We designed an improved direct-current capacitor voltage balancing control model predictive control(MPC)for single-phase cascaded H-bridge multilevel photovoltaic(PV)inverters.Compared with conventional voltage balanc...We designed an improved direct-current capacitor voltage balancing control model predictive control(MPC)for single-phase cascaded H-bridge multilevel photovoltaic(PV)inverters.Compared with conventional voltage balanc-ing control methods,the method proposed could make the PV strings of each submodule operate at their maximum power point by independent capacitor voltage control.Besides,the predicted and reference value of the grid-connected current was obtained according to the maximum power output of the maximum power point tracking.A cost function was con-structed to achieve the high-precision grid-connected control of the CHB inverter.Finally,the effectiveness of the proposed control method was verified through a semi-physical simulation platform with three submodules.展开更多
Modular multilevel converter (MMC) based fault ride through (FRT) control is a promising solution to deal with the pole-to-ground (PTG) fault in high voltage direct current (HVDC) system. However, when MMC switches to...Modular multilevel converter (MMC) based fault ride through (FRT) control is a promising solution to deal with the pole-to-ground (PTG) fault in high voltage direct current (HVDC) system. However, when MMC switches to the FRT control, capacitor voltage imbalance between upper and lower arms will occur, resulting in the deterioration of FRT performance. This letter provides a comprehensive analysis for the imbalance issue from the perspective of fundamental frequency circulating current (FFCC). It is found the imbalance during FRT stage will not expand continuously, but converge to a certain value gradually. The specific imbalance degree is closely associated with the amplitude of FFCC. In order to solve the imbalance issue, an open-loop balancing control is proposed. By introducing a fundamental frequency feedforward item to the inherent circulating current control, the proposed method can not only balance the capacitor voltages, but also minimize the amplitude of FFCC, and consequently the power loss of MMC during FRT process can be reduced. Finally, simulation results of PSCAD/ EMTDC verify the validity of theoretical analysis.展开更多
部分接入电池储能系统的模块化多电平换流器(MMC with partly integrated BESS,MMCPBESS)可以在接入储能的同时节约建造成本,但其控制更加复杂。针对下桥臂接入储能电池的MMC-PBESS拓扑,建立数学模型及等效电路。在此基础上给出电容电...部分接入电池储能系统的模块化多电平换流器(MMC with partly integrated BESS,MMCPBESS)可以在接入储能的同时节约建造成本,但其控制更加复杂。针对下桥臂接入储能电池的MMC-PBESS拓扑,建立数学模型及等效电路。在此基础上给出电容电压均衡策略,提出了上/下桥臂分控的控制策略,并分析了其运行边界。在MATLAB/Simulink平台搭建仿真模型,仿真了不同交直流功率比例的运行工况,所提控制策略可以在维持电容电压平衡的同时实现对电池充电的功能。该策略无需额外的环流计算,上下桥臂控制解耦,简单灵活。展开更多
针对电力电子变压器的非线性特性,传统PI控制的单相电力电子变压器整流级具有对参数变化敏感,响应速度慢,抗扰性能差的特点。提出了一种基于线性自抗扰控制(line active disturbance rejection control,LADRC)的电压环控制策略,该控制...针对电力电子变压器的非线性特性,传统PI控制的单相电力电子变压器整流级具有对参数变化敏感,响应速度慢,抗扰性能差的特点。提出了一种基于线性自抗扰控制(line active disturbance rejection control,LADRC)的电压环控制策略,该控制策略具有响应速度快、超调量小、鲁棒性强的特点。在仿真软件MATLAB/Simulink中通过搭建三级联H桥整流器模型进行仿真,并与传统PI控制器相比较,仿真结果表明所采用控制策略的优越性、有效性。展开更多
Open-end winding motors are used extensively in ship electric propulsion systems,in which medium-voltage high-power inverters are a critical component.To increase the system voltage and power density,a dual five-level...Open-end winding motors are used extensively in ship electric propulsion systems,in which medium-voltage high-power inverters are a critical component.To increase the system voltage and power density,a dual five-level active neutral-point clamped(ANPC)inverter is proposed herein to drive medium-voltage open-end winding motors for ship electric propulsion.Each phase of this inverter comprises two five-level ANPC bridges and all the phases are powered by a common direct-current link.A hybrid modulation method is proposed to control this inverter.The series-connected switches in all the five-level ANPC bridges are operated at the fundamental frequency,and the other switches are controlled with a phase-shifted pulse-width modulation(PWM),which can achieve a natural balance between the neutral-point voltage and flying capacitor voltages in a carrier period.A closed-loop capacitor voltage balancing method based on adjusting the duty ratios of the PWM signals is proposed.The neutral-point voltage and flying capacitor voltages can be controlled independently and balanced without affecting the output phase voltage.Simulation and experimental results are presented to demonstrate the validity of this method.展开更多
基金Research on Control Methods and Fault Tolerance of Multilevel Electronic Transformers for PV Access(Project number:042300034204)Research on Open-Circuit Fault Diagnosis and Seamless Fault-Tolerant Control of Multiple Devices in Modular Multilevel Digital Power Amplifiers(Project number:202203021212210)Research on Key Technologies and Demonstrations of Low-Voltage DC Power Electronic Converters Based on SiC Devices Access(Project number:202102060301012)。
文摘We designed an improved direct-current capacitor voltage balancing control model predictive control(MPC)for single-phase cascaded H-bridge multilevel photovoltaic(PV)inverters.Compared with conventional voltage balanc-ing control methods,the method proposed could make the PV strings of each submodule operate at their maximum power point by independent capacitor voltage control.Besides,the predicted and reference value of the grid-connected current was obtained according to the maximum power output of the maximum power point tracking.A cost function was con-structed to achieve the high-precision grid-connected control of the CHB inverter.Finally,the effectiveness of the proposed control method was verified through a semi-physical simulation platform with three submodules.
