期刊文献+
共找到133篇文章
< 1 2 7 >
每页显示 20 50 100
Bacterial diversity in activated sludge from a consecutively aerated submerged membrane bioreactor treating domestic wastewater 被引量:5
1
作者 DU, Cheng WU, Zhenbin +4 位作者 XIAO, Enrong ZHOU, Qiaohong CHENG, Shuiping LIANG, Wei HE, Feng 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2008年第10期1210-1217,共8页
The bacterial diversity of activated sludge from submerged membrane bioreactor (SMBR) was investigated. A 16S rDNA clone library was generated, and 150 clones were screened using restriction fragment length polymorphi... The bacterial diversity of activated sludge from submerged membrane bioreactor (SMBR) was investigated. A 16S rDNA clone library was generated, and 150 clones were screened using restriction fragment length polymorphism (RFLP). Of the screened clones, almost full-length 16S rDNA sequences of 64 clones were sequenced. Phylogenetic tree was constructed with a database containing clone sequences from this study and bacterial rDNA sequences from NCBI for identification purposes. The 90.6% of the clones were a?l... 展开更多
关键词 bacterial diversity restriction fragment length polymorphism (RFLP) submerged membrane bioreactor (smbr 16S rDNA clone library
下载PDF
Zeolite powder addition to improve the performance of submerged gravitation-filtration membrane bioreactor 被引量:8
2
作者 HE Sheng-bing XUE Gang KONG Hai-nan 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2006年第2期242-247,共6页
In this study, the effect of zeolite powder addition on submerged membrane bioreactor (SMBR) on membrane permeability, and the removals for COD, NH3-N, TN were investigated. Through the parallel operation of control... In this study, the effect of zeolite powder addition on submerged membrane bioreactor (SMBR) on membrane permeability, and the removals for COD, NH3-N, TN were investigated. Through the parallel operation of control and test systems, it was found that the zeolite powder addition could alleviate the ultra-filtration membrane fouling and enhance the membrane permeability. On the basis of experimental investigations, a concept of "protection coating layer" was proposed to illustrate the phenomenon of UF membrane fouling. In addition, the removal for COD in test system was more stable, a little higher compared to the control system. Due to the combination of nitrification and ion exchange, a more excellent removal for NH3-N in test system was obtained regardless of influent NH3-N loading rate. It was also found that a mean 25% higher TN removal took place in the test system, and ion exchange and simultaneous nitrification and de-nitrification were analyzed to be main factors. During the stable operation period, the SOURs of test zeolite powder added sludge and control activated sludge were measured to be 75 mgO2/(gMLVSS, h) and 24 mgO2/(gMLVSS, h) respectively, it meant that the zeolite powder addition could enhance the microorganism activity significantly. 展开更多
关键词 submerged gravitation-filtration membrane bioreactor PERFORMANCE zeolite powder membrane fouling microorganism activity
下载PDF
Enhancement of the flux for polypropylene hollow fiber membrane in a submerged membrane-bioreactor by surface modification 被引量:1
3
作者 YU Hai-yin LEI Hao XU Zhi-kang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2006年第6期1050-1055,共6页
