (Ren, K, et al.). In each iteration, we use the linear approximation method to get the explicit solution of the subproblem and set a function to apply the Bregman distance. Finally, numerical experiments are performed to verify the efficiency of BAPG<sub>s</sub>.
文摘Angiotensin II (Ang II) is the main mediator of the Renin-Angiotensin-System acting on AT<sub>1</sub> and other AT receptors. It is regarded as a pleiotropic agent that induces many actions, including functioning as a growth factor, and as a contractile hormone, among others. The aim of this work was to examine the impact of Ang II on the expression and function of α<sub>1</sub>-adrenergic receptors (α<sub>1</sub>-ARs) in cultured rat aorta, and aorta-derived smooth muscle cells. Isolated Wistar rat aorta was incubated for 24 h in DMEM at 37˚C, then subjected to isometric tension and to the action of added norepinephrine, in concentration-response curves. Ang II was added (1 × 10<sup>−5</sup> M), and in some experiments, 5-Methylurapidil (α<sub>1A</sub>-AR antagonist), AH11110A (α<sub>1B</sub>-AR antagonist), or BMY-7378 (α<sub>1D</sub>-AR antagonist), were used to identify the α<sub>1</sub>-AR involved in the response. Desensitization of the contractile response to norepinephrine was observed due to incubation time, and by the Ang II action. α<sub>1D</sub>-AR was protected from desensitization by BMY-7378;while RS-100329 and prazosin partially mitigated desensitization. In another set of experiments, isolated aorta-derived smooth muscle cells were exposed to Ang II and α<sub>1</sub>-ARs proteins were evaluated. α<sub>1D</sub>-AR increased at 30 and 60 min post Ang II exposure, the α<sub>1A</sub>-AR diminished from 1 to 4 h, while α<sub>1B</sub>-AR remained unchanged over 24 h of Ang II exposure. Ang II induced an increase of α<sub>1D</sub>-AR at short times, and BMY-7378 protected α<sub>1D</sub>-AR from desensitization.
文摘The lethal dose LD<sub>50</sub> represents the most important experimental value for acute toxicity. The simple logarithmic calculation of -log<sub>10</sub> LD<sub>50</sub> = value leads to the possible poison power pLD. As with the pH or pK value, respectively, for acid or the scale of earthquake intensities the logarithm helps making large differences of orders of magnitude easier to understand since they are more comparable. The higher the pLD value, the higher is the power of poison. An increase of the pLD value by 1 stands for a tenfold increase in toxicity. The lethal acute dose for water, one of the most important and at the same time non-toxic substances of all, is about one tenth of the body weight. This leads to a possible pLD value for water of 1, an ideal starting value for a logarithmic poison scale.
文摘Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuring the quantitative assessment of emissions for informed decisions on environmental treatments. This paper describes a method for the calibration of CO/CO<sub>2</sub> monitors used for periodic inspections of vehicles in cites. The calibration was performed in the selected ranges: 900 - 12,000 µmol/mol for CO and 2000 - 20,000 µmol/mol for CO<sub>2</sub>. The traceability of the measurement results to the SI units was ensured by using certified reference materials from CO/N<sub>2</sub> and CO<sub>2</sub>/N<sub>2</sub> primary gas mixtures. The method performance was evaluated by assessing its linearity, accuracy, precision, bias, and uncertainty of the calibration results. The calibration data exhibited a strong linear trend with R² values close to 1, indicating an excellent fit between the measured values and the calibration lines. Precision, expressed as relative standard deviation (%RSD), ranged from 0.48 to 4.56% for CO and from 0.97 to 3.53% for CO<sub>2</sub>, staying well below the 5% threshold for reporting results at a 95% confidence level. Accuracy measured as percent recovery, was consistently high (≥ 99.1%) for CO and ranged from 84.90% to 101.54% across the calibration range for CO<sub>2</sub>. In addition, the method exhibited minimal bias for both CO and CO<sub>2</sub> calibrations and thus provided a reliable and accurate approach for calibrating CO/CO<sub>2</sub> monitors used in vehicle inspections. Thus, it ensures the effectiveness of exhaust emission control for better environment.
