Embedded Ethernet technology has been utilized increasingly widely as the communication mode in the substation automation system(SAS).This paper introduces the current applying situation about embedded Ethernet in SAS...Embedded Ethernet technology has been utilized increasingly widely as the communication mode in the substation automation system(SAS).This paper introduces the current applying situation about embedded Ethernet in SAS First.After analyzing the protocol levels used in SAS based on embedded Ethernet and the differences between the TCP and UDP,UDP/IP is selected as the communication protocol between the station-level and bay-level devices for its real-time characteristic.Then a new kind of implementation of the embedded Ethernet is presented based on hardware protocol stack.The designed scheme can be implemented easily,reduce cost significantly and shorten developing cycle.展开更多
Based on a discussion of the feature of a substation, the paper presents the concept that a substation is composed of basic units (BC). The hardware structure of the IED of a BC is described. Next, the paper discusses...Based on a discussion of the feature of a substation, the paper presents the concept that a substation is composed of basic units (BC). The hardware structure of the IED of a BC is described. Next, the paper discusses the communication mode of the current Integrated Substation Automation Systems(ISA) and describes the hardware structre and the functions of the ISA with fieldbus. At last the paper presents trends in the development of ISA.展开更多
Greater complexity and interconnectivity across systems embracing electrical power technologies has meant that cyber-security issues have attracted significant attention. In this paper a simulation environment for int...Greater complexity and interconnectivity across systems embracing electrical power technologies has meant that cyber-security issues have attracted significant attention. In this paper a simulation environment for intrusion detection system in IEC 61850 standard-based substation automation system is provided to test simulated attacks on IEDs (intelligent electronic devices). Intrusion detection is the process of detecting malicious attacker, so it is an effective and mature security mechanism to protect electrical facility. However, it is not harnessed when securing IEC 61850 automated substation. To prove the detection capability of the system testing environment was developed to analyze and test attacks simulated with different test cases. It shows that the simulation environment works accordingly to various network traffic scenarios and eventually proves the functionality of intrusion detection system to be later deployed in the real IEC 61850 based substation automation system site.展开更多
IEC 61850 allows the replacement of conventional wire based systems to communication based system with local area network. Since new engineering processes are introduced in substation, the specifications and tools are...IEC 61850 allows the replacement of conventional wire based systems to communication based system with local area network. Since new engineering processes are introduced in substation, the specifications and tools are required combined with new skills across the substation engineering. In order to construct the IEC 61850 based substation automation system, the IED engineering tools as an engineering means are necessary to cope with the substation automation by full digital devices in the real power systems. Compared the configuration tools provided IEDs vendors which are able to support the operation and communication analysis between IEDs, the XML based IED integration engineering tools as substation engineering tools which are developed can build, edit and save the ICD, SCL and CID files. Particularly, the substation engineering tools are possible to apply the IEC 61850 based IEDs for the engineering process of systems and also provide the reliability and efficiency of system for the utilities and manufacturers. The developed tools are applied to test and create the SCL files for domestic-made IEDs, and then compared with the conventional tools. The reliability including accuracy of results was proved.展开更多
The article discusses the possibility of a potential reduction in the number of operations of microprocessor relay protection of feeders of the contact network of AC railways TsZA-27.5-FKS (FTS) for unknown reasons. R...The article discusses the possibility of a potential reduction in the number of operations of microprocessor relay protection of feeders of the contact network of AC railways TsZA-27.5-FKS (FTS) for unknown reasons. Real statistics on the number of microprocessor relay protection operations at the Buryatskaya traction substation are presented, simulation of the real train situation (in accordance with the regime maps of the throughput capacity of the sections of the Trans-Baikal railway) was carried out in the specialized software complex “KORTES”. Based on the results of the analysis of simulation modeling, the process of forming a unified template of settings using neural network technologies is considered, which characterizes only this specific regular train situation. To protect objects in the event of pre-emergency and emergency modes of operation of the traction power supply system, a variant of changing the standard operation algorithm of the TsZA-27.5-FKS (FTS) terminal by introducing additional blocks for calculating the predictive functions of current and voltage has been proposed.展开更多
The IEC 61850 standard stipulates the Substation Configuration Description Language (SCL) file as a means to define the substation equipment, IED function and also the communication mechanism for the substation area n...The IEC 61850 standard stipulates the Substation Configuration Description Language (SCL) file as a means to define the substation equipment, IED function and also the communication mechanism for the substation area network. The SCL is an eXtensible Markup Language (XML) based file which helps to describe the configuration of the substation Intelligent Electronic Devices (IED) including their associated functions. The SCL file is also configured to contain all IED capabilities including data model which is structured into objects for easy descriptive modeling. The effective functioning of this SCL file relies on appropriate validation techniques which check the data model for errors due to non-conformity to the IEC 61850 standard. In this research, we extend the conventional SCL validation algorithm to develop a more advanced validator which can validate the standard data model using the Unified Modeling Language (UML). By using the Rule-based SCL validation tool, we implement validation test cases for a more comprehensive understanding of the various validation functionalities. It can be observed from the algorithm and the various implemented test cases that the proposed validation tool can improve SCL information validation and also help automation engineers to comprehend the IEC 61850 substation system architecture.展开更多
The problem of logical node(LN)importance quantification in an IEC 61850 based substation automation system(SAS)is investigated in this paper.First,a weighted and directed static complex network model is established b...The problem of logical node(LN)importance quantification in an IEC 61850 based substation automation system(SAS)is investigated in this paper.First,a weighted and directed static complex network model is established by analyzing the characteristics of SAS,according to IEC 61850.Then,we propose a method,which combines topology value and information adjunction value by introducing a first-order linear feedback controller to quantify the value of LNs.On this basis,some definitions for equivalent network conversion are proposed to greatly reduce the complexity of the original network topology.Also,the absolute value and relative value are introduced to quantify LN importance from the perspective of the node’s necessity and influence,respectively.Finally,simulation results of the case study demonstrate that the proposed method is effective and provides a broader and clearer perspective for viewing the logical node importance for IEC61850 based SAS.展开更多
文摘Embedded Ethernet technology has been utilized increasingly widely as the communication mode in the substation automation system(SAS).This paper introduces the current applying situation about embedded Ethernet in SAS First.After analyzing the protocol levels used in SAS based on embedded Ethernet and the differences between the TCP and UDP,UDP/IP is selected as the communication protocol between the station-level and bay-level devices for its real-time characteristic.Then a new kind of implementation of the embedded Ethernet is presented based on hardware protocol stack.The designed scheme can be implemented easily,reduce cost significantly and shorten developing cycle.