To improve its limiting flux and antifouling characteristics in a submerged membrane-bioreactor (SMBR) for wastewater treatment, polypropylene hollow fiber microporous membrane (PPHFMM) was surface-modified by the... To improve its limiting flux and antifouling characteristics in a submerged membrane-bioreactor (SMBR) for wastewater treatment, polypropylene hollow fiber microporous membrane (PPHFMM) was surface-modified by the plasma-induced immobilization of poly (N-vinyl-2-pyrrolidone) (PVP) and the plasma treatment with different gases respectively. Attenuated total reflection-Fourier transform infrared spectroscopy (FT-IR/ATR), X-ray photoelectron spectroscopy (XPS) and field emission scanning electron microscope (FE-SEM) were used to characterize the structural and morphological changes on the membrane surface. Water contact angle was measured by the sessile drop method. It was found that the water contact angle was 128.8, 72.3, 62.7, 74.4, 79.1, 86.3, and 71.3° for the nascent, PVP-immobilized, air, 02, Ar, CO2 and H2O plasma treated PPHFMM, respectively. The SMBR was operated at fixed transmembrane pressure to determine the limiting flux for the PPHFMM before and after surface modification. Results showed that the limiting flux appeared to be 103, 159, 117, 133, 136, 121 and 152 L/(m^2· h) for the nascent, PVP-immobilized, air, O2, At, CO2 and H2O plasma treated PPHFMM, respectively. After continuous operation for about 50 h in the SMBR, the antifouling characteristics were improved to some extent. 展开更多
关键词 surface modification polypropylene hollow fiber microporous membrane limiting flux submerged membrane-bioreactor antifouling characteristics
下载PDF
Simultaneous removal of organic substances and nitrogen from municipal wastewater by an intermittently aerated submerged membrane bioreactor
4
作者 Jian YU Guo K. FU +1 位作者 Xiong W. OUYANG Wen J. HOU 《Chinese Journal Of Geochemistry》 EI CAS 2006年第B08期257-257,共1页
关键词 废水 有机物质 生物反应器
下载PDF
Treatment of Chinese traditional medicine wastewater in a submerged membrane bioreactor
5
作者 任南琪 陈兆波 +1 位作者 张颖 呼冬雪 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2007年第1期89-92,共4页
A pilot scale test was conducted in a submerged membrane bioreactor SMBR with capacity of 10.0 m3/d for 120 days to treat high-strength Chinese traditional medicine wastewater. Performance of the SMBR was investigated... A pilot scale test was conducted in a submerged membrane bioreactor SMBR with capacity of 10.0 m3/d for 120 days to treat high-strength Chinese traditional medicine wastewater. Performance of the SMBR was investigated with a sludge retention time (TSR) of 50 days, a hydraulic retention time (THR) of 8.0 h, membrane flux of 8.0 L/(m2·h) and dissolved oxygen (DO) concentration of 2.0-3.0 mg/L, respectively. It was observed that the SMBR had high capacity of COD and suspended solid (SS) removal. The influent COD concentration was fluctuated between 1 000 and 5 000 mg/L, while the averaged effluent COD concentration was only 44.6 mg/L. The influent SS concentration was fluctuated between 1 000 and 1 600 mg/L, while little effluent SS was detected. It was found that the COD remove rate increased with mixed liquor suspended solids (MLSS) and organic loading rate (ROL). In order to obtain good-quality effluent, the operational conditions of the SMBR were suggested as follows: the temperature was controlled above 10 ℃, MLSS about 7000 mg/L, ROL under 24.76 kg/(m3·d), low vacuum value and constant water flux. 展开更多
关键词 膜生物反应器 淤泥 废水处理 医药行业
下载PDF
Rgwo performances of submerged membrane bioreactor treating brewery wastewater: A laboratory study