文摘We report the performances of a chalcopyrite Cu(In, Ga)Se<sub>2 </sub>CIGS-based thin-film solar cell with a newly employed high conductive n-Si layer. The data analysis was performed with the help of the 1D-Solar Cell Capacitance Simulator (1D-SCAPS) software program. The new device structure is based on the CIGS layer as the absorber layer, n-Si as the high conductive layer, i-In<sub>2</sub>S<sub>3</sub>, and i-ZnO as the buffer and window layers, respectively. The optimum CIGS bandgap was determined first and used to simulate and analyze the cell performance throughout the experiment. This analysis revealed that the absorber layer’s optimum bandgap value has to be 1.4 eV to achieve maximum efficiency of 22.57%. Subsequently, output solar cell parameters were analyzed as a function of CIGS layer thickness, defect density, and the operating temperature with an optimized n-Si layer. The newly modeled device has a p-CIGS/n-Si/In<sub>2</sub>S<sub>3</sub>/Al-ZnO structure. The main objective was to improve the overall cell performance while optimizing the thickness of absorber layers, defect density, bandgap, and operating temperature with the newly employed optimized n-Si layer. The increase of absorber layer thickness from 0.2 - 2 µm showed an upward trend in the cell’s performance, while the increase of defect density and operating temperature showed a downward trend in solar cell performance. This study illustrates that the proposed cell structure shows higher cell performances and can be fabricated on the lab-scale and industrial levels.
文摘Aim: This study aimed to investigate the protective effects of flavonoids from the stem and leaves of Scutellaria baicalensis Georgi (SSFs) against Aβ<sub>1-42</sub>-induced oligodendrocytes (OL) damage. Methods: Immunofluorescence was used for the detection of myelin-associated glycoprotein (MAG), a characteristic protein of rat oligodendrocytes (OLN-93 cells). To evaluate the potential protective effects of SSFs on OLN-93 cells injured by Aβ<sub>1-42</sub>, an injury model was established by subjecting OLN-93 cells to Aβ<sub>1-42</sub> exposed. Cell morphology was examined using an inverted microscope, while cell viability was assessed using the colorimetric method of 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT). Additionally, lactate dehydrogenase (LDH) was measured using the pyruvic acid reduction assay. The Ginkgo biloba leaf extract (GBE) injection was used as a positive control. Results: A total of >95% of the MAG immunofluorescence-positive cells were identified as oligodendrocytes. Gradually increasing concentrations of SSFs impaired the cells, and the maximum nondetrimental dose for OLN-93 cells was 75 mg/L. This study assessed the effects of SSFs on OLN-93 cells damaged by Aβ<sub>1-42</sub>. The results indicated that SSFs significantly improved OLN-93 cell morphological abnormal changes, increased the OLN-93 cell survival rate, and reduced LDH release. Conclusion: SSFs can alleviate Aβ<sub>1-42</sub>-induced damage of OL.
文摘Silane coupling agent KH560 was used to modify the surface of nano-α-Al<sub>2</sub>O<sub>3</sub> in ethanol-aqueous solution with different proportions. The particle size of nano-α-Al<sub>2</sub>O<sub>3</sub> was determined by nano-particle size analyzer, and the effects of nano-α-Al<sub>2</sub>O<sub>3</sub> content, ethanol-aqueous solution ratio and KH560 dosage on the dispersion and particle size of nano-α-Al<sub>2</sub>O<sub>3</sub> were investigated. The material structure before and after modification was determined by Fourier transform infrared spectroscopy (FTIR). Aqueous polyurethane resin and inorganic components are combined with modified nano-α-Al<sub>2</sub>O<sub>3</sub> dispersion to form chromium-free passivation solution. The solution is coated on the galvanized sheet, the adhesion and surface hardness are tested, the bonding strength of the coating and the surface hardness of the substrate are discussed. The corrosion resistance and surface morphology of the matrix were investigated by electrochemical test, neutral salt spray test and scanning electron microscope test. The chromium-free passivation film formed after the modification of nano-α-Al<sub>2</sub>O<sub>3</sub> increases the surface hardness of galvanized sheet by about 85%. The corrosion resistance of the film is better than that of a single polyurethane film. The results show that the surface hardness and corrosion resistance of polyurethane resin composite passivation film are significantly improved by the introduction of nano-α-Al<sub>2</sub>O<sub>3</sub>.
