On March 31, in accordance with the typical design requirements of the State Grid, the f irst large electric vehicle (EV) charging station, built by the North China Grid,
Parametric design of typical parts holds a very important position during process of product designs. In order to develop a parametric design system of typical parts compatible with heterogeneous CAD systems, this pap...Parametric design of typical parts holds a very important position during process of product designs. In order to develop a parametric design system of typical parts compatible with heterogeneous CAD systems, this paper presents a framework of a network-oriented design system of typical parts, enabled by eXtensible Markup Language (XML), capable of providing parametric design. Firstly, an overview of the framework is presented. In order to map the part feature hierarchy tree of 3D model into an XML tree, an XML-based part template is introduced. The methods of XML-based parametric design and parametric design navigation are described. Finally, an application example of prototype system under the Pro/Engineer platform is given. The application indicates that the proposed framework is valid for parametric design of typical parts/components in heterogeneous CAD systems.展开更多
This paper describes economical strategies to design blast resistant electrical substations and control buildings that are commonly used at industrial plants.Limited literature addressed design aspects for this class ...This paper describes economical strategies to design blast resistant electrical substations and control buildings that are commonly used at industrial plants.Limited literature addressed design aspects for this class of buildings.Furthermore,little guidelines are available in practice to regulate this type of steel construction.The first part of the paper overviews the architectural and structural layouts of electrical buildings.Blast resistance requirements for occupied control buildings are also discussed.Simplified multiple degrees of freedom(MDOF)dynamic model is also illustrated that can be utilized for analysis of the blast resistant buildings.The economical aspects and cost savings resulting in using mobile blast resistant buildings are discussed.The article also highlights the engineering challenges that are encountered in design of mobile electrical facilities.The transportation procedure and design requirements are briefly described.Guidelines are proposed to calculate the center of mass of the building combined with interior equipment.The proposed design concept for electrical and control buildings is cost effective and can be implemented in industry to reduce projects cost.展开更多
The traditional power design, construction, has been able to meet the requirements, but it has not been established engineering data database support and the correlation between the data is poor, due to inadequate coo...The traditional power design, construction, has been able to meet the requirements, but it has not been established engineering data database support and the correlation between the data is poor, due to inadequate coordination among design professionals, design easily lead to mistakes, field problems, and design results failed in all aspects of the project to be fully utilized. With the technology of three-dimensional integrated design system penetrates in all walks of life, the introduction of three-dimensional integrated design system substation design solutions and the application of common devices of State Grid Corporation in recent years, which provide technical conditions for the application of virtual reality technology in substation design. According to its own characteristics of substation project, we now propose prospect on virtual reality technology in substation design application.展开更多
Some brief informations about AC 500 kV substations inChina, historical data of their design and essential design principles arepresented in thes paper. Some technical and engineering problems ofAC 500 kV substation d...Some brief informations about AC 500 kV substations inChina, historical data of their design and essential design principles arepresented in thes paper. Some technical and engineering problems ofAC 500 kV substation design and construction are discussed. It isemphasized to introduce the 500 kV substation scales, main electricalconnections, selection of equipment and apparatus, insulationcoordination, distribution sWitchyard, control and protection etc.. Herewe also discuss the policy of project cost control at present time and aprospective view of China AC substahons in future.展开更多
文摘On March 31, in accordance with the typical design requirements of the State Grid, the f irst large electric vehicle (EV) charging station, built by the North China Grid,
基金Project supported by the National Key Lab . of Flexible Manufacturing System Technology ( Grant No.51458060104J W0316) the National High-Tech. R & D Programfor CI MS , China (Grant No.2003AA414033) .
文摘Parametric design of typical parts holds a very important position during process of product designs. In order to develop a parametric design system of typical parts compatible with heterogeneous CAD systems, this paper presents a framework of a network-oriented design system of typical parts, enabled by eXtensible Markup Language (XML), capable of providing parametric design. Firstly, an overview of the framework is presented. In order to map the part feature hierarchy tree of 3D model into an XML tree, an XML-based part template is introduced. The methods of XML-based parametric design and parametric design navigation are described. Finally, an application example of prototype system under the Pro/Engineer platform is given. The application indicates that the proposed framework is valid for parametric design of typical parts/components in heterogeneous CAD systems.
文摘This paper describes economical strategies to design blast resistant electrical substations and control buildings that are commonly used at industrial plants.Limited literature addressed design aspects for this class of buildings.Furthermore,little guidelines are available in practice to regulate this type of steel construction.The first part of the paper overviews the architectural and structural layouts of electrical buildings.Blast resistance requirements for occupied control buildings are also discussed.Simplified multiple degrees of freedom(MDOF)dynamic model is also illustrated that can be utilized for analysis of the blast resistant buildings.The economical aspects and cost savings resulting in using mobile blast resistant buildings are discussed.The article also highlights the engineering challenges that are encountered in design of mobile electrical facilities.The transportation procedure and design requirements are briefly described.Guidelines are proposed to calculate the center of mass of the building combined with interior equipment.The proposed design concept for electrical and control buildings is cost effective and can be implemented in industry to reduce projects cost.
文摘The traditional power design, construction, has been able to meet the requirements, but it has not been established engineering data database support and the correlation between the data is poor, due to inadequate coordination among design professionals, design easily lead to mistakes, field problems, and design results failed in all aspects of the project to be fully utilized. With the technology of three-dimensional integrated design system penetrates in all walks of life, the introduction of three-dimensional integrated design system substation design solutions and the application of common devices of State Grid Corporation in recent years, which provide technical conditions for the application of virtual reality technology in substation design. According to its own characteristics of substation project, we now propose prospect on virtual reality technology in substation design application.
文摘Some brief informations about AC 500 kV substations inChina, historical data of their design and essential design principles arepresented in thes paper. Some technical and engineering problems ofAC 500 kV substation design and construction are discussed. It isemphasized to introduce the 500 kV substation scales, main electricalconnections, selection of equipment and apparatus, insulationcoordination, distribution sWitchyard, control and protection etc.. Herewe also discuss the policy of project cost control at present time and aprospective view of China AC substahons in future.