6
作者 张立秋 封莉 +2 位作者 吕炳南 顾仁政 江进 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2005年第4期460-466,共7页
Performances of submerged membrane bioreactor (SMBR) treating brewery wastewater were investigated in this study. With little variation of COD:TN:TP ratio (100:5:1) in influent, SMBR showed high removal efficiency (&g... Performances of submerged membrane bioreactor (SMBR) treating brewery wastewater were investigated in this study. With little variation of COD:TN:TP ratio (100:5:1) in influent, SMBR showed high removal efficiency (>90%) for both COD and NH4^+-N, and it also showed a strong resistive ability for shock organics loading rate, evidenced by no obvious fluctuation for COD in the effluent when the organics loading rate suddenly increased from 0.27 g/(gMLSS·d) to 0.54 g/(gMLSS·d). Comparatively different with the COD removal, TN and TP removal showed a strong correlation with the growth stage of the sludge in SMBR. When the sludge was in the multiplication stage, about 45% of TN was removed and an average removal efficiency of 30% for TP was also observed. However, when the activated sludge was in the steady stage, the removal efficiency for TN decreased to about 30%, whereas, the removal efficiency for TP was very low, and sometimes even below zero. The results of GC/MS indicated that the residual organic matters in the effluent were mainly alkyl hydrocarbon with high molecular weight, and coupling with the results of electroscopic scanning, it is speculated that biomass formed at external and internal membrane fibers played an important role for the removal of small organics. 展开更多
关键词 酿酒厂 废水处理 生物反应器 隔膜 电子扫描
下载PDF
Feasibility and simulation model of a pilot scale membrane bioreactor for wastewater treatment and reuse from Chinese traditional medicine 被引量:4
7
作者 REN Nan-qi YAN Xian-feng +3 位作者 CHEN Zhao-bo HU Dong-xue GONG Man-li GUO Wan-qian 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第2期129-134,共6页
The lack and pollution of water resource make wastewater reuse necessary. The pilot scale long-term tests for submerged membrane bioreactor were conducted to treat the effluents of anaerobic or aerobic treatment proce... The lack and pollution of water resource make wastewater reuse necessary. The pilot scale long-term tests for submerged membrane bioreactor were conducted to treat the effluents of anaerobic or aerobic treatment process for the high-strength Chinese traditional medicine wastewater. This article was focused on the feasibility of the wastewater treatment and reuse at shorter hydraulic retention time (HRT) of 5.0, 3.2 and 2.13 h. MLSS growth, membrane flux, vacuum values and chemical cleaning periods were also investigated. The experimental results of treating two-phase anaerobic treatment effluent demonstrated that the CODfilt was less than 100 mg/L when the influent COD was between 500-10000 mg/L at HRT of 5.0 h, which could satisfy the normal discharged standard in China. The experimental results to treat cross flow aerobic reactor effluent demonstrated that the average value of CODfilt was 17.28 mg/L when the average value of influent COD was 192.84 mg/L at HRT of 2.13 h during 106 d, which could completely meet the normal standard for water reuse. The maximum MLSS and MLVSS reached 24000 and 14500 mg/L at HRT of 3.2 h respectively. Membrane flux had maximal resume degrees of 94.7% at vacuum value of 0.02 MPa after cleaning. Chemical cleaning periods of membrane module were 150 d. A simulation model of operational parameters was also established based on the theory of back propagation neural network and linear regression of traditional mathematical model. The simulation model showed that the optimum operational parameters were suggested as follows: HRT was 5.0 h, SRT was 100 d, the range of COD loading rate was between 10.664-20.451 kg/(m3.d), the range of MLSS was between 7543-13694 mg/L. 展开更多
