An extended interaction oscillator (EIO) generating 120 GHz wave in sub-terahertz waves is studied by using the three-dimensional electromagnetic simulation software CST and PIC codes. A rectangular reentrant couple...An extended interaction oscillator (EIO) generating 120 GHz wave in sub-terahertz waves is studied by using the three-dimensional electromagnetic simulation software CST and PIC codes. A rectangular reentrant coupled-cavity is proposed as the slow-wave structure of EIO. By CST, the circuit parameters including frequency-phase dispersion, interaction impedance and characteristic impedance are simulated and calculated. The operation mode of EIO is chosen very close to the point where βL = 2π with corresponding frequency 120 GHz, the beam voltage 12 kV and the dimensions of the cavity with the period 0.5mm, the height 3mm and the width 1.4mm. Simulation results of beam-wave interaction by PIC show that the exciting frequency is 120.85 GHz and output peak power 465 W with 12-period coupled-cavity with the perveance 0.17 μP. Simulation results indicate that the EIO has very wide range of the operation voltage.展开更多
Nowadays with the improvement in the degree of emphasis on new energy, the wind power system has developed more and more rapidly over the world. Usually the wind plants are located in the remote areas which are far fr...Nowadays with the improvement in the degree of emphasis on new energy, the wind power system has developed more and more rapidly over the world. Usually the wind plants are located in the remote areas which are far from the load centers. Generally series compensated AC transmission and high voltage DC transmission are made use of to improve the transmission capacity as two main effective ways which can solve the problem of large scale wind power transmission. The paper describes the three kinds of impact varieties and impact mechanisms in the sub-synchronous oscillation phenomena of wind power system based on doubly fed induction generator (DFIG) wind generators. At last, we point out the important problem that should be stressed in the wind power system.展开更多
It is difficult to obtain analytic approximations of nonlinear problems such as parameter excited system with strong nonlinearity. An analytic approach based on the homotopy analysis method( HAM) is proposed to study ...It is difficult to obtain analytic approximations of nonlinear problems such as parameter excited system with strong nonlinearity. An analytic approach based on the homotopy analysis method( HAM) is proposed to study the sub-harmonic resonances of highly nonlinear parameter excited oscillating systems with absolute value terms. The non-smoothness of absolute value terms is handled by means of an iteration approach with Fourier expansion. Two typical examples are employed to illustrate the validity and flexibility of this approach. The square residuals of the homotopy-approximations of the two examples decrease to 10-6and 10-5,respectively. Thus,the HAM combining with other methods gives hope to solve complex singular oscillating systems analytically.展开更多
In recent years,sub/super-synchronous oscillations occur frequently in large-scale wind power bases throughout China.Since the oscillation frequencies are close to the fundamental frequency,the current components can ...In recent years,sub/super-synchronous oscillations occur frequently in large-scale wind power bases throughout China.Since the oscillation frequencies are close to the fundamental frequency,the current components can spread over a large area,and may destroy the shafting of rotating devices in the power grid.Improving the control strategy and parameters of wind turbines can prevent this problem to some extent,however,due to complex operational conditions and continuous development of wind power,the off-line improvement measures on wind turbines cannot eliminate the potential oscillation risks.This paper proposes an oscillation risk screening and stability assessment method,and develops a coordination control method for large-scale wind farm systems to prevent sub/supersynchronous oscillations.The Nyquist criterion and the modal analysis method are combined to generate quantitative factors for the stability assessment and the control strategy design.The coordination control method consists of minute-level power coordinated allocation and second-level fast power control to prevent and eliminate the oscillations.A detailed simulation model of a multiple wind farms system originated from an actual wind power base in China is presented to verify the effectiveness of the proposed method.展开更多
基金supported by the National Natural Science Foundation of China (Grant No 10676110)the National Basic Research Program of China (Grant No 2007CB310401)
文摘An extended interaction oscillator (EIO) generating 120 GHz wave in sub-terahertz waves is studied by using the three-dimensional electromagnetic simulation software CST and PIC codes. A rectangular reentrant coupled-cavity is proposed as the slow-wave structure of EIO. By CST, the circuit parameters including frequency-phase dispersion, interaction impedance and characteristic impedance are simulated and calculated. The operation mode of EIO is chosen very close to the point where βL = 2π with corresponding frequency 120 GHz, the beam voltage 12 kV and the dimensions of the cavity with the period 0.5mm, the height 3mm and the width 1.4mm. Simulation results of beam-wave interaction by PIC show that the exciting frequency is 120.85 GHz and output peak power 465 W with 12-period coupled-cavity with the perveance 0.17 μP. Simulation results indicate that the EIO has very wide range of the operation voltage.
文摘Nowadays with the improvement in the degree of emphasis on new energy, the wind power system has developed more and more rapidly over the world. Usually the wind plants are located in the remote areas which are far from the load centers. Generally series compensated AC transmission and high voltage DC transmission are made use of to improve the transmission capacity as two main effective ways which can solve the problem of large scale wind power transmission. The paper describes the three kinds of impact varieties and impact mechanisms in the sub-synchronous oscillation phenomena of wind power system based on doubly fed induction generator (DFIG) wind generators. At last, we point out the important problem that should be stressed in the wind power system.
基金Sponsored by the National Natural Science Foundation of China(Grant No.11272209)the State Key Laboratory of Ocean Engineering(Grant No.GKZD010059)
文摘It is difficult to obtain analytic approximations of nonlinear problems such as parameter excited system with strong nonlinearity. An analytic approach based on the homotopy analysis method( HAM) is proposed to study the sub-harmonic resonances of highly nonlinear parameter excited oscillating systems with absolute value terms. The non-smoothness of absolute value terms is handled by means of an iteration approach with Fourier expansion. Two typical examples are employed to illustrate the validity and flexibility of this approach. The square residuals of the homotopy-approximations of the two examples decrease to 10-6and 10-5,respectively. Thus,the HAM combining with other methods gives hope to solve complex singular oscillating systems analytically.
文摘In recent years,sub/super-synchronous oscillations occur frequently in large-scale wind power bases throughout China.Since the oscillation frequencies are close to the fundamental frequency,the current components can spread over a large area,and may destroy the shafting of rotating devices in the power grid.Improving the control strategy and parameters of wind turbines can prevent this problem to some extent,however,due to complex operational conditions and continuous development of wind power,the off-line improvement measures on wind turbines cannot eliminate the potential oscillation risks.This paper proposes an oscillation risk screening and stability assessment method,and develops a coordination control method for large-scale wind farm systems to prevent sub/supersynchronous oscillations.The Nyquist criterion and the modal analysis method are combined to generate quantitative factors for the stability assessment and the control strategy design.The coordination control method consists of minute-level power coordinated allocation and second-level fast power control to prevent and eliminate the oscillations.A detailed simulation model of a multiple wind farms system originated from an actual wind power base in China is presented to verify the effectiveness of the proposed method.