文摘This research investigates the comparative efficacy of generating zero divisor graphs (ZDGs) of the ring of integers ℤ<sub>n</sub> modulo n using MAPLE algorithm. Zero divisor graphs, pivotal in the study of ring theory, depict relationships between elements of a ring that multiply to zero. The paper explores the development and implementation of algorithms in MAPLE for constructing these ZDGs. The comparative study aims to discern the strengths, limitations, and computational efficiency of different MAPLE algorithms for creating zero divisor graphs offering insights for mathematicians, researchers, and computational enthusiasts involved in ring theory and mathematical computations.
文摘This study was aimed to investigate the effects of hydrothermal aging, propene and SO<sub>2</sub> poisoning on the ammonia-selective catalytic reduction (NH<sub>3</sub>-SCR) performance of both Cu-SAPO-34 and Cu-ZSM-5. The catalytic activities of fresh, aged and poisoned samples were tested in ammonia-selective catalytic reduction (NH<sub>3</sub>-SCR) of NO<sub>x</sub> conditions. The XRD, TG and N<sub>2</sub>-desorption results showed that the structures of the Cu-SAPO-34 and Cu-ZSM-5 remained intact after 750˚C hydrothermally aged, SO<sub>2</sub> and propene poisoned. After hydrothermal aging at 750˚C for 12 h, the NO reduction performance of Cu-ZSM-5 was significantly reduced at lower temperatures, while that of Cu-SAPO-34 was less affected. Moreover, Cu-SAPO-34 catalyst showed high NO conversion with SO<sub>2</sub> or propene compared to Cu-ZSM-5. However, Cu-ZSM-5 showed a larger drop in catalytic activity with SO<sub>2</sub> or propene compared to Cu-SAPO-34 catalyst. The H<sub>2</sub>-TPR results showed that Cu<sup>2 </sup> ions could be reduced to Cu<sup> </sup> and Cu<sup>0</sup> for Cu-ZSM-5, while no significant transformation of copper species was observed for Cu-SAPO-34. Meanwhile, the UV-vis DRS results showed that CuO species were formed in Cu-ZSM-5, while little changes were observed for the Cu-SAPO-34. Cu-SAPO-34 showed high sulfur and hydrocarbon poison resistance compared to Cu-ZSM-5. In summary, Cu-SAPO-34 with small-pore zeolite showed higher hydrothermal stability and better hydrocarbon and sulfur poison resistant than Cu-ZSM-5 with medium-pore.
文摘Corn rod-like WO<sub>3</sub> nanomaterials were successfully synthesized by a simple hydrothermal method. The morphology, structure and optical absorption properties of the prepared samples were characterized by SEM, XRD, FTIR and UV-Vis-DRS. The WO<sub>3</sub> materials were corn rod-like morphology with about 800 nm for length and 150 nm for diameter, especially there were plenty of corn particles (about 20 nm) on the surface of corn rods. The X-ray diffraction peaks of the products corresponded with WO<sub>3</sub> standard card, and the characteristic peak of W-O bond was found in the infrared spectrum. The absorption band edge of the products was about 480 nm, indicating their potential visible-light-induced photocatalytic activity. In situ FTIR technology research showed that the prepared WO<sub>3</sub> nanomaterials had visible photocatalytic activity to gas-phase toluene. After a photocatalytic reaction for 8 hours toluene was effectively degraded, and carboxylic acid and aldehyde could be regarded as the intermediate products, and CO<sub>2</sub> was produced as the final product during the reaction process.
文摘In this article, we deal with weak solutions to non-degenerate sub-elliptic equations in the Heisenberg group, and study the regularities of solutions. We establish horizontal Calderón-Zygmund type estimate in Besov spaces with more general assumptions on coefficients for both homogeneous equations and non-homogeneous equations. This study of regularity estimates expands the Calderón-Zygmund theory in the Heisenberg group.