关键词 submerged membrane bioreactor (smbr Chinese traditional medicine wastewater hydraulic retention time (HRT) simulation model pilot scale test
下载PDF
Effect of Intermittent Aeration on the Treatment Performance in a Submerged Membrane Bioreactor 被引量:2
8
作者 CHANG Junjun LIANG Wei +1 位作者 XIAO Enrong WU Zhenbin 《Wuhan University Journal of Natural Sciences》 CAS 2010年第5期455-460,共6页
In order to improve removal for nitrogen in a pilot-scale submerged membrane bioreactor(SMBR),intermittent aeration was conducted,and the effect on the treatment performance under four kinds of operation condition(... In order to improve removal for nitrogen in a pilot-scale submerged membrane bioreactor(SMBR),intermittent aeration was conducted,and the effect on the treatment performance under four kinds of operation condition(run 1,continuous aeration;run 2,60/60 min aeration on/off time;run 3,60/90 min aeration on/off time;run 4,60/75 min aeration on/off time) was evaluated.The results showed that depending on the specific on/off of the aeration time ratio,removal efficiency of nitrogen could be improved significantly,and the removal rates of total nitrogen(TN) under different operation conditions were 28.0%,59.5%,66.8% and 70.7%,respectively.There were no obvious differences for removal rates for CODCr and ammonia among different operation conditions.In general,intermittent aeration could be used as a feasible way to improve treatment performance for nitrogen in the SMBR. 展开更多
关键词 submerged membrane bioreactor(smbr NITROGEN intermittent aeration operation condition treatment performance
原文传递
Performance of bioferric-submerged membrane bioreactor for dyeing wastewater treatment 被引量:5
9
作者 ZOU Haiyan XI Danli 《Frontiers of Environmental Science & Engineering》 SCIE EI CSCD 2007年第3期374-380,共7页
Adding iron salt or iron hydroxide to sludge-mixed liquor in an aeration tank of a conventional activated sludge processes(bioferric process)can simultaneously improve the sludge’s filterability and enhance the syste... Adding iron salt or iron hydroxide to sludge-mixed liquor in an aeration tank of a conventional activated sludge processes(bioferric process)can simultaneously improve the sludge’s filterability and enhance the system’s treatment capacity.In view of this,Fe(OH)3 was added to a submerged membrane bioreactor(SMBR)to enhance the removal efficiency and to mitigate membrane fouling.Bio-ferric process and SMBR were combined to create a novel process called Bioferric-SMBR.A side-by-side comparison study of Bioferric-SMBR and common SMBR dealing with dyeing wastewater was carried out.Bioferric-SMBR showed potential superiority,which could enhance removal efficien-cy,reduce membrane fouling and improve sludge character-istic.When volumetric loading rate was 25% higher than that of common SMBR,the removal efficiencies of Bioferric-SMBR on COD,dye,and NH_(4)^(+)-N were 1.0%,9.5%,and 5.2%higher than that of common SMBR,respectively.The trans-membrane