文摘Based on a discussion of the feature of a substation, the paper presents the concept that a substation is composed of basic units (BC). The hardware structure of the IED of a BC is described. Next, the paper discusses the communication mode of the current Integrated Substation Automation Systems(ISA) and describes the hardware structre and the functions of the ISA with fieldbus. At last the paper presents trends in the development of ISA.
文摘Greater complexity and interconnectivity across systems embracing electrical power technologies has meant that cyber-security issues have attracted significant attention. In this paper a simulation environment for intrusion detection system in IEC 61850 standard-based substation automation system is provided to test simulated attacks on IEDs (intelligent electronic devices). Intrusion detection is the process of detecting malicious attacker, so it is an effective and mature security mechanism to protect electrical facility. However, it is not harnessed when securing IEC 61850 automated substation. To prove the detection capability of the system testing environment was developed to analyze and test attacks simulated with different test cases. It shows that the simulation environment works accordingly to various network traffic scenarios and eventually proves the functionality of intrusion detection system to be later deployed in the real IEC 61850 based substation automation system site.
文摘IEC 61850 allows the replacement of conventional wire based systems to communication based system with local area network. Since new engineering processes are introduced in substation, the specifications and tools are required combined with new skills across the substation engineering. In order to construct the IEC 61850 based substation automation system, the IED engineering tools as an engineering means are necessary to cope with the substation automation by full digital devices in the real power systems. Compared the configuration tools provided IEDs vendors which are able to support the operation and communication analysis between IEDs, the XML based IED integration engineering tools as substation engineering tools which are developed can build, edit and save the ICD, SCL and CID files. Particularly, the substation engineering tools are possible to apply the IEC 61850 based IEDs for the engineering process of systems and also provide the reliability and efficiency of system for the utilities and manufacturers. The developed tools are applied to test and create the SCL files for domestic-made IEDs, and then compared with the conventional tools. The reliability including accuracy of results was proved.
文摘The article discusses the possibility of a potential reduction in the number of operations of microprocessor relay protection of feeders of the contact network of AC railways TsZA-27.5-FKS (FTS) for unknown reasons. Real statistics on the number of microprocessor relay protection operations at the Buryatskaya traction substation are presented, simulation of the real train situation (in accordance with the regime maps of the throughput capacity of the sections of the Trans-Baikal railway) was carried out in the specialized software complex “KORTES”. Based on the results of the analysis of simulation modeling, the process of forming a unified template of settings using neural network technologies is considered, which characterizes only this specific regular train situation. To protect objects in the event of pre-emergency and emergency modes of operation of the traction power supply system, a variant of changing the standard operation algorithm of the TsZA-27.5-FKS (FTS) terminal by introducing additional blocks for calculating the predictive functions of current and voltage has been proposed.
文摘The IEC 61850 standard stipulates the Substation Configuration Description Language (SCL) file as a means to define the substation equipment, IED function and also the communication mechanism for the substation area network. The SCL is an eXtensible Markup Language (XML) based file which helps to describe the configuration of the substation Intelligent Electronic Devices (IED) including their associated functions. The SCL file is also configured to contain all IED capabilities including data model which is structured into objects for easy descriptive modeling. The effective functioning of this SCL file relies on appropriate validation techniques which check the data model for errors due to non-conformity to the IEC 61850 standard. In this research, we extend the conventional SCL validation algorithm to develop a more advanced validator which can validate the standard data model using the Unified Modeling Language (UML). By using the Rule-based SCL validation tool, we implement validation test cases for a more comprehensive understanding of the various validation functionalities. It can be observed from the algorithm and the various implemented test cases that the proposed validation tool can improve SCL information validation and also help automation engineers to comprehend the IEC 61850 substation system architecture.
基金This work was supported in part by the National Natural Science Foundation of China(U1866209)。
文摘The problem of logical node(LN)importance quantification in an IEC 61850 based substation automation system(SAS)is investigated in this paper.First,a weighted and directed static complex network model is established by analyzing the characteristics of SAS,according to IEC 61850.Then,we propose a method,which combines topology value and information adjunction value by introducing a first-order linear feedback controller to quantify the value of LNs.On this basis,some definitions for equivalent network conversion are proposed to greatly reduce the complexity of the original network topology.Also,the absolute value and relative value are introduced to quantify LN importance from the perspective of the node’s necessity and influence,respectively.Finally,simulation results of the case study demonstrate that the proposed method is effective and provides a broader and clearer perspective for viewing the logical node importance for IEC61850 based SAS.