文摘This study examines the impact of different CO<sub>2</sub> injection methods on coalbed methane recovery. Specifically, this study investigated the effectiveness of continuously injecting CO<sub>2</sub> versus injecting CO<sub>2</sub> that had been soaked for two weeks. The objective was to ascertain which approach was more successful in enhancing CO<sub>2</sub> Enhanced coalbed Methane (CO<sub>2</sub>-ECBM). The experiment involved injecting 3 MPa of CH<sub>4</sub> into dry coal samples, allowing it to adsorb until reaching equilibrium, and then injecting 5 MPa of CO<sub>2</sub> to recover adsorbed CH<sub>4</sub>. The continuous method recovered CH<sub>4</sub> without detectable effluent concentration for 5 hours, but desorption efficiency was only 26% due to fast flow. On the other hand, the desorption efficiency of the cyclic method was only 12%, indicating trapped CH<sub>4</sub>. A comparison of desorption efficiency per unit of time shows the continuous method is more effective than the cyclic method. The results of this study demonstrate the continuous method is more effective for the desorption of CH<sub>4</sub>, and its efficiency can be improved by briefly soaking CO<sub>2</sub> on coal and then reinjecting it to maximize CH<sub>4</sub> recovery. It is advisable to limit the soaking time to prevent excessive swelling of the coal matrix, which can hinder seam flow and harm long-term gas production.
文摘Introduction: Hepatitis B is an infectious disease that remains a real public health problem in Africa. Students represent a group at risk for this disease. The objective of this study was to estimate the hepatitis B vaccination coverage rate among students in sub-Saharan Africa. Methods: A systematic search of databases (PubMed, AJOL) and a manual search of Google Scholar was conducted to retrieve all published studies reporting hepatitis B vaccination coverage among students in sub-Saharan Africa. The pooled coverage rate was estimated with a 95% confidence interval (CI) in a random-effects meta-analysis. Results: A total of 35 studies were included and included 20,520 students. The mean age was 22.1 ± 5.1 years with a predominance of female sex (sex ratio F/M = 1.05). The vaccination coverage rate was 28.8% [95% CI: 22.9% - 34.7%]. Disaggregation allowed to estimate coverage rates of 29.8% [95% CI: 22.9% - 36.7%], 23.4% [95% CI: 9.4% - 37.4%] and 17.0% [95% CI: 14.4% - 19.5%] respectively in West Africa, East Africa and Central Africa. Conclusion: Less than a third of students in sub-Saharan Africa are protected against hepatitis B. However, the majority of this target group is at risk of infection. It would be relevant to screen and, if necessary, vaccinate all new students.
文摘The simulation by the Monte Carlo method executed by the software PyPENELOPE proved effective to specify the particle propagation characteristics by calculating the absorption fractions, backscattering and transmission of electrons and secondary photons under the incidence of 0.5 to 20 KeV range of primary electrons. More than 99.9% of the primary electrons were transmitted in the 125 nm thick MgO/TiO<sub>2</sub> material at 20 KeV. This occurred because several interactions took place in the transmitted primary irradiation such as characteristic, fluorescence, and bremsstrahlung produced when of the occupation of the KL3, KL2, KM3, and KM2 shell and sub-shell of titanium and magnesium which are the elements with a high atomic number in the material. The transmission particle characteristic of this material is therefore an indicator capable of improving the electrical performance and properties of the sensor.
文摘This study focused on the development and characterization of TiO<sub>2</sub>-PES composite fibers with varying TiO<sub>2</sub> loading amounts using a phase inversion process. The resulting composite fibers exhibited a sponge-like structure with embedded TiO<sub>2</sub> nanoparticles within a polymer matrix. Their photocatalytic performance for ammonia removal from aqueous solutions under UV-A light exposure was thoroughly investigated. The findings revealed that PeTi8 composite fibers displayed superior adsorption capacity compared to other samples. Moreover, the study explored the impact of pH, light intensity, and catalyst dosage on the photocatalytic degradation of ammonia. Adsorption equilibrium isotherms closely followed the Langmuir model, with the results indicating a correlation between qm values of 2.49 mg/g and the porous structure of the adsorbents. The research underscored the efficacy of TiO<sub>2</sub> composite fibers in the photocatalytic removal of aqueous under UV-A light. Notably, increasing the distance between the photocatalyst and the light source resulted in de-creased hydroxyl radical concentration, influencing photocatalytic efficiency. These findings contribute to our understanding of TiO<sub>2</sub> composite fibers as promising photocatalysts for ammonia removal in water treatment applications.