pressure of Bioferric-SMBR was only 36%of that in common SMBR while its membrane flux was 25% higher than that of common SMBR.The stable running period in Bioferric-SMBR was 2.5 times of that in common SMBR when there was no surplus sludge discharged.The mixed liquor suspended solids concentration of Bioferric-SMBR was higher than that of common SMBR with more diversified kinds of microorganisms such as protozoans and metazoans.The mean particle diameter and specific oxygen uptake rate of Bioferric-SMBR were 3.10 and 1.23 times the common SMBR,respectively. 展开更多
关键词 Bioferric-submerged membrane bioreactor(smbr) removal efficiency membrane fouling sludge characteristic dyeing wastewater
原文传递
Investigation on removal pathways of Di 2-ethyl hexyl phthalate from synthetic municipal wastewater using a submerged membrane bioreactor 被引量:2
10
作者 Mehdi Zolfaghari Patrick Drogui +4 位作者 Brahima Seyhi Satinder Kaur Brar Gerardo Buelna Rino Dubé Nouha Klai 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2015年第11期37-50,共14页
Highly hydrophobic Di 2-ethyl hexyl phthalate(DEHP) is one of the most prevalent plasticizers in wastewaters. Since its half-life in biological treatment is around 25 days, it can be used as an efficiency indicator ... Highly hydrophobic Di 2-ethyl hexyl phthalate(DEHP) is one of the most prevalent plasticizers in wastewaters. Since its half-life in biological treatment is around 25 days, it can be used as an efficiency indicator of wastewater treatment plant for the removal of hydrophobic emerging contaminants. In this study, the performance of submerged membrane bioreactor was monitored to understand the effect of DEHP on the growth of aerobic microorganisms. The data showed that the chemical oxygen demand(COD)and ammonia concentration were detected below 10 and 1.0 mg/L, respectively for operating conditions of hydraulic retention time(HRT) = 4 and 6 hr, sludge retention time(SRT) = 140 day and sludge concentration between 11.5 and 15.8 g volatile solid(VS)/L. The removal efficiency of DEHP under these conditions was higher and ranged between 91% and 98%. Results also showed that the removal efficiency of DEHP in biological treatment depended on the concentration of sludge, as adsorption is the main mechanism of its removal. For the submerged membrane bioreactor, the pore size is the pivotal factor for DEHP removal, since it determines the amount of soluble microbial products coming out of the process. Highly assimilated microorganisms increase the biodegradation rate, as 74% of inlet DEHP was biodegraded; however, the concentration of DEHP inside sludge was beyond the discharge limit. Understanding the fate of DEHP in membrane bioreactor,which is one of the most promising and futuristic treatment process could provide replacement for conventional processes to satisfy the future stricter regulations on emerging contaminants. 展开更多
关键词 Di 2-ethyl hexyl phthalate submerged membrane bioreactor Removal efficiency Soluble microbial products Toxicity
原文传递
Performance of Submerged Membrane Bioreactor for Domestic Wastewater Treatment
11
作者 黄霞 桂萍 钱易 《Tsinghua Science and Technology》 EI CAS 2000年第3期237-240,共4页