基金supported by Zhejiang Province Natural Science Foundation of China under Grant LQ22E070002Shandong Province Natural Science Foundation of China under Grant ZR2020QE215.
文摘Modular multilevel converter (MMC) based fault ride through (FRT) control is a promising solution to deal with the pole-to-ground (PTG) fault in high voltage direct current (HVDC) system. However, when MMC switches to the FRT control, capacitor voltage imbalance between upper and lower arms will occur, resulting in the deterioration of FRT performance. This letter provides a comprehensive analysis for the imbalance issue from the perspective of fundamental frequency circulating current (FFCC). It is found the imbalance during FRT stage will not expand continuously, but converge to a certain value gradually. The specific imbalance degree is closely associated with the amplitude of FFCC. In order to solve the imbalance issue, an open-loop balancing control is proposed. By introducing a fundamental frequency feedforward item to the inherent circulating current control, the proposed method can not only balance the capacitor voltages, but also minimize the amplitude of FFCC, and consequently the power loss of MMC during FRT process can be reduced. Finally, simulation results of PSCAD/ EMTDC verify the validity of theoretical analysis.
文摘部分接入电池储能系统的模块化多电平换流器(MMC with partly integrated BESS,MMCPBESS)可以在接入储能的同时节约建造成本,但其控制更加复杂。针对下桥臂接入储能电池的MMC-PBESS拓扑,建立数学模型及等效电路。在此基础上给出电容电压均衡策略,提出了上/下桥臂分控的控制策略,并分析了其运行边界。在MATLAB/Simulink平台搭建仿真模型,仿真了不同交直流功率比例的运行工况,所提控制策略可以在维持电容电压平衡的同时实现对电池充电的功能。该策略无需额外的环流计算,上下桥臂控制解耦,简单灵活。
文摘针对电力电子变压器的非线性特性,传统PI控制的单相电力电子变压器整流级具有对参数变化敏感,响应速度慢,抗扰性能差的特点。提出了一种基于线性自抗扰控制(line active disturbance rejection control,LADRC)的电压环控制策略,该控制策略具有响应速度快、超调量小、鲁棒性强的特点。在仿真软件MATLAB/Simulink中通过搭建三级联H桥整流器模型进行仿真,并与传统PI控制器相比较,仿真结果表明所采用控制策略的优越性、有效性。
文摘Open-end winding motors are used extensively in ship electric propulsion systems,in which medium-voltage high-power inverters are a critical component.To increase the system voltage and power density,a dual five-level active neutral-point clamped(ANPC)inverter is proposed herein to drive medium-voltage open-end winding motors for ship electric propulsion.Each phase of this inverter comprises two five-level ANPC bridges and all the phases are powered by a common direct-current link.A hybrid modulation method is proposed to control this inverter.The series-connected switches in all the five-level ANPC bridges are operated at the fundamental frequency,and the other switches are controlled with a phase-shifted pulse-width modulation(PWM),which can achieve a natural balance between the neutral-point voltage and flying capacitor voltages in a carrier period.A closed-loop capacitor voltage balancing method based on adjusting the duty ratios of the PWM signals is proposed.The neutral-point voltage and flying capacitor voltages can be controlled independently and balanced without affecting the output phase voltage.Simulation and experimental results are presented to demonstrate the validity of this method.