In the present research, a submerged membrane bioreactor was tested to treat domestic wastewater. Three experimental runs were conducted all with a hydraulic retention time of 5h and sludge retention times (SRTs) of 5... In the present research, a submerged membrane bioreactor was tested to treat domestic wastewater. Three experimental runs were conducted all with a hydraulic retention time of 5h and sludge retention times (SRTs) of 5, 10, and 20 d. The pollutant removal performance of the membrane bioreactor, the membrane effluent quality, and a kinetic model for sludge growth in the bioreactor were investigated. The combined process was capable of removing over 90% of both COD (chemical oxygen demand) and NH 3 N on the average. The total removal for COD was almost independent of SRT, but that for NH 3 N improved with increasing SRT. Membrane effluent quality meets the water quality standard for reuse issued by the Ministry of Construction of China. Increasing SRT causes the concentrations of suspended solids (SS) and volatile suspended solids (VSS) in the bioreactor to increase. However, the ratio of VSS/SS did not change much. Kinetic analysis showed that the sludge yield coefficient (kg VSS·kg COD -1 ) and the endogenous coefficient of microorganisms were 0.25 and 0.04d -1 , which are similar to those of the conventional activated sludge process. 展开更多
关键词 submerged membrane bioreactor domestic wastewater treatment pollutant removal performance effluent quality sludge retention time sludge growing kinetics
原文传递
SMBR工艺处理废水时操作方式的研究 被引量:3
12
作者 王志伟 吴志超 +1 位作者 顾国维 俞国平 《环境工程》 CAS CSCD 北大核心 2005年第4期7-10,共4页
膜生物反应器(MBR)在废水处理中必须能保证长期稳定运行,而操作方式与MBR运行性能密切相关。通过对小试规模的浸没式MBR(SMBR)恒流和恒压两种操作方式的短期以及长期实际运行研究,发现次临界区恒流操作和经济操作压力TMP以下的恒压操作... 膜生物反应器(MBR)在废水处理中必须能保证长期稳定运行,而操作方式与MBR运行性能密切相关。通过对小试规模的浸没式MBR(SMBR)恒流和恒压两种操作方式的短期以及长期实际运行研究,发现次临界区恒流操作和经济操作压力TMP以下的恒压操作有利于MBR的长期稳定运行;并从理论上分析了对应于不同的操作区域的膜污染机理。 展开更多
关键词 浸没式膜生物反应器 恒压 恒流 膜污染 操作方式 smbr 废水处理 工艺处理 膜生物反应器 稳定运行
下载PDF
优化曝气方式对减缓SMBR一体式反应器中膜污染的影响 被引量:3
13
作者 王娜 孙宝盛 +1 位作者 臧倩 张海丰 《水处理技术》 CAS CSCD 北大核心 2007年第12期77-80,共4页
在相同运行条件下,研究了改进型曝气方式(膜出水时气水比为20:1,停止抽吸时气水比为40:1)和传统曝气方式(采用气水比40:1连续曝气)一体式膜生物反应器下SMBR的运行情况。试验结果表明:改进曝气方式的SMBR中胞外聚合物(EPS)和溶解性微生... 在相同运行条件下,研究了改进型曝气方式(膜出水时气水比为20:1,停止抽吸时气水比为40:1)和传统曝气方式(采用气水比40:1连续曝气)一体式膜生物反应器下SMBR的运行情况。试验结果表明:改进曝气方式的SMBR中胞外聚合物(EPS)和溶解性微生物产物(SMP)浓度以及料液粘度都低于传统的SMBR,减轻了膜污染,直观表现为具有较低的跨膜压力(TMP);两种曝气方式的膜阻力均以沉积层阻力为主,改进曝气方式的SMBR沉积层阻力所占比例高于传统的SMBR,后者膜孔吸附及堵塞阻力所占比例远高于前者,因此后者膜清洗费用高;此外改进型曝气方式由于其阶梯式曝气强度降低了能耗。 展开更多
关键词 一体式膜生物反应器 胞外聚合物 溶解性微生物产物 跨膜压力 膜阻力
下载PDF
内电解-SMBR组合工艺处理蒽醌活性染料废水 被引量:3
14
作者 秦磊 王玮 +1 位作者 张国亮 孟琴 《中国环境科学》 EI CAS CSCD 北大核心 2011年第1期25-31,共7页
采用自制的PVDF中空纤维膜组件构建浸入式膜生物反应器,进行了内电解-SMBR组合工艺处理难降解蒽醌染料(活性艳蓝X-BR)废水的试验.试验分为2组,一组为内电解出水直接进入的SMBR-3,另外一组为内电解出水经调节pH值达9~10后进入的SMBR-4.... 采用自制的PVDF中空纤维膜组件构建浸入式膜生物反应器,进行了内电解-SMBR组合工艺处理难降解蒽醌染料(活性艳蓝X-BR)废水的试验.试验分为2组,一组为内电解出水直接进入的SMBR-3,另外一组为内电解出水经调节pH值达9~10后进入的SMBR-4.结果表明,组合工艺中2组SMBR对CODCr、色度和NH4+-N的去除率均很高,且相差不大;但两反应器对TN的去除效果却有明显差异,由于良好生物铁絮体的存在,SMBR-3对TN的去除可高达92.8%,而SMBR-4对TN的去除只有67.5%.与pH值调节后进水相比,内电解直接进水导致活性污泥絮体粒径增大34μm,EPS总量明显增加,且微生物表面结构中有丝状菌出现,菌种也变得相对复杂.对SMBR膜材料进一步检测发现,内电解直接进水所形成的生物铁絮体还可有效减轻膜污染,使膜通量衰减变慢. 展开更多
关键词 内电解 smbr 活性艳蓝X-BR 活性污泥 膜污染
下载PDF
曝气强度对SMBR膜污染的影响 被引量:4
15
作者 秦哲 徐高田 +3 位作者 徐静 赵军 赵朋卫 李庆 《中北大学学报(自然科学版)》 CAS 北大核心 2009年第4期370-375,共6页
改变曝气强度是控制SMBR(Submerged Membrane Bioreactor)膜污染的重要手段之一.在不同的曝气强度下考察了膜过滤压差随时间的变化情况,膜阻力构成情况和污泥指数SVI(Sludge Volume Index)的变化对膜污染的影响.结果表明:曝气强度过大... 改变曝气强度是控制SMBR(Submerged Membrane Bioreactor)膜污染的重要手段之一.在不同的曝气强度下考察了膜过滤压差随时间的变化情况,膜阻力构成情况和污泥指数SVI(Sludge Volume Index)的变化对膜污染的影响.结果表明:曝气强度过大或过小,压差上升速率都会增大;随着曝气强度的增大,Rp,Ref,Rc在过滤总阻力中所占的比例都会逐渐减小,Rif在过滤总阻力中所占的比例逐渐增大;当曝气强度低于0.88 m3.m-2.h-1时,水力剪切力主要作用于膜污染的消除,而对活性污泥的性质没有多大影响,SVI变化不大,因此压差上升速率随曝气强度的增加而降低;而当曝气强度高于0.88 m3.m-2.h-1时,水力剪切力过大,导致污泥絮体结构被破坏,SVI明显增大,从而加速了膜的污染,使压差上升速率随曝气强度的增加而增加. 展开更多
关键词 曝气强度 膜生物反应器 膜污染 SVI
下载PDF
A fouling suppression system in submerged membrane bioreactors using dielectrophoretic forces
16
作者 Alaa H.Hawari Fei Du +1 位作者 Michael Baune Jorg Thming 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2015年第3期139-145,共7页
A novel method was developed to suppress membrane fouling in submerged membrane bioreactors. The method is based on the dielectrophoretic (DEP) motion of particles in an inhomogeneous electrical field. Using a real ... A novel method was developed to suppress membrane fouling in submerged membrane bioreactors. The method is based on the dielectrophoretic (DEP) motion of particles in an inhomogeneous electrical field. Using a real sample ofbiomass as feed, the fouling-suppression performance using DEP with different electrical field intensities (60-160 V) and different frequencies (50-1000 Hz) was investigated. The fouling-suppression performance was found to relate closely with the intensity and frequency of the electrical field. A stronger electrical field was found to better recover the filtrate flux. This is because of a stronger DEP force acting on the biomass par[ides close to the membrane's surface. Above an intensity and frequency value of 130 V and 1 kHz, respectively the permeate flux was reduced due to an electrothermal effect. 展开更多
关键词 submerged membrane bioreactor Dielectrophoresis Inhomogeneous electric field Fouling
原文传递
低温下SRT对SMBR脱氮效果的影响研究 被引量:3
17
作者 秦晓荃 胡湾 +1 位作者 杨明 王秀蘅 《哈尔滨商业大学学报(自然科学版)》 CAS 2013年第1期32-35,共4页
利用一体式膜生物反应器(SMBR),考察低温下SRT对SMBR系统脱氮效果的影响.控制DO为0.5 mg/L,pH值为6.5~7.5,HRT为2 h,MLSS为7 000~8 000 mg/L的条件下,取温度为16℃和12℃作对比.结果表明,SRT为30 d时,SMBR内取得了理想的SND效果,温度... 利用一体式膜生物反应器(SMBR),考察低温下SRT对SMBR系统脱氮效果的影响.控制DO为0.5 mg/L,pH值为6.5~7.5,HRT为2 h,MLSS为7 000~8 000 mg/L的条件下,取温度为16℃和12℃作对比.结果表明,SRT为30 d时,SMBR内取得了理想的SND效果,温度为16℃时,TN和NH3—N的平均去除率分别为93.63%和95.66%.温度为12℃时,TN和NH3—N的平均去除率分别为92.5%和94.3%.控制较好的运行条件,低温条件下系统的脱氮效果与中温时相差不大,均保持在90%以上,出水质量浓度较低.在两种温度条件下,随着SRT的延长,系统的脱氮效果均变差,去除率下降,表明实际工程中,SRT并不是越长越好. 展开更多
关键词 低温 脱氮 一体化膜生物反应器(smbr) 污泥龄(SRT) 同步硝化反硝化(SND)
下载PDF
投加氢氧化铁对SMBR中活性污泥性能的影响 被引量:3
18
作者 刘旭东 秦许河 +1 位作者 李慧 李佳 《环境科学与技术》 CAS CSCD 北大核心 2011年第S1期79-81,88,共4页
试验研究了在SMBR中投加不同量氢氧化铁对出水水质以及膜污染的影响。结果表明,生物铁-SMBR中随氢氧化铁投加量的增加,COD出水及去除率略有提高;氢氧化铁投加量为5%时,对活性污泥的活性促进作用最强;活性污泥SVI的降低主要是氢氧化铁絮... 试验研究了在SMBR中投加不同量氢氧化铁对出水水质以及膜污染的影响。结果表明,生物铁-SMBR中随氢氧化铁投加量的增加,COD出水及去除率略有提高;氢氧化铁投加量为5%时,对活性污泥的活性促进作用最强;活性污泥SVI的降低主要是氢氧化铁絮体本身的化学絮凝作用所致;试验条件下氢氧化铁最佳投加量为混合液污泥浓度的5%时,半透膜压增长最慢,膜污染程度最轻。 展开更多
关键词 一体式膜生物反应器 氢氧化铁 脱氢酶活性 SVI
下载PDF
污泥膨胀对SMBR系统脱氮性能影响的试验研究 被引量:4
19
作者 张颖 吴忆宁 任南琪 《中国给水排水》 CAS CSCD 北大核心 2007年第5期65-68,共4页
以一体式膜生物反应器(SMBR)处理模拟污水,考察了污泥膨胀对SMBR脱氮性能的影响。结果表明,在SMBR运行中,污泥膨胀期对TN和NH3-N的去除效果明显优于对照试验期,丝状菌对氮的竞争能力较强,对污水中营养物质的利用速率较高,污泥膨胀期SMB... 以一体式膜生物反应器(SMBR)处理模拟污水,考察了污泥膨胀对SMBR脱氮性能的影响。结果表明,在SMBR运行中,污泥膨胀期对TN和NH3-N的去除效果明显优于对照试验期,丝状菌对氮的竞争能力较强,对污水中营养物质的利用速率较高,污泥膨胀期SMBR的出水水质较好;在污泥膨胀期,随着运行时间的延长,由于丝状菌的反硝化能力较差,导致出水中出现NO2--N的少量积累;丝状菌带来的负面影响即膜污染问题较为严重,在实际的工程中应采取有效措施控制污泥膨胀。 展开更多
关键词 一体式膜生物反应器 污泥膨胀 脱氮性能
下载PDF
SMBR不同特性膜处理城市内河道水对比试验研究 被引量:3
20
作者 王雪梅 刘燕 华志浩 《环境化学》 CAS CSCD 北大核心 2006年第1期60-64,共5页
用一体浸没式膜生物反应器(SMBR)不同特性膜处理上海市城市内河道水,结果表明,SMBR对氨氮含量较高的富营养化河水,氨氮的去除率在90%以上,但对COD的平均去除率仅为50%.比较两种膜的运行性能,亲水性膜在运行通量和通量恢复能力上,均比疏... 用一体浸没式膜生物反应器(SMBR)不同特性膜处理上海市城市内河道水,结果表明,SMBR对氨氮含量较高的富营养化河水,氨氮的去除率在90%以上,但对COD的平均去除率仅为50%.比较两种膜的运行性能,亲水性膜在运行通量和通量恢复能力上,均比疏水性膜优越.两种膜的出水水质几乎没有差异. 展开更多
关键词 浸没式膜生物反应器 城市内河道水 亲水性膜 疏水性膜
下载PDF
上一页 1 2 7 下一页 到第
使用帮助 返回顶部